573 resultados para Fiberglass pipes


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dispersion of solid particles in the turbulent recirculation zones of sudden expansion pipes can be characterized by different Stokes numbers and mean drift parameter and its study is important because this kind of flows appears in many technological applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Direct Steam Generation (DSG) in Linear Fresnel (LF) solar collectors is being consolidated as a feasible technology for Concentrating Solar Power (CSP) plants. The competitiveness of this technology relies on the following main features: water as heat transfer fluid (HTF) in Solar Field (SF), obtaining high superheated steam temperatures and pressures at turbine inlet (500ºC and 90 bar), no heat tracing required to avoid HTF freezing, no HTF degradation, no environmental impacts, any heat exchanger between SF and Balance Of Plant (BOP), and low cost installation and maintenance. Regarding to LF solar collectors, were recently developed as an alternative to Parabolic Trough Collector (PTC) technology. The main advantages of LF are: the reduced collector manufacturing cost and maintenance, linear mirrors shapes versus parabolic mirror, fixed receiver pipes (no ball joints reducing leaking for high pressures), lower susceptibility to wind damages, and light supporting structures allowing reduced driving devices. Companies as Novatec, Areva, Solar Euromed, etc., are investing in LF DSG technology and constructing different pilot plants to demonstrate the benefits and feasibility of this solution for defined locations and conditions (Puerto Errado 1 and 2 in Murcia Spain, Lidellin Newcastle Australia, Kogran Creek in South West Queensland Australia, Kimberlina in Bakersfield California USA, Llo Solar in Pyrénées France,Dhursar in India,etc). There are several critical decisions that must be taken in order to obtain a compromise and optimization between plant performance, cost, and durability. Some of these decisions go through the SF design: proper thermodynamic operational parameters, receiver material selection for high pressures, phase separators and recirculation pumps number and location, pipes distribution to reduce the amount of tubes (reducing possible leaks points and transient time, etc.), etc. Attending to these aspects, the correct design parameters selection and its correct assessment are the main target for designing DSG LF power plants. For this purpose in the recent few years some commercial software tools were developed to simulatesolar thermal power plants, the most focused on LF DSG design are Thermoflex and System Advisor Model (SAM). Once the simulation tool is selected,it is made the study of the proposed SFconfiguration that constitutes the main innovation of this work, and also a comparison with one of the most typical state-of-the-art configuration. The transient analysis must be simulated with high detail level, mainly in the BOP during start up, shut down, stand by, and partial loads are crucial, to obtain the annual plant performance. An innovative SF configurationwas proposed and analyzed to improve plant performance. Finally it was demonstrated thermal inertia and BOP regulation mode are critical points in low sun irradiation day plant behavior, impacting in annual performance depending on power plant location.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acourse focused on the acquisition of integration competencies in ship production engineering, organized in collaboration with selected industry partners, is presented in this paper. The first part of the course is dedicated to Project Management: the students acquire skills in defining, using MS-PROJECT, the work breakdown structure (WBS), and the organization breakdown structure (OBS) in Engineering projects, through a series of examples of increasing complexity with the final one being the construction planning of a vessel. The second part of the course is dedicated to the use of a database manager, MS-ACCESS, in managing production related information.Aseries of increasing complexity examples is treated, the final one being the management of the piping database of a real vessel. This database consists of several thousand pipes, for which a production timing frame is defined connecting this part of the course with the first one. Finally, the third part of the course is devoted to working withFORAN,an Engineering Production application developed bySENERand widely used in the shipbuilding industry. With this application, the structural elements where all the outfittings will be located are defined through cooperative work by the students, working simultaneously in the same 3D model. In this paper, specific details about the learning process are given. Surveys have been posed to the students in order to get feedback from their experience as well as to assess their satisfaction with the learning process, compared to more traditional ones. Results from these surveys are discussed in the paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La presente Tesis Doctoral tiene como objetivo el estudio de flujo turbulento cargado con partículas sólidas a través de canales y tuberías de sección constante usando un enfoque Euleriano-Lagrangiano. El campo de flujo de la fase de transporte (aire) se resuelve usando simulación de grandes escalas (LES), implementada en un programa de volúmenes finitos mientras que las ecuaciones gobernantes de la fase dispersa son resueltas por medio de un algoritmo de seguimiento Lagrangiano de partículas que ha sido desarrollado y acoplado al programa que resuelve el flujo. Se estudia de manera sistemática y progresiva la interacción fluido→partícula (one-way coupling), a través de diferentes configuraciones geométricas en coordenadas cartesianas (canales de sección constante y variable) y en coordenadas cilíndricas (tuberías de sección constante y sección variable) abarcando diferentes números de Reynolds y diferentes tamaños de partículas; todos los resultados obtenidos han sido comparados con datos publicados previamente. El estudio de flujo multifásico a través de, tuberías de sección variable, ha sido abordada en otras investigaciones mayoritariamente de forma experimental o mediante simulación usando modelos de turbulencia menos complejos y no mediante LES. El patrón de flujo que se verifica en una tubería con expansión es muy complejo y dicha configuración geométrica se halla en múltiples aplicaciones industriales que involucran el transporte de partículas sólidas, por ello es de gran interés su estudio. Como hecho innovador, en esta tesis no solo se resuelven las estadísticas de velocidad del fluido y las partículas en tuberías con diferentes tamaños de expansión y diferentes regímenes de flujo sino que se caracteriza, usando diversas formulaciones del número de Stokes y el parámetro de arrastre, el ingreso y acumulación de partículas dentro de la zona de recirculación, obteniéndose resultados coincidentes con datos experimentales. ABSTRACT The objective of this Thesis research is to study the turbulent flow laden with solid particles through channels and pipes with using Eulerian-Lagrangian approach. The flow field of the transport phase (air ) is solved using large eddy simulation ( LES ) implemented in a program of finite volume while the governing equations of the dispersed phase are resolved by means of a particle Lagrangian tracking algorithm which was developed and coupled to principal program flow solver . We studied systematically and progressively the fluid interaction → particle ( one- way coupling ) , through different geometric configurations in Cartesian coordinates ( channel with constant and variable section) and in cylindrical coordinates ( pipes with constant section and variable section ) covering different Reynolds numbers and different particle sizes, all results have been compared with previously published data . The study of multiphase flow through, pipes with variable section has been addressed in other investigations predominantly experimentally or by simulation using less complex models and no turbulence by LES. The flow pattern is verified in a pipe expansion is very complex and this geometry is found in many industrial applications involving the transport of solid particles, so it is of great interest to study. As an innovator fact , in this Thesis not only finds fluid velocity statistics and particles with different sizes of pipe expansion and different flow regimes but characterized, using various formulations of the Stokes number and the drag parameter are resolved, the entry and accumulation of particles within the recirculation zone , matching results obtained with experimental data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Un caloducto en bucle cerrado o Loop Heat Pipe (LHP) es un dispositivo de transferencia de calor cuyo principio de operación se basa en la evaporación/condensación de un fluido de trabajo, que es bombeado a través de un circuito cerrado gracias a fuerzas de capilaridad. Gracias a su flexibilidad, su baja masa y su mínimo (incluso nulo) consumo de potencia, su principal aplicación ha sido identificada como parte del subsistema de control térmico de vehículos espaciales. En el presente trabajo se ha desarrollado un LHP capaz de funcionar eficientemente a temperaturas de hasta 125 oC, siguiendo la actual tendencia de los equipos a bordo de satélites de incrementar su temperatura de operación. En la selección del diseño optimo para dicho LHP, la compatibilidad entre materiales y fluido de trabajo se identificó como uno de los puntos clave. Para seleccionar la mejor combinación, se llevó a cabo una exhaustiva revisión del estado del arte, además de un estudio especifico que incluía el desarrollo de un banco de ensayos de compatibilidad. Como conclusión, la combinación seleccionada como la candidata idónea para ser integrada en el LHP capaz de operar hasta 125 oC fue un evaporador de acero inoxidable, líneas de titanio y amoniaco como fluido de trabajo. En esa línea se diseñó y fabricó un prototipo para ensayos y se desarrolló un modelo de simulación con EcosimPro para evaluar sus prestaciones. Se concluyó que el diseño era adecuado para el rango de operación definido. La incompatibilidad entre el fluido de trabajo y los materiales del LHP está ligada a la generación de gases no condensables. Para un estudio más detallado de los efectos de dichos gases en el funcionamiento del LHP se analizó su comportamiento con diferentes cantidades de nitrógeno inyectadas en su cámara de compensación, simulando un gas no condensable formado en el interior del dispositivo. El estudio se basó en el análisis de las temperaturas medidas experimentalmente a distintos niveles de potencia y temperatura de sumidero o fuente fría. Adicionalmente, dichos resultados se compararon con las predicciones obtenidas por medio del modelo en EcosimPro. Las principales conclusiones obtenidas fueron dos. La primera indica que una cantidad de gas no condensable más de dos veces mayor que la cantidad generada al final de la vida de un satélite típico de telecomunicaciones (15 años) tiene efectos casi despreciables en el funcionamiento del LHP. La segunda es que el principal efecto del gas no condensable es una disminución de la conductancia térmica, especialmente a bajas potencias y temperaturas de sumidero. El efecto es más significativo cuanto mayor es la cantidad de gas añadida. Asimismo, durante la campaña de ensayos se observó un fenómeno no esperado para grandes cantidades de gas no condensable. Dicho fenómeno consiste en un comportamiento oscilatorio, detectado tanto en los ensayos como en la simulación. Este efecto es susceptible de una investigación más profunda y los resultados obtenidos pueden constituir la base para dicha tarea. ABSTRACT Loop Heat Pipes (LHPs) are heat transfer devices whose operating principle is based on the evaporation/condensation of a working fluid, and which use capillary pumping forces to ensure the fluid circulation. Thanks to their flexibility, low mass and minimum (even null) power consumption, their main application has been identified as part of the thermal control subsystem in spacecraft. In the present work, an LHP able to operate efficiently up to 125 oC has been developed, which is in line with the current tendency of satellite on-board equipment to increase their operating temperatures. In selecting the optimal LHP design for the elevated temperature application, the compatibility between the materials and working fluid has been identified as one of the main drivers. An extensive literature review and a dedicated trade-off were performed, in order to select the optimal combination of fluids and materials for the LHP. The trade-off included the development of a dedicated compatibility test stand. In conclusion, the combination of stainless steel evaporator, titanium piping and ammonia as working fluid was selected as the best candidate to operate up to 125 oC. An LHP prototype was designed and manufactured and a simulation model in EcosimPro was developed to evaluate its performance. The first conclusion was that the defined LHP was suitable for the defined operational range. Incompatibility between the working fluid and LHP materials is linked to Non Condensable Gas (NCG) generation. Therefore, the behaviour of the LHP developed with different amounts of nitrogen injected in its compensation chamber to simulate NCG generation, was analyzed. The LHP performance was studied by analysis of the test results at different temperatures and power levels. The test results were also compared to simulations in EcosimPro. Two additional conclusions can be drawn: (i) the effects of an amount of more than two times the expected NCG at the end of life of a typical telecommunications satellite (15 years) is almost negligible on the LHP operation, and (ii) the main effect of the NCG is a decrease in the LHP thermal conductance, especially at low temperatures and low power levels. This decrease is more significant with the progressive addition of NCG. An unexpected phenomenon was observed in the LHP operation with large NCG amounts. Namely, an oscillatory behaviour, which was observed both in the tests and the simulation. This effect provides the basis for further studies concerning oscillations in LHPs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of mineral wool is becoming more widespread due to increased acoustic and thermal demands of Spanish Technical Building Code. This increase affects both in rehabilitation and new construction projects. Therefore, waste generation of this type of insulating material is having more importance. The main objective of this research is to study the possibility of recycling fiber obtained from mineral wool of the C&DW as an alternative material to chopped glass fibers that are currently used as reinforcing elements in the prefabricated plaster. To achieve this objective, series are made of plaster E-35 additived with rock wool residue and glass wool residue at different rates of addition. These series are repeated by changing the additive by E fiberglass (length of 25mm) to make a comparative analysis with respect to the series additived with mineral wool waste. All the series are subjected to the test to determine Shore C surface hardness and mechanical testing to determine the compressive and flexural strength. From the results it can be concluded that: with rock wool residue, increases Shore C hardness up to 15% with respect to the glass fiber and 9% with respect to the glass wool, with a percentage of addition 2%. With rock wool residue, weight is decreased by 5% with respect to the glass fiber and 4% with respect to the glass wool waste, with an addition percentage of 4%. For an addition rate of 4%, results in the flexural strength test with fiberglass are 85% higher than those obtained with glass wool residue. However, for a percentage of 1% addition, the results obtained with glass wool residue are 35% higher than those obtained with fiberglass. For an addition rate of 3% results in the compressive strength test with fiberglass are 54% lower than those obtained with rock wool waste and 70% lower than those obtained with glass wool waste. Comparing the two mineral wools, it can be concluded that up to 3% of the addition, the glass wool series results obtained are 10% higher than those additived with rock wool. However, higher percentages of addition show that the results obtained with rock wool are 35% higher than those obtained with glass wool. The general conclusion is that the series additived with mineral wool from C&DW show better results in tests than the ones used nowadays as plaster reinforcement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Air Mines The sky over the city's port was the color of a faulty screen, only partly lit up. As the silhouette of nearby buildings became darker, but more clearly visible against the fading blur-filter of a background, the realization came about how persistent a change had been taking place. Slowly, old wooden water reservoirs and rattling HVAC systems stopped being the only inhabitants of roofs. Slightly trembling, milkish jellyfish-translucent air volumes had joined the show in multiples. A few years ago artists and architects seized upon the death of buildings as their life-saving media. Equipped with constructive atlases and instruments they started disemboweling their subjects, poking about their systems, dumping out on the street the battered ugliness of their embarrassing bits and pieces, so rightly hidden by facades and height from everyday view. But, would you believe it? Even ?old ladies?, investment bankers or small children failed to get upset. Of course, old ladies are not what they used to be. It was old ladies themselves that made it happen after years of fights with the town hall, imaginative proposals and factual arguments. An industry with little financial gains but lots of welcome externalities was not, in fact, the ground for investment bankers. But they too had to admit that having otherwise stately buildings make fine particulate pencils with their facades was not the worse that could happen. Yes, making soot pencils had been found an interesting and visible end product of the endeavor, a sort of mining the air for vintage writing tools one can actually touch. The new view from the street did not seem as solid or dignified as that of old, and they hated that the market for Fine Particulates Extraction (FPE, read efpee) had to be applied on a matrix of blocks and streets that prevented undue concentration of the best or worse solutions. It had to be an evenly distributed city policy in order for the city to apply for cleaning casino money. Once the first prototypes had been deployed in buildings siding Garden Avenue or Bulwark Street even fast movers appreciated the sidekick of flower and plant smell dripping down the Urban Space Stations (USS, read use; USSs, read uses) as air and walls cooled off for a few hours after sunset. Enough. It was all nice to remember, but it was now time to go up and start the lightweight afternoon maintenance of their USS. Coop discussions had taken place all through the planning and continued through the construction phase as to how maintenance was going to be organized. Fasters had voted for a pro, pay a small amount and let them use it for rent and produce. In the end some neighbors decided they were slow enough to take care and it was now the turn. Regret came periodically, sometimes a week before, and lasted until work actually started. But lately it had been replaced by anxiety when it needed to be passed over to the next caretaker. It did not look their shift was good enough and couldn?t wait to fix it. Today small preparations needed to be made for a class visit next day from a nearby cook school. They were frequenters. It had not been easy, but it shouldn?t have been that hard. In the end, even the easiest things are hard if they involve a city, buildings and neighbors. On the face of the data, the technicalities and the way final designs had been worked out for adaptation to the different settings, the decision of where to go was self evident, but organization issues and the ever-growing politics of taste in a city of already-gentrified-rodents almost put the project in the frozen orbit of timeless beautiful future possibilities. This is how it was. A series of designs by XClinic and OSS had made it possible to adapt to different building structures, leave in most cases the roof untouched and adapted a new technology of flexing fiberglass tubes that dissipated wind pressure in smooth bending.......

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de este trabajo es conocer las posibles modificaciones que puede producir en el comportamiento de las estructuras de hormigón armado (EHA) el hecho de que sean utilizadas como estructuras termoactivas, ya sea como intercambiadores en contacto con el terreno, o como sistema de distribución de calor utilizando la inercia térmica de los elementos de hormigón del edificio, basándose en el uso de energías renovables. Las EHA termoactivas se caracterizan por la incorporación en su interior de tubos de polietileno por los que circulan fluidos a temperaturas medias, que pueden incidir en el comportamiento mecánico de los elementos estructurales debido a dos efectos fundamentales: el incremento de temperatura que se produce en el interior de la EHA y la perturbación provocada por la incorporación de los tubos de polietileno. Con este fin, se ha realizado una campaña experimental de probetas de hormigón, estudiando los dos efectos por separado, por un lado se ha evaluado el comportamiento de probetas de hormigón tipo H-25 y tipo H-30 sometidas a cuatro temperaturas diferentes: 20ºC, 40ºC, 70ºC y 100ºC, ensayando la resistencia a compresión y la resistencia a anclaje/adherencia mediante ensayo “pull-out”; y, por otro lado, se ha evaluado el comportamiento de probetas de hormigón tipo H-25 y tipo H-30, elaboradas con dos tipos de molde (cilíndrico y cúbico), en las que se ha colocado tubos de polietileno en su interior en distintas posiciones, ensayando su resistencia a compresión. Los resultados de los ensayos han puesto de manifiesto que aunque se produce una disminución en la resistencia a compresión, y a arrancamiento, del hormigón, al ser sometido a aumentos de temperatura, esta disminución de la propiedades mecánicas es inferior al 20% al no superar esta tecnología los 70ºC; y respecto a la variación de la resistencia a compresión de probetas cilíndricas y cúbicas, debidas a la incorporación de los tubos de polietileno, se observa que si la posición de los mismos es paralela a la dirección de la carga tampoco se ven comprometidas las propiedad mecánicas del hormigón en valores superiores al 20%. ABSTRACT The aim of this project is to study the effects of using concrete structures as thermo-active constructions, either as energy foundations or other kind of thermo-active ground structures, or as a thermally activated building structure utilizing its own thermal mass conductivity and storage capacity to heat and cool buildings, based on renewable or “free” energy sources. The pipes, filled with a heat carrier fluid, that are embedded into the building´s concrete elements may bring on two different adverse effects on concrete structures. In one hand, the consequence of thermal variations and, on the other hand, because of the fact that the pipes are inside of the concrete mortar and in direct contact with the reinforcing steel bars. For this reason, different types of specimens and testing procedures have been proposed to discuss the effects of temperature (20º, 40ºC, 70ºC y 100ºC) on the performance of two different hardened concrete: H-25 and H-30, and the effects of having the pipes embedded in different positions inside of specimens made of two types of concrete, H-25 and H-30, and with two kind of cast, cylindrical and cubical. The experimental program includes the use of compressive strength test and also pull-out test, in order to investigate the interfacial adhesion quality and interfacial properties between steel bar and concrete. The results of the mechanical test showed that the increase of temperature in hardened concrete specimens lower than 70ºC, and the introduction of embedded pipes placed in parallel to the load, in cylindrical or cubic specimens, does not jeopardize the mechanical properties of concrete with strength decreases higher than 20%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here we show that potassium-doped tungsten foil should be preferred to pure tungsten foil when considering tungsten laminate pipes for structural divertor applications. Potassium-doped tungsten materials are well known from the bulb industry and show an enhanced creep and recrystallization behaviour that can be explained by the formation of potassium-filled bubbles that are surrounding the elongated grains, leading to an interlocking of the microstructure. In this way, the ultra-fine grained (UFG) microstructure of tungsten foil can be stabilized and with it the extraordinary mechanical properties of the foil in terms of ductility, toughness, brittle-to-ductile transition, and radiation resistance. In this paper we show the results of three-point bending tests performed at room temperature on annealed pure tungsten and potassium-doped tungsten foils (800, 900, 1000, 1100, 1200, 1300, 1400, 1600, 1800, 2000, 2200, and 2400 °C for 1 h in vacuum). The microstructural assessment covers the measurement of the hardness and analyses of fractured surfaces as well as a comparison of the microstructure by optical microscopy. The results show that there is a positive effect of potassium-doped tungsten foils compared to pure tungsten foil and demonstrate the potential of the doped foil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current social demand for more environmentally-friendly fuels environment has imposed stringent emissions standards infectious greenhouse affecting all means of transport, including maritime. A few free zones emissions (ECA) in waters around the world have been established. This has driven to the Liquefied Natural Gas (LNG) as the fuel of the future for ships to comply with emissions laid down by the Convention International Prevention of the Pollution from Ships (MARPOL). The present work proposes the installation of a LNG station for ships in the future regasification plant of Granadilla (Santa Cruz de Tenerife). The work has understood the design and sizing of the receiving of the regasification plant terminal pipelines, as well as pipes for the LNG station. La demanda social actual por combustibles más respetuosos con el medio ambiente ha impuesto unas estrictas normas de emisiones de gases infecto invernadero que afectan a todos los medios de transporte, incluido el marítimo. Se han establecido unas zonas libres de emisiones (ECA) en aguas de todo el mundo. Esto ha impulsado al Gas Natural Licuado (GNL) como el combustible del futuro para buques para cumplir con las emisiones fijadas por la Convención Internacional de Prevención de la Contaminación de Barcos (MARPOL). El presente trabajo propone la instalación de una gasinera para buques en la futura planta de regasificación de Granadilla (Santa Cruz de Tenerife). El trabajo ha comprendido el diseño y dimensionamiento de las tuberías de la terminal de recepción de la planta de regasificación, así como las tuberías para la gasinera.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La implantación de una gran obra de paso facilita en multitud de ocasiones la vida de aquellos que aprovechen las ventajas que ofrece esta estructura. Sin embargo, el camino que lleva a su construcción supone importantes y tortuosos retos cuando el terreno de cimentación presenta condiciones geotécnicas no compatibles con las grandes cargas que el viaducto necesita transmitirle para su buen funcionamiento. El trabajo que desarrolla esta Tesis Doctoral proporciona una herramienta eficaz y económica, por lo reducido de su extensión y medios, que permite allanar el camino que acomete la construcción de una estructura de tal envergadura. Mediante el análisis de la problemática del terreno y de las distintas soluciones de cimentación empleadas en la actualidad, se conduce al lector hacia una técnica de cimentación innovadora que combina la técnica del micropilotaje, para la canalización de las cargas estructurales, junto a la técnica de la inyección de fracturación hidráulica, que mejorará el terreno de implantación de los micropilotes, conformando así un medio capaz de recibir y transmitir grandes cargas en cualquier tipo de terreno. La técnica ya empleada del micropilotaje, por su trabajo esencialmente axil, requiere, aunque sin problema, la constitución de sistemas de fuerzas que equilibren el sistema de cargas provenientes del viaducto. Pero su capacidad resistente viene condicionada por el terreno circundante. Cuando la roca rodea el micropilote, su empleo se realiza sin problema y sin necesidad de mejorar el terreno. Pero sin terreno consistente, el empleo de inyecciones de fracturación hidráulica a través de los propios micropilotes, no sólo mejorará la capacidad resistente de los micropilotes, aumentando la inercia necesaria cuando las cargas son de origen sísmico o estructural ferroviario, sino que resolverá y eliminará los problemas de estabilidad que presentan las laderas que frecuentemente deben recibir las cargas de la obra de paso. Tras recoger el análisis ya realizado en el Trabajo de Investigación, donde se justificaba la alta capacidad resistente de un micropilote con terreno circundante mejorado por la inyección, en la actual Tesis se emplean modelos matemáticos sobre un caso real de viaducto sometido a un gran sismo e implantado en una enorme quebrada (500 m) de Colombia, sujeta a lluvias torrenciales y en la zona de mayor sismicidad del país. Con ello se comprueba la estabilización que se alcanza en el terreno de cimentación con el empleo de esta técnica de transmisión de carga y mejora del terreno. De esta forma se completa un ciclo que justifica las bondades de esta combinación de técnicas de cimentación, pero se abren las puertas a nuevos entornos de aplicación, como edificios antiguos de cualquier tipo que requieran recalces, y no sólo en la implantación de grandes obras de paso. ABSTRACT The establishment of a large bridge represents, in many cases, a better life for those who can take profit of the advantages provided by that structure. Nevertheless, the process of building this structure has to overcome important and difficult circumstances whenever the geotechnical conditions of the bridge site are not adequate to carry the large loads transmitted by the bridge structure. This study develops a method both effective and economical, due to the extension and means necessary for its application, which allows to solve properly the foundation of a structure of that importance. Considering the geotechnical problems inherent to the bridge site, along with the different foundation solutions that are presently used and their limitations, the study leads the reader to an innovative technique which combines the micropile system, for transmission of the structural loads of the bridge, with the technique of hydraulic fracture grouting for improvement of the ground around the micropiles, allowing to both stabilizing and transmitting large loads in any kind of ground. It is well known that the micropiles work axially, and this condition requires an adequate distribution of those units, in order to properly absorb the load system introduced by the viaduct. The resistance of the bridge foundation is, in any case, provided by the ground. When rock is encountered, the micropiles have been successfully used without improving the ground. However, as it is shown in this study, by using the micropiles as sleeve-pipes for hydraulic fracture grouting, not only the micropile resistance can be improved in any ground, but it is possible to develop grouted “solids” in the ground, whose inertia allows to absorb actions of structural and seismic origin. Additionally, as it is shown and analyzed in the Thesis, the ground improvement can give an adequate safety factor to the slopes frequently encountered in bridge sites. In order to properly justify those advantages of combining micropiles with ground improvement through fracture grouting around the micropiles, mathematical models have been developed and applied to a real case of a cable-stayed bridge installed on a very large ravine (500 m) in Colombia, located in the highest seismic zone of the country, and subject to torrential rains. The results of this numerical analysis show the high safety condition provided by the ground improvement to the viaduct site. In conclusion, the Thesis shows the important improvement that can be provided by the combination of micropiles and soil improvement, through fracture grouting, to the problem of founding bridges. However, it can be understood that this technique could be applied successfully to underpinning buildings, specially old buildings of any type, apart from its use in bridge foundations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El control del estado en el que se encuentran las estructuras ha experimentado un gran auge desde hace varias décadas, debido a que los costes de rehabilitación de estructuras tales como los oleoductos, los puentes, los edificios y otras más son muy elevados. En las últimas dos décadas, se han desarrollado una gran cantidad de métodos que permiten identificar el estado real de una estructura, basándose en modelos físicos y datos de ensayos. El ensayo modal es el más común; mediante el análisis modal experimental de una estructura se pueden determinar parámetros como la frecuencia, los modos de vibración y la amortiguación y también la función de respuesta en frecuencia de la estructura. Mediante estos parámetros se pueden implementar diferentes indicadores de daño. Sin embargo, para estructuras complejas y grandes, la implementación de metodologías basadas en la función de respuesta en frecuencia requeriría realizar hipótesis sobre la fuerza utilizada para excitar la estructura. Dado que el análisis modal operacional utiliza solamente las señales de respuesta del sistema para extraer los parámetros dinámicos estructurales y, por tanto, para evaluar el estado de una estructura, el uso de la transmisibilidad sería posible. En este sentido, dentro del análisis modal operacional, la transmisibilidad ha concentrado mucha atención en el mundo científico en la última década. Aunque se han publicado muchos trabajos sobre el tema, en esta Tesis se proponen diferentes técnicas para evaluar el estado de una estructura basándose exclusivamente en la transmisibilidad. En primer lugar, se propone un indicador de daño basado en un nuevo parámetro, la coherencia de transmisibilidad; El indicador se ha valido mediante resultados numéricos y experimentales obtenidos sobre un pórtico de tres pisos. En segundo lugar, la distancia de Mahalanobis se aplica sobre la transmisibilidad como procedimiento para detectar variaciones estructurales provocadas por el daño. Este método se ha validado con éxito sobre una viga libre-libre ensayada experimentalmente. En tercer lugar, se ha implementado una red neuronal basada en medidas de transmisibilidad como metodología de predicción de daño sobre una viga simulada numéricamente. ABSTRACT Structural health monitoring has experienced a huge development from several decades ago since the cost of rehabilitation of structures such as oil pipes, bridges and tall buildings is very high. In the last two decades, a lot of methods able to identify the real stage of a structure have been developed basing on both models and experimental data. Modal testing is the most common; by carrying out the experimental modal analysis of a structure, some parameters, such as frequency, mode shapes and damping, as well as the frequency response function of the structure can be obtained. From these parameters, different damage indicators have been proposed. However, for complex and large structures, any frequency domain approach that relies on frequency response function estimation would be of difficult application since an assumption of the input excitations to the system should be carried out. Operational modal analysis uses only output signals to extract the structural dynamic parameters and, therefore, to identify the structural stage. In this sense, within operational modal analysis, transmissibility has attracted a lot of attention in the scientific field in the last decade. In this work new damage detection approaches based on transmissibility are developed. Firstly, a new theory of transmissibility coherence is developed and it is tested with a three-floor-structure both in simulation and in experimental data analysis; secondly, Mahalanobis distance is taken into use with the transmissibility, and a free-free beam is used to test the approach performance; thirdly, neural networks are used in transmissibility for structural health monitoring; a simulated beam is used to validate the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El control del estado en el que se encuentran las estructuras ha experimentado un gran auge desde hace varias décadas, debido a que los costes de rehabilitación de estructuras tales como los oleoductos, los puentes, los edificios y otras más son muy elevados. En las últimas dos décadas, se han desarrollado una gran cantidad de métodos que permiten identificar el estado real de una estructura, basándose en modelos físicos y datos de ensayos. El ensayo modal es el más común; mediante el análisis modal experimental de una estructura se pueden determinar parámetros como la frecuencia, los modos de vibración y la amortiguación y también la función de respuesta en frecuencia de la estructura. Mediante estos parámetros se pueden implementar diferentes indicadores de daño. Sin embargo, para estructuras complejas y grandes, la implementación de metodologías basadas en la función de respuesta en frecuencia requeriría realizar hipótesis sobre la fuerza utilizada para excitar la estructura. Dado que el análisis modal operacional utiliza solamente las señales de respuesta del sistema para extraer los parámetros dinámicos estructurales y, por tanto, para evaluar el estado de una estructura, el uso de la transmisibilidad sería posible. En este sentido, dentro del análisis modal operacional, la transmisibilidad ha concentrado mucha atención en el mundo científico en la última década. Aunque se han publicado muchos trabajos sobre el tema, en esta Tesis se proponen diferentes técnicas para evaluar el estado de una estructura basándose exclusivamente en la transmisibilidad. En primer lugar, se propone un indicador de daño basado en un nuevo parámetro, la coherencia de transmisibilidad; El indicador se ha valido mediante resultados numéricos y experimentales obtenidos sobre un pórtico de tres pisos. En segundo lugar, la distancia de Mahalanobis se aplica sobre la transmisibilidad como procedimiento para detectar variaciones estructurales provocadas por el daño. Este método se ha validado con éxito sobre una viga libre-libre ensayada experimentalmente. En tercer lugar, se ha implementado una red neuronal basada en medidas de transmisibilidad como metodología de predicción de daño sobre una viga simulada numéricamente. ABSTRACT Structural health monitoring has experienced a huge development from several decades ago since the cost of rehabilitation of structures such as oil pipes, bridges and tall buildings is very high. In the last two decades, a lot of methods able to identify the real stage of a structure have been developed basing on both models and experimental data. Modal testing is the most common; by carrying out the experimental modal analysis of a structure, some parameters, such as frequency, mode shapes and damping, as well as the frequency response function of the structure can be obtained. From these parameters, different damage indicators have been proposed. However, for complex and large structures, any frequency domain approach that relies on frequency response function estimation would be of difficult application since an assumption of the input excitations to the system should be carried out. Operational modal analysis uses only output signals to extract the structural dynamic parameters and, therefore, to identify the structural stage. In this sense, within operational modal analysis, transmissibility has attracted a lot of attention in the scientific field in the last decade. In this work new damage detection approaches based on transmissibility are developed. Firstly, a new theory of transmissibility coherence is developed and it is tested with a three-floor-structure both in simulation and in experimental data analysis; secondly, Mahalanobis distance is taken into use with the transmissibility, and a free-free beam is used to test the approach performance; thirdly, neural networks are used in transmissibility for structural health monitoring; a simulated beam is used to validate the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las fuentes como parte de la ingeniería hidráulica, quizás menor, de nuestro país son elementos urbanos, funcionales y de gran interés en el pasado, que poco a poco han ido en decadencia desde la traída de aguas domiciliares. No obstante, entre nosotros, hay magníficas obras de ingeniería muy bien estudiadas y ejecutadas técnicamente pero que a la par representan elementos artísticos de gran interés y representatividad. No en vano en la última ley de Patrimonio Histórico Artístico de la Comunidad de Madrid (ley 3/2013), se requiere su estudio y catalogación a nivel municipal. La técnica de su diseño, es bien conocida desde muy antiguo. Ya los romanos hacían uso de una precisión milimétrica para el cálculo de las pendientes de las conducciones subterráneas que llevaban el agua intacta hasta su destino tras recorrer decenas de kilómetros sin necesidad de energía externa para ello. La calidad de sus aguas, muy ligada al sustrato determinaba en gran medida asentamientos y usos que según su popularidad, podían incluso restringirse a distintos niveles sociales La obra arquitectónica asociada, también cobraba especial relevancia por su singularidad, monumentalidad y aspecto. Muchas son las tendencias arquitectónicas que se dan cita en las fuentes estudiadas, que además, encierran tras de sí gran riqueza de carácter histórico. Esta investigación se centra en el inventariado, catalogación y caracterización de una muestra representativa de fuentes naturales madrileñas (550 fuentes), el estudio pormenorizado de las variables utilizadas en su caracterización, a través de tratamientos inferenciales, y el diseño experimental “ad hoc” de una propuesta metodológica de catalogación y caracterización 360° (desde la captación hasta la salida de aguas por el caño). La investigación finaliza con la puesta en práctica de la metodología diseñada, a través del estudio, catalogación y caracterización de un caso concreto. La presente investigación se centra en la Comunidad de Madrid, pero la propuesta metodológica que se propone como aportación, es extrapolable a cualquier tipo de fuente en cualquier municipio. Con todo ello, se pretende poner en valor estas obras de ingeniería ignorada, y contribuir de alguna forma a su preservación, facilitando su catalogación y difundiendo su existencia. As a minor relevant part of hydraulic engineering, the fountains of our country are urban, functional and of great interest in the past. The relevancy of these fountains has gradually declined since the emergence of general water supply. However, in our environment, there are magnificent works of engineering very well studied and executed, that also represent good examples of art and historical interest. In this way, the Historical and Artistic Heritage Law of the Community of Madrid (Ley 3/2013), requests the councils, their study and categorization. Their technical design is well known since ancient times. Even the Romans were able to use pinpoint accuracy (just a few millimeters), to calculate the slopes of the underground pipes which supply water, in perfect conditions, to its target, and without using external sources of energy. In this cases, the water quality of which was obviously linked to the type of substrate, conditioned the settlements and even its use, that could be restricted to certain social classes. In some cases, the engineering works of these fountains were especially relevant for its uniqueness, monumentality and appearance. There are many architectural trends that come together in the studied fountains, which also contain of its own historical character. This research is focused on inventory categorization and characterization of a representative sample of 550 natural fountains in Madrid. It includes the detailed study of the variables used in its characterization, through inferential treatments, and the "ad hoc" experimental design of a methodology for the categorization and a 360 ° characterization, from the catchment to the spout. Finally, the research ends with the implementation of the designed methodology, through the study, categorization and characterization of a specific case. Although this research is focused on fountains from Madrid surroundings, the main value is that the purposed methodology can be extrapolated to to manyother cases. To highlight these ignored engineering works, and contribute to its preservation making easier their categorization and spreading their existence, set the main aim of this research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El consumo de energía es responsable de una parte importante de las emisiones a la atmósfera de CO2, que es uno de los principales causantes del efecto invernadero en nuestro planeta. El aprovechamiento de la energía solar para la producción de agua caliente, permite economizar energía y disminuir el impacto del consumo energético sobre el medio ambiente y por tanto un menor impacto medioambiental. El objetivo de la presente investigación consiste en estudiar el aprovechamiento solar para el calentamiento de los fangos en los digestores anaerobios mediante agua caliente circulando en el interior de un serpentín que rodea la superficie de dicho digestor, como apoyo a los métodos convencionales del calentamiento de fangos como la resistencia eléctrica o el intercambiador de calor mediante la energía obtenida por el gas metano producido en la digestión anaerobia. Para el estudio se utilizaron 3 digestores, dos delos cuales se calentaron con agua caliente en el interior de un serpentín (uno aislado mediante una capa de fibra de vidrio y poliuretano y otro sin aislar).El tercer digestor no tenía calentamiento exterior con el objetivo de observar su comportamiento y comparar su evolución con el resto de los digestores .La comparación de los digestores 1 y 2 nos permitió estudiar la conveniencia de proveer de aislamiento al digestor. La transferencia de calor mediante serpentín de cobre dio valores comprendidos entre 83 y 92%. La aplicación de la instalación a una depuradora a escala real para mantenimiento en el interior del digestor a T=32ºC en diferentes climas: climas templados, cálidos y fríos, consistió en el cálculo de la superficie de colectores solares y superficie de serpentín necesario para cubrir las necesidades energéticas anuales de dicho digestor, así como el estudio de rentabilidad de la instalación, dando los mejores resultados para climas cálidos con períodos de retorno de 12 años y una tasa interna de rentabilidad (TIR) del 16% obteniendo una cobertura anual del 79% de las necesidades energéticas con energía solar térmica. Energy consumption accounts for a significant part of the emissions of CO2, which is one of the main causes of the greenhouse effect on our planet. The use of solar energy for hot water production. can save energy and reduce the impact of energy consumption on the environment and therefore a reduced environmental impact. The objective of this research is to study the solar utilization for heating the sludge in anaerobic digesters by hot water circulating inside a coil surrounding the surface of digester, to support conventional heating methods sludge as the electrical resistance or heat exchanger by energy generated by the methane gas produced in the anaerobic digestion. To study 3 digesters used two models which are heated with hot water within a coil (one insulated by a layer of fiberglass and polyurethane and other uninsulated) .The third digester had no external heating in order to observe their behavior and compare their evolution with the rest of the .The comparison digesters digesters 1 and 2 allowed us to study the advisability of providing insulation to the digester. Heat transfer through copper coil gave values between 83 and 92%. The installation application to a treatment for maintaining full scale within the digester at T = 32ºC in different climates: temperate, warm and cold climates, consisted of calculating the surface area of solar collectors and coil required to cover the annual energy needs of the digester, and the study of profitability of the installation, giving the best results for hot climates with return periods of 12 years and an internal rate of return (IRR) of 16% achieving an annual coverage of 79 % of energy needs with solar energy.