661 resultados para IMPAIRS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Epilepsy is a chronic disorder that impairs life quality (LQ) and interferes in emotional, personal, social and family relationship aspects. This study evaluated 165 people with epilepsy diagnosis, ranging from 18 to 75 years old (M=41,28; SD= 13,26), by means of the QQV-65 (Life Quality Questionnaire with 65 questions) and investigated the association between the questionnaire scores and the disease features, comparing patients who showed refrectory seizures with patients with partially controled seizures. There was no difference in relation to the two groups regarding the LQ factor. The QQV-65 emotional factor was the most affected in both groups, since the estimated mean z-escore was 51,0±14,4 for Group I and 49,9±14,7 for Group II. Regarding the type of crisis, the analysis of variance (ANOVA) revealed that Health was the only factor in QQV-65 that showed a statistically significant difference between the z-scores (P = 0.024). However, for the frequency of epileptic seizures, except Health (P = 0.185), other factors QQV-65 proved to be related in a statistically significant way (P> 0.05). The research demonstrated that seizure control perception is quite important in the evaluation of life quality in all its aspects (health, body, society, emotion, locus of control, self-concept and cognition).
Resumo:
Bone defects at interdental osteotomy sites are as a complication of surgi-cally assisted rapid palatal expansion (SARPE). The replacement of osseoustissue by fibrous connective tissue impairs the spontaneous closure of adiastema between central incisors, and orthodontic tooth movementthrough the defect area may lead to root resorption. Treatment of such asituation requires an orthodontic-surgical approach. In this report, wedescribe the lack of bone healing at the midline osteotomy site after SARPE,which was treated by autogenous bone grafting as assessed by cone beamcomputed tomography. In addition, we discuss factors related to the aetiol-ogy and treatment of a bone defect after SARPE.
Resumo:
When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i) abutment substitution to compensate the incorrect angulation of the implant, (ii) clinical crown lengthening, (iii) atraumatic extraction of the left central incisor, and (iv) immediate implant placement. Finally, (v) a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.
Clareamento interno em dentes despolpados como alternativa a procedimentos invasivos: relato de caso
Resumo:
The increasing interest of patients for a better aesthetic appearance of their smile, associated with the development of new materials and techniques, encouraged by media couverage of this concept of beauty, provided an important evolution of cosmetic dentistry. As the darkness of a single anterior tooth or a group of teeth, in most cases, impairs the appearance of the smile and there is growing appreciation of the less invasive procedures, the technique of tooth bleaching is an important option for aesthetic treatment. To have success in the bleaching treatment, it is important to have knowledge of the origin, nature and composition of the stain. Among the causes of color changes acquired post-eruptive, dental trauma, with or without pulp necrosis, is one of the most commonly encountered etiologies, characterized by a reddish-brown color. Current techniques of bleaching for teeth treated endodontically employ oxidative agent hydrogen peroxide. The objective of this paper is to describe the immediate technique of bleaching non-vital tooth by presenting a clinical case.
Resumo:
The human dentition is naturally translucent, opalescent and fluorescent. Differences between the level of fluorescence of tooth structure and restorative materials may result in distinct metameric properties and consequently perceptible disparate esthetic behavior, which impairs the esthetic result of the restorations, frustrating both patients and staff. In this study, we evaluated the level of fluorescence of different composites (Durafill in tones A2 (Du), Charisma in tones A2 (Ch), Venus in tone A2 (Ve), Opallis enamel and dentin in tones A2 (OPD and OPE), Point 4 in tones A2 (P4), Z100 in tones A2 ( Z1), Z250 in tones A2 (Z2), Te-Econom in tones A2 (TE), Tetric Ceram in tones A2 (TC), Tetric Ceram N in tones A1, A2, A4 (TN1, TN2, TN4), Four seasons enamel and dentin in tones A2 (and 4SD 4SE), Empress Direct enamel and dentin in tones A2 (EDE and EDD) and Brilliant in tones A2 (Br)). Cylindrical specimens were prepared, coded and photographed in a standardized manner with a Canon EOS digital camera (400 ISO, 2.8 aperture and 1/ 30 speed), in a dark environment under the action of UV light (25 W). The images were analyzed with the software ScanWhite©-DMC/Darwin systems. The results showed statistical differences between the groups (p < 0.05), and between these same groups and the average fluorescence of the dentition of young (18 to 25 years) and adults (40 to 45 years) taken as control. It can be concluded that: Composites Z100, Z250 (3M ESPE) and Point 4 (Kerr) do not match with the fluorescence of human dentition and the fluorescence of the materials was found to be affected by their own tone.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Diabetes interferes with bone formation and impairs fracture healing, an important complication in humans and animal models. The aim of this study was to examine the impact of diabetes on mesenchymal stem cells (MSCs) during fracture repair.Fracture of the long bones was induced in a streptozotocin-induced type 1 diabetic mouse model with or without insulin or a specific TNF alpha inhibitor, pegsunercept. MSCs were detected with cluster designation-271 (also known as p75 neurotrophin receptor) or stem cell antigen-1 (Sca-1) antibodies in areas of new endochondral bone formation in the calluses. MSC apoptosis was measured by TUNEL assay and proliferation was measured by Ki67 antibody. In vitro apoptosis and proliferation were examined in C3H10T1/2 and human-bone-marrow-derived MSCs following transfection with FOXO1 small interfering (si)RNA.Diabetes significantly increased TNF alpha levels and reduced MSC numbers in new bone area. MSC numbers were restored to normal levels with insulin or pegsunercept treatment. Inhibition of TNF alpha significantly reduced MSC loss by increasing MSC proliferation and decreasing MSC apoptosis in diabetic animals, but had no effect on MSCs in normoglycaemic animals. In vitro experiments established that TNF alpha alone was sufficient to induce apoptosis and inhibit proliferation of MSCs. Furthermore, silencing forkhead box protein O1 (FOXO1) prevented TNF alpha-induced MSC apoptosis and reduced proliferation by regulating apoptotic and cell cycle genes.Diabetes-enhanced TNF alpha significantly reduced MSC numbers in new bone areas during fracture healing. Mechanistically, diabetes-enhanced TNF alpha reduced MSC proliferation and increased MSC apoptosis. Reducing the activity of TNF alpha in vivo may help to preserve endogenous MSCs and maximise regenerative potential in diabetic patients.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Obesity is a risk factor in the development of several respiratory diseases. Lung volumes tend to be decreased, especially expiratory reserve volume, increasing expiratory flow limitation during tidal breathing. Barometric whole-body plethysmography is a non-invasive pulmonary function test that allows a dynamic study of breathing patterns. The objective of this study was to compare pulmonary function variables between obese and non-obese cats through the use of barometric whole-body plethysmography. Nine normal-weight and six obese cats were placed in the plethysmograph chamber, and different respiratory variables were measured. There was a significant decrease in tidal volume per kilogram (P=0.003), minute volume per kilogram (P=0.001) and peak inspiratory and expiratory flows per kilogram (P=0.001) in obese cats compared with non-obese cats. Obesity failed to demonstrate a significant increase in bronchoconstriction index variable enhanced pause (Penh), as previously reported in humans and dogs. The results show that feline obesity impairs pulmonary function in cats, although a significant increase in bronchoconstriction indexes was not observed. Non-invasive barometric whole-body plethysmography can help characterise mechanical dysfunction of the airways in obese cats.