964 resultados para INTERVENTIONAL ENDOSCOPY
Resumo:
To evaluate the severity of airway pathologies, quantitative dimensioning of airways is of utmost importance. Endoscopic vision gives a projective image and thus no true scaling information can be directly deduced from it. In this article, an approach based on an interferometric setup, a low-coherence laser source and a standard rigid endoscope is presented, and applied to hollow samples measurements. More generally, the use of the low-coherence interferometric setup detailed here could be extended to any other endoscopy-related field of interest, e.g., gastroscopy, arthroscopy and other medical or industrial applications where tri-dimensional topology is required. The setup design with a multiple fibers illumination system is presented. Demonstration of the method ability to operate on biological samples is assessed through measurements on ex vivo pig bronchi.
Resumo:
BACKGROUND: Laparoscopic techniques have been proposed as an alternative to open surgery for therapy of peptic ulcer perforation. They provide better postoperative comfort and absence of parietal complications, but leakage occurs in 5% of cases. We describe a new method combining laparoscopy and endoluminal endoscopy, designed to ensure complete closure of the perforation. METHODS: Six patients with anterior ulcer perforations (4 duodenal, 2 gastric) underwent a concomitant laparoscopy and endoluminal endoscopy with closure of the orifice by an omental plug attracted into the digestive tract. RESULTS: All perforations were sealed. The mean operating time was 72 minutes. The mean hospital stay was 5.5 days. There was no morbidity and no mortality. At the 30-day evaluation all ulcers but one (due to Helicobacter pylori persistence) were healed. CONCLUSIONS: This method is safe and effective. Its advantages compared with open surgery or laparoscopic patching as well as its cost-effectiveness should be studied in prospective randomized trials.
Resumo:
Objectives: The aim of this study was to assess the concomitant perioperative procedures, the causes of nasolacrimal duct obstruction, the success rate, and the complications associated with endonasal dacryocystorhinostomy (ENDCR).Methods: In this single-center retrospective study, 98 patients underwent 104 ENDCRs between January 1994 and February 2006. There were 78 patients with 84 nasolacrimal duct obstructions who were included in this study.Results: The overall functional success rate with improvement in symptoms was 94.9% for primary surgery (59 of 84 obstructions) and 63.6% for salvage surgery after failure of primary surgery performed in another hospital (25 of 84 obstructions). The mean follow-up time was 36.8 +/- 17.11 months. Primary surgery showed better results, with a complete success rate of 93.2%, than did salvage surgery, with a success rate of only 68%. Persistent symptoms, despite an open rhinostomy, were found in 1.7% of patients with primary surgery and in 12% of those with salvage surgery. Failure of ENDCR was observed in 3.4% of patients after primary surgery and in 20% after salvage surgery. We encountered only minimal perioperative complications, and these were essentially related to lacrimal intubation.Conclusions: Because of the possibility of treating concomitant sinonasal disorders, the cosmetic advantages, and the excellent results, ENDCR represents the procedure of choice for treating nasolacrimal duct obstructions. The main challenge lies in the exact preoperative assessment, as well as postoperative evaluation in case of failure.
Resumo:
PURPOSE: To report the use of argon laser iridoplasty in the management of uveitic acute angle-closure glaucoma. METHODS: Interventional case report. RESULTS: A 46-year-old man developed uveitic acute angle-closure glaucoma with an intraocular pressure (IOP) of 65 mmHg. After unsuccessful attempts with medical treatment and two laser peripheral iridotomies, iridoplasty allowed to break posterior synechiae, open the angle, and reduce the IOP within a few hours. CONCLUSIONS: Argon laser iridoplasty allowed rapid reduction of IOP and prevented the need for emergency surgery. Therefore, the authors stipulate that it is a viable management option in active uveitic acute angle-closure glaucoma.
Resumo:
BACKGROUND: Surgeons' personalities have been described as different from those of the general population, but this was based on small descriptive studies limited by the choice of evaluation instrument. Furthermore, although the importance of the human factor in team performance has been recognized, the effect of personality traits on technical performance is unknown. This study aimed to compare surgical residents' personality traits with those of the general population and to evaluate whether an association exists between their personality traits and technical performance using a virtual reality (VR) laparoscopy simulator. METHODS: In this study, 95 participants (54 residents with basic, 29 with intermediate laparoscopic experience, and 12 students) underwent personality assessment using the NEO-Five Factor Inventory and performed five VR tasks of the Lap Mentor? basic tasks module. The residents' personality traits were compared with those of the general population, and the association between VR performance and personality traits was investigated. RESULTS: Surgical residents showed personality traits different from those of the general population, demonstrating lower neuroticism, higher extraversion and conscientiousness, and male residents showed greater openness. In the multivariable analysis, adjusted for gender and surgical experience, none of the personality traits was found to be an independent predictor of technical performance. CONCLUSIONS: Surgical residents present distinct personality traits that differ from those of the general population. These traits were not found to be associated with technical performance in a virtual environment. The traits may, however, play an important role in team performance, which in turn is highly relevant for optimal surgical performance.
Resumo:
OBJECTIVE: To highlight the clinical presentation, investigation and treatment of haemorrhage into the pancreatic duct. DESIGN: Retrospective study and review of publications. SETTING: University hospital, Switzerland. SUBJECTS: All 4 cases from 1972 to 1993. INTERVENTIONS: 2 Whipple procedures, 1 resection of the pancreatic head, 1 exploratory laparotomy. Radiological embolisation in one case. MAIN OUTCOME MEASURES: Cessation of haemorrhage and survival. RESULTS: The diagnosis was made preoperatively in three cases by gastroduodenoscopy and arteriography. Operation was the primary treatment in all patients and was effective with low morbidity and no mortality in three of them. Embolisation stopped the haemorrhage in the fourth patient, who was alcoholic and died of progressive liver insufficiency and variceal haemorrhage. CONCLUSIONS: There is no specific indication for haemorrhage into the pancreatic duct. The diagnosis is suggested by endoscopy (absence of a more common cause, or blood in the second part of the duodenum). Arteriography is essential to confirm the site of the bleeding and to attempt embolization. Operation is usually the definitive treatment.
Resumo:
The information gathered with intravascular ultrasound (IVUS) are of great value in endovascular techniques. The aim of this study was to evaluate the reliability of IVUS when measuring vessel dimensions by comparison with an established reference method. The left carotid artery was exposed in 4 pigs (45-55 kg) and two piezoelectric crystals were sutured on the adventitia in the same cross-sectional plane. The distance between them was measured either by IVUS and by sonomicrometers. The mean distance between the two crystals calculated by the sonomicrometer was 4.7+/-0.4 mm (mean systolic distance was 4.9+/-0.2 mm, mean diastolic distance was 4.6+/-0.1 mm). The mean distance between the two targets calculated by IVUS was 4. 5+/-0.2 mm (mean systolic distance was 4.6+/-0.2 mm and mean diastolic 4.4+/-0.2 mm). Regression analysis of the two series of data shows a R(2)=0.9984. IVUS measurements are an average 5% smaller than sonomicrometer measurements (3.6% up to 8.3%) and the difference is statistically significant ( p <0.05). The underestimation of IVUS measurements will affect the accuracy, and probably the long-term outcome, of endovascular procedures.
Resumo:
Duchenne muscular dystrophy is is the most common form of the childhood muscular dystrophies. It follows a predictable clinical course marked by progressive skeletal muscle weakness, lost of ambulation before teen-age and death in early adulthood secondary to respiratory or cardiac failure. Becker muscular dystrophy is less common and has a milder clinical course but also results in respiratory and cardiac failure.Altough recent advances in respiratory care and new technologies have improved the outlook many patients already received only a traditional non-interventional approach. The aims of this work are: to analyse the pathophysiology and natural history of respiratory function in these diseases, to descript their clinical manifestations, to present the diagnostics tools and to provide recommendations for an adequated respiratory care in this particular population based on the updated literature referenced.
Resumo:
BACKGROUND: The usual treatment of blunt aortic injury (BAI) is prompt surgery. Frequently severe injuries to the brain or lungs exclude further surgical treatment. The purpose of this study is to assess the feasibility of placing endovascular stent-grafts. METHODS: From 1992 through 1999, in our primary and referral trauma center, 26 acute BAI, 21 males and 5 females, mean age 40.2+/-16.3 yrs were diagnosed. The last 4 patients underwent prospectively endovascular repair with Talent endograft. Endoprosthesis parameters were measured on three-dimensional spiral CT reconstruction. While waiting for devices, blood pressure was aggressively lowered and aortic lesions were monitored by transesophageal echography. RESULTS: Stent-graft deployment was successful in all 4 patients. There were no complications of endoleak, stent migration, paraplegia or death. Angiographic exclusion was complete in all 4 patients. CT scans at a mean follow-up of 11+/-5 months showed complete healing of the aortic wall in all patients. CONCLUSIONS: For stable acute BAI, endovascular stent-graft repair is feasible and safe, and is an effective therapeutic alternative to open surgery. Because of the normal proximal and distal wall in aortic injuries, endoluminal treatment might be the therapy of choice in the near future.
Resumo:
BACKGROUND: Temporal arteritis is a very serious form of vasculitis. Early treatment is essential to avoid blindness. Surgical biopsy of the temporal artery is the gold standard for the diagnosis, but facial nerve injuries may occur. OBJECTIVE: To describe a simple and safe procedure for temporal artery biopsy. METHODS: Case report. RESULTS: A 62-year-old-woman with presumed temporal arteritis was referred. Precise localization of temporal arteries and its branches was obtained with color duplex ultrasonography. Arterial wall thickening (halo sign) was observed in the affected arterial segments. A frontal branch was precisely localized and infiltrated with 1% lidocaine. About 1 cm was removed for histopathologic examination. Thirty minutes was required to perform this outpatient procedure. The diagnosis of temporal arteritis was confirmed, and the patient was rapidly and successfully treated with prednisone. CONCLUSIONS: Color duplex ultrasonography allows precise localization of temporal arteries and its branches. This echocardiography-guided surgical procedure is easy and safe. Most dermatologic surgeons can perform it.
Resumo:
BACKGROUND AND STUDY AIMS: Low dose photodynamic therapy (LDPDT) may modify the mucosal immune response and may thus provide a therapy for Crohn's disease. We evaluated the efficacy and safety of this technique in a murine T cell-mediated colitis model. METHODS: The safety of LDPDT was first tested in BALB/c mice. Naïve T cells were used to induce colitis in mice with severe combined immunodeficiency, which were followed up endoscopically, and a murine endoscopic index of colitis (MEIC) was developed. The efficacy of LDPDT (10 J/cm (2); delta-aminolevulinic acid, 15 mg/kg bodyweight) was then tested on mice with moderate colitis, while a disease control group received no treatment. The MEIC, weight, length, and histology of the colon, cytokine expression indices, number of mucosal CD4 (+) T cells, percentage of apoptotic CD4 (+) T cells, body weight, and systemic side effects were evaluated. RESULTS: LDPDT improved the MEIC ( P = 0.011) and the histological score ( P = 0.025), diminished the expression indices of the proinflammatory cytokines, interleukin-6 ( P = 0.042), interleukin-17 ( P = 0.029), and interferon-gamma ( P = 0.014), decreased the number of mucosal CD4 (+) T cells, and increased the percentage of apoptotic CD4 (+) T cells compared with the disease control group. No local or systemic side effects occurred. CONCLUSION: LDPDT improves murine T cell-mediated colitis, decreases the proinflammatory cytokines interleukin-6, interleukin-17, and interferon-gamma, and decreases the number of CD4 (+) T cells. No adverse events were observed. Therefore, this technique is now being evaluated in patients with inflammatory bowel disease.
Resumo:
BACKGROUND AND STUDY AIMS: The current gold standard in Barrett's esophagus monitoring consists of four-quadrant biopsies every 1-2 cm in accordance with the Seattle protocol. Adding brush cytology processed by digital image cytometry (DICM) may further increase the detection of patients with Barrett's esophagus who are at risk of neoplasia. The aim of the present study was to assess the additional diagnostic value and accuracy of DICM when added to the standard histological analysis in a cross-sectional multicenter study of patients with Barrett's esophagus in Switzerland. METHODS: One hundred sixty-four patients with Barrett's esophagus underwent 239 endoscopies with biopsy and brush cytology. DICM was carried out on 239 cytology specimens. Measures of the test accuracy of DICM (relative risk, sensitivity, specificity, likelihood ratios) were obtained by dichotomizing the histopathology results (high-grade dysplasia or adenocarcinoma vs. all others) and DICM results (aneuploidy/intermediate pattern vs. diploidy). RESULTS: DICM revealed diploidy in 83% of 239 endoscopies, an intermediate pattern in 8.8%, and aneuploidy in 8.4%. An intermediate DICM result carried a relative risk (RR) of 12 and aneuploidy a RR of 27 for high-grade dysplasia/adenocarcinoma. Adding DICM to the standard biopsy protocol, a pathological cytometry result (aneuploid or intermediate) was found in 25 of 239 endoscopies (11%; 18 patients) with low-risk histology (no high-grade dysplasia or adenocarcinoma). During follow-up of 14 of these 18 patients, histological deterioration was seen in 3 (21%). CONCLUSION: DICM from brush cytology may add important information to a standard biopsy protocol by identifying a subgroup of BE-patients with high-risk cellular abnormalities.
Resumo:
Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D X-ray reconstruc-tion angiography (3DRA) and time of °ight magnetic resonance angiography (TOF-MRA) images available in the clinical routine.Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using di®erent imaging equipment. Evaluation included qualitative and quantitative analyses ofthe segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: iso-intensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an inter-modality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE di®ered from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE, respectively) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatabilityof GAR was superior to manual measurements and ISE. The inter-modality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.