945 resultados para Gel 2D


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxide type spinel AB2O4 presents structure adjusted for application in the automobile industry. The spinel of cobalt has many practical applications had its excellent physical and chemical properties such as catalyst in hydrocarbon oxidation reaction. The CeO2 has been used in many of these processes because it assigns to a material with excellent thermal resistance and mechanics, high capacity of oxygen stockage (OSC) among others properties. This work deals with the synthesis, characterization and catalytic application of spinel of cobalt and CeO2 with fluorita structure, obtained for method of Pechini and method of Gel-Combustion. The process of Pechini, the puff was obtained at 300 ºC for 2 h in air. In the process of Gel-Combustion the approximately at 350 ºC material was prepared and burnt for Pyrolysis, both had been calcined at 500 ºC, 700 ºC, 900 ºC and 1050 ºC for 2 h in air. The materials of the calcinations had been characterized by TG/DTA, electronic microscopy of sweepings (MEV), spectroscopy of absorption in the infra-red ray (FTIR) and diffraction of X-rays (DRX). The obtained material reaches the phase oxide at 450 oC for Pechini method and 500 °C for combustion method. The samples were submitted catalytic reaction of n-hexane on superficies of materials. The reactor function in molar ration of 0, 85 mol.h-1.g-1 and temperature of system was 450 °C. The sample obtained for Pechini and support in alumine of superficial area of 178,63 m2.g-1 calcined at 700 ºC, give results of catalytic conversions of 39 % and the sample obtained for method of gel-combustion and support in alumina of 150 mesh calcined at 500 ºC result 13 % of conversion. Both method were selective specie C1

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Hydrocarbon exploration activities, the great enigma is the location of the deposits. Great efforts are undertaken in an attempt to better identify them, locate them and at the same time, enhance cost-effectiveness relationship of extraction of oil. Seismic methods are the most widely used because they are indirect, i.e., probing the subsurface layers without invading them. Seismogram is the representation of the Earth s interior and its structures through a conveniently disposed arrangement of the data obtained by seismic reflection. A major problem in this representation is the intensity and variety of present noise in the seismogram, as the surface bearing noise that contaminates the relevant signals, and may mask the desired information, brought by waves scattered in deeper regions of the geological layers. It was developed a tool to suppress these noises based on wavelet transform 1D and 2D. The Java language program makes the separation of seismic images considering the directions (horizontal, vertical, mixed or local) and bands of wavelengths that form these images, using the Daubechies Wavelets, Auto-resolution and Tensor Product of wavelet bases. Besides, it was developed the option in a single image, using the tensor product of two-dimensional wavelets or one-wavelet tensor product by identities. In the latter case, we have the wavelet decomposition in a two dimensional signal in a single direction. This decomposition has allowed to lengthen a certain direction the two-dimensional Wavelets, correcting the effects of scales by applying Auto-resolutions. In other words, it has been improved the treatment of a seismic image using 1D wavelet and 2D wavelet at different stages of Auto-resolution. It was also implemented improvements in the display of images associated with breakdowns in each Auto-resolution, facilitating the choices of images with the signals of interest for image reconstruction without noise. The program was tested with real data and the results were good

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2-Aminothiazole covalently attached to a silica gel surface was prepared in order to obtain an adsorbent for Hg(II) ions having the following characteristics: good sorption capacity, chemical stability under conditions of use, and, especially, high selectivity. The accumulation voltammetry of mercury(II) was investigated at a carbon paste electrode chemically modified with silica gel functionalized with 2-aminothiazole (SIAMT-CPE). The repetitive cyclic voltammogram of mercury(II) solution in the potential range -0.2 to + 0.6 V versus Ag/AgCl (0.02 mol L-1 KNO3; V = 20 mV s(-1)) show two peaks one at about 0.1 V and other at 0.205 V. The anodic wave peak at 0.205 V is well defined and does not change during the cycles and it was therefore further investigated for analytical purposes using differential pulse anodic stripping voltammetry in differents supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. The precision for six determinations (n = 6) of 0.02 and 0.20 mg L-1 Hg(II) was 4.1 and 3.5% (relative standard deviation), respectively. The detection limit was estimated as 0.10 mu g L-1 mercury(II) by means of 3:1 current-to-noise ratio in connection with the optimization of the various parameters involved and using the highest-possible analyser sensitivity. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The serum protein concentration of newborn Holstein calves determined by means of sodium dodecyl sulphate-polyacrylamide (SDS-PAGE) was studied. Blood samples from 40 healthy newborn calves were obtained 48 hours after birth. Calves had been given 3 liters of colostrum within 2 hours after birth, following by dose corresponding by 15% of animal weight each 24 hours. The results showed three different proteinograms: 19 calves had 14 proteins with molecular weights (MW) ranging from 28,000 D to 170,000D (proteinogram 1); 11 calves had 14 proteins with MW ranging from 18,000 to 170,000 D (proteinogram 1); and 10 calves had 12 proteins with MW ranging from 28,000 D to 170,000 D (proteinogram 3). The three groups presented similar IgG levels. The highest serum concentration of ceruloplasmin were verified in proteinogram 3, which had the lowest serum level of protein with MW 58,000D. It was verified a1-antitrypsin only in proteinogram 2, which had no proteins with MW of 42,000 D and 37,000D. The highest serum concentrations of IgA and protein with MW 58,000 D, and the lowest serum levels of transferrin, haptoglobin, and acid glycoprotein were verified in proteinogram 3. Measurement of serum protein concentrations by SDS-PAGE may be useful in monitoring the occurrence of hypogammaglobulinemia and the neonatal disease in calves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram avaliadas amostras de soro sanguíneo de 10 cães sadios e de 12 com linfoma, utilizando-se a eletroforese em gel de poliacrilamida contendo dodecil sulfato de sódio. Houve diferença entre as médias dos teores de proteína total de cães sadios, 7,68g/dL±0,46 e de cães com linfoma, 7,93g/dL±2,49. As concentrações de IgA e IgG não foram diferentes entre os grupos. Os teores das proteínas de pesos moleculares 142000, 110000, 52000, 49000, 24000 e 18000 dáltons foram mais elevados em cães com linfoma. Os cães com linfoma apresentaram concentrações mais elevadas de ceruloplasmina, 43,95mg/dL±18,19, e haptoglobina, 554mg/dL±449,51, e menores de albumina, 2908mg/dL±476,67, em comparação aos cães sadios (ceruloplasmina: 3,42mg/dL±7,44; haptoglobina: 94,54mg/dL±59,50 e albumina: 4207mg/dL±206,18). Conclui-se que concentrações séricas mais elevadas de ceruloplasmina e haptoglobina e menores de albumina podem estar associadas ao linfoma em cães.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming to evaluate the puerperal influence on the proteinogram of Saanen goats, 108 samples of blood serum from 12 goats were collected, and the results were presented at nine times: just after parturition, 1, 3, 5, 7, 10, 15, 21 and 30 days after parturition. Total amount of serum proteins were determined by the biuret technique, and the sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) was used to the protein fractionation. In this last method, 17 protein bands were observed, from which molecular weights varied between 25 KDa and 275 KDa. In addition, it was possible to identify the following protein fractions: immunoglobulin A (180 KDa), ceruloplasmin (115 KDa), transferrin (79 KDa), albumin (65 KDa), heavy-chain immunoglobulin G (58 KDa), haptoglobin (45 KDa), acid glycoprotein (37 KDa) and light-chain immunoglobulin G (28 KDa). Another 9 nonidentified protein fractions presented, each molecular weights equal to 275 KDa, 140 KDa, 125 KDa, 103 KDa, 95 KDa, 41 KDa, 35 KDa, 30 Kda and 25 KDa. The results allow us to conclude that by the first week of puerperium, an improvement of acid glycoprotein occurs, whereas those others protein fractions do not suffer any puerperal influence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances have accelerated the development of biosensors for the analysis of specific gene sequences. In this kind of biosensor, a DNA probe is immobilized on a transducer and the hybridization with the target DNA is monitored by suitable methodology. In the present work, the streptavidin (STA) was encapsulated in thin films siloxane-poly(propylene oxide) hybrids prepared by sol-gel method and deposited on the graphite electrode surface by dip-coating process. Biotinylated 18-mer probes were immobilized through STA and a novel amperometric DNA biosensor for the detection and genotyping of the hepatitis C virus (genotypes 1, 2A/C, 2B and 3) is described. The HCV RNA from serum was submitted to reverse transcriptase-linked polymerase chain reaction (RT-PCR) and biotin-labeled cDNA was obtained. Thus, the cDNA was hybridized to the target-specific oligonucleotide probe immobilized on the graphite electrode surface and following the avidin-peroxidase conjugate was added. The enzymatic response was investigated by constant potential amperometry at -0.45 V versus Ag/AgCl using H2O2 and KI solutions. HCV RNA negative and positive controls and positive samples of sera patients were analyzed and the results were compared to commercial kit. The proposed methodology appeared to be suitable and convenient tool for streptavidin immobilization and diagnose of HCV disease. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoluminescence data of Eu-doped SnO(2) xerogels are presented, yielding information on the symmetry of Eu(3+) luminescent centers, which can be related to their location in the matrix: at lattice sites, substituting to Sn(4+), or segregated at particles surface. Influence of doping concentration and/or particle size on the photoluminescence spectra obtained by energy transfer from the matrix to Eu(3+) sites is investigated. Results show that a better efficiency in the energy transfer processes is obtained for high symmetry Eu(3+) sites and low doping levels. Emission intensity from (5)D(0) -> (7)F(1) transition increases as the temperature is raised from 10 to 240 K, under excitation at 266 nm laser line, because in this transition the multiphonon emission becomes significant only above 240 K. As an extension of this result, we predict high effectiveness for room temperature operation of Eu-based optical communication devices. X-ray diffraction data show that the impurity excess inhibits particle growth, which may influence the asymmetry ratio of luminescence spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)