995 resultados para Flow quantification
Resumo:
River Flow 2008, Vol.1
Resumo:
33rd IAHR Congress: Water Engineering for a Sustainable Environment
Resumo:
The localization of magma melting areas at the lithosphere bottom in extensional volcanic domains is poorly understood. Large polygenetic volcanoes of long duration and their associated magma chambers suggest that melting at depth may be focused at specific points within the mantle. To validate the hypothesis that the magma feeding a mafic crust, comes from permanent localized crustal reservoirs, it is necessary to map the fossilized magma flow within the crustal planar intrusions. Using the AMS, we obtain magmatic flow vectors from 34 alkaline basaltic dykes from São Jorge, São Miguel and Santa Maria islands in the Azores Archipelago, a hot-spot related triple junction. The dykes contain titanomagnetite showing a wide spectrum of solid solution ranging from Ti-rich to Ti-poor compositions with vestiges of maghemitization. Most of the dykes exhibit a normal magnetic fabric. The orientation of the magnetic lineation k1 axis is more variable than that of the k3 axis, which is generally well grouped. The dykes of São Jorge and São Miguel show a predominance of subhorizontal magmatic flows. In Santa Maria the deduced flow pattern is less systematic changing from subhorizontal in the southern part of the island to oblique in north. These results suggest that the ascent of magma beneath the islands of Azores is predominantly over localized melting sources and then collected within shallow magma chambers. According to this concept, dykes in the upper levels of the crust propagate laterally away from these magma chambers thus feeding the lava flows observed at the surface.
Resumo:
Dissertation presented to obtain the degree of Doctor of Philosophy in Electrical Engineering, speciality on Perceptional Systems, by the Universidade Nova de Lisboa, Faculty of Sciences and Technology
Resumo:
Among the determinant factors in the resistance and susceptibility of Biomphalaria to Schistosoma mansoni, hemocytes play an important role. Aiming at studying S. mansoni/Biomphalaria interactions related to hemocytes, the first step is certainly connected with the standardization of this cell population in uninfected Biomphalaria. In this way, quantification of this cell population in hemolymph, as well as its phagocitary capacity, have been determined for the first time. Furthermore, using susceptible and resistant strains of B. glabrata and B. tenagophila, the hemocytegram and phagocytary capacity of hemocytes after infection with S. mansoni were determined too. Resistant and susceptible strains of B.glabrata (BA and BH, respectively), as well as resistant and susceptible strains of B. tenagophila (Taim and CF, respectively) were infected with 10 miracidia of the LE and SJ strains of S. mansoni, respectively. These infected snails and respective uninfected controls were assessed in relation to the number of circulating hemocytes and alteration in the phagocytary capacity, by using Zymozan and MTT. Reading was taken by means of a spectrophotometer at 5 hours and 1,2,5,10,20 and 30 days after infection. The results showed a decrease in population of the circulating phagocytary cells, 5 hours after infection. One day post-infection, the circulating cells of the susceptible snails showed an increased metabolic activity, but the same event could not be observed in the resistant strains. In the subsequent observation periods, significant differences among the strains studied could not be observed until the end of the experiment
Resumo:
Dissertation for the Degree of Master in Technology and Food Safety – Food Quality
Resumo:
The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .
Resumo:
Accepted in 13th IEEE Symposium on Embedded Systems for Real-Time Multimedia (ESTIMedia 2015), Amsterdam, Netherlands.
Resumo:
Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.
Resumo:
The local fractional Burgers’ equation (LFBE) is investigated from the point of view of local fractional conservation laws envisaging a nonlinear local fractional transport equation with a linear non-differentiable diffusion term. The local fractional derivative transformations and the LFBE conversion to a linear local fractional diffusion equation are analyzed.
Resumo:
Canadian Journal of Civil Engineering 36(10) 1605–16
Resumo:
É de conhecimento do meio, que os Sistemas de Gestão Técnica Centralizada (SGTC) são uma mais-valia para a redução de utilização de energia associados principalmente aos sistemas de Aquecimento, Ventilação e Ar Condicionado (AVAC) apesar das potencialidades serem abrangentes a outras áreas. No entanto, existe alguma lacuna quanto à quantificação dessa mais-valia, facto importante sobretudo para a alteração de mentalidades dos promotores e proprietários dos edifícios, que por falta de prova, normalmente apenas associam o SGTC a um investimento num serviço desnecessário. As potencialidades dos SGTC são muitas, a título de exemplo, redução na utilização de fontes de energia, gestão da manutenção de sistemas e equipamentos, análise de eficiências de equipamentos, entre muitas outras, sendo nesta dissertação estudado com mais profundidade a questão associada à diferença dos custos de exploração resultantes da utilização de energia num edifício por parte dos sistemas de AVAC, isto é, quais serão os ganhos na utilização da energia, associados ao sistema AVAC, que podem ser obtidos com a implementação de um SGTC. Para o efeito, utilizou-se os sistemas e equipamentos existentes no edifício ECOTERMOLAB, pertencente ao Instituto de Soldadura e Qualidade (ISQ), com o objetivo de verificar as diferenças de utilização de energia resultantes do funcionamento do edifício em normal atividade, isto é, o edifício com todos os seus sistemas operacionais, incluindo o SGTC, e o edifício em funcionamento sem o auxílio do SGTC, ou seja, todos os sistemas associados ao sistema AVAC em funcionamento em modo manual e sem recurso a variação de caudal na rede aeráulica e hidráulica. Em termos anuais, o ECOTERMOLAB consome, aproximadamente, cerca de 38,1 MWh de energia elétrica e 39,2 MWh de gás natural, o que representa uma utilização de energia primária de 14,4 tep/ano. Esta energia, representa um encargo financeiro anual de, aproximadamente, 9500€/ano, correspondente a 7000€/ano de energia elétrica e 2500€/ano de gás natural. Após a análise desenvolvida neste trabalho, conclui-se que o funcionamento do edifício sem controlo do sistema de AVAC por SGTC representaria em termos anuais a um aumento de, aproximadamente, 25,2 MWh e 6,2 MWh de energia elétrica e de gás natural, respetivamente. Em termos de energia primária, a diferença entre soluções origina um acréscimo na utilização de energia de 7,8 tep/ano o que representa um aumento de emissão de CO2 na ordem das 9,4 ton/ano. A avaliação económica, recaiu sobre a determinação de indicadores para avaliação da viabilidade de implementação de um SGTC, nomeadamente, o período de retorno simples, o valor atual líquido e a taxa interna de rentabilidade. Todos estes indicadores se revelaram positivos, apresentando um período de retorno ligeiramente superior a oito anos, um valor atual líquido positivo (8864,1€) e uma taxa interna de rentabilidade superior à taxa de custo de capital (11,2%).
Resumo:
Abstract: Preferential flow and transport through macropores affect plant water use efficiency and enhance leaching of agrochemicals and the transport of colloids, thereby increasing the risk for contamination of groundwater resources. The effects of soil compaction, expressed in terms of bulk density (BD), and organic carbon (OC) content on preferential flow and transport were investigated using 150 undisturbed soil cores sampled from 15 × 15–m grids on two field sites. Both fields had loamy textures, but one site had significantly higher OC content. Leaching experiments were conducted in each core by applying a constant irrigation rate of 10 mm h−1 with a pulse application of tritium tracer. Five percent tritium mass arrival times and apparent dispersivities were derived from each of the tracer breakthrough curves and correlated with texture, OC content, and BD to assess the spatial distribution of preferential flow and transport across the investigated fields. Soils from both fields showed strong positive correlations between BD and preferential flow. Interestingly, the relationships between BD and tracer transport characteristics were markedly different for the two fields, although the relationship between BD and macroporosity was nearly identical. The difference was likely caused by the higher contents of fines and OC at one of the fields leading to stronger aggregation, smaller matrix permeability, and a more pronounced pipe-like pore system with well-aligned macropores.
Resumo:
This work aims to evaluate the feasibility of using image-based cytometry (IBC) in the analysis of algal cell quantification and viability, using Pseudokirchneriella subcapitata as a cell model. Cell concentration was determined by IBC to be in a linear range between 1 × 105 and 8 × 106 cells mL−1. Algal viability was defined on the basis that the intact membrane of viable cells excludes the SYTOX Green (SG) probe. The disruption of membrane integrity represents irreversible damage and consequently results in cell death. Using IBC, we were able to successfully discriminate between live (SG-negative cells) and dead algal cells (heat-treated at 65 °C for 60 min; SG-positive cells). The observed viability of algal populations containing different proportions of killed cells was well correlated (R 2 = 0.994) with the theoretical viability. The validation of the use of this technology was carried out by exposing algal cells of P. subcapitata to a copper stress test for 96 h. IBC allowed us to follow the evolution of cell concentration and the viability of copper-exposed algal populations. This technology overcomes several main drawbacks usually associated with microscopy counting, such as labour-intensive experiments, tedious work and lack of the representativeness of the cell counting. In conclusion, IBC allowed a fast and automated determination of the total number of algal cells and allowed us to analyse viability. This technology can provide a useful tool for a wide variety of fields that utilise microalgae, such as the aquatic toxicology and biotechnology fields.
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica