872 resultados para Graphite tubes
Resumo:
1st ASPIC International Congress
Resumo:
This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.
Resumo:
III Jornadas de Electroquímica e Inovação (Electroquímica e Nanomateriais), na Universidade de Trás-os-Montes e Alto Douro, Vila Real, 16 a 17 de Setembro de 2013
Resumo:
Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013
Resumo:
A furazolidona é uma substância ativa do medicamento Giarlam que contém um espetro anti-bacteriano relativamente amplo e que é frequentemente usado para tratar certas doenças bacterianas e protozoárias no homem. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabólitos exige o desenvolvimento constante de métodos analíticos eficientes. Neste trabalho desenvolveu-se um novo sensor eletroquímico para a deteção da furazolidona, baseado num elétrodo de pasta de carbono modificado com um polímero molecularmente impresso. A procura de novos materiais que permitam uma melhor seletividade e sensibilidade aos sistemas de deteção é especialmente importante no desenvolvimento de métodos analíticos. Os polímeros molecularmente impressos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais frequente como ferramenta importante em química analítica. Assim, sintetizou-se um polímero com cavidades seletivas para a Furazolidona. Este polímero foi, misturado com grafite e perafina de modo a produzir uma pasta de carbono. Uma seringa de plástico foi usada como suporte da pasta de carbono. O comportamento eletroquímico do sensor foi avaliado e diversas condições de utilização foram estudadas e otimizadas. O sensor apresenta um comportamento linear entre a intensidade do pico e a concentração numa gama de concentrações entre 1 e 100 μM, um limite de deteção de 1 μM e uma precisão (repetibilidade) inferior a 7%. A aplicabilidade do sensor fabricado em amostras complexas foi avaliada pela deteção do fármaco em amostras de urina.
Resumo:
Since there are no studies evaluating the participation of the complement system (CS) in Jorge Lobo's disease and its activity on the fungus Lacazia loboi, we carried out the present investigation. Fungal cells with a viability index of 48% were obtained from the footpads of BALB/c mice and incubated with a pool of inactivated serum from patients with the mycosis or with sterile saline for 30 min at 37 ºC. Next, the tubes were incubated for 2 h with a pool of noninactivated AB+ serum, inactivated serum, serum diluted in EGTA-MgCl2, and serum diluted in EDTA. The viability of L. loboi was evaluated and the fungal suspension was cytocentrifuged. The slides were submitted to immunofluorescence staining using human anti-C3 antibody. The results revealed that 98% of the fungi activated the CS by the alternative pathway and no significant difference in L. loboi viability was observed after CS activation. In parallel, frozen histological sections from 11 patients were analyzed regarding the presence of C3 and IgG by immunofluorescence staining. C3 and IgG deposits were observed in the fungal wall of 100% and 91% of the lesions evaluated, respectively. The results suggest that the CS and immunoglobulins may contribute to the defense mechanisms of the host against L. loboi.
Resumo:
The aim of this study was to verify the possibility to use a polarized graphite electrode as an electron donor for the reductive dechlorination of 1,2-dichloroethane, an ubiquitous groundwater contaminant. The rate of 1,2-DCA dechlorination almost linearly increased by decreasing the set cathode potential over a broad range of set cathode potentials (i.e., from −300 mV to −900 mV vs. the standard hydrogen electrode). This process was primarily dependent on electrolytic H2 generation. On the other hand, reductive dechlorination proceeded (although quite slowly) with a very high Coulombic efficiency (near 70%) at a set cathode potential of −300 mV, where no H2 production occurred. Under this condition, reductive dechlorination was likely driven by direct electron uptake from the surface of the polarized electrode. Taken as a whole, this study further extends the range of chlorinated contaminants which can be treated with bioelectrochemical systems.
Resumo:
Overview and Aims: Female sterilization is increasingly requested as a contraceptive method. Hysteroscopic sterilization by transcervical placing of Essure® micro-inserts in the initial portion of the tubes is a recent alternative to laparoscopic sterilization. The objective of this study is to evaluate the safety and effectiveness of hysteroscopic versus laparoscopic sterilization. Study Design: Retrospective cohort study. Population: A total of 98 women undergoing sterilization in an outpatient clinic between July 2005 and July 2009. Methods: Patients’ age, associated diseases, anesthesic risk, procedure time, discomfort, adverse events and success rate were evaluated. Results: Mean age at surgery was 37.8 years (19-49), and there were no statistically significant differences between the groups regarding this parameter. Women in the hysteroscopic group had a significant number of associated diseases (98% versus 47%), obesity (31% versus 6%), and anesthesic risk (ASA III- 31% versus 0%). The mean duration of the procedure was the same for both techniques (laparoscopy 28 minutes and hysteroscopy 26 minutes). All laparoscopic sterilizations were successfully completed. In the hysteroscopic group 4% failed to complete the technique. There were no cases of severe pain. Women in the hysteroscopy group reported pain less frequently (40% versus 57%, χ2 p<0.05). Long term success rate was similar in both groups (96% for hysteroscopy and 98% for laparoscopy). Conclusions: In spite of a higher incidence of associated diseases, obesity and anesthetic risks in the hysteroscopy group, there were no significant differences in the duration of the procedure, adverse events and success rate. The hysteroscopic approach can therefore be considered an alternative to laparoscopy, eliminating the need for incisional surgery and for general anaesthesia. If women with high surgical risk and several associated diseases can safely undergo this procedure, it could well become the preferred method for women who want a permanent and irreversible contraceptive method.
Resumo:
The complex interaction between hepatitis C virus infection, iron homeostasis and the response to antiviral treatment remains controversial. The aim of this study was to evaluate the influence of hepatic iron concentration (HIC) on the sustained virological response (SVR) to antiviral therapy in patients with chronic hepatitis C. A total of 50 patients who underwent pretreatment liver biopsy with assessment of HIC by graphite furnace atomic absorption spectroscopy and were subsequently submitted to antiviral treatment with interferon/peginterferon and ribavirin were included in the study. Patients with alcoholism, history of multiple blood transfusion, chronic kidney disease, hemolytic anemia and parenteral iron therapy were excluded. The iron related markers and HIC were compared between those who achieved an SVR and non-responders (NR) patients. The mean age was 45.7 years and the proportion of patients' gender was not different between SVR and NR patients. The median serum iron was 138 and 134 µg/dL (p = 0.9), the median serum ferritin was 152.5 and 179.5 ng/mL (p = 0.87) and the median HIC was 9.9 and 8.2 µmol/g dry tissue (p = 0.51), for SVR and NR patients, respectively. Thus, hepatic iron concentration, determined by a reliable quantitative method, was not a negative predictive factor of SVR in patients with chronic hepatitis C presenting mild to moderate hepatic iron accumulation.
Resumo:
Introduction: Heterotopic pregnancy (HP) is defined as two gestational sacs simultaneously present in two different locations, being the uterus and the fallopian tubes the more common. Sporadic HP is a very rare condition (1:30,000 pregnancies). With the use of medically assisted reproduction the prevalence is significantly higher(1:7,000). Considering spontaneous pregnancy, HP is associated with risk factors, being prior inflammatory pelvic disease the most common. The clinical presentation is similar to that of ectopic pregnancy or spontaneous miscarriage although it is usually a more late diagnosis. Case report: 25 year-old pregnant woman, OI 0000, previously healthy; admitted at the Emergency Department (ED) with acute pelvic pain mainly at the right iliac fossa and moderate vaginal bleeding confirmed by speculum examination. She was hemodynamically stable and the bimanual palpation was painful; no prior medically assisted reproduction technique had been performed. The haemoglobin value was within normal range and the serum β-hCG was 2,763mUI/mL. The ultrasonography at the ED showed an in uterus gestational sac and another one inside the right fallopian tube; in both gestational sacs cardiac activity was absent. HP diagnosis was then established and the patient was admitted at the Obstetrics Ward for surveillance and ultrasonographic/laboratorial reassessment; complete miscarriage of the uterine pregnancy occurred but methotrexate was necessary for the treatment of persistent tubarian pregnancy. Conclusion: When evaluating a pregnant woman with pelvic pain and vaginal bleeding one should always be aware of several differential diagnosis amongst which HP should be considered. If the patient has in uterus viable pregnancy the treatment of the ectopic concomitant gestational sac should be as conservative as possible; methotrexate should not be used in that situation as it leads to uterine pregnancy miscarriage in about one third of the patients.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
As células foto voltaicas orgânicas ou células de Gräetzel (depois do seu descobridor) são aparelhos para a colecta de energia solar que utilizam um semicondutor inorgânico e uma molécula orgânica. Dita molécula orgânica é capaz de excitar-se na presença de radiação electromagnética e ceder esta energia através da doação de electrões a este semicondutor. Embora estas estruturas e o seu processo de fabrico sejam relativamente pouco onerosas, o aproveitamento da energia solar é ainda muito baixo. Para além desta deficiência, os corantes sintéticos sofrem de “bleaching” ou então são reduzidos ou oxidados facilmente quando não conseguem transferir a energia que foi absorvida ou quando é difícil voltar ao estado original por dificuldades no completamento de circulação de electrões. Neste trabalho pretende-se então estudar o comportamento de moléculas e misturas complexas de moléculas com capacidade para serem excitadas pela luz solar. Como a dita xcitação promove a transferência de um electrão, este processo será seguido pela técnica de Voltametria cíclica. Como substâncias absorventes de luz utilizaremos compostos naturais (principalmente flavonóides) puros, ou então na forma de complexos naturais extraídos de algumas plantas. Estas misturas de corantes serão extractos aquosos (infusões) de casca de laranja e limão assim como extractos de folhas de cerejeira, com o objectivo de proporcionar lternativas aos flavonóides utilizados neste estudo. A caracterização voltamétrica desta célula é feita em diferentes formas de iluminação. Sobre a célula assim formada faz-se incidir rimeiro luz de lâmpadas fluorescentes, depois luz ultra violeta e por fim sem qualquer tipo de luz incidente. Na base do fabrico da variante mais clássica destas células está o semicondutor óxido de itânio (TiO2), por ser uma substância muito comum e barata e com propriedades semicondutoras notáveis. Uma forma comum de melhorar a eficiência deste material é introduzir dopantes com o intuito de melhorar a eficiência do processo de transferência electrónica. Um segundo objectivo deste trabalho é o estudo de sistemas semicondutor/molécula foto activa. Semicondutores como ZnO, TiO2 e TiO2 dopado serão então estudados. O gels de TiO2 ou o TiO2 dopado serão depositados sobre lâminas de vidro comum, nas quais foi anteriormente depositado uma película de alumínio que serve de condutor (eléctrodo egativo). Uma outra variante será a utilização de óxido de zinco, um semicondutor de baixo custo que por sua vez vai ser depositado em lâminas de alumínio comercial. A nossa célula foto electroquímica será então formada por moléculas de corante, uma lâmina e um semicondutor (que funcionará como eléctrodo de trabalho), com ou sem electrólito/catalizador (solução de iodo/iodeto), e eléctrodos de referência de Ag/AgCl, e outro auxiliar de grafite. Um outro objectivo é fazer um pequeno estudo sobre influencia do catalisador I2/etilenodiamina no comportamento electroquímico da célula, de forma a poder utilizar o solvente (etilenodiamina) com menor volatilidade do que a água, que é empregada no par I2/I3.m A importância deste facto prende-se com a limitada vida destas células quando o electrólito/solvente é evaporado pelas altas temperaturas da radiação incidente.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
Sandflies transmit pathogens of leishmaniasis. The natural infection of sandflies by Leishmania (Viannia) was assessed in municipalities, in the state of Paraná, in Southern Brazil. Sandflies were collected with Falcão and Shannon traps. After dissection in search of flagellates in digestive tubes and identification of the species, female sandflies were submitted to the Multiplex Polymerase Chain Reaction (multiplex PCR) for detection of the fragment of the kDNA of Leishmania (Viannia) and the fragment from the IVS6 cacophony gene region of the phlebotomine insects. The analysis was performed in pools containing seven to 12 guts from females of the same species. A total of 510 female sandflies were analyzed, including nine Migonemyia migonei, 17 Pintomyia fischeri, 216 Nyssomyia neivai, and 268 Nyssomyia whitmani. Although none of the females was found naturally infected by flagellates through dissection, the fragment of DNA from Leishmania (Viannia) was shown by multiplex PCR in one sample of Ny. neivai (0.46%) and three samples of Ny. whitmani (1.12%). It was concluded that Ny. neivai and Ny. whitmani are susceptible to Leishmania infection, and that multiplex PCR can be used in epidemiological studies to detect the natural infection of the sandfly vector, because of its sensitivity, specificity and feasibility.
Resumo:
O presente trabalho centrou-se na otimização do rendimento térmico de duas caldeiras aquatubulares da empresa RAR- Refinaria de Açúcar Reunidas, com a finalidade de identificar onde ocorrem perdas de energia e, desta forma, propor soluções para a sua minimização. Para tal, realizaram-se ensaios em duas caldeiras da empresa providas de queimadores mistos, ou seja podem operar com fuelóleo e gás natural, tanto individualmente, como simultaneamente, sendo que para a realização dos ensaios apenas se utilizou o fuelóleo devido ao seu menor custo. Na caldeira designada por 1 realizaram-se ensaios para os caudais de 300, 500, 800, 1000, 1200, 1400 e 1600 kg/h de fuelóleo. A gama de rendimentos térmicos obtida foi entre 88,3 e 91,2%. Na caldeira designada por 3, efetuaram-se ensaios para os caudais de fuelóleo de 300, 500, 700, 900, 1000, 1200, 1400, 1500 e 1800 kg/h e os rendimentos térmicos obtidos foram entre 85,2 e 88,0%. Em ambas as caldeiras e para caudais baixos verificou-se que a quantidade de ar introduzida no processo de combustão era superior à necessária, conduzindo a uma diminuição dos valores de rendimento térmico. Para 500 kg/h de fuelóleo, por exemplo, a quantidade de ar utilizada foi cerca de duas vezes superiores ao valor estequiométrico. Tendo em conta estes factos, foi proposto ao gestor de energia a implementação de uma nova relação de ar/combustível vs caudal de combustível no sistema de controlo das referidas caldeiras. Após alguns testes (excluindo 300 kg/h de fuelóleo devido a questões de operação), considerou-se como caudal mínimo de operação os 500 Kg/h de fuelóleo nas respetivas caldeiras 1 e 3. Verificou-se que os rendimentos térmicos aumentaram, no caso da caldeira 1, para valores entre os 90,1 e 91,3% e, na caldeira 3, para valores entre 89,0 e 90,9%. Por fim, efetuou-se uma breve análise económica com o intuito de se avaliar e quantificar o que a empresa pode poupar com esta medida. O lucro anual pode oscilar entre 14.400 e 62.640€ ou 104.400 e 136.800€, para as caldeiras 1 e 3, respetivamente.