854 resultados para GLUCOSE MONITORING-SYSTEM
Resumo:
A wide range of non-destructive testing (NDT) methods for the monitoring the health of concrete structure has been studied for several years. The recent rapid evolution of wireless sensor network (WSN) technologies has resulted in the development of sensing elements that can be embedded in concrete, to monitor the health of infrastructure, collect and report valuable related data. The monitoring system can potentially decrease the high installation time and reduce maintenance cost associated with wired monitoring systems. The monitoring sensors need to operate for a long period of time, but sensors batteries have a finite life span. Hence, novel wireless powering methods must be devised. The optimization of wireless power transfer via Strongly Coupled Magnetic Resonance (SCMR) to sensors embedded in concrete is studied here. First, we analytically derive the optimal geometric parameters for transmission of power in the air. This specifically leads to the identification of the local and global optimization parameters and conditions, it was validated through electromagnetic simulations. Second, the optimum conditions were employed in the model for propagation of energy through plain and reinforced concrete at different humidity conditions, and frequencies with extended Debye's model. This analysis leads to the conclusion that SCMR can be used to efficiently power sensors in plain and reinforced concrete at different humidity levels and depth, also validated through electromagnetic simulations. The optimization of wireless power transmission via SMCR to Wearable and Implantable Medical Device (WIMD) are also explored. The optimum conditions from the analytics were used in the model for propagation of energy through different human tissues. This analysis shows that SCMR can be used to efficiently transfer power to sensors in human tissue without overheating through electromagnetic simulations, as excessive power might result in overheating of the tissue. Standard SCMR is sensitive to misalignment; both 2-loops and 3-loops SCMR with misalignment-insensitive performances are presented. The power transfer efficiencies above 50% was achieved over the complete misalignment range of 0°-90° and dramatically better than typical SCMR with efficiencies less than 10% in extreme misalignment topologies.
Resumo:
La course d’endurance active le système de récompense (SR) et est reliée aux comportements de recherche alimentaire. L’influence de la leptine sur l’activité physique (AP) volontaire est bien documentée d’un point de vue physiologique, mais très peu en termes d’impact hédonique. La leptine inhibe l’effet récompensant lié à la consommation de nourriture et joue un rôle semblable pour d’autres types de stimuli. La leptine s’arrime à la forme longue du récepteur à la leptine (Leprb) situé sur les neurones à dopamine (DA) et GABA de l’aire tegmentale ventrale (ATV) dans le mésencéphale. Signal transducer and Activator of Transcription 3 (STAT3) est un facteur de transcription important de la cascade de signalisation de la leptine. La phosphorylation de STAT3 n’est détectée que dans une parcelle des neurones DA positifs pour le Leprb, conférant aux neurones DA STAT3-spécifiques des caractéristiques uniques. Nous avons généré un modèle murin invalidé pour STAT3 sélectivement dans les neurones DA (STAT3DAT-KO). La première expérience consistait à évaluer les paramètres métaboliques de base de notre modèle en utilisant les chambres métaboliques Comprehensive Lab Animal Monitoring System (CLAMS), incluant l’activité ambulatoire, le ratio d’échanges respiratoires (RER) et la production de chaleur. Les STAT3DAT-KO sont hyperactives, démontré par une activité locomotrice augmentée, mais aucune variation entre les deux groupes n’est observée pour le RER et la production de chaleur, en plus d’un gain de poids identique. Une stratégie de récupération ciblant la réinsertion de STAT3 dans les neurones DA du système mésolimbique normalise l’AP anciennement plus élevée des STAT3DAT-KO à celle des contrôles, suivant l’accès libre à une roue d’exercice (RE) pour une durée de 4 semaines, suivant l’accès libre à une roue d’exercice (RE) pour une durée de 4 semaines. L’injection d’un psychostimulant (agoniste du récepteur DA de type 1 (D1R), le Chloro-APB-Hydrobromide (SKF 82958)) reflète une fonction dopaminergique réduite chez les STAT3DAT-KO. Un test de recherche compulsive de nourriture révèle une suppression de la prise alimentaire chez les deux groupes expérimentaux. Nous démontrons pour la première fois que la motivation alliée à la course d’endurance, indépendamment de la régulation de la prise alimentaire par la leptine, est dépendant d’une signalisation leptine-STAT3 amoindrie dans les neurones DA du système mésolimbique, révélant STAT3 comme élément clé dans la régulation du tonus dopaminergique et des propriétés récompensantes de l’AP.
Resumo:
Background: type 2 diabetes mellitus includes changes in lifestyle in its etiology of prevention, but the evidence is clear —even when people know what to do and what they want to do, they simply do not adopt adherence behaviors. Structured education will allow improving not only metabolic control, but also the adjustment process to a new situation of disease, as well as to develop the patient’s skills in order to make him the key manager of his illness. Objectives: To determine patients’ adherence to prescribed therapeutic regimens. Material and methods: Quantitative, cross-sectional, non-experimental, descriptive, correlational study, with a sample of 102 people with type 2 diabetes, aged between 40 and 85 years old, mostly male (51.96%). The evaluation protocol included social-demographic and clinical questionnaire, Diabetes Self-care Scale and a questionnaire on Diabetes’ knowledge. We also used HbA1c in order to directly assess adherence. Results: It appears that there is no statistically signiicant correlation between socio-demographic variables such as gender and age and adherence. Variables, such as blood glucose monitoring, speciic diet compliance and knowledge, reveal a statistically signiicant effect on adherence (P < .05). Conclusion: The evidence is clear on the urgent need to recognize the importance of measuring patient adherence to a diabetes treatment plan for the maintenance of glycaemic control. We suggest the reinforcement of educational programs in people with type 2 diabetes so as to improve adherence to self-care.
Resumo:
I-SMART is an Internet-based client management system that allows the State of Iowa and its licensed substance abuse treatment providers to administer, manage and provide cost efficient and quality substance abuse assessment and treatment services. Implementation of the I-SMART System is a key product in meeting the federal government requirements for National Outcome Monitoring System (NOMS).
Resumo:
Our aim was to determine the normative reference values of cardiorespiratory fitness (CRF) and to establish the proportion of subjects with low CRF suggestive of future cardio-metabolic risk.
Resumo:
Introducción: El monitoreo hemodinámico es una herramienta para diagnosticar el choque cardiogénico y monitorear la respuesta al tratamiento; puede ser invasivo, mínimamente invasivo o no invasivo. Se realiza rutinariamente con catéter de arteria pulmonar (CAP) o catéter de Swan Ganz; nuevas técnicas de monitoreo hemodinámico mínimamente invasivo tienen menor tasa de complicaciones. Actualmente se desconoce cuál técnica de monitoreo cuenta con mayor seguridad en el paciente con choque cardiogénico. Objetivo: Evaluar la seguridad del monitoreo hemodinámico invasivo comparado con el mínimamente invasivo en pacientes con choque cardiogénico en cuidado intensivo adultos. Diseño: Revisión sistemática de la literatura. Búsqueda en Pubmed, EMBASE, OVID - Cochrane Library, Lilacs, Scielo, registros de ensayos clínicos, actas de conferencias, repositorios, búsqueda de literatura gris en Google Scholar, Teseo y Open Grey hasta agosto de 2016, publicados en inglés y español. Resultados: Se identificó un único estudio con 331 pacientes críticamente enfermos que comparó el monitoreo hemodinámico con CAP versus PiCCO que concluyó que después de la corrección de los factores de confusión, la elección del tipo de monitoreo no influyó en los resultados clínicos más importantes en términos de complicaciones y mortalidad. Dado que se incluyeron otros diagnósticos, no es posible extrapolar los resultados sólo a choque cardiogénico. Conclusión: En la literatura disponible no hay evidencia de que el monitoreo hemodinámico invasivo comparado con el mínimamente invasivo, en pacientes adultos críticamente enfermos con choque cardiogénico, tenga diferencias en cuanto a complicaciones y mortalidad.
Resumo:
The use of continuous glucose monitor changes the way patients manage their diabetes, as observed in the increased number of daily insulin bolus, the increased number of daily BG measurements, and the differences in the distribution of BG measurements throughout the day. Continuous monitoring also increases the interaction of patients with the information system and modifies their patterns of use.
Resumo:
An Approach with Vertical Guidance (APV) is an instrument approach procedure which provides horizontal and vertical guidance to a pilot on approach to landing in reduced visibility conditions. APV approaches can greatly reduce the safety risk to general aviation by improving the pilot’s situational awareness. In particular the incidence of Controlled Flight Into Terrain (CFIT) which has occurred in a number of fatal air crashes in general aviation over the past decade in Australia, can be reduced. APV approaches can also improve general aviation operations. If implemented at Australian airports, APV approach procedures are expected to bring a cost saving of millions of dollars to the economy due to fewer missed approaches, diversions and an increased safety benefit. The provision of accurate horizontal and vertical guidance is achievable using the Global Positioning System (GPS). Because aviation is a safety of life application, an aviation-certified GPS receiver must have integrity monitoring or augmentation to ensure that its navigation solution can be trusted. However, the difficulty with the current GPS satellite constellation alone meeting APV integrity requirements, the susceptibility of GPS to jamming or interference and the potential shortcomings of proposed augmentation solutions for Australia such as the Ground-based Regional Augmentation System (GRAS) justifies the investigation of Aircraft Based Augmentation Systems (ABAS) as an alternative integrity solution for general aviation. ABAS augments GPS with other sensors at the aircraft to help it meet the integrity requirements. Typical ABAS designs assume high quality inertial sensors to provide an accurate reference trajectory for Kalman filters. Unfortunately high-quality inertial sensors are too expensive for general aviation. In contrast to these approaches the purpose of this research is to investigate fusing GPS with lower-cost Micro-Electro-Mechanical System (MEMS) Inertial Measurement Units (IMU) and a mathematical model of aircraft dynamics, referred to as an Aircraft Dynamic Model (ADM) in this thesis. Using a model of aircraft dynamics in navigation systems has been studied before in the available literature and shown to be useful particularly for aiding inertial coasting or attitude determination. In contrast to these applications, this thesis investigates its use in ABAS. This thesis presents an ABAS architecture concept which makes use of a MEMS IMU and ADM, named the General Aviation GPS Integrity System (GAGIS) for convenience. GAGIS includes a GPS, MEMS IMU, ADM, a bank of Extended Kalman Filters (EKF) and uses the Normalized Solution Separation (NSS) method for fault detection. The GPS, IMU and ADM information is fused together in a tightly-coupled configuration, with frequent GPS updates applied to correct the IMU and ADM. The use of both IMU and ADM allows for a number of different possible configurations. Three are investigated in this thesis; a GPS-IMU EKF, a GPS-ADM EKF and a GPS-IMU-ADM EKF. The integrity monitoring performance of the GPS-IMU EKF, GPS-ADM EKF and GPS-IMU-ADM EKF architectures are compared against each other and against a stand-alone GPS architecture in a series of computer simulation tests of an APV approach. Typical GPS, IMU, ADM and environmental errors are simulated. The simulation results show the GPS integrity monitoring performance achievable by augmenting GPS with an ADM and low-cost IMU for a general aviation aircraft on an APV approach. A contribution to research is made in determining whether a low-cost IMU or ADM can provide improved integrity monitoring performance over stand-alone GPS. It is found that a reduction of approximately 50% in protection levels is possible using the GPS-IMU EKF or GPS-ADM EKF as well as faster detection of a slowly growing ramp fault on a GPS pseudorange measurement. A second contribution is made in determining how augmenting GPS with an ADM compares to using a low-cost IMU. By comparing the results for the GPS-ADM EKF against the GPS-IMU EKF it is found that protection levels for the GPS-ADM EKF were only approximately 2% higher. This indicates that the GPS-ADM EKF may potentially replace the GPS-IMU EKF for integrity monitoring should the IMU ever fail. In this way the ADM may contribute to the navigation system robustness and redundancy. To investigate this further, a third contribution is made in determining whether or not the ADM can function as an IMU replacement to improve navigation system redundancy by investigating the case of three IMU accelerometers failing. It is found that the failed IMU measurements may be supplemented by the ADM and adequate integrity monitoring performance achieved. Besides treating the IMU and ADM separately as in the GPS-IMU EKF and GPS-ADM EKF, a fourth contribution is made in investigating the possibility of fusing the IMU and ADM information together to achieve greater performance than either alone. This is investigated using the GPS-IMU-ADM EKF. It is found that the GPS-IMU-ADM EKF can achieve protection levels approximately 3% lower in the horizontal and 6% lower in the vertical than a GPS-IMU EKF. However this small improvement may not justify the complexity of fusing the IMU with an ADM in practical systems. Affordable ABAS in general aviation may enhance existing GPS-only fault detection solutions or help overcome any outages in augmentation systems such as the Ground-based Regional Augmentation System (GRAS). Countries such as Australia which currently do not have an augmentation solution for general aviation could especially benefit from the economic savings and safety benefits of satellite navigation-based APV approaches.
Resumo:
This paper seeks to explore how organisations can effectively use performance management systems (PMS) to monitor collective identities. The monitoring of relationships between identity and an influential PMS—the balanced scorecard (BSC)—are explored. Drawing from identity and management accounting literature, this paper argues that identity products, patternings and processes are commonly positioned, monitored and interpreted through the multiple perspectives and levels of the BSC. Specifically, human, technical and organisational capital under the Learning and Growth perspective of the BSC can incorporate various identity measures that sustain the relative, distinctive and fluid nature of identities. The value of this research is to strengthen the theoretical grounds which position identity as an important dimension of organisational capital in PMS.
Resumo:
The world is facing problems due to the effects of increased atmospheric pollution, climate change and global warming. Innovative technologies to identify, quantify and assess fluxes exchange of the pollutant gases between the Earth’s surface and atmosphere are required. This paper proposes the development of a gas sensor system for a small UAV to monitor pollutant gases, collect data and geo-locate where the sample was taken. The prototype has two principal systems: a light portable gas sensor and an optional electric–solar powered UAV. The prototype will be suitable to: operate in the lower troposphere (100-500m); collect samples; stamp time and geo-locate each sample. One of the limitations of a small UAV is the limited power available therefore a small and low power consumption payload is designed and built for this research. The specific gases targeted in this research are NO2, mostly produce by traffic, and NH3 from farming, with concentrations above 0.05 ppm and 35 ppm respectively which are harmful to human health. The developed prototype will be a useful tool for scientists to analyse the behaviour and tendencies of pollutant gases producing more realistic models of them.
Resumo:
Background Despite its efficacy and cost-effectiveness, exercise-based cardiac rehabilitation is undertaken by less than one-third of clinically eligible cardiac patients in every country for which data is available. Reasons for non-participation include the unavailability of hospital-based rehabilitation programs, or excessive travel time and distance. For this reason, there have been calls for the development of more flexible alternatives. Methodology and Principal Findings We developed a system to enable walking-based cardiac rehabilitation in which the patient's single-lead ECG, heart rate, GPS-based speed and location are transmitted by a programmed smartphone to a secure server for real-time monitoring by a qualified exercise scientist. The feasibility of this approach was evaluated in 134 remotely-monitored exercise assessment and exercise sessions in cardiac patients unable to undertake hospital-based rehabilitation. Completion rates, rates of technical problems, detection of ECG changes, pre- and post-intervention six minute walk test (6 MWT), cardiac depression and Quality of Life (QOL) were key measures. The system was rated as easy and quick to use. It allowed participants to complete six weeks of exercise-based rehabilitation near their homes, worksites, or when travelling. The majority of sessions were completed without any technical problems, although periodic signal loss in areas of poor coverage was an occasional limitation. Several exercise and post-exercise ECG changes were detected. Participants showed improvements comparable to those reported for hospital-based programs, walking significantly further on the post-intervention 6 MWT, 637 m (95% CI: 565–726), than on the pre-test, 524 m (95% CI: 420–655), and reporting significantly reduced levels of cardiac depression and significantly improved physical health-related QOL. Conclusions and Significance The system provided a feasible and very flexible alternative form of supervised cardiac rehabilitation for those unable to access hospital-based programs, with the potential to address a well-recognised deficiency in health care provision in many countries. Future research should assess its longer-term efficacy, cost-effectiveness and safety in larger samples representing the spectrum of cardiac morbidity and severity.