940 resultados para Heating plants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effect of aqueous leaf extracts of Catheranthus roseus, Calotropis gigantium and Datura stromoneum on common carp, Cyprinus carpio were investigated. C. carpio were separately fed with 1 and 2% aqueous extracts of these three plant leaves for a period of seven days. In 1% Catheranthus roseus of leaf extract fed group no significant tissue level changes were recorded. One and 2% of other two species fed treated group showed mild to severe necrotic and cellular changes in liver, kidney and spleen. Immunologically, significant rise in antibody titre and respiratory burst activity was recorded for 1% Catheranthus roseusfed group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The function of plant genomes depends on chromatin marks such as the methylation of DNA and the post-translational modification of histones. Techniques for studying model plants such as Arabidopsis thaliana have enabled researchers to begin to uncover the pathways that establish and maintain chromatin modifications, and genomic studies are allowing the mapping of modifications such as DNA methylation on a genome-wide scale. Small RNAs seem to be important in determining the distribution of chromatin modifications, and RNA might also underlie the complex epigenetic interactions that occur between homologous sequences. Plants use these epigenetic silencing mechanisms extensively to control development and parent-of-origin imprinted gene expression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extent of idle capacity in fish processing (freezing) plants estimated by stratified random sampling is reported. The estimates for 1978 and 1979 for the processing plants on the west coast of India were 76.9 % and 73.2 % respectively at the rate of 250 working days per annum and two shifts per day. The percentage error of estimates worked out to 6.04 for 1978 and 6.98 for 1979. Substantial under utilization of processing plants noticed in all the states accounts mainly to the non-availability of raw material (prawn), high cost of production and shortage of power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extent of idle capacity in the fish processing (freezing) plants in the east coast of India estimated by stratified random sampling and the factors responsible for the same are reported. The estimates of idle capacity of fish processing plants in the east coast for the years 1978 and 1979 were respectively 75.9% and 72.5% on the basis of 250 working days per annum and double shift per day. The percentage errors of estimates worked out to 6.9 for 1978 and 4.7 for 1979. The corresponding figures were worked out on the basis of 200 working days also. Substantial under-utilisation of plants in all the maritime states in the east coast accounted mainly to non-availability of raw material, high cost of production, shortage of power, scarcity of ice and potable water during peak season and frequent labour troubles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The shrimp processing plants located at any particular place receive their raw material supplies from local and outside centres. The raw material received, the form in which it was received, the relative contribution by local and outside centres and the seasonal variation in the supplies were studied with respect to the shrimp processing plants located at three places - Cochin, Veraval and Kakinada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Building integrated photovoltaics (BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influence on the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. Four different roofs are used to assess the impacts of BIPV on the building's heating-and-cooling loads; namely ventilated air-gap BIPV, non-ventilated (closed) air-gap BIPV, closeroof mounted BIPV, and the conventional roof with no PV and no air gap. One-dimensional transient models of four cases are derived to evaluate the PV performances and building cooling-and-heating loads across the different roofs in order to select the appropriate PV building integration method in Tianjin, China. The simulation results show that the PV roof with ventilated air-gap is suitable for the application in summer because this integration leads to the low cooling load and high PV conversion efficiency. The PV roof with ventilation air-gap has a high time lag and small decrement factor in comparison with other three roofs and has the same heat gain as the cool roof of absorptance 0.4. In winter, BIPV of non-ventilated air gap is more appropriate due to the combination of the low heating-load through the PV roof and high PV electrical output. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is potential to extract energy from wastewater in a number of ways, including: kinetic energy using micro-hydro systems, chemical energy through the incineration of sludge, biomass energy from the biogas produced after anaerobic sludge digestion, and thermal energy as heat. This paper considers the last option and asks how much heat could be recovered under UK climatic conditions and can this heat be used effectively by wastewater treatment plants to reduce their carbon footprint? Four wastewater treatment sites in southern England are investigated and the available heat that can be recovered at those sites is quantified. Issues relating to the environmental, economic and practical constraints on how energy can be realistically recovered and utilised are discussed .The results show there is a definite possibility for thermal energy recovery with potential savings at some sites of up to 35,000 tonnes of total long-cycle carbon equivalent (fossil fuel) emissions per year being achievable. The paper also shows that the financial feasibility of three options for using the heat (either for district heating, sludge drying or thermophilic heating in sludge digestion processes) is highly dependant upon the current shadow price of carbon. Without the inclusion of the cost of carbon, the financial feasibility is significantly limited. An environmental constraint for the allowable discharge temperature of effluent after heat-extraction was found to be the major limitation to the amount of energy available for recovery. The paper establishes the true potential of thermal energy recovery from wastewater in English conditions and the economic feasibility of reducing the carbon footprint of wastewater treatment operations using this approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser-assisted cold spray (LCS) is a new coating and fabrication process which combines some advantages of CS: solid-state deposition, retain their initial composition and high build rate with the ability to deposit materials which are either difficult or impossible to deposit using cold spray alone. Stellite 6 powder is deposited on medium carbon steels by LCS using N 2 as carrier gas pressure. The topography, cross section thickness, structure of the coatings is examined by SEM, optical microscopy, EDX. The results show that thickness and fluctuation of coating are improved with increased deposition site temperature. Porosity of coating is affected by N 2 and deposition site temperature. In this paper, it presents optimal coating using N 2 at a pressure of 3 MPa and temperature of 450°C and deposition site temperature of 1100°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To extract gas from hydrate reservoirs, it has to be dissociated in situ. This endothermic dissociation process absorbs heat energy from the formation and pore fluid. The heat transfer governs the dissociation rate, which is proportional to the difference between the actual temperature and the equilibrium temperature. This study compares three potential gas production schemes from hydrate-bearing soil, where the radial heat transfer is governing. Cylindrical samples with 40% pore-filling hydrate saturation were tested. The production tests were carried out over 90 min by dissociating the hydrate from a centered miniature wellbore, by either lowering the pressure to 6, 4, or 6 MPa with simultaneous heating of the wellbore to 288 K. All tests were replicated by a numerical simulation. With additional heating at the same wellbore pressure, the gas production from hydrates could, on average, be increased by 1.8 and 3.6 times in the simulation and experiments, respectively. If the heat influx from the outer boundary is limited, a simulation showed that the specific heat of the formation is rapidly used up when the wellbore is only depressurized and not heated. © 2012 American Chemical Society.