931 resultados para Finite Elements, Masonry, Reinforced Masonry, Constitutive Modelling
Resumo:
This research has focused on the study of the behavior and of the collapse of masonry arch bridges. The latest decades have seen an increasing interest in this structural type, that is still present and in use, despite the passage of time and the variation of the transport means. Several strategies have been developed during the time to simulate the response of this type of structures, although even today there is no generally accepted standard one for assessment of masonry arch bridges. The aim of this thesis is to compare the principal analytical and numerical methods existing in literature on case studies, trying to highlight values and weaknesses. The methods taken in exam are mainly three: i) the Thrust Line Analysis Method; ii) the Mechanism Method; iii) the Finite Element Methods. The Thrust Line Analysis Method and the Mechanism Method are analytical methods and derived from two of the fundamental theorems of the Plastic Analysis, while the Finite Element Method is a numerical method, that uses different strategies of discretization to analyze the structure. Every method is applied to the case study through computer-based representations, that allow a friendly-use application of the principles explained. A particular closed-form approach based on an elasto-plastic material model and developed by some Belgian researchers is also studied. To compare the three methods, two different case study have been analyzed: i) a generic masonry arch bridge with a single span; ii) a real masonry arch bridge, the Clemente Bridge, built on Savio River in Cesena. In the analyses performed, all the models are two-dimensional in order to have results comparable between the different methods taken in exam. The different methods have been compared with each other in terms of collapse load and of hinge positions.
Resumo:
This work illustrates a soil-tunnel-structure interaction study performed by an integrated,geotechnical and structural,approach based on 3D finite element analyses and validated against experimental observations.The study aims at analysing the response of reinforced concrete framed buildings on discrete foundations in interaction with metro lines.It refers to the case of the twin tunnels of the Milan (Italy) metro line 5,recently built in coarse grained materials using EPB machines,for which subsidence measurements collected along ground and building sections during tunnelling were available.Settlements measured under freefield conditions are firstly back interpreted using Gaussian empirical predictions. Then,the in situ measurements’ analysis is extended to include the evolving response of a 9 storey reinforced concrete building while being undercrossed by the metro line.In the finite element study,the soil mechanical behaviour is described using an advanced constitutive model. This latter,when combined with a proper simulation of the excavation process, proves to realistically reproduce the subsidence profiles under free field conditions and to capture the interaction phenomena occurring between the twin tunnels during the excavation. Furthermore, when the numerical model is extended to include the building, schematised in a detailed manner, the results are in good agreement with the monitoring data for different stages of the twin tunnelling. Thus, they indirectly confirm the satisfactory performance of the adopted numerical approach which also allows a direct evaluation of the structural response as an outcome of the analysis. Further analyses are also carried out modelling the building with different levels of detail. The results highlight that, in this case, the simplified approach based on the equivalent plate schematisation is inadequate to capture the real tunnelling induced displacement field. The overall behaviour of the system proves to be mainly influenced by the buried portion of the building which plays an essential role in the interaction mechanism, due to its high stiffness.
Resumo:
This study wants to analyze the effectiveness of different reinforcement typologies for masonry columns, in particular Fiber-Reinforced Polymer (FRP) and FRCM. The behavior of 10 solid – brick columns that are externally wrapped by FRP sheets and 2 unreinforced columns are presented in this study. The specimens are subjected to axial load until failure occurs. Three different confinement schemes were experimentally analyzed in order to evaluate and compare the effectiveness of the proposed strengthening techniques: 1) Grid carbon FRP (CFRP_G); 2) Grid glass FRP (GFRP_G); 3) Uniaxial carbon FRP (CFRP_U). Two different configurations of the reinforcing system were investigated: FRP sheets are applied as external reinforcement along the perimeter of the masonry columns in the form of continuous and discontinuous wrap, respectively. The results, compared with those for un-reinforced columns, indicate an increases in ultimate load, stiffness and ductility.
Resumo:
El refuerzo de estructuras existentes mediante el encolado exterior de láminas de polímeros reforzados con fibras (FRP) se ha convertido en la aplicación más común de los materiales compuestos avanzados en construcción. Estos materiales presentan muchas ventajas frente a los materiales convencionales (sin corrosión, ligeros, de fácil aplicación, etc.). Pero a pesar de las numerosas investigaciones realizadas, aún persisten ciertas dudas sobre algunos aspectos de su comportamiento y las aplicaciones prácticas se llevan a cabo sólo con la ayuda de guías, sin que haya una normativa oficial. El objetivo de este trabajo es incrementar el conocimiento sobre esta técnica de refuerzo, y más concretamente, sobre el refuerzo a flexión de estructuras de fábrica. Con frecuencia el elemento reforzado es de hormigón armado y las láminas de FRP encoladas al exterior sirven para mejorar su resistencia a flexión, cortante o compresión (encamisados). Sin embargo su empleo en otros materiales como las estructuras de fábrica resulta muy prometedor. Las fábricas se caracterizan por soportar muy bien los esfuerzos de compresión pero bastante mal los de tracción. Adherir láminas de materiales compuestos puede servir para mejorar la capacidad resistente de elementos de fábrica sometidos a esfuerzos de flexión. Pero para ello, debe quedar garantizada una correcta adherencia entre el FRP y la fábrica, especialmente en edificios antiguos cuya superficie puede estar deteriorada por encontrarse a la intemperie o por el propio paso del tiempo. En el capítulo II se describen los objetivos fundamentales del trabajo y el método seguido. En el capítulo III se hace una amplia revisión del estado de conocimiento sobre el tema. En el apartado III.1 se detallan las principales características y propiedades mecánicas de fibras, matrices y materiales compuestos así como sus principales aplicaciones, haciendo especial hincapié en aspectos relativos a su durabilidad. En el apartado III.2 se incluye una revisión histórica de las líneas de investigación, tanto teóricas como empíricas, publicadas sobre estructuras de hormigón reforzadas a flexión encolando materiales compuestos. El apartado III.3 se centra en el aspecto fundamental de la adherencia refuerzo-soporte. Se hace un repaso a distintos modelos propuestos para prevenir el despegue distinguiendo si éste se inicia en la zona de anclaje o si está inducido por fisuras en la zona interior del elemento. Se observa falta de consenso en las propuestas. Además en este punto se relatan las campañas experimentales publicadas acerca de la adherencia entre materiales compuestos y fábricas. En el apartado III.4 se analizan las particularidades de las estructuras de fábrica. Además, se revisan algunas de las investigaciones relativas a la mejora de su comportamiento a flexión mediante láminas de FRP. El comportamiento mecánico de muros reforzados solicitados a flexión pura (sin compresión) ha sido documentado por varios autores, si bien es una situación poco frecuente en fábricas reales. Ni el comportamiento mecánico de muros reforzados solicitados a flexocompresión ni la incidencia que el nivel de compresión soportado por la fábrica tiene sobre la capacidad resistente del elemento reforzado han sido suficientemente tratados. En cuanto a los trabajos teóricos, las diferentes propuestas se basan en los métodos utilizados para hormigón armado y comparten los principios habituales de cálculo. Sin embargo, presentan diferencias relativas, sobre todo, a tres aspectos: 1) la forma de modelar el comportamiento de la fábrica, 2) el valor de deformación de cálculo del refuerzo, y 3) el modo de fallo que se considera recomendable buscar con el diseño. A pesar de ello, el ajuste con la parte experimental de cada trabajo suele ser bueno debido a una enorme disparidad en las variables consideradas. Cada campaña presenta un modo de fallo característico y la formulación que se propone resulta apropiada para él. Parece necesario desarrollar un método de cálculo para fábricas flexocomprimidas reforzadas con FRP que pueda ser utilizado para todos los posibles fallos, tanto atribuibles a la lámina como a la fábrica. En el apartado III.4 se repasan algunas lesiones habituales en fábricas solicitadas a flexión y se recogen ejemplos de refuerzos con FRP para reparar o prevenir estos daños. Para mejorar el conocimiento sobre el tema, se llevan a cabo dos pequeñas campañas experimentales realizadas en el Instituto de Ciencias de la Construcción Eduardo Torroja. La primera acerca de la adherencia de materiales compuestos encolados a fábricas deterioradas (apartado IV.1) y la segunda sobre el comportamiento estructural a flexocompresión de probetas de fábrica reforzadas con estos materiales (apartado IV.2). En el capítulo V se analizan algunos de los modelos de adherencia propuestos para prevenir el despegue del extremo del refuerzo. Se confirma que las predicciones obtenidas con ellos resultan muy dispares. Se recopila una base de datos con los resultados experimentales de campañas sobre adherencia de FRP a fábricas extraídas de la literatura y de los resultados propios de la campaña descrita en el punto IV.1. Esta base de datos permite conocer cual de los métodos analizados resulta más adecuado para dimensionar el anclaje de láminas de FRP adheridas a fábricas. En el capítulo VI se propone un método para la comprobación en agotamiento de secciones de fábrica reforzadas con materiales compuestos sometidas a esfuerzos combinados de flexión y compresión. Está basado en el procedimiento de cálculo de la capacidad resistente de secciones de hormigón armado pero adaptado a las fábricas reforzadas. Para ello, se utiliza un diagrama de cálculo tensión deformación de la fábrica de tipo bilineal (acorde con el CTE DB SE-F) cuya simplicidad facilita el desarrollo de toda la formulación al tiempo que resulta adecuado para predecir la capacidad resistente a flexión tanto para fallos debidos al refuerzo como a la fábrica. Además se limita la deformación de cálculo del refuerzo teniendo en consideración ciertos aspectos que provocan que la lámina adherida no pueda desarrollar toda su resistencia, como el desprendimiento inducido por fisuras en el interior del elemento o el deterioro medioambiental. En concreto, se propone un “coeficiente reductor por adherencia” que se determina a partir de una base de datos con 68 resultados experimentales procedentes de publicaciones de varios autores y de los ensayos propios de la campaña descrita en el punto IV.2. También se revisa la formulación propuesta con ayuda de la base de datos. En el capítulo VII se estudia la incidencia de las principales variables, como el axil, la deformación de cálculo del refuerzo o su rigidez, en la capacidad final del elemento. Las conclusiones del trabajo realizado y las posibles líneas futuras de investigación se exponen en el capítulo VIII. ABSTRACT Strengthening of existing structures with externally bonded fiber reinforced polymers (FRP) has become the most common application of advanced composite materials in construction. These materials exhibit many advantages in comparison with traditional ones (corrosion resistance, light weight, easy to apply, etc.). But despite countless researches have been done, there are still doubts about some aspects of their behaviour and applications are carried out only with the help of guidelines, without official regulations. The aim of this work is to improve the knowledge on this retrofitting technique, particularly in regard to flexural strengthening of masonry structures. Reinforced concrete is often the strengthened material and external glued FRP plates are used to improve its flexural, shear or compressive (by wrapping) capacity. However the use of this technique on other materials like masonry structures looks promising. Unreinforced masonry is characterized for being a good material to support compressive stresses but really bad to withstand tensile ones. Glue composite plates can improve the flexural capacity of masonry elements subject to bending. But a proper bond between FRP sheet and masonry must be ensured to do that, especially in old buildings whose surface can be damaged due to being outside or ageing. The main objectives of the work and the methodology carried out are described In Chapter II. An extensive overview of the state of art is done in Chapter III. In Section III.1 physical and mechanical properties of fibers, matrix and composites and their main applications are related. Durability aspects are especially emphasized. Section III.2 includes an historical overview of theoretical and empirical researches on concrete structures strengthened gluing FRP plates to improve their flexural behaviour. Section III.3 focuses on the critical point of bonding between FRP and substrate. Some theoretical models to prevent debonding of FRP laminate are reviewed, it has made a distinction between models for detachment at the end of the plate or debonding in the intermediate zones due to the effects of cracks. It is observed a lack of agreement in the proposals. Some experimental studies on bonding between masonry and FRP are also related in this chapter. The particular characteristics of masonry structures are analyzed in Section III.4. Besides some empirical and theoretical investigations relative to improve their flexural capacity with FRP sheets are reviewed. The mechanical behaviour of strengthened walls subject to pure bending (without compression) has been established by several authors, but this is an unusual situation for real masonry. Neither mechanical behaviour of walls subject to bending and compression nor influence of axial load in the final capacity of the strengthened element are adequately studied. In regard to theoretical studies, the different proposals are based on reinforced concrete analytical methods and share common design principles. However, they present differences, especially, about three aspects: 1) the constitutive law of masonry, 2) the value of ultimate FRP strain and 3) the desirable failure mode that must be looked for. In spite of them, a good agreement between each experimental program and its theoretical study is often exhibited due to enormous disparity in considered test parameters. Each experimental program usually presents a characteristic failure mode and the proposed formulation results appropriate for this one. It seems necessary to develop a method for FRP strengthened walls subject to bending and compression enable for all failure modes (due to FRP or masonry). Some common damages in masonry subject to bending are explained in Section III.4. Examples of FRP strengthening to repair or prevent these damages are also written. Two small experimental programs are carried out in Eduardo Torroja Institute to improve the knowledge on this topic. The first one is concerned about the bond between FRP plates and damaged masonry (section IV.1) and the second one is related to the mechanical behaviour of the strengthened masonry specimens subject to out of plane bending combined with axial force (section IV.2). In the Chapter V some bond models to prevent the debonding at the FRP plate end are checked. It is confirmed that their predictions are so different. A pure-shear test database is compiled with results from the existing literature and others from the experimental program described in section IV.1. This database lets know which of the considered model is more suitable to design anchorage lengths of glued FRP to masonry. In the Chapter VI a method to check unreinforced masonry sections with external FRP strengthening subject to bending and compression to the ultimate limit state is proposed. This method is based on concrete reinforced one, but it is adapted to strengthened masonry. A bilinear constitutive law is used for masonry (according to CTE DB SE-F). Its simplicity helps to develop the model formulation and it has proven to be suitable to predict bending capacity either for FRP failures or masonry crushing. With regard to FRP, the design strain is limited. It is taken into account different aspects which cause the plate can’t reach its ultimate strength, like intermediate FRP debonding induced by opening cracking or environmental damage. A “bond factor” is proposed. It is obtained by means of an experimental bending test database that includes 68 results from the existing literature and from the experimental program described in section IV.2. The proposed formulation has also been checked with the help of bending database. The effects of the main parameters, like axial load, FRP design effective strain or FRP stiffness, on the bending capacity of the strengthened element are studied in Chapter VII. Finally, the main conclusions from the work carried out are summarized in Chapter VIII. Future lines of research to be explored are suggested as well.
Resumo:
Momentum, mass and energy balance laws provide the tools for the study of the evolution of an icefield covering a subglacial lake. The ice is described as a non-Newtonian fluid with a power-law constitutive relationship with temperature- and stress-dependent viscosity (Glen?s law) [1]. The phase transition mechanisms at the air/ice and ice/water interfaces yield moving boundary formulations, and lake hydrodynamics requires equation reduction for treating the turbulence.
Resumo:
Los ensayos virtuales de materiales compuestos han aparecido como un nuevo concepto dentro de la industria aeroespacial, y disponen de un vasto potencial para reducir los enormes costes de certificación y desarrollo asociados con las tediosas campañas experimentales, que incluyen un gran número de paneles, subcomponentes y componentes. El objetivo de los ensayos virtuales es sustituir algunos ensayos por simulaciones computacionales con alta fidelidad. Esta tesis es una contribución a la aproximación multiescala desarrollada en el Instituto IMDEA Materiales para predecir el comportamiento mecánico de un laminado de material compuesto dadas las propiedades de la lámina y la intercara. La mecánica de daño continuo (CDM) formula el daño intralaminar a nivel constitutivo de material. El modelo de daño intralaminar se combina con elementos cohesivos para representar daño interlaminar. Se desarrolló e implementó un modelo de daño continuo, y se aplicó a configuraciones simples de ensayos en laminados: impactos de baja y alta velocidad, ensayos de tracción, tests a cortadura. El análisis del método y la correlación con experimentos sugiere que los métodos son razonablemente adecuados para los test de impacto, pero insuficientes para el resto de ensayos. Para superar estas limitaciones de CDM, se ha mejorado la aproximación discreta de elementos finitos enriqueciendo la cinemática para incluir discontinuidades embebidas: el método extendido de los elementos finitos (X-FEM). Se adaptó X-FEM para un esquema explícito de integración temporal. El método es capaz de representar cualitativamente los mecanismos de fallo detallados en laminados. Sin embargo, los resultados muestran inconsistencias en la formulación que producen resultados cuantitativos erróneos. Por último, se ha revisado el método tradicional de X-FEM, y se ha desarrollado un nuevo método para superar sus limitaciones: el método cohesivo X-FEM estable. Las propiedades del nuevo método se estudiaron en detalle, y se concluyó que el método es robusto para implementación en códigos explícitos dinámicos escalables, resultando una nueva herramienta útil para la simulación de daño en composites. Virtual testing of composite materials has emerged as a new concept within the aerospace industry. It presents a very large potential to reduce the large certification costs and the long development times associated with the experimental campaigns, involving the testing of a large number of panels, sub-components and components. The aim of virtual testing is to replace some experimental tests by high-fidelity numerical simulations. This work is a contribution to the multiscale approach developed in Institute IMDEA Materials to predict the mechanical behavior of a composite laminate from the properties of the ply and the interply. Continuum Damage Mechanics (CDM) formulates intraply damage at the the material constitutive level. Intraply CDM is combined with cohesive elements to model interply damage. A CDM model was developed, implemented, and applied to simple mechanical tests of laminates: low and high velocity impact, tension of coupons, and shear deformation. The analysis of the results and the comparison with experiments indicated that the performance was reasonably good for the impact tests, but insuficient in the other cases. To overcome the limitations of CDM, the kinematics of the discrete finite element approximation was enhanced to include mesh embedded discontinuities, the eXtended Finite Element Method (X-FEM). The X-FEM was adapted to an explicit time integration scheme and was able to reproduce qualitatively the physical failure mechanisms in a composite laminate. However, the results revealed an inconsistency in the formulation that leads to erroneous quantitative results. Finally, the traditional X-FEM was reviewed, and a new method was developed to overcome its limitations, the stable cohesive X-FEM. The properties of the new method were studied in detail, and it was demonstrated that the new method was robust and can be implemented in a explicit finite element formulation, providing a new tool for damage simulation in composite materials.
Resumo:
A non-local gradient-based damage formulation within a geometrically non-linear set- ting is presented. The hyperelastic constitutive response at local material point level is governed by a strain energy function which is additively composed by an isotropic neo-Hookean matrix and by an anisotropic fibre-reinforced material based on the model proposed by T. Gasser, R. Ogden, and G. Holzapfel.
Resumo:
This paper shows the results of an experimental analysis on the bell tower of “Chiesa della Maddalena” (Mola di Bari, Italy), to better understand the structural behavior of slender masonry structures. The research aims to calibrate a numerical model by means of the Operational Modal Analysis (OMA) method. In this way realistic conclusions about the dynamic behavior of the structure are obtained. The choice of using an OMA derives from the necessity to know the modal parameters of a structure with a non-destructive testing, especially in case of cultural-historical value structures. Therefore by means of an easy and accurate process, it is possible to acquire in-situ environmental vibrations. The data collected are very important to estimate the mode shapes, the natural frequencies and the damping ratios of the structure. To analyze the data obtained from the monitoring, the Peak Picking method has been applied to the Fast Fourier Transforms (FFT) of the signals in order to identify the values of the effective natural frequencies and damping factors of the structure. The main frequencies and the damping ratios have been determined from measurements at some relevant locations. The responses have been then extrapolated and extended to the entire tower through a 3-D Finite Element Model. In this way, knowing the modes of vibration, it has been possible to understand the overall dynamic behavior of the structure.
Resumo:
The mechanical behaviour of transventilated façades performed by natural stone is necessarily based on the correct execution of both anchoring elements on the stone cladding as in the ones corresponding to the enclosure support, either with brick masonry walls or reinforced concrete walls. In the case studied in the present work, the origin of the damages suffered on the façade of a building located in Alcoy has been analyzed, where the detachment of part of the outer enclosure occurred. This enclosure is a transventilated façade formed by Bateig Blue stone tiles. To this end, “in situ” tests of the anchoring systems employed have been performed, as well as laboratory tests of mechanical characterization of the material and of different types of anchor, comparing these results with those obtained in both the simplified analytical models of continuum mechanics as developed by the Finite Element Method (FEM).
Resumo:
This paper presents a structural analysis of a masonry chimney built in the 1940s, which is currently being cataloged as local interest heritage. This structure has not served any industrial purpose for the last thirty years. The chimney is located in the town of Agost (Alicante - Spain) and directly exposed to the prevailing winds from the sea, as it is approximately 12 km away from the waterfront and there are not any significant barriers, which could protect the structure against the wind. There are longitudinal cracks and fissures all along the shaft because of the chimney’s geometrical characteristics, the effect of the masonry creep and especially the lack of maintenance. Moreover, there is also a permanent bending deformation in the upper 1/3 of the height due to the wind pressure. A numerical analysis for the static behavior against gravity and wind loads was performed using the structure’s current conditions after a detailed report of its geometry, its construction system and the cracking pattern. Afterwards, the dynamic behavior was studied, i.e. a seismic analysis using both response spectra and accelerograms in order to examine the structural stability. This work shows the pre-monitoring analysis before any experimental testing. Using the current results the future test conditions will be determined (e.g. number of sensors and monitoring point location, excitation systems, etc) prior to a possible structural reinforcement by applying composite material (fiber reinforced polymers).
Resumo:
The paper presents the analysis of an important historical building: the Saint James Theater in the city of Corfù (Greece) actually used as the Municipality House. The building, located in the center of the city, is made of carves stones and is characterized by a stocky shape and by the presence of wooden floors. The study deals with the structural identification of such structure through the analysis of its ambient vibrations recorded by means of accelerometers with high accuracy. A full dynamic testing was developed using ambient vibrations to identify the main modal parameters and to make a non-destructive characterization of this building. The results of these dynamic tests are compared with the modal analysis of a complex finite element (FE) simulation of the structure. This analysis may present several problems and uncertainties for this stocky building. Due to the presence of wooden floors, the local modes can be highly excited and, as a consequence, the evaluation of the structural modal parameters presents some difficulties.
Resumo:
The research is concerned with the application of the computer simulation technique to study the performance of reinforced concrete columns in a fire environment. The effect of three different concrete constitutive models incorporated in the computer simulation on the structural response of reinforced concrete columns exposed to fire is investigated. The material models differed mainly in respect to the formulation of the mechanical properties of concrete. The results from the simulation have clearly illustrated that a more realistic response of a reinforced concrete column exposed to fire is given by a constitutive model with transient creep or appropriate strain effect The assessment of the relative effect of the three concrete material models is considered from the analysis by adopting the approach of a parametric study, carried out using the results from a series of analyses on columns heated on three sides which produce substantial thermal gradients. Three different loading conditions were used on the column; axial loading and eccentric loading both to induce moments in the same sense and opposite sense to those induced by the thermal gradient. An axially loaded column heated on four sides was also considered. The computer modelling technique adopted separated the thermal and structural responses into two distinct computer programs. A finite element heat transfer analysis was used to determine the thermal response of the reinforced concrete columns when exposed to the ISO 834 furnace environment. The temperature distribution histories obtained were then used in conjunction with a structural response program. The effect of the occurrence of spalling on the structural behaviour of reinforced concrete column is also investigated. There is general recognition of the potential problems of spalling but no real investigation into what effect spalling has on the fire resistance of reinforced concrete members. In an attempt to address the situation, a method has been developed to model concrete columns exposed to fire which incorporates the effect of spalling. A total of 224 computer simulations were undertaken by varying the amounts of concrete lost during a specified period of exposure to fire. An array of six percentages of spalling were chosen for one range of simulation while a two stage progressive spalling regime was used for a second range. The quantification of the reduction in fire resistance of the columns against the amount of spalling, heating and loading patterns, and the time at which the concrete spalls appears to indicate that it is the amount of spalling which is the most significant variable in the reduction of fire resistance.
Resumo:
The present numerical investigation offers evidence concerning the validity and objectivity of the predictions of a simple, yet practical, finite element model concerning the responses of steel fibre reinforced concrete structural elements under static monotonic and cyclic loading. Emphasis is focused on realistically describing the fully brittle tensile behaviour of plain concrete and the contribution of steel fibres on the post-cracking behaviour it exhibits. The good correlation exhibited between the numerical predictions and their experimental counterparts reveals that, despite its simplicity, the subject model is capable of providing realistic predictions concerning the response of steel fibre reinforced concrete structural configurations exhibiting both ductile and brittle modes of failure without requiring recalibration.
Resumo:
A new semi-implicit stress integration algorithm for finite strain plasticity (compatible with hyperelas- ticity) is introduced. Its most distinctive feature is the use of different parameterizations of equilibrium and reference configurations. Rotation terms (nonlinear trigonometric functions) are integrated explicitly and correspond to a change in the reference configuration. In contrast, relative Green–Lagrange strains (which are quadratic in terms of displacements) represent the equilibrium configuration implicitly. In addition, the adequacy of several objective stress rates in the semi-implicit context is studied. We para- metrize both reference and equilibrium configurations, in contrast with the so-called objective stress integration algorithms which use coinciding configurations. A single constitutive framework provides quantities needed by common discretization schemes. This is computationally convenient and robust, as all elements only need to provide pre-established quantities irrespectively of the constitutive model. In this work, mixed strain/stress control is used, as well as our smoothing algorithm for the complemen- tarity condition. Exceptional time-step robustness is achieved in elasto-plastic problems: often fewer than one-tenth of the typical number of time increments can be used with a quantifiable effect in accuracy. The proposed algorithm is general: all hyperelastic models and all classical elasto-plastic models can be employed. Plane-stress, Shell and 3D examples are used to illustrate the new algorithm. Both isotropic and anisotropic behavior is presented in elasto-plastic and hyperelastic examples.
Resumo:
Two novelties are introduced: (i) a finite-strain semi-implicit integration algorithm compatible with current element technologies and (ii) the application to assumed-strain hexahedra. The Löwdin algo- rithm is adopted to obtain evolving frames applicable to finite strain anisotropy and a weighted least- squares algorithm is used to determine the mixed strain. Löwdin frames are very convenient to model anisotropic materials. Weighted least-squares circumvent the use of internal degrees-of-freedom. Het- erogeneity of element technologies introduce apparently incompatible constitutive requirements. Assumed-strain and enhanced strain elements can be either formulated in terms of the deformation gradient or the Green–Lagrange strain, many of the high-performance shell formulations are corotational and constitutive constraints (such as incompressibility, plane stress and zero normal stress in shells) also depend on specific element formulations. We propose a unified integration algorithm compatible with possibly all element technologies. To assess its validity, a least-squares based hexahedral element is implemented and tested in depth. Basic linear problems as well as 5 finite-strain examples are inspected for correctness and competitive accuracy.