989 resultados para Hemorragia na fossa posterior


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare the effects of active and passive lacebacks on antero-posterior position of maxillary first molars and central incisors during leveling phase. Twenty-three subjects with Class I and Class II malocclusion were treated with first premolars extraction using preadjusted appliances (MBT 0.022-inch brackets). The leveling phase was performed with stainless steel archwires only. The sample was divided into 2 groups: 14 subjects received active lacebacks (Group 1) and 9 subjects received passive lacebacks (Group 2). Lacebacks were made from 0.008-inch ligature wire. Lateral cephalometric radiographs were taken pre- and post-leveling phase. Student's t-test was applied to determine the differences between pre- and post-leveling mean values and to determine the mean differences between groups. In Group I, the first molars showed a significant mesial movement, whereas no change was observed in Group 2. In both groups, maxillary central incisor crowns moved to lingual side. In conclusion, active laceback produced anchorage loss of maxillary first molars whereas passive laceback did not affect the position of these teeth. Active and passive lacebacks were effective in preventing central incisor proclination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To verify if there is difference in the buccal and posterior corridor width in cases treated with extraction of one and four premolars. METHODS: Through posed smile photographs of 23 Class II patients, subdivision, treated with extraction of one premolar and 25 Class I and Class II patients, subdivision, treated with extraction of four premolars, the percentage of buccal and posterior corridor width was calculated. The two protocols of extractions were compared regarding the buccal and posterior corridor width by independent t tests. RESULTS: There was no statistically significant difference on the buccal and posterior corridor widths between patients treated with symmetric and asymmetric extraction. CONCLUSION: The buccal and posterior corridor did not differ between the evaluated protocols of extractions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: A reposição volêmica em pacientes traumatizados tem sido controvérsa. O A.T.L.S. recomenda a infusão de um grande volume de fluidos na fase inicial de tratamento, enquanto outros autores recomendam a administração somente quando do controle da hemorragia. O acesso venoso femoral é contra indicado em pacientes com trauma abdominal por temor de aumento de hemorragia. A solução hipertônica de NaCl a 7,5% (SH) possui benefícios consideráveis de logística e de recuperação hemodinâmica com pequenos volumes de infusão, semelhante as vantagens das soluções padrões isotônicas na fase pré-hospitalar. Objetivos: Criar um modelo de choque hemorrágico induzido por trauma venoso. Avaliar a hemodinâmica e o volume de hemorragia abdominal nos animais submetidos a choque hemorrágico e tratados com SH via acesso femoral e jugular. Métodos: Em 18 porcos da raça landrace, divididos em 3 grupos de 6 animais (Controle, Jugular e Femoral), foi induzido um choque hipovolêmico não controlado pela ruptura da veia cava caudal. Os animais do grupo controle (GC) foram observados por 40 minutos quanto ao seu padrão hemodinâmico de Pressão de Artéria Pulmonar (PAP), Pressão Artérial Média (PAM), Débito Cardíaco (DC) e Fluxo de Veia Porta (FVP), porém sem reposição volêmica. Os animais dos grupos Femoral (GC) e Jugular (GJ) foram tratados com 4 ml/Kg de solução hipertônica de NaCl a 7,5% (SH) aos 20 minutos de experimento. Ao final do experimento, o volume de hemorragia abdominal foi mensurado.Resultados: O grupo controle (GC) apresentou queda dos valores hemodinâmicos aos 10 minutos e estes permaneceram estáveis até o final do experimento. Os animais dos grupos tratamento (GF e GJ) apresentaram melhora da hemodinâmica aos 30 minutos, sem aumento da hemorragia abdominal. Conclusão: A solução hipertônica de NaCl (SH) permitiu a melhora parcial da hemodinâmica no modelo de choque hipovolêmico, sem aumento da hemorragia, independentemente do acesso utilizada para a infusão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Programa de doctorado: La recepción del Derecho Comunitario Europeo en el Derecho Interno Español

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cerebellar malformation are increasingly diagnosed in utero. To assess the effectiveness of ultrasound and fetal magnetic resonance in the antenatal prediction of long term neurodevelopmental delay. STUDY DESIGN: We collected 105 cases of cerebellum malformation in the period 2000-2010 in Bologna and Bari University. Classification included cystic anomalies of posterior fossa and cerebellar hypoplasia. RESULTS: The greater group included Blake’s pouch cysts and mega cisterna magna cases (58/105). These cases seemed to have a good prognosis with a good outcome both in association with other anomalies and isolated. In cases of Dandy Walker malformation, vermis hypoplasia and cerebellum hypoplasia there were few survivors, so it was so difficult to outline some conclusion for child outcome. Despite great neuroimaging advances, in our study, ultrasound and MR reached a similar sensitivity (62-63%) for the diagnosis of posterior fossa anomalies, but the number of MR was lower compared with ultrasonography. CONCLUSION: Ultrasonography remains the screening method of choice for evaluation of cerebellum anatomy but probably MR imaging can improve some details expecially in the third trimester. Despite the data on Dandy Walker, vermis hypoplasia and cerebellum hypoplasia were conflicting and uncertain, for Blake and mega cisterna magna we can considered a rather good outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work takes into account three posterior parietal areas, V6, V6A, and PEc, all operating on different subsets of signals (visual, somatic, motor). The work focuses on the study of their functional properties, to better understand their respective contribution in the neuronal circuits that make possible the interactions between subject and external environment. In the caudalmost pole of parietal lobe there is area V6. Functional data suggest that this area is related to the encoding of both objects motion and ego-motion. However, the sensitivity of V6 neurons to optic flow stimulations has been tested only in human fMRI experiments. Here we addressed this issue by applying on monkey the same experimental protocol used in human studies. The visual stimulation obtained with the Flow Fields stimulus was the most effective and powerful to activate area V6 in monkey, further strengthening this homology between the two primates. The neighboring areas, V6A and PEc, show different cytoarchitecture and connectivity profiles, but are both involved in the control of reaches. We studied the sensory responses present in these areas, and directly compared these.. We also studied the motor related discharges of PEc neurons during reaching movements in 3D space comparing also the direction and depth tuning of PEc cells with those of V6A. The results show that area PEc and V6A share several functional properties. Area PEc, unlike V6A, contains a richer and more complex somatosensory input, and a poorer, although complex visual one. Differences emerged also comparing the motor-related properties for reaches in depth: the incidence of depth modulations in PEc and the temporal pattern of modulation for depth and direction allow to delineate a trend among the two parietal visuomotor areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates 3-year success rates of titanium screw-type implants with a chemically modified sandblasted and acid-etched surface (mod SLA), which were functionally loaded after 3 weeks of healing. METHODS: A total of 56 implants, inserted in the posterior mandibles of 39 partially edentulous patients, underwent undisturbed healing for 3 weeks. At day 21, the implants were fully loaded with provisional crowns. Definitive metal ceramic restorations were fabricated after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 36 months after implant placement. The soft tissue and radiographic parameters for the mod SLA implants after 3 years in function were compared to a historic control group of implants with an SLA surface using an early loading protocol after 6 weeks. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and were left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants, including the "spinners," showed favorable clinical and radiographic findings at the 3-year follow-up examination. All 56 implants were considered successfully integrated, resulting in a 3-year survival and success rate of 100%. Dental implants with a mod SLA surface demonstrated statistically significant differences for probing depths and clinical attachment level values compared to the historic control group, with the mod SLA surface implants having overall lower probing depths and clinical attachment level scores. CONCLUSION: This prospective study using an early loading protocol demonstrates that titanium implants with the mod SLA surface can achieve and maintain successful tissue integration over a period of 3 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physicians treating patients with posterior circulation strokes (PCS) tended to debate more on whether or not to introduce anticoagulation rather than performing investigations to identify stroke aetiology, as in patients with anterior circulation strokes (ACS). Recent findings suggest that stroke aetiologies of PCS and ACS are more alike than dissimilar, suggesting that PCS deserve the same investigations as ACS. The characteristics and current diagnostic evaluation between patients with PCS and ACS were compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to report the ability of a magnetic resonance image to document the integrity of the obturator externus tendon after posterior hip dislocation as a potential predictor for preserved femoral head vascularity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply.