576 resultados para Femur


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies indicate that the number of hip bone fractures caused by osteoporosis may rise from 1.66 to 6.26 million until 2050, worldwide. For this reason, implementation of preventive measures becomes a necessity. Female individuals are usually more affected due to a variety of factors including old age, early menopause, chronicle disease in the family history, calcium deficit, as well as the lack of physical exercise (sedentary individual). The aim of this study was to estimate the incidence of hip and lower limb fracture in female individuals’ resident in Aracaju city. From the period of January 2008-2009, around of 300 fracture cases were of lower limb analyzed from females. The incidence of femur fractures in women increased according to age group, 66.17 individuals per 10,000 inhabitants (over 60 years-old). These findings allow us to conclude that the incidence of hip and lower limb bone fractures among women over 60 years were more significant in the femur.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the marine Jurassic deposits of Europe, a group of marine crocodilians, the Thalattosuchia, belongs to the frequently found reptiles. Thalattosuchia are widely spread in Central Europe from the Jurassic to Lower Cretaceous, and some taxa are also distributed worldwide. The task of the work was to examine all taxa known from the Liassic of Europe. The most frequently known taxa Steneosaurus bollensis and Pelagosaurus typus are anatomically revised. New discoveries at the skull of Pelagosaurus typus e.g., the fact of a partly paired frontal are described by means of computed tomography investigations. In addition, juvenile specimens of this taxon are studied in detail for the first time. The rarely occurring taxon Platysuchus multiscrobiculatus is anatomically described in detail for the first time. It shows both in the skull and in the postcranial material morphological differences to Steneosaurus bollensis and Pelagosaurus typus. Thus Pl. multiscrobiculatus possesses, e.g., an ilium with a deeper acetabulum and a femur with a distinctly flexed femoral head. A juvenile specimen of Pl. multiscrobiculatus is now discovered and is described in parts for the first time, too. Furthermore, Steneosaurus gracilirostris and Steneosaurus brevior known from Lower Jurassic deposits of England are examined and in parts revised. In this work, Steneosaurs brevior is discovered with one specimen from the Upper Liassic of Holzmaden, Germany for the first time, and provides new evidence for the palaeobiogeographical distribution of the taxon. Because of the high number of investigated specimens, it is possible to study ontogenetic development from juvenile to adult stage in Steneosaurus bollensis, Pelagosaurus typus, and Platysuchus multiscrobiculatus. Biometric data are collected from thalattosuchians and extant crocodilians (e.g. Gavialis gangeticus) to investigate intraspecific variation, ontogenetic development, and taxa differentiation. The skulls of Platysuchus multiscrobiculatus and Steneosaurus bollensis are reconstructed three-dimensionally as wax models. The skull reconstructions form the basis of the jaw muscle restoration of Steneosaurus bollensis in connection with comparative studies at extant crocodilians. By means of functional morphologic analysis of the jaw musculature, the dentition, and the locomotor system of S. bollensis, possible conclusions are drawn for the prey options and the hunting behaviour. To clarify the relationships within the Thalattosuchia, a computer-based cladistic phylogenetic in-group analyse of 25 Thalattosuchia taxa is performed. For the analysis, following Thalattosuchia taxa are studied likewise at original material for comparisons: Metriorhynchus superciliosus, Metriorhynchus hastifer, Metriorhynchus leedsi, Geosaurus gracilis, Geosaurus giganteus, Teleidosaurus calvadosi, Teleidosaurus gaudryi, Teleosaurus cadomensis, Teleosaurus geoffroyi, Steneosaurus priscus, Steneosaurus edwardsi, Steneosaurus heberti, Steneosaurus leedsi, Steneosaurus boutilieri, Steneosaurus megarhinus, Steneosaurus obtusidens, and Machimosaurus hugii. The phylogenetic in-group analyse based on 115 characters, reveals a sister-group relationship of the monophyletic Teleosauridae and monophyletic Metriorhynchidae. Within the groups, some taxa are probably paraphyletic. The taxon Pelagosaurus typus is nested inside the Teleosauridae and not outside or within the Metriorhynchidae, as many authors suggested it so far. Based on these results, a tentative palaeobiogeographical-evolutionary scenario is developed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obiettivo: Il nostro obiettivo è stato quello di confrontare la tomoterapia (HT) e la protonterapia ad intensità modulata (IMPT) nel trattamento del tumore prostatico, seguendo un protocollo di boost simultaneo (SIB) e moderatamente ipofrazionato. Materiali e metodi: Abbiamo selezionato 8 pazienti, trattati con HT e abbiamo rielaborato i piani con 2 campi IMPT. La dose prescritta è stata di 74 Gy sul PTV1 (prostata e vescicole seminali prossimali), 65.8 Gy sul PTV2 (vescicole seminali distali) e 54 Gy sul PTV3 (linfonodi pelvici). Risultati: Sia con IMPT che con HT abbiamo ottenuto una copertura e una omogeneità di dose del target sovrapponibile. Oltre i 65 Gy, HT e IMPT erano equivalenti per il retto, mentre con l’IMPT c’era maggior risparmio della vescica e del bulbo penieno da 0 a 70 Gy. Da 0 fino a 60 Gy, i valori dosimetrici dell’IMPT erano molto più bassi per tutti gli organi a rischio (OARs), eccetto che per le teste femorali, dove la HT aveva un vantaggio dosimetrico rispetto all’IMPT nel range di dose 25-35 Gy. La dose media agli OARs era ridotta del 30-50% con l’IMPT. Conclusioni: Con le due tecniche di trattamento (HT e IMPT) si ottiene una simile distribuzione di dose nel target. Un chiaro vantaggio dosimetrico dell’IMPT sul HT è ottenuto dalle medie e basse dosi. Le attuali conoscenze sulle relazioni dose-effetto e sul risparmio delle madie e basse dosi con l’IMPT non sono ancora state quantificate dal punto di vista clinico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La rottura del Legamento Crociato Craniale (LCCr) rappresenta una delle patologie ortopediche di maggiore riscontro clinico nella specie canina. In seguito a rottura del LCCr si presenta un continuo slittamento craniale della tibia il quale esita in un processo osteoartrosico. La risoluzione chirurgica rappresenta la migliore soluzione terapeutica. Le tecniche chirurgiche extra-articolari con sfruttamento dei punti isometrici del ginocchio si presentano come delle procedure molto diffuse e utilizzate. Questa tesi propone di validare l’uso di un nuovo sistema di navigazione computerizzato-assistito per la valutazione cinematica durante la ricostruzione del LCCr nel cane, ma soprattutto di studiare e confrontare il comportamento e l’efficacia dopo ricostruzione TightRope (TR) in due diverse coppie di punti isometrici. Abbiamo effettuato due analisi in parallelo. La prima eseguendo interventi chirurgici con tecnica TR su 18 casi clinici e sfruttando il punto isometrico del femore (F2) e due diversi punti isometrici della tibia (T2 o T3). L’analisi prevedeva dei controlli postoperatori a 1, 3 e 6 mesi. Ad ogni controllo veniva effettuata una visita ortopedica, esami radiografici, un questionario di valutazione clinico e di soddisfazione del proprietario. Mentre nella ricerca Ex-Vivo abbiamo eseguito dei test su 14 preparati anatomici con l’utilizzo di un sistema di navigazione computerizzato per la rilevazione dei dati. L’analisi prevedeva la valutazione dell’articolazione in diversi stadi: LCCr intatto; LCCr rotto; dopo ricostruzione con TR in F2-T2 e tensionato a 22N, 44N e 99N; dopo ricostruzione con TR in F2-T3 e tensionato a 22N, 44N e 99N. Ad ogni stadio si eseguivano cinque test di valutazione, tra cui: Test del Cassetto, Test di compressione tibiale (TCT), Rotazione Interna/Esterna, Flesso/Estensione e Varo/Valgo. Lo scopo di tale studio è quello di confrontare tra loro i punti isometrici del ginocchio e di analizzare l’efficacia della tecnica TR nelle due differenti condizioni di isometria (F2-T2 e F2-T3).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The evaluation of the knee joint behavior is fundamental in many applications, such as joint modeling, prosthesis and orthosis design. In-vitro tests are important in order to analyse knee behavior when simulating various loading conditions and studying physiology of the joint. A new test rig for in-vitro evaluation of the knee joint behavior is presented in this paper. It represents the evolution of a previously proposed rig, designed to overcome its principal limitations and to improve its performances. The design procedure and the adopted solution in order to satisfy the specifications are presented here. Thanks to its 6-6 Gough-Stewart parallel manipulator loading system, the rig replicates general loading conditions, like daily actions or clinical tests, on the specimen in a wide range of flexion angles. The restraining actions of knee muscles can be simulated when active actions are simulated. The joint motion in response to the applied loads, guided by passive articular structures and muscles, is permitted by the characteristics of the loading system which is force controlled. The new test rig guarantees visibility so that motion can be measured by an optoelectronic system. Furthermore, the control system of the new test rig allows the estimation of the contribution of the principal leg muscles in guaranteeing the equilibrium of the joint by the system for muscle simulation. Accuracy in positioning is guaranteed by the designed tibia and femur fixation systems,which allow unmounting and remounting the specimen in the same pose. The test rig presented in this paper permits the analysis of the behavior of the knee joint and comparative analysis on the same specimen before and after surgery, in a way to assess the goodness of prostheses or surgical treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays the number of hip joints arthroplasty operations continues to increase because the elderly population is growing. Moreover, the global life expectancy is increasing and people adopt a more active way of life. For this reasons, the demand of implant revision operations is becoming more frequent. The operation procedure includes the surgical removal of the old implant and its substitution with a new one. Every time a new implant is inserted, it generates an alteration in the internal femur strain distribution, jeopardizing the remodeling process with the possibility of bone tissue loss. This is of major concern, particularly in the proximal Gruen zones, which are considered critical for implant stability and longevity. Today, different implant designs exist in the market; however there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. The aim of the study is to investigate the stress shielding effect generated by different implant design parameters on proximal femur, evaluating which ranges of those parameters lead to the most physiological conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of a 78-year-old female with a proximal femur fracture caused by an accidental fall who died suddenly 1h after orthopaedic prosthesis insertion. Post-mortem computed tomography (CT) scan and histological examination of samples obtained with post-mortem percutaneous needle biopsies of both lungs were performed. Analysis of the medical history and the clinical scenario immediately before death, imaging data, and biopsy histology established the cause of death without proceeding to traditional autopsy. It was determined to be acute right ventricular failure caused by massive pulmonary fat embolism. Although further research in post-mortem imaging and post-mortem tissue sampling by needle biopsies is necessary, we conclude that the use of CT techniques and percutaneous biopsy, as additional tools, can offer a viable alternative to traditional autopsy in selected cases and may increase the number of minimally invasive forensic examinations performed in the future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surgical procedures with use of traditional techniques to reposition the proximal femoral epiphysis in the treatment of slipped capital femoral epiphysis are associated with a high rate of femoral head osteonecrosis. Therefore, most surgeons advocate in situ fixation of the slipped epiphysis with acceptance of any persistent deformity in the proximal part of the femur. This residual deformity can lead to secondary osteoarthritis resulting from femoroacetabular cam impingement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nonunions of pediatric subtrochanteric femur fractures are exceedingly rare and have to date not been reported in the literature. We present the case of an 11-year-old boy who developed such a nonunion after open reduction internal fixation using a pediatric locked proximal femur plate. Using an adult proximal humerus locking plate, adequate proximal fixation of the nonunion was obtained. Furthermore, previously placed distal screw holes were safely bridged and the biomechanical environment around the nonunion site improved. Uneventful healing was possible with the use of adjuvant bone grafting. No short- or midterm complications occurred. Although other implants can certainly be adapted to a use different than that of its original design, the present case suggests that adult proximal humerus locking plates may be a safe option for revision surgery of the proximal pediatric femur.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Femoro-acetabular impingement can cause pain and degenerative changes of the hip joint. Traditionally, surgical dislocation of the hip joint has been performed for correction of pathologic abnormalities in the proximal part of the femur and the acetabulum. Failures of surgical treatment are often related to postoperative pain in the groin or in the area of the greater trochanter, associated with this surgical approach. The aim of our study was to determine the prevalence and functional impact of pain at the greater trochanter after surgical dislocation of the hip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Automatic scan planning for magnetic resonance imaging of the knee aims at defining an oriented bounding box around the knee joint from sparse scout images in order to choose the optimal field of view for the diagnostic images and limit acquisition time. We propose a fast and fully automatic method to perform this task based on the standard clinical scout imaging protocol. The method is based on sequential Chamfer matching of 2D scout feature images with a three-dimensional mean model of femur and tibia. Subsequently, the joint plane separating femur and tibia, which contains both menisci, can be automatically detected using an information-augmented active shape model on the diagnostic images. This can assist the clinicians in quickly defining slices with standardized and reproducible orientation, thus increasing diagnostic accuracy and also comparability of serial examinations. The method has been evaluated on 42 knee MR images. It has the potential to be incorporated into existing systems because it does not change the current acquisition protocol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In implant dentistry, there is a need for synthetic bone substitute blocks to support ridge augmentation in situations where large bone volumes are missing. Polycaprolactone-based scaffolds demonstrated excellent results in bone tissue engineering applications. The use of customized polycaprolactone-tricalcium phosphate (PCL-TCP) displayed promising results from recent rat femur and rabbit calvaria studies. However, data from clinically representative models in larger animals do not exist.