835 resultados para Error correction codes


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of presence/absence data in wildlife management and biological surveys is widespread. There is a growing interest in quantifying the sources of error associated with these data. We show that false-negative errors (failure to record a species when in fact it is present) can have a significant impact on statistical estimation of habitat models using simulated data. Then we introduce an extension of logistic modeling, the zero-inflated binomial (ZIB) model that permits the estimation of the rate of false-negative errors and the correction of estimates of the probability of occurrence for false-negative errors by using repeated. visits to the same site. Our simulations show that even relatively low rates of false negatives bias statistical estimates of habitat effects. The method with three repeated visits eliminates the bias, but estimates are relatively imprecise. Six repeated visits improve precision of estimates to levels comparable to that achieved with conventional statistics in the absence of false-negative errors In general, when error rates are less than or equal to50% greater efficiency is gained by adding more sites, whereas when error rates are >50% it is better to increase the number of repeated visits. We highlight the flexibility of the method with three case studies, clearly demonstrating the effect of false-negative errors for a range of commonly used survey methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Very few empirically validated interventions for improving metacognitive skills (i.e., self-awareness and self-regulation) and functional outcomes have been reported. This single-case experimental study presents JM, a 36-year-old man with a very severe traumatic brain injury (TBI) who demonstrated long-term awareness deficits. Treatment at four years post-injury involved a metacognitive contextual intervention based on a conceptualization of neuro-cognitive, psychological, and socio-environmental factors contributing to his awareness deficits. The 16-week intervention targeted error awareness and self-correction in two real life settings: (a) cooking at home: and (b) volunteer work. Outcome measures included behavioral observation of error behavior and standardized awareness measures. Relative to baseline performance in the cooking setting, JM demonstrated a 44% reduction in error frequency and increased self-correction. Although no spontaneous generalization was evident in the volunteer work setting, specific training in this environment led to a 39% decrease in errors. JM later gained paid employment and received brief metacognitive training in his work environment. JM's global self-knowledge of deficits assessed by self-report was unchanged after the program. Overall, the study provides preliminary support for a metacognitive contextual approach to improve error awareness and functional Outcome in real life settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Presbyopia is an age-related eye condition where one of the signs is the reduction in the amplitude of accommodation, resulting in the loss of ability to change the eye's focus from far to near. It is the most common age-related ailments affecting everyone around their mid-40s. Methods for the correction of presbyopia include contact lens and spectacle options but the surgical correction of presbyopia still remains a significant challenge for refractive surgeons. Surgical strategies for dealing with presbyopia may be extraocular (corneal or scleral) or intraocular (removal and replacement of the crystalline lens or some type of treatment on the crystalline lens itself). There are however a number of limitations and considerations that have limited the widespread acceptance of surgical correction of presbyopia. Each surgical strategy presents its own unique set of advantages and disadvantages. For example, lens removal and replacement with an intraocular lens may not be preferable in a young patient with presbyopia without a refractive error. Similarly treatment on the crystalline lens may not be a suitable choice for a patient with early signs of cataract. This article is a review of the options available and those that are in development stages and are likely to be available in the near future for the surgical correction of presbyopia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The Bonferroni correction adjusts probability (p) values because of the increased risk of a type I error when making multiple statistical tests. The routine use of this test has been criticised as deleterious to sound statistical judgment, testing the wrong hypothesis, and reducing the chance of a type I error but at the expense of a type II error; yet it remains popular in ophthalmic research. The purpose of this article was to survey the use of the Bonferroni correction in research articles published in three optometric journals, viz. Ophthalmic & Physiological Optics, Optometry & Vision Science, and Clinical & Experimental Optometry, and to provide advice to authors contemplating multiple testing. RECENT FINDINGS: Some authors ignored the problem of multiple testing while others used the method uncritically with no rationale or discussion. A variety of methods of correcting p values were employed, the Bonferroni method being the single most popular. Bonferroni was used in a variety of circumstances, most commonly to correct the experiment-wise error rate when using multiple 't' tests or as a post-hoc procedure to correct the family-wise error rate following analysis of variance (anova). Some studies quoted adjusted p values incorrectly or gave an erroneous rationale. SUMMARY: Whether or not to use the Bonferroni correction depends on the circumstances of the study. It should not be used routinely and should be considered if: (1) a single test of the 'universal null hypothesis' (Ho ) that all tests are not significant is required, (2) it is imperative to avoid a type I error, and (3) a large number of tests are carried out without preplanned hypotheses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For more than a century it has been known that the eye is not a perfect optical system, but rather a system that suffers from aberrations beyond conventional prescriptive descriptions of defocus and astigmatism. Whereas traditional refraction attempts to describe the error of the eye with only two parameters, namely sphere and cylinder, measurements of wavefront aberrations depict the optical error with many more parameters. What remains questionable is the impact these additional parameters have on visual function. Some authors have argued that higher-order aberrations have a considerable effect on visual function and in certain cases this effect is significant enough to induce amblyopia. This has been referred to as ‘higher-order aberration-associated amblyopia’. In such cases, correction of higher-order aberrations would not restore visual function. Others have reported that patients with binocular asymmetric aberrations display an associated unilateral decrease in visual acuity and, if the decline in acuity results from the aberrations alone, such subjects may have been erroneously diagnosed as amblyopes. In these cases, correction of higher-order aberrations would restore visual function. This refractive entity has been termed ‘aberropia’. In order to investigate these hypotheses, the distribution of higher-order aberrations in strabismic, anisometropic and idiopathic amblyopes, and in a group of visual normals, was analysed both before and after wavefront-guided laser refractive correction. The results show: (i) there is no significant asymmetry in higher-order aberrations between amblyopic and fixing eyes prior to laser refractive treatment; (ii) the mean magnitude of higher-order aberrations is similar within the amblyopic and visually normal populations; (iii) a significant improvement in visual acuity can be realised for adult amblyopic patients utilising wavefront-guided laser refractive surgery and a modest increase in contrast sensitivity was observed for the amblyopic eye of anisometropes following treatment (iv) an overall trend towards increased higher-order aberrations following wavefront-guided laser refractive treatment was observed for both visually normal and amblyopic eyes. In conclusion, while the data do not provide any direct evidence for the concepts of either ‘aberropia’ or ‘higher-order aberration-associated amblyopia’, it is clear that gains in visual acuity and contrast sensitivity may be realised following laser refractive treatment of the amblyopic adult eye. Possible mechanisms by which these gains are realised are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the relationship between pupil diameter and refractive error and how refractive correction, target luminance, and accommodation modulate this relationship. Methods: Sixty emmetropic, myopic, and hyperopic subjects (age range, 18 to 35 years) viewed an illuminated target (luminance: 10, 100, 200, 400, 1000, 2000, and 4100 cd/m2) within a Badal optical system, at 0 diopters (D) and −3 D vergence, with and without refractive correction. Refractive error was corrected using daily disposable contact lenses. Pupil diameter and accommodation were recorded continuously using a commercially available photorefractor. Results: No significant difference in pupil diameter was found between the refractive groups at 0 D or −3 D target vergence, in the corrected or uncorrected conditions. As expected, pupil diameter decreased with increasing luminance. Target vergence had no significant influence on pupil diameter. In the corrected condition, at 0 D target vergence, the accommodation response was similar in all refractive groups. At −3 D target vergence, the emmetropic and myopic groups accommodated significantly more than the hyperopic group at all luminance levels. There was no correlation between accommodation response and pupil diameter or refractive error in any refractive group. In the uncorrected condition, the accommodation response was significantly greater in the hyperopic group than in the myopic group at all luminance levels, particularly for near viewing. In the hyperopic group, the accommodation response was significantly correlated with refractive error but not pupil diameter. In the myopic group, accommodation response level was not correlated with refractive error or pupil diameter. Conclusions: Refractive error has no influence on pupil diameter, irrespective of refractive correction or accommodative demand. This suggests that the pupil is controlled by the pupillary light reflex and is not driven by retinal blur.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We recently published an article (García-Pérez & Alcalá- Quintana, 2010) reanalyzing data presented by Lapid, Ulrich, and Rammsayer (2008) and discussing a theoretical argument developed by Ulrich and Vorberg (2009). The purpose of this note is to correct an error in our study that has some theoretical importance, although it does not affect the conclusion that was raised. The error lies in that asymptote parameters reflecting lapses or finger errors should not enter the constraint relating the psychometric functions that describe performance when the comparison stimulus in a two-alternative forced choice (2AFC) discrimination task is presented in the first or second interval.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new method for the evaluation of the efficiency of parabolic trough collectors, called Rapid Test Method, is investigated at the Solar Institut Jülich. The basic concept is to carry out measurements under stagnation conditions. This allows a fast and inexpensive process due to the fact that no working fluid is required. With this approach, the temperature reached by the inner wall of the receiver is assumed to be the stagnation temperature and hence the average temperature inside the collector. This leads to a systematic error which can be rectified through the introduction of a correction factor. A model of the collector is simulated with COMSOL Multipyisics to study the size of the correction factor depending on collector geometry and working conditions. The resulting values are compared with experimental data obtained at a test rig at the Solar Institut Jülich. These results do not match with the simulated ones. Consequentially, it was not pos-sible to verify the model. The reliability of both the model with COMSOL Multiphysics and of the measurements are analysed. The influence of the correction factor on the rapid test method is also studied, as well as the possibility of neglecting it by measuring the receiver’s inner wall temperature where it receives the least amount of solar rays. The last two chapters analyse the specific heat capacity as a function of pressure and tem-perature and present some considerations about the uncertainties on the efficiency curve obtained with the Rapid Test Method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bangla OCR (Optical Character Recognition) is a long deserving software for Bengali community all over the world. Numerous e efforts suggest that due to the inherent complex nature of Bangla alphabet and its word formation process development of high fidelity OCR producing a reasonably acceptable output still remains a challenge. One possible way of improvement is by using post processing of OCR’s output; algorithms such as Edit Distance and the use of n-grams statistical information have been used to rectify misspelled words in language processing. This work presents the first known approach to use these algorithms to replace misrecognized words produced by Bangla OCR. The assessment is made on a set of fifty documents written in Bangla script and uses a dictionary of 541,167 words. The proposed correction model can correct several words lowering the recognition error rate by 2.87% and 3.18% for the character based n- gram and edit distance algorithms respectively. The developed system suggests a list of 5 (five) alternatives for a misspelled word. It is found that in 33.82% cases, the correct word is the topmost suggestion of 5 words list for n-gram algorithm while using Edit distance algorithm the first word in the suggestion properly matches 36.31% of the cases. This work will ignite rooms of thoughts for possible improvements in character recognition endeavour.