897 resultados para Home monitoring system


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A wide range of non-destructive testing (NDT) methods for the monitoring the health of concrete structure has been studied for several years. The recent rapid evolution of wireless sensor network (WSN) technologies has resulted in the development of sensing elements that can be embedded in concrete, to monitor the health of infrastructure, collect and report valuable related data. The monitoring system can potentially decrease the high installation time and reduce maintenance cost associated with wired monitoring systems. The monitoring sensors need to operate for a long period of time, but sensors batteries have a finite life span. Hence, novel wireless powering methods must be devised. The optimization of wireless power transfer via Strongly Coupled Magnetic Resonance (SCMR) to sensors embedded in concrete is studied here. First, we analytically derive the optimal geometric parameters for transmission of power in the air. This specifically leads to the identification of the local and global optimization parameters and conditions, it was validated through electromagnetic simulations. Second, the optimum conditions were employed in the model for propagation of energy through plain and reinforced concrete at different humidity conditions, and frequencies with extended Debye's model. This analysis leads to the conclusion that SCMR can be used to efficiently power sensors in plain and reinforced concrete at different humidity levels and depth, also validated through electromagnetic simulations. The optimization of wireless power transmission via SMCR to Wearable and Implantable Medical Device (WIMD) are also explored. The optimum conditions from the analytics were used in the model for propagation of energy through different human tissues. This analysis shows that SCMR can be used to efficiently transfer power to sensors in human tissue without overheating through electromagnetic simulations, as excessive power might result in overheating of the tissue. Standard SCMR is sensitive to misalignment; both 2-loops and 3-loops SCMR with misalignment-insensitive performances are presented. The power transfer efficiencies above 50% was achieved over the complete misalignment range of 0°-90° and dramatically better than typical SCMR with efficiencies less than 10% in extreme misalignment topologies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nearly a third of UK gas and electricity is used in homes, of which 80% is for space heating and hot water provision. Rising consumer bills, concerns about climate change and the surge in personal digital technology use has provoked the development of intelligent domestic heating controls. Whilst the need for having suitable control of the home heating system is essential for reducing domestic energy use, these heating controls rely on appropriate user interaction to achieve a saving and it is unclear whether these ‘smart’ heating controls enhance the use of domestic heating or reduce energy demand. This paper describes qualitative research undertaken with a small sample of UK householders to understand how people use new heating controls installed in their homes and what the requirements are for improved smart heating control design. The paper identifies, against Nielsen’s usability heuristics, the divergence between the householder’s use, understanding and expectations of the heating system and the actual design of the system. Digital and smart heating control systems should be designed to maximise usability so that they can be effectively used for efficient heating control by all users. The research highlights the need for development of new systems to readdress the needs of users and redefine the system requirements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La course d’endurance active le système de récompense (SR) et est reliée aux comportements de recherche alimentaire. L’influence de la leptine sur l’activité physique (AP) volontaire est bien documentée d’un point de vue physiologique, mais très peu en termes d’impact hédonique. La leptine inhibe l’effet récompensant lié à la consommation de nourriture et joue un rôle semblable pour d’autres types de stimuli. La leptine s’arrime à la forme longue du récepteur à la leptine (Leprb) situé sur les neurones à dopamine (DA) et GABA de l’aire tegmentale ventrale (ATV) dans le mésencéphale. Signal transducer and Activator of Transcription 3 (STAT3) est un facteur de transcription important de la cascade de signalisation de la leptine. La phosphorylation de STAT3 n’est détectée que dans une parcelle des neurones DA positifs pour le Leprb, conférant aux neurones DA STAT3-spécifiques des caractéristiques uniques. Nous avons généré un modèle murin invalidé pour STAT3 sélectivement dans les neurones DA (STAT3DAT-KO). La première expérience consistait à évaluer les paramètres métaboliques de base de notre modèle en utilisant les chambres métaboliques Comprehensive Lab Animal Monitoring System (CLAMS), incluant l’activité ambulatoire, le ratio d’échanges respiratoires (RER) et la production de chaleur. Les STAT3DAT-KO sont hyperactives, démontré par une activité locomotrice augmentée, mais aucune variation entre les deux groupes n’est observée pour le RER et la production de chaleur, en plus d’un gain de poids identique. Une stratégie de récupération ciblant la réinsertion de STAT3 dans les neurones DA du système mésolimbique normalise l’AP anciennement plus élevée des STAT3DAT-KO à celle des contrôles, suivant l’accès libre à une roue d’exercice (RE) pour une durée de 4 semaines, suivant l’accès libre à une roue d’exercice (RE) pour une durée de 4 semaines. L’injection d’un psychostimulant (agoniste du récepteur DA de type 1 (D1R), le Chloro-APB-Hydrobromide (SKF 82958)) reflète une fonction dopaminergique réduite chez les STAT3DAT-KO. Un test de recherche compulsive de nourriture révèle une suppression de la prise alimentaire chez les deux groupes expérimentaux. Nous démontrons pour la première fois que la motivation alliée à la course d’endurance, indépendamment de la régulation de la prise alimentaire par la leptine, est dépendant d’une signalisation leptine-STAT3 amoindrie dans les neurones DA du système mésolimbique, révélant STAT3 comme élément clé dans la régulation du tonus dopaminergique et des propriétés récompensantes de l’AP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

I-SMART is an Internet-based client management system that allows the State of Iowa and its licensed substance abuse treatment providers to administer, manage and provide cost efficient and quality substance abuse assessment and treatment services. Implementation of the I-SMART System is a key product in meeting the federal government requirements for National Outcome Monitoring System (NOMS).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Our aim was to determine the normative reference values of cardiorespiratory fitness (CRF) and to establish the proportion of subjects with low CRF suggestive of future cardio-metabolic risk.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objectives of this study are to investigate the association between cardiorespiratory fitness and cardiovascular risk factors in schoolchildren and to evaluate the degree of association between overall and abdominal adiposity and cardiorespiratory fitness. A total of 1,875 children and adolescents attending public schools in Bogota, Colombia (56.2% girls; age range of 9–17.9 years). A cardiovascular risk score (Z-score) was calculated and participants were divided into tertiles according to low and high levels of overall (sum of the skinfold thicknesses) and abdominal adiposity. Schoolchildren with a high level of overall adiposity demonstrated significant differences in seven of the 10 variables analyzed (i.e. systolic and diastolic blood pressure, triglycerides, triglycerides/HDL-c ratio, total cholesterol, glucose and cardiovascular risk score). Schoolchildren with high levels of both overall and abdominal adiposity and low cardiorespiratory fitness had the least favorable cardiovascular risk factors score. These findings may be relevant to health promotion in Colombian youth.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: El monitoreo hemodinámico es una herramienta para diagnosticar el choque cardiogénico y monitorear la respuesta al tratamiento; puede ser invasivo, mínimamente invasivo o no invasivo. Se realiza rutinariamente con catéter de arteria pulmonar (CAP) o catéter de Swan Ganz; nuevas técnicas de monitoreo hemodinámico mínimamente invasivo tienen menor tasa de complicaciones. Actualmente se desconoce cuál técnica de monitoreo cuenta con mayor seguridad en el paciente con choque cardiogénico. Objetivo: Evaluar la seguridad del monitoreo hemodinámico invasivo comparado con el mínimamente invasivo en pacientes con choque cardiogénico en cuidado intensivo adultos. Diseño: Revisión sistemática de la literatura. Búsqueda en Pubmed, EMBASE, OVID - Cochrane Library, Lilacs, Scielo, registros de ensayos clínicos, actas de conferencias, repositorios, búsqueda de literatura gris en Google Scholar, Teseo y Open Grey hasta agosto de 2016, publicados en inglés y español. Resultados: Se identificó un único estudio con 331 pacientes críticamente enfermos que comparó el monitoreo hemodinámico con CAP versus PiCCO que concluyó que después de la corrección de los factores de confusión, la elección del tipo de monitoreo no influyó en los resultados clínicos más importantes en términos de complicaciones y mortalidad. Dado que se incluyeron otros diagnósticos, no es posible extrapolar los resultados sólo a choque cardiogénico. Conclusión: En la literatura disponible no hay evidencia de que el monitoreo hemodinámico invasivo comparado con el mínimamente invasivo, en pacientes adultos críticamente enfermos con choque cardiogénico, tenga diferencias en cuanto a complicaciones y mortalidad.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: El tiempo promedio del efecto máximo de la insulina regular rápida en la glucemia postprandial ha sido considerado durante años de 120 minutos. En pacientes con Diabetes Mellitus (DM) que usan insulinas análogas este tiempo y los factores asociados no se encuentran reportados para ser aplicados en el automonitoreo. El objetivo de este estudio fue calcular el tiempo y factores relacionados al efecto máximo de la insulina en la glucemia postprandial. Metodología: Se desarrolló un estudio longitudinal retrospectivo a partir de una fuente secundaria donde se realizó un análisis descriptivo y bivariado con las variables demográficas y clínicas presentes en la población. Resultados: El tiempo promedio del pico máximo de insulina en pacientes con DM1 fue de 78.4 (DE± 16.512) y DM2 75.01(DE± 12.02) minutos. El 75% de la población con DM1 y el 54.2% en DM2 era de sexo femenino, la edad promedio en DM1 era 42.38 años y en DM2 68 años, en cuanto a la categorización del IMC el 50% de la población en DM1 y el 37.5% en DM2 estaban dentro del rango de obesidad y se encontró una relación con respecto al tipo de comida “desayuno-cena” vs el tiempo promedio del efecto máximo de la insulina calculado para ambos grupos (p:0.010). Conclusiones: El tiempo promedio del efecto máximo de la insulina calculado fue menor al tiempo reportado en la literatura clínica de 120 minutos. El tipo de comida principal mostró una relación con el tiempo promedio del efecto máximo en ambos grupos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Il diabete mellito (DM) è una delle malattie endocrine più comuni nel cane. Una volta raggiunta la diagnosi di DM, è necessario iniziare un trattamento insulinico nonché una dieta specifica, al fine di controllare i livelli di glucosio nel sangue e di conseguenza i segni clinici. Inoltre, al fine di ottenere un buon controllo glicemico, è essenziale garantire uno stretto monitoraggio terapeutico. Nella presente tesi sono riportati numerosi studi relativi a trattamento, monitoraggio e prognosi dei cani con DM. Il capitolo 2 è una review che illustra i principali aspetti terapeutici e di monitoraggio del DM. Il capitolo 3 riporta uno studio che confronta l'efficacia e la sicurezza dell'insulina Lenta e dell'insulina Neutra Protamine Hagedorn (NPH). I metodi di monitoraggio per cani con DM possono essere classificati in diretti od indiretti. I metodi di monitoraggio diretto includono misurazioni serali della glicemia o monitoraggio continuo del glucosio interstiziale tramite appositi dispositivi (Continuous Glucose Monitoring System, CGMS). Le modalità indirette comprendono la valutazione dell'assunzione di acqua e del peso corporeo, la quantificazione del glucosio/chetoni nelle urine e la misurazione delle concentrazioni di proteine glicate. Il capitolo 4 mostra uno studio volto a valutare l'accuratezza e la precisione di un glucometro e un glucometro/chetometro nel cane. Il Flash Glucose Monitoring system è un CGMS recentemente validato per l'uso nel cane; la sua utilità clinica nel monitoraggio del DM canino è esaminata nel capitolo 5. Il capitolo 6 descrive uno studio in cui si validano 2 metodi analitici per la misurazione delle fruttosamine sieriche e dell'emoglobina glicata nel cane e confronta l’utilità delle due proteine glicate nel definire il controllo glicemico. Infine, il capitolo 7 riporta uno studio finalizzato a determinare il tempo di sopravvivenza e ad identificare il valore prognostico di diverse variabili cliniche e clinico-patologiche nei cani con DM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent years, IoT technology has radically transformed many crucial industrial and service sectors such as healthcare. The multi-facets heterogeneity of the devices and the collected information provides important opportunities to develop innovative systems and services. However, the ubiquitous presence of data silos and the poor semantic interoperability in the IoT landscape constitute a significant obstacle in the pursuit of this goal. Moreover, achieving actionable knowledge from the collected data requires IoT information sources to be analysed using appropriate artificial intelligence techniques such as automated reasoning. In this thesis work, Semantic Web technologies have been investigated as an approach to address both the data integration and reasoning aspect in modern IoT systems. In particular, the contributions presented in this thesis are the following: (1) the IoT Fitness Ontology, an OWL ontology that has been developed in order to overcome the issue of data silos and enable semantic interoperability in the IoT fitness domain; (2) a Linked Open Data web portal for collecting and sharing IoT health datasets with the research community; (3) a novel methodology for embedding knowledge in rule-defined IoT smart home scenarios; and (4) a knowledge-based IoT home automation system that supports a seamless integration of heterogeneous devices and data sources.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The enhanced production of strange hadrons in heavy-ion collisions relative to that in minimum-bias pp collisions is historically considered one of the first signatures of the formation of a deconfined quark-gluon plasma. At the LHC, the ALICE experiment observed that the ratio of strange to non-strange hadron yields increases with the charged-particle multiplicity at midrapidity, starting from pp collisions and evolving smoothly across interaction systems and energies, ultimately reaching Pb-Pb collisions. The understanding of the origin of this effect in small systems remains an open question. This thesis presents a comprehensive study of the production of $K^{0}_{S}$, $\Lambda$ ($\bar{\Lambda}$) and $\Xi^{-}$ ($\bar{\Xi}^{+}$) strange hadrons in pp collisions at $\sqrt{s}$ = 13 TeV collected in LHC Run 2 with ALICE. A novel approach is exploited, introducing, for the first time, the concept of effective energy in the study of strangeness production in hadronic collisions at the LHC. In this work, the ALICE Zero Degree Calorimeters are used to measure the energy carried by forward emitted baryons in pp collisions, which reduces the effective energy available for particle production with respect to the nominal centre-of-mass energy. The results presented in this thesis provide new insights into the interplay, for strangeness production, between the initial stages of the collision and the produced final hadronic state. Finally, the first Run 3 results on the production of $\Omega^{\pm}$ ($\bar{\Omega}^{+}$) multi-strange baryons are presented, measured in pp collisions at $\sqrt{s}$ = 13.6 TeV and 900 GeV, the highest and lowest collision energies reached so far at the LHC. This thesis also presents the development and validation of the ALICE Time-Of-Flight (TOF) data quality monitoring system for LHC Run 3. This work was fundamental to assess the performance of the TOF detector during the commissioning phase, in the Long Shutdown 2, and during the data taking period.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents the case of the San Lorenzo road tunnel, a transportation infrastructure located in the northern part of Italy, involved in the so-called Passo della Morte landslide. This tunnel crosses a large rockslide characterized by slow movements. Damages like water seepage inside the tunnel and concrete lining detachments have surfaced through the years, increasing the risk. This work develops the objective of tracing back the landslide-induced stresses directly responsible for the cracks’ pattern on the most damaged segments of the tunnel. The first section of this work gives information about the global framework: site geography and its strategic relevance, geological setting, hydrological and climate conditions will be provided. The road tunnel infrastructure and its interaction with the landslide phenomena will be discussed together with the active monitoring system, which has been working for more than 20 years. In the second part the several steps and tools used to add more details about the road damages are reported. A visualization of the actual state of the most damaged portions of the road has been reached. Then the attention has been addressed to the stresses acting on the road tunnel’s aforesaid portions, developing a FEM model of a section of the tunnel through a selected software. This latter process can be deemed as a beginning for further developments. Some preliminary results are shown to demonstrate the goodness of the assumptions made. The possible future set by this work aims at constant enlargement of information to be provided to the FEM software, and at the validation of the obtained results through the monitoring data interpretative tools.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Various fall-detection solutions have been previously proposed to create a reliable surveillance system for elderly people with high requirements on accuracy, sensitivity and specificity. In this paper, an enhanced fall detection system is proposed for elderly person monitoring that is based on smart sensors worn on the body and operating through consumer home networks. With treble thresholds, accidental falls can be detected in the home healthcare environment. By utilizing information gathered from an accelerometer, cardiotachometer and smart sensors, the impacts of falls can be logged and distinguished from normal daily activities. The proposed system has been deployed in a prototype system as detailed in this paper. From a test group of 30 healthy participants, it was found that the proposed fall detection system can achieve a high detection accuracy of 97.5%, while the sensitivity and specificity are 96.8% and 98.1% respectively. Therefore, this system can reliably be developed and deployed into a consumer product for use as an elderly person monitoring device with high accuracy and a low false positive rate.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Although we have many electric devices at home, there are just few systems to evaluate, monitor and control them. Sometimes users go out and leave their electric devices turned on what can cause energy wasting and dangerous situations. Therefore most of the users may want to know the using states of their electrical appliances through their mobile devices in a pervasive way. In this paper, we propose an Intelligent Supervisory Control System to evaluate, monitor and control the use of electric devices in home, from outside. Because of the transferring data to evaluate, monitor and control user's location and state of home (ex. nobody at home) may be opened to attacks leading to dangerous situations. In our model we include a location privacy module and encryption module to provide security to user location and data. Intelligent Supervising Control System gives to the user the ability to manage electricity loads by means of a multi-agent system involving evaluation, monitoring, control and energy resource agents.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this paper we present ezGo, an electric powered wheelchair with a speech based interface and biosignal monitoring instrumentation. The user can use the voice, a natural communication method, for controlling the chair movement and obtain information about his health. Additionally a set of semi-autonomous modes with macro recording enable the execution of navigation tasks with little effort and improved precision. The main purpose of the system is to provide severely disabled persons with an assistive device that can improve their confidence and daily independence. The obtained results on usability tests showed that users consider ezGo a valuable help on their daily tasks and a very desirable addition to standard wheelchairs.