943 resultados para ION CHEMISTRY
Resumo:
Excitation of tert-butylnitrite into the first and second UV absorption bands leads to efficient dissociation into the fragment radicals NO and tert-butoxy in their electronic ground states (2)Π and (2)E, respectively. Velocity distributions and angular anisotropies for the NO fragment in several hundred rotational and vibrational quantum states were obtained by velocity-map imaging and the recently developed 3D-REMPI method. Excitation into the well resolved vibronic progression bands (k = 0, 1, 2) of the NO stretch mode in the S(1) ← S(0) transition produces NO fragments mostly in the vibrational state with v = k, with smaller fractions in v = k - 1 and v = k - 2. It is concluded that dissociation occurs on the purely repulsive PES of S(1) without barrier. All velocity distributions from photolysis via the S(1)(nπ*) state are monomodal and show high negative anisotropy (β ≈ -1). The rotational distributions peak near j = 30.5 irrespective of the vibronic state S(1)(k) excited and the vibrational state v of the NO fragment. On average 46% of the excess energy is converted to kinetic energy, 23% and 31% remain as internal energy in the NO fragment and the t-BuO radical, respectively. Photolysis via excitation into the S(2) ← S(0) transition at 227 nm yields NO fragments with about equal populations in v = 0 and v = 1. The rotational distributions have a single maximum near j = 59.5. The velocity distributions are monomodal with positive anisotropy β ≈ 0.8. The average fractions of the excess energy distributed into translation, internal energy of NO, and internal energy of t-BuO are 39%, 23%, and 38%, respectively. In all cases ∼8500 cm(-1) of energy remain in the internal degrees of freedom of the t-BuO fragment. This is mostly assigned to rotational energy. An ab initio calculation of the dynamic reaction path shows that not only the NO fragment but also the t-BuO fragment gain large angular momentum during dissociation on the purely repulsive potential energy surface of S(2).
Resumo:
We describe the measurement, at 100 K, of the SIMS relative sensitivity factors (RSFs) of the main physiological cations Na+, K+, Mg2+, and Ca2+ in frozen-hydrated (F-H) ionic solutions. Freezing was performed by either plunge freezing or high-pressure freezing. We also report the measurement of the RSFs in flax fibers, which are a model for ions in the plant cell wall, and in F-H ionic samples, which are a model for ions in the vacuole. RSFs were determined under bombardment with neutral oxygen (FAB) for both the fibers and the F-H samples. We show that referencing to ice-characteristic secondary ions is of little value in determining RSFs and that referencing to K is preferable. The RSFs of Na relative to K and of Ca relative to Mg in F-H samples are similar to their respective values in fiber samples, whereas the RSFs of both Ca and Mg relative to K are lower in fibers than in F-H samples. Our data show that the physical factors important for the determination of the RSFs are not the same in F-H samples and in homogeneous matrixes. Our data show that it is possible to perform a SIMS relative quantification of the cations in frozen-hydrated samples with an accuracy on the order of 15%. Referencing to K permits the quantification of the ionic ratios, even when the absolute concentration of the referencing ion is unknown. This is essential for physiological studies of F-H biological samples.
Resumo:
The mineral in our teeth is composed of a calcium-deficient carbonated hydroxyapatite (Ca10-xNax(PO4)6-y(CO3)z(OH)2-uFu). These substitutions in the mineral crystal lattice, especially carbonate, renders tooth mineral more acid soluble than hydroxyapatite. During erosion by acid and/or chelators, these agents interact with the surface of the mineral crystals, but only after they diffuse through the plaque, the pellicle, and the protein/lipid coating of the individual crystals themselves. The effect of direct attack by the hydrogen ion is to combine with the carbonate and/or phosphate releasing all of the ions from that region of the crystal surface leading to direct surface etching. Acids such as citric acid have a more complex interaction. In water they exist as a mixture of hydrogen ions, acid anions (e.g. citrate) and undissociated acid molecules, with the amounts of each determined by the acid dissociation constant (pKa) and the pH of the solution. Above the effect of the hydrogen ion, the citrate ion can complex with calcium also removing it from the crystal surface and/or from saliva. Values of the strength of acid (pKa) and for the anion-calcium interaction and the mechanisms of interaction with the tooth mineral on the surface and underneath are described in detail.
Resumo:
The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 mu A C- out of gaseous samples with an efficiency of 3-6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3-30 mu g carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of C-14/C-12 could be repeated within statistical errors to better than 1.0% and the C-13/C-12 ratios to better than 0.2%. The blank was < 1 pMC.
Resumo:
Somatostatin-based radioligands have been shown to have sensitive imaging properties for neuroendocrine tumours and their metastases. The potential of [(55)Co(dotatoc)] (dotatoc =4,7,10-tricarboxymethyl-1,4,7,10-tetraazacyclododecane-1-ylacetyl-D-Phe-(Cys-Tyr-D-Trp-Lys-Thr-Cys)-threoninol (disulfide bond)) as a new radiopharmaceutical agent for PET has been evaluated. (57)Co was used as a surrogate of the positron emitter (55)Co and the pharmacokinetics of [(57)Co(dotatoc)] were investigated by using two nude mouse models. The somatostatin receptor subtype (sst1-sst5) affinity profile of [(nat)Co(dotatoc)] on membranes transfected with human somatostatin receptor subtypes was assessed by using autoradiographic methods. These studies revealed that [(57)Co(dotatoc)] is an sst2-specific radiopeptide which presents the highest affinity ever found for the sst2 receptor subtype. The rate of internalisation into the AR4-2J cell line also was the highest found for any somatostatin-based radiopeptide. Biodistribution studies, performed in nude mice bearing an AR4-2J tumour or a transfected HEK-sst2 cell-based tumour, showed high and specific uptake in the tumour and in other sst-receptor-expressing tissues, which reflects the high receptor binding affinity and the high rate of internalisation. The pharmacologic differences between [(57)Co(dotatoc)] and [(67)Ga(dotatoc)] are discussed in terms of the structural parameters found for the chelate models [Co(II)(dota)](2-) and [Ga(III)(dota)](-) whose X-ray structures have been determined. Both chelates show six-fold coordination in pseudo-octahedral arrangements.
Resumo:
Atmospheric aerosol water-soluble organic compounds (WSOC) exist in a complex mixture of thousands of organic compounds which may have a significant influence on the climate-relevant properties of the atmospheric aerosol. To understand the potential influences, the ambient aerosol was collected at a nonurban mountainous site near Steamboat Springs, CO. The WSOC fraction was analyzed using positive and negative electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. Approximately 2400 and 4000 molecular formulas were identified from the detected positive and negative ions, respectively. The formulas contained carbon (C), hydrogen (H), oxygen (O), nitrogen (N), and sulfur (S) atoms over the mass range of 100-800 Da in both ionization modes. The number range of double bond equivalents (DBE), the mean O:C, H:C, and oxidation state of carbon for the positive ions were 0 – 18, 0.25 ± 0.15, 1.39 ± 0.29, and -0.89 ± 0.23, respectively. Comparatively, the negative ion values were 0 – 14, 0.53 ± 0.20, 1.48 ± 0.30, and -0.41 ± 0.45, respectively. Overall, the positive ion molecular formulas were less oxygenated than negative ions as seen with the lower O:C and OSc values. Molecular formulas of the positive ions classified as aliphatic, olefinic, and aromatic compound classes based on the aromaticity index values. Aliphatic compounds were the CHNO and CHO formulas that had mean DBE values of about 5 and 3, respectively. However, a majority of the CHOS, CHNOS, and CHS formulas were defined as olefinic compounds and had mean DBE values of about 12, 13, and 10, respectively. Overall, more than half of the assigned molecular formulas contained sulfur and were olefinic to aromatic compounds with a DBE range of 7-18. Source of the unsaturated sulfur containing compounds is currently unknown. Several nitrogen containing compounds were in common with the field and laboratory studies of the biomass burning aerosol and aged secondary organic aerosol products of the limonene ozonolysis.
Resumo:
In this study, we present the development and the characterization of a generic platform for cell culture able to monitor extracellular ionic activities (K+, NH4+) for real-time monitoring of cell-based responses, such as necrosis, apoptosis, or differentiation. The platform for cell culture is equipped with an array of 16 silicon nitride micropipet-based ion-selective microelectrodes with a diameter of either 2 or 6 microm. This array is located at the bottom of a 200-microm-wide and 350-microm-deep microwell where the cells are cultured. The characterization of the ion-selective microelectrode arrays in different standard and physiological solutions is presented. Near-Nernstian slopes were obtained for potassium- (58.6 +/- 0.8 mV/pK, n = 15) and ammonium-selective microelectrodes (59.4 +/- 3.9 mV/pNH4, n = 13). The calibration curves were highly reproducible and showed an average drift of 4.4 +/- 2.3 mV/h (n = 10). Long-term behavior and response after immersion in physiological solutions are also presented. The lifetime of the sensors was found to be extremely long with a high recovery rate.
Resumo:
For more than 4 years, gaseous samples of 1-50 mu g carbon have been routinely measured with the gas ion source of the small AMS (Accelerator Mass Spectrometer) facility MICADAS (Mini CArbon DAting System) at ETH Zurich. The applied measurement technique offers a simple and fast way of C-14 measurements without the need of sample graphitization. A major drawback of gaseous C-14 measurements, however, is the relatively low negative ion current, which results in longer measurement times and lower precision compared to graphitized samples. In December 2009, a new, improved Cs sputter ion source was installed at MICADAS and we began to optimize conditions for the measurement of gaseous samples. C-12(-) currents from the new ion source were improved from initially 3 to 12-15 mu A for routine measurements and the negative ion yield was increased by a factor of 2, reaching 8 on average during routine operation. Moreover, the new measurement settings enable a doubled CO2 flow, thus substantially reducing measurement times. The achieved performance allows closing the sample size gap between gaseous and solid samples and makes the gas ion source a promising tool for dating with a measurement precision of 5 parts per thousand on samples as small as 50 mu g carbon. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
In 2010 more than 600 radiocarbon samples were measured with the gas ion source at the MIni CArbon DAting System (MICADAS) at ETH Zurich and the number of measurements is rising quickly. While most samples contain less than 50 mu g C at present, the gas ion source is attractive as well for larger samples because the time-consuming graphitization is omitted. Additionally, modern samples are now measured down to 5 per-mill counting statistics in less than 30 min with the recently improved gas ion source. In the versatile gas handling system, a stepping-motor-driven syringe presses a mixture of helium and sample CO2 into the gas ion source, allowing continuous and stable measurements of different kinds of samples. CO2 can be provided in four different ways to the versatile gas interface. As a primary method. CO2 is delivered in glass or quartz ampoules. In this case, the CO2 is released in an automated ampoule cracker with 8 positions for individual samples. Secondly, OX-1 and blank gas in helium can be provided to the syringe by directly connecting gas bottles to the gas interface at the stage of the cracker. Thirdly, solid samples can be combusted in an elemental analyzer or in a thermo-optical OC/EC aerosol analyzer where the produced CO2 is transferred to the syringe via a zeolite trap for gas concentration. As a fourth method, CO2 is released from carbonates with phosphoric acid in septum-sealed vials and loaded onto the same trap used for the elemental analyzer. All four methods allow complete automation of the measurement, even though minor user input is presently still required. Details on the setup, versatility and applications of the gas handling system are given. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Mass spectrometric analysis of elemental and isotopic compositions of several NIST standards is performed by a miniature laser ablation/ionisation reflectron-type time-of-flight mass spectrometer (LMS) using a fs-laser ablation ion source (775 nm, 190 fs, 1 kHz). The results of the mass spectrometric studies indicate that in a defined range of laser irradiance (fluence) and for a certain number of accumulations of single laser shot spectra, the measurements of isotope abundances can be conducted with a measurement accuracy at the per mill level and at the per cent level for isotope concentrations higher and lower than 100 ppm, respectively. Also the elemental analysis can be performed with a good accuracy. The LMS instrument combined with a fs-laser ablation ion source exhibits similar detection efficiency for both metallic and non-metallic elements. Relative sensitivity coefficients were determined and found to be close to one, which is of considerable importance for the development of standard-less instruments. Negligible thermal effects, sample damage and excellent characteristics of the fs-laser beam are thought to be the main reason for substantial improvement of the instrumental performance compared to other laser ablation mass spectrometers.
Resumo:
In this paper a detailed record of major ions from a 20 in deep firn core from Amundsenisen, western Dronning Maud Land, Antarctica, is presented. The core was drilled at 75degreesS, 2degrees E (2900 m.a.s.l.) during austral summer 1991/92. The following ions were measured at 3 cm resolution: Na+, Mg2+, Ca2+, Cl-, NO3-, SO42- and CH3SO3H (MSA). The core was dated back to 1865 using a combination of chemical records and volcanic reference horizons. The volcanic eruptions identified in this core are Mount Ngauruhoe, New Zealand (1974-75), Mount Agung, Indonesia (1963), Azul, Argentina (1932). and a broad peak that corresponds in time to Tarawera, New Zealand (1886), Falcon Island, South Shetlands, Southern Ocean (1885), and Krakatau, Indonesia (1883). There are no trends in any of the ion records, but the annual to decadal changes are large. The mean concentrations of the measured ions are in agreement with those from other high-altitude cores from the Antarctic plateau. At this core site there may be a correspondence between peaks in the MSA record and major El Nino-Southern Oscillation events.
Resumo:
McMurdo Dry Valleys (MDV, Ross Sea region, Antarctica) precipitation exhibits extreme seasonality in ion concentration, 3-5 orders of magnitude between summer and winter precipitation. To identify aerosol sources and investigate causes for the observed amplitude in concentration variability, four snow pits were sampled along a coast-Polar Plateau transect across the MDV. The elevation of the sites ranges from 50 to 2400 m and the distance from the coast from 8 to 93 km. Average chemistry gradients along the transect indicate that most species have either a predominant marine or terrestrial source in the MDV. Empirical orthogonal function analysis on the snow-chemistry time series shows that at least 57% of aerosol deposition occurs concurrently. A conceptual climate model, based on meteorological observations, is used to explain the strong seasonality in the MDV. Our results suggest that radiative forcing of the ice-free valleys creates a surface low-pressure cell during summer which promotes air-mass flow from the Ross Sea. The associated precipitating air mass is relatively warm, humid and contains a high concentration of aerosols. During winter, the MDV are dominated by air masses draining off the East Antarctic ice sheet, that are characterized by cold, dry and low concentrations of aerosols. The strong differences between these two air-mass sources create in the MDV a polar version of the monsoonal flow, with humid, warm summers and dry, cold winters.