858 resultados para Hip hop
Resumo:
The goal of this prospective study was to characterize the morphology and physeal changes of the femoral head during maturation using MRI in a population-based group of asymptomatic volunteers.
Resumo:
Scarring or detachment of the hip abductors, particularly of the gluteus medius, from their insertion may lead to severe abductor weakness, recurrent dislocations, pain, and diminished quality of life. We performed a retrospective study to evaluate whether vastus lateralis shift is associated with satisfactory results and low rate of complications. Eleven adults underwent vastus lateralis shift to bridge a well-documented abductor muscles' insertion defect. Preoperative and postoperative hip functions were assessed applying the Merle d'Aubigne score, British Medical Council scale, and Visual Analog Scale. Significant postoperative improvement was noted in mean Merle d'Aubigne score, gluteus medius muscle force, and quality of life. Vastus lateralis shift represents a viable treatment option for hip abductor deficiency, significantly improving abductor strength and overall quality of life.
Resumo:
A 39-year-old female with elevated serum cobalt levels from her bilateral hip prostheses presented with a 3-week history of blurred vision in her left eye. Optical coherence tomography revealed patchy degeneration of the photoreceptor-retinal pigment epithelium (RPE) complex. The lesions were hypofluorescent on indocyanine green angiography. We postulate that this is a case of implant-related chorio-retinal cobalt toxicity.
Resumo:
Deformity and malposition of the acetabulum can occur during the development of the hip. Developmental hip dysplasia and acetabular retroversion are possible causes of osteoarthritis in the young adult. Surgical management with reorientation of the acetabulum allows causal therapy of the deformity and preservation of the native hip joint. Established techniques are the Bernese periacetabular osteotomy (PAO) and the Tönnis and Kalchschmidt triple osteotomy of the pelvis. Both techniques permit three-dimensional correction of the position of the acetabulum. Advantages and disadvantages of each technique must be considered and are summarized in the present paper. If performed early (osteoarthritis grade Tönnis 0 and 1) with correct indication and proper technique, good results can be expected.
Resumo:
Joint-preserving hip surgery, either arthroscopic or open, increasingly is used for the treatment of symptomatic femoroacetabular impingement (FAI). As a consequence of surgery, thickening of the joint capsule and intraarticular adhesions between the labrum and joint capsule and between the femoral neck and the joint capsule have been observed. These alterations are believed to cause persistent pain and reduced range of motion. Because the diagnosis is made with MR arthrography, knowledge of the normal capsular anatomy and thickness on MRI in patients is important. To date there is no such information available.
Resumo:
Osteoarthritis is a chronic joint disease that involves degeneration of articular cartilage. Pre-clinical data suggest that doxycycline might act as a disease-modifying agent for the treatment of osteoarthritis, with the potential to slow cartilage degeneration. This is an update of a Cochrane review first published in 2009.
Resumo:
The aims of the study were (1) to determine the cumulative two to twenty-year survivorship of the hip after open reduction and internal fixation of displaced acetabular fractures, (2) to identify factors predicting conversion to total hip arthroplasty or hip arthrodesis, and (3) to create a predictive model that calculates an individual's probability of early need for total hip arthroplasty or hip arthrodesis.
Resumo:
Osteotomies of the proximal femur and stable fixation of displaced femoral neck fractures are demanding operations. An LCP Paediatric Hip Plate was developed to make these operations safer and less demanding. The article focuses on the surgical technique and critically analyses the device.
Resumo:
Background Leg length inequality (LLI) was identified as a problem of total hip arthroplasty soon after its introduction. Leg lengthening is the most common form of LLI. Possible consequences are limping, neuronal dysfunction and aseptic component loosening. LLI can result in an increased strain both on the contralateral hip joint and on the abductor muscles. We assessed the influence of leg lengthening and shortening on walking capacity, hip pain, limping and patient satisfaction at 2-year follow-up. Methods 478 cases with postoperative lengthening and 275 with shortening were identified, and matched with three controls each. Rigorous adjustment for potential differences in baseline patient characteristics was performed by propensity-score matching of covariates. The arbitrarily defined desired outcomes were a walking capacity >60 minutes, no hip pain, no limping, and excellent patient satisfaction. Differences in not achieving the desired outcomes between the groups were expressed as odds ratios. Results In the lengthened case group, the odds ratio for not being able to walk for an hour was 1.70 (95% CI 1.28-2.26) for cases compared to controls, and the odds ratio for having hip pain at follow-up was 1.13 (95% CI 0.78-1.64). The odds ratio for limping was 2.08 (95% CI 1.55-2.80). The odds ratio for not achieving excellent patient satisfaction was 1.67 (95% CI 1.23-2.28). In the shortening case group, the odds ratio for not being able to walk for an hour was 1.23 (95% CI 0.84-1.81), and the odds ratio for having hip pain at follow-up was 1.60 (95% CI 1.05-2.44). The odds ratio for limping for cases was 2.61 (95% CI 1.78-3.21). The odds ratio for not achieving excellent patient satisfaction was 2.15 (95% CI 1.44-3.21). Conclusions Walking capacity, limping and patient satisfaction were all significantly associated with leg lengthening, whereas pain alleviation was not. In contrast, hip pain, limping and patient satisfaction were all significantly associated with leg shortening, whereas walking capacity was not.
Resumo:
Placing portal incisions during arthroscopic hip surgery presents challenges for surgeons in terms of anatomic accessibility and patient safety. Based on key anatomic landmarks and portal placement information from recent literature, suggested portal incisions were determined. Guidance in the placement of the three most common portal incision locations (anterior, anterolateral, and posterolateral) for arthroscopic surgery; in addition to visual feedback on tool trajectory to the hip joint is provided in real time by a computer aided system for hip arthroscopy. By simplifying the portal placement process, one of the most challenging aspects of arthroscopic hip surgery, an increased use of this minimally invasive technique could be possible. In addition to portal information, improvements to an existing computer aided system for arthroscopic hip surgery, including a new hip model and redesigned mechanical tracking linkage, were completed.
Resumo:
While beneficially decreasing the necessary incision size, arthroscopic hip surgery increases the surgical complexity due to loss of joint visibility. To ease such difficulty, a computer-aided mechanical navigation system was developed to present the location of the surgical tool relative to the patient¿s hip joint. A preliminary study reduced the position error of the tracking linkage with limited static testing trials. In this study, a correction method, including a rotational correction factor and a length correction function, was developed through more in-depth static testing. The developed correction method was then applied to additional static and dynamic testing trials to evaluate its effectiveness. For static testing, the position error decreased from an average of 0.384 inches to 0.153 inches, with an error reduction of 60.5%. Three parameters utilized to quantify error reduction of dynamic testing did not show consistent results. The vertex coordinates achieved 29.4% of error reduction, yet with large variation in the upper vertex. The triangular area error was reduced by 5.37%, however inconsistent among all five dynamic trials. Error of vertex angles increased, indicating a shape torsion using the developed correction method. While the established correction method effectively and consistently reduced position error in static testing, it did not present consistent results in dynamic trials. More dynamic paramters should be explored to quantify error reduction of dynamic testing, and more in-depth dynamic testing methodology should be conducted to further improve the accuracy of the computer-aided nagivation system.
Resumo:
For smart applications, nodes in wireless multimedia sensor networks (MWSNs) have to take decisions based on sensed scalar physical measurements. A routing protocol must provide the multimedia delivery with quality level support and be energy-efficient for large-scale networks. With this goal in mind, this paper proposes a smart Multi-hop hierarchical routing protocol for Efficient VIdeo communication (MEVI). MEVI combines an opportunistic scheme to create clusters, a cross-layer solution to select routes based on network conditions, and a smart solution to trigger multimedia transmission according to sensed data. Simulations were conducted to show the benefits of MEVI compared with the well-known Low-Energy Adaptive Clustering Hierarchy (LEACH) protocol. This paper includes an analysis of the signaling overhead, energy-efficiency, and video quality.