993 resultados para Fabry-Perot Lasers
Resumo:
This thesis aims to investigate the interaction of acoustic waves and fiber Bragg gratings (FBGs) in standard and suspended-core fibers (SCFs), to evaluate the influence of the fiber, grating and modulator design on the increase of the modulation efficiency, bandwidth and frequency. Initially, the frequency response and the resonant acoustic modes of a low frequency acousto-optic modulator (f < 1.2 MHz) are numerically investigated by using the finite element method. Later, the interaction of longitudinal acoustic waves and FBGs in SCFs is also numerically investigated. The fiber geometric parameters are varied and the strain and grating properties are simulated by means of the finite element method and the transfer matrix method. The study indicates that the air holes composing the SCF cause a significant reduction of the amount of silica in the fiber cross section increasing acousto-optic interaction in the core. Experimental modulation of the reflectivity of FBGs inscribed in two distinct SCFs indicates evidences of this increased interaction. Besides, a method to acoustically induce a dynamic phase-shift in a chirped FBG employing an optimized design of modulator is shown. Afterwards, a combination of this modulator and a FBG inscribed in a three air holes SCF is applied to mode-lock an ytterbium doped fiber laser. To improve the modulator design for future applications, two other distinct devices are investigated to increase the acousto-optic interaction, bandwidth and frequency (f > 10 MHz). A high reflectivity modulation has been achieved for a modulator based on a tapered fiber. Moreover, an increased modulated bandwidth (320 pm) has been obtained for a modulator based on interaction of a radial long period grating (RLPG) and a FBG inscribed in a standard fiber. In summary, the results show a considerable reduction of the grating/fiber length and the modulator size, indicating possibilities for compact and faster acousto-optic fiber devices. Additionally, the increased interaction efficiency, modulated bandwidth and frequency can be useful to shorten the pulse width of future all-fiber mode-locked fiber lasers, as well, to other photonic devices which require the control of the light in optical fibers by electrically tunable acoustic waves.
Resumo:
Insight into instabilities of fiber laser regimes leading to complex self-pulsing operations is an opportunity to unlock the high power and dynamic operation tunability of lasers. Though many models have been suggested, there is no complete covering of self-pulsing complexity observed experimentally. Here, I further generalized our previous vector model of erbium-doped fiber laser and, for the first time, to the best of my knowledge, map tunability of complex vector self-pulsing on Poincare sphere (limit cycles and double scroll polarization attractors) for laser parameters, e.g., power, ellipticity of the pump wave, and in-cavity birefringence. Analysis validated by extensive numerical simulations demonstrates good correspondence to the experimental results on complex self-pulsing regimes obtained by many authors during the last 20 years.
Resumo:
Dissipative solitons (also known as auto-solitons) are stable, nonlinear, time-or space-localized solitary waves that occur due to the balance between energy excitation and dissipation. We review the theory of dissipative solitons applied to fiber laser systems. The discussion context includes the classical Ginzburg-Landau and Maxwell-Bloch equations and their modifications that allow describing laser-cavity-produced waves. Practical examples of laser systems generating dissipative solitons are discussed.
Resumo:
A turn on of a quantum dot (QD) semiconductor laser simultaneously operating at the ground state (GS) and excited state (ES) is investigated both experimentally and theoretically. We find experimentally that the slow passage through the two successive laser thresholds may lead to significant delays in the GS and ES turn ons. The difference between the turn-on times is measured as a function of the pump rate of change and reveals no clear power law. This has motivated a detailed analysis of rate equations appropriate for two-state lasing QD lasers. We find that the effective time of the GS turn on follows an -1/2 power law provided that the rate of change is not too small. The effective time of the ES transition follows an -1 power law, but its first order correction in ln is numerically significant. The two turn ons result from different physical mechanisms. The delay of the GS transition strongly depends on the slow growth of the dot population, whereas the ES transition only depends on the time needed to leave a repellent steady state.
Resumo:
The use of InGaAs metamorphic buffer layers (MBLs) to facilitate the growth of lattice-mismatched heterostructures constitutes an attractive approach to developing long-wavelength semiconductor lasers on GaAs substrates, since they offer the improved carrier and optical confinement associated with GaAs-based materials. We present a theoretical study of GaAs-based 1.3 and 1.55 μm (Al)InGaAs quantum well (QW) lasers grown on InGaAs MBLs. We demonstrate that optimised 1.3 μm metamorphic devices offer low threshold current densities and high differential gain, which compare favourably with InP-based devices. Overall, our analysis highlights and quantifies the potential of metamorphic QWs for the development of GaAs-based long-wavelength semiconductor lasers, and also provides guidelines for the design of optimised devices.
Resumo:
Fabry disease (FD) is an X‐linked inherited, lysosomal storage disorder characterized by a deficient activity of the enzyme α-Galactosidase A (α-Gal A). This deficiency causes an accumulation of globotriaosylceramide 3 (Gb3), in nearly all organs. Gastrointestinal (GI) symptoms are among the earliest and most frequent symptoms of FD. It has been hypothesized that Gb3 accumulation is the leading cause of these, but their pathophysiology is complex and still poorly understood. Here, we aim at understanding the molecular mechanisms underpinning the GI symptoms of FD. For this purpose, we used the α‐Gal A (-/0) male mouse, a murine model of FD, to characterize morphological and molecular features of the colon tract. Our results show that α‐Gal A (-/0) mice display a thickening of the muscular layer due to a hypertrophic state of myenteric plexus ganglia, caused by an accumulation of Gb3 in neurons. Also, α-Gal A (-/0) mice present a decreased density of mucosal nerve fibres. Furthermore, α-Gal A (-/0) mice presented visceral hyperalgesia, by showing greater visceromotor response (VMR) values and obtaining higher abdominal withdrawal reflex (AWR) scores, following colorectal distension (CRD). Subsequently, the immunoreactivity of the pain-related ion channels TRPV1, TRPV4, TRPA1 and TRPM8 was detected at level of myenteric and submucosal plexus ganglia of both the genotypes. Further studies are required to assess differences of expression between α-Gal A (-/0) and control mice. Finally, we optimized the protocols to obtain three types of primary cultures from mouse intestine to be tested electrophysiologically: a mixed culture containing neurons and glia, an enriched culture of neurons, and one of glia. In summary, we revealed alterations that are likely to be part of the pathophysiological causes of FD GI symptoms. Therefore, together with further studies, this work could help identify new therapeutic targets for the treatment of visceral pain in FD.
Resumo:
ABSTRACT Background Cardiac magnetic resonance (CMR) has been shown as promising diagnostic tool in Anderson-Fabry disease (AFD) cardiomyopathy due to its ability to detect fat deposits through lower native T1 values. However no histological validation has been provided to date. Objectives To correlate CMR and histologic findings in different cardiac stages of AFD focusing on T1 mapping. Methods Fifteen AFD patients (49 years [IQR 39-63], 60% females) undergoing CMR (cines, native T1 and T2 mapping, LGE and post-contrast T1 imaging) and endomyocardial biopsy (EMB, n=11) or septal myectomy (n=4), were retrospectively evaluated. Tissue specimens were analyzed with light/electron microscopy and vacuolization amount calculated as percentages of vacuolated myocytes and vacuolated myocyte area (%VMA) through a quantitative histomorphometric color-based analysis. Results In patients without increased indexed left ventricular mass (LVMi) at CMR (67%), T1 fell as %VMA increased (r= -0.883; p<0.001), whereas no clear relationship was evident once increased LVMi occurred (r= -0.501; p=0.389). At least 45% of vacuolized myocytes and 10% of VMA were needed for low T1 to occur. %VMA positively correlate with maximal wall thickness (MWT, r=0.860, p<0.0001) and LVMi (r= 0.762; p<0.001). Increased MWT and LVMi were present with at least 45% and 80% of vacuolated myocytes, respectively, and 18% and 22% of VMA. Conclusions This study demonstrated an inverse correlation between native T1 and the vacuolization amount in patients without increased LVMi at CMR, providing a histological validation of low native T1 in AFD. Importantly, a significant vacuolization burden was needed before low T1 and left ventricle hypertrophy occurred.
Resumo:
Fabry disease (FD), X-linked metabolic disorder caused by a deficiency in α-galactosidase A activity, leads to the accumulation of glycosphingolipids, mainly Gb3 and lyso-Gb3, in several organs. Gastrointestinal (GI) symptoms are among the earliest and most common, strongly impacting patients’ quality of life. However, the origin of these symptoms and the exact mechanisms of pathogenesis are still poorly understood, thus the pressing need to improve their knowledge. Here we aimed to evaluate whether a FD murine model (α-galactosidase A Knock-Out) captures the functional GI issues experienced by patients. In particular, the potential mechanisms involved in the development and maintenance of GI symptoms were explored by looking at the microbiota-gut-brain axis involvement. Moreover, we sought to examine the effects of lyso-Gb3 on colonic contractility and the intestinal epithelium and the enteric nervous system, which together play important roles in regulating intestinal ion transport and fluid and electrolyte homeostasis. Fabry mice revealed visceral hypersensitivity and a diarrhea-like phenotype accompanied by anxious-like behavior and reduced locomotor activity. They reported also an imbalance of SCFAs and an early compositional and functional dysbiosis of the gut microbiota, which partly persisted with advancing age. Moreover, overexpression of TRPV1 was found in affected mice, and partial alteration of TRPV4 and TRPA1 as well, identifying them as possible therapeutic targets. The Ussing chamber results after treatment with lyso-Gb3 showed an increase in Isc (likely mediated by HCO3- ions movement) which affects neuron-mediated secretion, especially capsaicin- and partly veratridine-mediated. This first characterization of gut-brain axis dysfunction in FD mouse provides functional validation of the model, suggesting new targets and possible therapeutic approaches. Furthermore, lyso-Gb3 is confirmed to be not only a marker for the diagnosis and follow-up of FD but also a possible player in the alteration of the FD colonic ion transport process.
Resumo:
Multidrug-resistant microbial infections represent an exponentially growing problem affecting communities worldwide. Photodynamic therapy is a promising treatment based on the combination of light, oxygen, and a photosensitizer that leads to reactive oxygen species production, such as superoxide (type I mechanism) and singlet oxygen (type II mechanism) that cause massive oxidative damage and consequently the host cell death. Indigofera genus has gained considerable interest due its mutagenic, cytotoxic, and genotoxic activity. Therefore, this study was undertaken to investigate the effect of crude extracts, alkaloidal fraction, and isolated substance derived from Indigofera truxillensis in photodynamic antimicrobial chemotherapy on the viability of bacteria and yeast and evaluation of mechanisms involved. Our results showed that all samples resulted in microbial photoactivation in subinhibitory concentration, with indigo alkaloid presenting a predominant photodynamic action through type I mechanism. The use of CaCl2 and MgCl2 as cell permeabilizing additives also increased gram-negative bacteria susceptibility to indigo.
Resumo:
The aim of this study was to determine the effectiveness and reliability of laser fluorescence measurements in relation to occlusal caries diagnosis. DIAGNOdent 2095 (Kavo, Biberach, Germany), which has been developed especially for caries diagnosis, was utilized. Five (5) teeth were examined in the pilot test; after that, ten (10) teeth were examined in order to calibrate both examiners. Data were obtained from 66 teeth (36 molars and 30 premolars), totalizing 144 sites identified through photographs of the occlusal surfaces. Reproducibility was evaluated in 10 teeth. The interexaminer Spearman correlation (r) was 0.89 and the intra-examiner, 0.93 and 0.97 (examiner A and B, respectively). Validation was carried out by histological examination (stereomicroscope). For the two examiners the sensitivity of the device was relatively high, varying from 0.81 to 1.00, while specificity varied according to which validation criterion was used (0.77 - 0.86: enamel lesion / 0.52 - 0.59: dentin lesion). It was concluded that DIAGNodent presented good capacity of identifying any alteration of the dental surface, nevertheless it presents the disadvantage of accomplishing many false-positive diagnosis when the validation criterion is dentin lesion.
Resumo:
PURPOSE: To evaluate changes in retinal nerve fiber layer thickness as measured by scanning laser polarimetry (SLP) after the use of medication to reduce intraocular pressure (IOP) in glaucomatous or ocular hypertensive patients. METHODS: The authors prospectively enrolled 37 eyes of 37 patients in whom IOP was reduced by more than 25% after the use of medication. The images were obtained before and 15 to 30 days after the introduction of medication. The SLP parameters measured before and after the use of medication were compared using paired Student's t Test. RESULTS: The mean IOP was significantly reduced from 26.57±4.23 mmHg to 16.54 ±2.92 mmHg after the use of medication (p<0.05). None of the 10 SLP analyzed parameters was significantly affected by the reduction of IOP with medication (p>0.05). CONCLUSION: The retinal nerve fiber layer thickness, as measured by SLP, is not affected by the reduction of IOP with medication in patients with glaucoma or ocular hypertension.
Resumo:
The aim of this study was to verify the drying effect on the reproducibility of DIAGNOdent (Dd) devices to detect caries-like lesions. Three areas were created in each of the 34 bovine incisors: sound (S), demineralized (DE) and remineralized (RE). One examiner measured each area with two Dd devices (denominated X and Y), twice under humid, and twice under dry condition. Intra-rater agreement according each device and inter-device agreement were estimated by kappa statistics (k). Intra-rater agreement for device Y was substantial under humid (k DE=0.68 and k RE+S=0.68) and dry condition (k DE=0.64 and k RE+S=0.67). For device X, it was substantial under humid condition (k DE=0.57 and k RE+S=0.49), and it was almost perfect after air drying (k DE=1.0 and kRE+S=1.0). Inter-device agreement was slight (k =0.17) under humid condition, and it was substantial under dry condition (k =0.62). As reproducibility increased under dry condition, drying is advised to detect caries-like lesions on free smooth surfaces when different devices are used.
Resumo:
A disfunção têmporo-mandibular é caracterizada pela presença de sintomatologia dolorosa articular/muscular na região da face. A principal justificativa do uso do laser da laserterapia na disfunção é seu efeito analgésico, fato observado na maioria dos estudos encontrados na literatura. OBJETIVO: Foi avaliar a eficácia da laserterapia no tratamento das disfunções têmporo-mandibulares. MATERIAL E MÉTODO: 50 voluntários com disfunção têmporo-mandibular foram divididos em dois grupos (controle e experimental) tiveram as amplitudes dos movimentos de abertura bucal, lateralidade direita e esquerda registrados, antes e após aplicação do laser. Foi registrada, também, a nota de dor do indivíduo através da escala analógica visual de dor e, através do exame físico, os pontos álgicos. Utilizou-se o laser de AsGaAl com potência de 40mW, com 80J/cm², por 16 segundos, em quatro pontos selecionados por apenas uma sessão com reavaliação após uma semana. Desenho Científico Utilizado: Clínico. RESULTADOS: Notou-se que a laserterapia promoveu aumento da média de amplitude dos movimentos mandibulares (p=0,0317) e houve redução significativa (43,6%) da intensidade de dor dos pacientes medida através da escala analógica visual de dor. CONCLUSÕES: A laserterapia promove redução da sintomatologia dolorosa do paciente após a aplicação por ação analgésica e/ou por um efeito placebo.