554 resultados para Gabor Wavelets


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The geometric characterization of low-voltage dielectric electro-active polymer (EAP) structures, comprised of nanometer thickness but areas of square centimeters, for applications such as artificial sphincters requires methods with nanometer precision. Direct optical detection is usually restricted to sub-micrometer resolution because of the wavelength of the light applied. Therefore, we propose to take advantage of the cantilever bending system with optical readout revealing a sub-micrometer resolution at the deflection of the free end. It is demonstrated that this approach allows us to detect bending of rather conventional planar asymmetric, dielectric EAP-structures applying voltages well below 10 V. For this purpose, we built 100 μm-thin silicone films between 50 nm-thin silver layers on a 25 μm-thin polyetheretherketone (PEEK) substrate. The increase of the applied voltage in steps of 50 V until 1 kV resulted in a cantilever bending that exhibits only in restricted ranges the expected square dependence. The mean laser beam displacement on the detector corresponded to 6 nm per volt. The apparatus will therefore become a powerful mean to analyze and thereby improve low-voltage dielectric EAP-structures to realize nanometer-thin layers for stack actuators to be incorporated into artificial sphincter systems for treating severe urinary and fecal incontinence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have recorded reflection profiles of firn through large areas of West Antarctica and part of the East Antarctic plateau using 400 MHz short-pulse radar. The locations show accumulation rates that vary from well above to well below the vertical radar resolution. Most reflection horizons have extensive lateral continuity, and are composed of distinctive wavelets with a consistent phase polarity sequence within their successive half-cycles. We modeled these waveforms, and conclude that they arise from thin, double layers of ice over hoar, which is consistent with the standard model of firn stratification. In addition, we conclude that ice/hoar layers are extensive throughout West Antarctica and also present (although more sparsely) beneath the Antarctic Plateau.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wavelet analysis offers an alternative to Fourier based time-series analysis, and is particularly useful when the amplitudes and periods of dominant cycles are time dependent. We analyse climatic records derived from oxygen isotopic ratios of marine sediment cores with modified Morlet wavelets. We use a normalization of the Morlet wavelets which allows direct correspondence with Fourier analysis. This provides a direct view of the oscillations at various frequencies, and illustrates the nature of the time-dependence of the dominant cycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Every year, the EAPCI Board invites presidents and representatives of the interventional working groups affiliated to EAPCI to discuss issues and strategies surrounding the goals of education and advanced healthcare practices in interventional cardiology. In 2013, the 2nd EAPCI Summit, organised by the EAPCI Board in collaboration with the NIFYI committee, was entirely dedicated to discussing the unmet needs of the young generation of interventional cardiologists. In this article, we highlight a selection of the key points and proposed actions highlighted during the summit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To assess patients' outcomes after subacromial or glenohumeral injections based on the degree of lateral extension of the acromion. METHODS 307 patients were prospectively included after therapeutic fluoroscopy-guided subacromial (n = 148) or glenohumeral (n = 159) injections with anaesthetic and long-acting corticosteroids. Pre- and post-injection outcomes at 1 week and 1 month were obtained using the 11-point numerical rating scale (NRS) for pain. Lateral extension of the acromion was quantified and categorized by the critical shoulder angle (CSA) and the acromion index (AI) on anteroposterior conventional radiographs. RESULTS Patients' outcomes at 1 week and 1 month were significantly improved (p < 0.001) compared to baseline for subacromial and glenohumeral injection patients. Patients with a CSA <35° showed significantly higher pain reduction 1 month after subacromial injection compared to patients with a CSA >35° (4.2 ± 2.6 vs. 3.2 ± 3.0, p = 0.04). A significant difference in the 1-month NRS change in pain scores is noted for smaller AIs after subacromial injection (4.3 ± 2.8 vs. 2.6 ± 2.9; p = 0.01). No significant association was noted between clinical outcome and the lateral extension of the acromion after glenohumeral joint injections. CONCLUSIONS A short lateral extension of the acromion was associated with better clinical outcomes in subacromial injection patients but not in glenohumeral injection patients. KEY POINTS • Patients' outcomes at 1 month improved significantly compared to baseline for subacromial injections. • Patients' outcomes at 1 month improved significantly compared to baseline for glenohumeral injections. • Short acromial lateralization was associated with better clinical outcome after subacromial injection. • The acromial lateralization was not associated with clinical outcome after glenohumeral injection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This study reports a series of pitfalls, premature failures and explantations of the third-generation Freedom SOLO (FS) bovine pericardial stentless valve. METHODS A total of 149 patients underwent aortic valve replacement using the FS. Follow-up was 100% complete with an average observation time of 5.5 ± 2.3 years (maximum 8.7 years) and a total of 825 patient-years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. RESULTS Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92, 88, 80, 70 and 62%, respectively. Fourteen prostheses required explantation due to valve-independent dysfunction (n = 5; i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n = 4 and severe stenosis, n = 5). Thus, freedom from explantation at 5, 6, 7, 8 and 9 years was 95, 94, 91, 81 and 72%, respectively. An acute vertical tear along the non-coronary/right coronary commissure to the base occurred at a mean of 6.0 years (range 4.3-7.3 years) and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years (range 7.0-8.3 years) due to severe functional stenosis and gross calcification that included the entire aortic root. CONCLUSIONS The FS stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6-7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Loeys-Dietz syndrome (LDS) is characterized by acute aortic dissection (AAD) at aortic diameters below thresholds for intervention in patients with Marfan syndrome (MFS). The aim was to evaluate the outcome of LDS patients primarily treated as having MFS. METHODS We analysed 68 consecutive patients who underwent surgery between 1995 and 2007 under the assumption of having MFS before retrospectively being screened for LDS when genetic testing became available. These patients were followed up until 2013, and underwent a total of 115 aortic surgeries. RESULTS Genetic testing was performed in 76% of the patients. Sixty per cent of these patients were positive for FBN1 mutations associated with MFS, 20% had no FBN1 mutation and 17% harboured TGFBR1/2 mutations associated with LDS. Mean follow-up was 12.7 ± 7 years. All-cause 30-day, 6-month and 1-year mortality rates were 2.9, 4.4 and 7.3%, respectively. Interestingly, initial presentation with AAD did not differ between LDS and MFS (33 vs 37%, P = 0.48) nor did long-term mortality compared with MFS patients (11 vs 16%, P = 1.0) or within MFS subgroups (FBN1 positive 13%, P = 1.0; FBN1 negative 10%, P = 1.0; not tested 25%, P = 0.62). There was no difference in the need for secondary total arch replacement between LDS and MFS patients (11 vs 14%, P = 1.0), nor within MFS subgroups (FBN1 positive 16%, P = 1.0; FBN1 negative 10%, P = 1.0; not tested 13%, P = 1.0). Total aortic replacement became necessary in 22% of LDS compared with 12% of MFS patients (P = 0.6) and did not differ significantly between MFS subgroups. CONCLUSIONS Although early surgical intervention in LDS is warranted to avoid AAD, the current data suggest that once the diseased segment is repaired, there seems to be no additional burden in terms of mortality or reoperation rate compared with that in MFS patients, with or without confirmed FBN1 mutation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the intraoperative courses of 2 consecutive Berlin Heart Excor® Pediatric Ventricular Assist Device implantations, in which transcranial Doppler ultrasonography helped to detect macroscopically undetected residual air bubbles captured in the pump after air removal had been correctly performed according to manufacturer's specifications. Our experience with these cases suggests that a beat-to beat deairing maneuver guided by transcranial Doppler is a useful strategy for reducing cerebral exposure to perioperative gaseous microembolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Cyclic recruitment and derecruitment of atelectasis can occur during mechanical ventilation, especially in injured lungs. Experimentally, cyclic recruitment and derecruitment can be quantified by respiration-dependent changes in PaO2 (ΔPaO2), reflecting the varying intrapulmonary shunt fraction within the respiratory cycle. This study investigated the effect of inspiration to expiration ratio upon ΔPaO2 and Horowitz index. DESIGN Prospective randomized study. SETTING Laboratory investigation. SUBJECTS Piglets, average weight 30 ± 2 kg. INTERVENTIONS At respiratory rate 6 breaths/min, end-inspiratory pressure (Pendinsp) 40 cm H2O, positive end-expiratory pressure 5 cm H2O, and FIO2 1.0, measurements were performed at randomly set inspiration to expiration ratios during baseline healthy and mild surfactant depletion injury. Lung damage was titrated by repetitive surfactant washout to induce maximal cyclic recruitment and derecruitment as measured by multifrequency phase fluorimetry. Regional ventilation distribution was evaluated by electrical impedance tomography. Step changes in airway pressure from 5 to 40 cm H2O and vice versa were performed after lavage to calculate PO2-based recruitment and derecruitment time constants (TAU). MEASUREMENTS AND MAIN RESULTS In baseline healthy, cyclic recruitment and derecruitment could not be provoked, whereas in model acute respiratory distress syndrome, the highest ΔPaO2 were routinely detected at an inspiration to expiration ratio of 1:4 (range, 52-277 torr [6.9-36.9 kPa]). Shorter expiration time reduced cyclic recruitment and derecruitment significantly (158 ± 85 torr [21.1 ± 11.3 kPa] [inspiration to expiration ratio, 1:4]; 25 ± 12 torr [3.3 ± 1.6 kPa] [inspiration to expiration ratio, 4:1]; p < 0.0001), whereas the PaO2/FIO2 ratio increased (267 ± 50 [inspiration to expiration ratio, 1:4]; 424 ± 53 [inspiration to expiration ratio, 4:1]; p < 0.0001). Correspondingly, regional ventilation redistributed toward dependent lung regions (p < 0.0001). Recruitment was much faster (TAU: fast 1.6 s [78%]; slow 9.2 s) than derecruitment (TAU: fast 3.1 s [87%]; slow 17.7 s) (p = 0.0078). CONCLUSIONS Inverse ratio ventilation minimizes cyclic recruitment and derecruitment of atelectasis in an experimental model of surfactant-depleted pigs. Time constants for recruitment and derecruitment, and regional ventilation distribution, reflect these findings and highlight the time dependency of cyclic recruitment and derecruitment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary artery bypass grafting (CABG) by electroencephalogram P300 wave event-related potentials and number connection test (NCT) as metrics of cognitive function. METHODS Cognitive brain function was assessed in 31 patients in 2013 with a mean age of 65 years [standard deviation (SD) 10] undergoing CABG by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds) directly prior to intervention, 7 days after and 3 months later. Number connection test, serving as method of control, was performed simultaneously in all patients. RESULTS Seven days following CABG, cognitive P300 evoked potentials were comparable with preoperative baseline values [vertex (Cz) 376 (SD 11) ms vs 378 (18) ms, P = 0.39; frontal (Fz) 377 (11) vs 379 (21) ms, P = 0.53]. Cognitive brain function at 3 months was compared with baseline values [(Cz) 376 (11) ms vs 371 (14 ms) P = 0.09; (Fz) 377 (11) ms vs 371 (15) ms, P = 0.04]. Between the first postoperative measurement and 3 months later, significant improvement was observed [(Cz) 378 (18) ms vs 371 (14) ms, P = 0.03; (Fz) 379 (21) vs 371 (15) ms, P = 0.02]. Similar clearly corresponding patterns could be obtained via the number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (P = 0.05) and (Fz) results (P = 0.04). CONCLUSIONS MECC does not adversely affect cognitive brain function after CABG. Additionally, these patients experience a substantial significant cognitive improvement after 3 months, evidentiary proving that the concept of MECC ensures safety and outcome in terms of brain function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Antifibrinolytics have been used for 2 decades to reduce bleeding in cardiac surgery. MDCO-2010 is a novel, synthetic, serine protease inhibitor. We describe the first experience with this drug in patients. METHODS In this phase II, double-blind, placebo-controlled study, 32 patients undergoing isolated primary coronary artery bypass grafting with cardiopulmonary bypass were randomly assigned to 1 of 5 increasing dosage groups of MDCO-2010. The primary aim was to evaluate pharmacokinetics (PK) with assessment of plasmatic concentrations of the drug, short-term safety, and tolerance of MDCO-2010. Secondary end points were influence on coagulation, chest tube drainage, and transfusion requirements. RESULTS PK analysis showed linear dosage-proportional correlation between MDCO-2010 infusion rate and PK parameters. Blood loss was significantly reduced in the 3 highest dosage groups compared with control (P = 0.002, 0.004 and 0.011, respectively). The incidence of allogeneic blood product transfusions was lower with MDCO-2010 4/24 (17%) vs 4/8 (50%) in the control group. MDCO-2010 exhibited dosage-dependent antifibrinolytic effects through suppression of D-dimer generation and inhibition of tissue plasminogen activator-induced lysis in ROTEM analysis as well as anticoagulant effects demonstrated by prolongation of activated clotting time and activated partial thromboplastin time. No systematic differences in markers of end organ function were observed among treatment groups. Three patients in the MDCO-2010 groups experienced serious adverse events. One patient experienced intraoperative thrombosis of venous grafts considered possibly related to the study drug. No reexploration for mediastinal bleeding was required, and there were no deaths. CONCLUSIONS This first-in-patient study demonstrated dosage-proportional PK for MDCO-2010 and reduction of chest tube drainage and transfusions in patients undergoing primary coronary artery bypass grafting. Antifibrinolytic and anticoagulant effects were demonstrated using various markers of coagulation. MDCO-2010 was well tolerated and showed an acceptable initial safety profile. Larger multi-institutional studies are warranted to further investigate the safety and efficacy of this compound.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Etomidate is an intravenous hypnotic with a favourable clinical profile in haemodynamic high-risk scenarios. Currently, there is an active debate about the clinical significance of the drug's side effects and its overall risk-benefit ratio. Etomidate-induced transient adrenocortical suppression is well documented and has been associated with increased mortality in sepsis. In surgical patients at risk of hypotensive complications, however, a review of current literature provides no robust evidence to contraindicate a single-bolus etomidate induction. Large randomised controlled trials as well as additional observational data are required to compare safety of etomidate and its alternatives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glucose-6-phosphate dehydrogenase (G6PD) deficiency, a frequent congenital human enzyme defect, is the most frequent cause of hemolytic anemia triggered by drugs or infectious diseases. Drugs which induce acute hemolysis in patients with G6PD deficiency are often used in anesthesia and perioperative pain therapy. Considering the fact that patients from geographic regions with a high prevalence of the disease are often treated in European hospitals, special attention should be paid to this problem. We report a case of a 30-year-old female patient with favism and review the disease and anesthesia-related implications.