494 resultados para Endoprothèse (stent)
Resumo:
Mehrere kürzlich publizierte, prospektive, randomisierte Studien haben die Überlegenheit der mechanischen Thrombektomie mit Stent-Retrievern in Kombination mit intravenöser Thrombolyse gegenüber der alleinigen intravenösen Thrombolyse beim akuten ischämischen Hirnschlag auf dem Boden eines proximalen Hirngefässverschlusses bewiesen. Der folgende Artikel gibt eine Übersicht über die Entwicklung der endovaskulären Hirnschlagbehandlung mit Fokus auf die kürzlich erschienenen bahnbrechenden Studien.
Resumo:
An important competence of human data analysts is to interpret and explain the meaning of the results of data analysis to end-users. However, existing automatic solutions for intelligent data analysis provide limited help to interpret and communicate information to non-expert users. In this paper we present a general approach to generating explanatory descriptions about the meaning of quantitative sensor data. We propose a type of web application: a virtual newspaper with automatically generated news stories that describe the meaning of sensor data. This solution integrates a variety of techniques from intelligent data analysis into a web-based multimedia presentation system. We validated our approach in a real world problem and demonstrate its generality using data sets from several domains. Our experience shows that this solution can facilitate the use of sensor data by general users and, therefore, can increase the utility of sensor network infrastructures.
Resumo:
Facilitating general access to data from sensor networks (including traffic, hydrology and other domains) increases their utility. In this paper we argue that the journalistic metaphor can be effectively used to automatically generate multimedia presentations that help non-expert users analyze and understand sensor data. The journalistic layout and style are familiar to most users. Furthermore, the journalistic approach of ordering information from most general to most specific helps users obtain a high-level understanding while providing them the freedom to choose the depth of analysis to which they want to go. We describe the general characteristics and architectural requirements for an interactive intelligent user interface for exploring sensor data that uses the journalistic metaphor. We also describe our experience in developing this interface in real-world domains (e.g., hydrology).
Resumo:
Recently, we have presented some studies concerning the analysis, design and optimization of one experimental device developed in the UK - GPTAD - which has been designed to remove blood clots without the need to make contact with the clot itself, thereby potentially reducing the risk of problems such as downstream embolisation. Based on the idea of a modification of the previous device, in this work, we present a model based in the use of stents like the SolitaireTM FR, which is in contact with the clot itself. In the case of such devices, the stent is self-expandable and the extraction of the blood clot is faciliatated by the stent, which must be inside the clot. Such stents are generally inserted in position by using the guidewire inserted into the catheter. This type of modeling could potentially be useful in showing how the blood clot is moved by the various different forces involved. The modelling has been undertaken by analyzing the resistances, compliances and inertances effects. We model an artery and blood clot for range of forces for the guidewire. In each case we determine the interaction between blood clot, stent and artery.
Resumo:
In this article we describe a method for automatically generating text summaries of data corresponding to traces of spatial movement in geographical areas. The method can help humans to understand large data streams, such as the amounts of GPS data recorded by a variety of sensors in mobile phones, cars, etc. We describe the knowledge representations we designed for our method and the main components of our method for generating the summaries: a discourse planner, an abstraction module and a text generator. We also present evaluation results that show the ability of our method to generate certain types of geospatial and temporal descriptions.
Resumo:
Effective data summarization methods that use AI techniques can help humans understand large sets of data. In this paper, we describe a knowledge-based method for automatically generating summaries of geospatial and temporal data, i.e. data with geographical and temporal references. The method is useful for summarizing data streams, such as GPS traces and traffic information, that are becoming more prevalent with the increasing use of sensors in computing devices. The method presented here is an initial architecture for our ongoing research in this domain. In this paper we describe the data representations we have designed for our method, our implementations of components to perform data abstraction and natural language generation. We also discuss evaluation results that show the ability of our method to generate certain types of geospatial and temporal descriptions.
Resumo:
Modern sensor technologies and simulators applied to large and complex dynamic systems (such as road traffic networks, sets of river channels, etc.) produce large amounts of behavior data that are difficult for users to interpret and analyze. Software tools that generate presentations combining text and graphics can help users understand this data. In this paper we describe the results of our research on automatic multimedia presentation generation (including text, graphics, maps, images, etc.) for interactive exploration of behavior datasets. We designed a novel user interface that combines automatically generated text and graphical resources. We describe the general knowledge-based design of our presentation generation tool. We also present applications that we developed to validate the method, and a comparison with related work.
Resumo:
Las enfermedades arteriales vienen presididas por la aterosclerosis, que es un proceso crónico de degeneración, que evoluciona hacia la obstrucción de la luz arterial. La pared de la arteria se engrosa debido al depósito de elementos grasos tales como el colesterol. Los stents intraluminales son diminutas estructuras tubulares autoexpandibles de malla de metal, que se colocan dentro de la arteria coronaria después de una angioplastia con balón para prevenir el cierre de dicha arteria. A pesar de estar diseñados para ser compatibles con el tejido humano, a menudo se da una reacción en cadena de consecuencias indeseables. La reestenosis intra-stent es un problema creciente debido al importante incremento que se ha producido en la utilización del stent intracoronario como forma de revascularización percutánea. Se habla de una incidencia global del 28%, siendo la causa principal de su aparición la proliferación neointimal a través de una compleja cascada de sucesos que pueden tardar meses en desarrollarse. Una de las reacciones más importantes es la trombosis o la formación de una fina capa de coágulo como respuesta a la presencia de un material extraño. Este proceso es multifactorial, y en él intervienen la regresión de la pared como consecuencia del estiramiento previo, la denudación endotelial, lo que permite la agregación plaquetaria, la proliferación neointimal, lo que facilita a los receptores de membrana desencadenar un proceso de agregación posterior y, por último, el remodelado negativo inadecuado de la pared, lo que produce pérdida de luz arterial. Se ha observado frecuentemente que el depósito de ateroma en la pared arterial está relacionado con el valor de los esfuerzos cortantes en la misma. Hay mayores probabilidades de engrosamiento de la pared en las zonas donde son bajos los esfuerzos cortantes, quizá por el mayor tiempo de residencia de las partículas circulantes por el torrente sanguíneo. Si nos centramos en la afirmación anterior, el siguiente paso sería buscar las zonas susceptibles de presentar un valor bajo de dichos esfuerzos. Las zonas potencialmente peligrosas son los codos y bifurcaciones, entre otras. Nos hemos centrado en una bifurcación coronaria, ya que los patrones de flujo que se suelen presentar, tales como recirculación y desprendimiento de vórtices están íntimamente relacionados con las técnicas de implantación de stents en esta zona. Proyectamos nuestros esfuerzos en el estudio de dos técnicas de implante, utilizando un único stent y una tercera a través de una configuración de culotte con el uso de dos stents. El primer caso trata de una bifurcación con un único stent en la rama principal cuyos struts cierran el orificio lateral que da salida a la rama secundaria de la bifurcación, es decir sería un stent sin orificio. El segundo consiste en un único stent también, pero con la diferencia de que éste presenta un orificio de comunicación con la rama lateral. Todas estas técnicas se aplicaron a bifurcaciones de 45º y de 90º. Introdujimos las geometrías -una vez confeccionadas con el código comercial Gambit- en el programa Ansys-Fluent contemplando régimen estacionario. Los resultados obtenidos fueron cotejados con los experimentales, que se realizaron paralelamente, con el fin de corroborarlos. Una vez validados, el estudio computacional ya contó con la fiabilidad suficiente como para abordar el régimen no estacionario, tanto en la versión de reposo como en la de ejercicio –hiperemia- El comportamiento reológico de la sangre para régimen no estacionario en estado de reposo es otra de las tareas abordadas, realizando una comparativa de los modelos Newtoniano, Carreau y Ley de Potencias. Finalmente, en una última etapa, debido a la reciente incursión de los stents diseñados específicamente frente a los convencionales, se aborda el comportamiento hemodinámico de los mismos. Concretamente, se comparó el patrón de flujo en un modelo de bifurcación coronaria con los nuevos stents (Stentys) y los convencionales. Se estudiaron cuatro modelos, a saber, stent simple en la rama principal, stent simple en la rama secundaria, culotte desplegando el primer stent en la rama principal y culotte desplegando el primer stent en la rama secundaria. La bifurcación estudiada presenta un ángulo de apertura de 45º y la relación de diámetros de las ramas hija se ajustaron de acuerdo a la ley de Finet. Se recogieron resultados experimentales en el laboratorio y se corrieron simulaciones numéricas con Ansys Fluent paralelamente. Las magnitudes que se tuvieron en cuenta con el fin de ubicar las regiones potencialmente ateroscleróticas fueron los esfuerzos cortantes, vorticidad y caída de presión. ABSTRACT Nowadays, restenosis after percutaneous dilation is the major drawback of coronary angioplasty. It represents a special form of atherosclerosis due to the healing process secondary to extensive vessel trauma induced after intracoronary balloon inflation. The use of coronary stents may decrease the incidence of this phenomenon. Unfortunately, intra-stent restenosis still occurs in 20-30% of the cases following the stent implantation. Most experiments suggest a correlation between low wall shear stress and wall thickness. The preferential locations for the atherosclerotic plaque are bifurcations. The objective of this work is to analyze the local hemodynamic changes caused in a coronary bifurcation by three different stenting techniques: simple stenting of the main vessel, simple stenting of the main vessel with kissing balloon in the side branch and culotte. To carry out this study an idealized geometry of a coronary bifurcation is used, and two bifurcation angles, 45º and 90º, are chosen as representative of the wide variety of real configurations. Both numerical simulations and experimental measurements are performed. First, steady simulations are carried out with the commercial code Ansys-Fluent, then, experimental measurements with PIV (Particle Image Velocimetry), obtained in the laboratory, are used to validate the numerical simulations. The steady computational simulations show a good overall agreement with the experimental data. Then, pulsatile flow is considered to take into account the transient effects. The time averaged wall shear stress, oscillatory shear index and pressure drop obtained numerically are used to compare the behavior of the stenting techniques. In a second step, the rheologic behavior of blood was considered comparing Newtonian, Carreau and Power Law models. Finally, as a result of previous investigations with conventional stents and after the recent emergence of several devices specifically designed for coronary bifurcations angioplasty, the hemodynamic performance of these new devices (Stentys) was compared to conventional ones and techniques in a coronary bifurcation model. Four different stenting techniques: simple stenting of the main vessel, simple stenting of the side vessel, culotte deploying the first stent in the main vessel and culotte deploying the first stent in the side vessel have been considered. To carry out this study an idealized geometry of a coronary bifurcation is used. A 45 degrees bifurcation angle is considered and the daughter branches diameters are obtained according to the Finet law. Both experiments in the laboratory and numerical simulations were used , focusing on important factors for the atherosclerosis development, like the wall shear stress, the oscillation shear index, the pressure loss and the vorticity.
Resumo:
INTRODUÇÃO: A prótese biliar endoscópica é aceita em todo o mundo como a primeira escolha de tratamento paliativo na obstrução biliar maligna. Atualmente ainda persistem dois tipos de materiais utilizados em sua confecção: plástico e metal. Consequentemente, muitas dúvidas surgem quanto a qual deles é o mais benéfico para o paciente. Esta revisão reúne as informações disponíveis da mais alta qualidade sobre estes dois tipos de prótese, fornecendo informações em relação à disfunção, complicação, taxas de reintervenção, custos, sobrevida e tempo de permeabilidade; e pretende ajudar a lidar com a prática clínica nos dias de hoje. OBJETIVO: Analisar, através de metanálise, os benefícios de dois tipos de próteses na obstrução biliar maligna inoperável. MÉTODOS: Uma revisão sistemática de ensaios clínicos randomizados (RCT) foi conduzida, com a última atualização em março de 2015, utilizando EMBASE, CINAHL (EBSCO), Medline, Lilacs / Centro (BVS), Scopus, o CAPES (Brasil), e literatura cinzenta. As informações dos estudos selecionados foram extraídas tendo em vista seis desfechos: primariamente disfunção, taxas de reintervenção e complicações; e, secundariamente, custos, sobrevivência e tempo de permeabilidade. Os dados sobre as características dos participantes do RCT, critérios de inclusão e exclusão e tipos de próteses também foram extraídos. Os vieses foram avaliados principalmente através da escala de Jadad. Esta metanálise foi registrada no banco de dados PROSPERO pelo número CRD42014015078. A análise do risco absoluto dos resultados foi realizada utilizando o software RevMan 5, calculando as diferenças de risco (RD) de variáveis dicotômicas e média das diferenças (MD) de variáveis contínuas. Os dados sobre a RD e MD para cada desfecho primário foram calculados utilizando o teste de Mantel-Haenszel e a inconsistência foi avaliada com o teste Qui-quadrado (Chi2) e o método de Higgins (I2). A análise de sensibilidade foi realizada com a retirada de estudos discrepantes e a utilização do efeito aleatório. O teste t de Student foi utilizado para a comparação das médias aritméticas ponderadas, em relação aos desfechos secundários. RESULTADOS: Inicialmente foram identificados 3660 estudos; 3539 foram excluídos por título ou resumo, enquanto 121 estudos foram totalmente avaliados e foram excluídos, principalmente por não comparar próteses metálicas (SEMS) e próteses plásticas (PS), levando a treze RCT selecionados e 1133 indivíduos metanálise. A média de idade foi de 69,5 anos, e o câncer mais comum foi de via biliar (proximal) e pancreático (distal). O diâmetro de SEMS mais utilizado foi de 10 mm (30 Fr) e o diâmetro de PS mais utilizado foi de 10 Fr. Na metanálise, SEMS tiveram menor disfunção global em comparação com PS (21,6% versus 46,8% p < 0,00001) e menos reintervenções (21,6% versus 56,6% p < 0,00001), sem diferença nas complicações (13,7% versus 15,9% p = 0,16). Na análise secundária, a taxa média de sobrevida foi maior no grupo SEMS (182 contra 150 dias - p < 0,0001), com um período maior de permeabilidade (250 contra 124 dias - p < 0,0001) e um custo semelhante por paciente, embora menor no grupo SEMS (4.193,98 contra 4.728,65 Euros - p < 0,0985). CONCLUSÃO: SEMS estão associados com menor disfunção, menores taxas de reintervenção, melhor sobrevida e maior tempo de permeabilidade. Complicações e custos não apresentaram diferença
Resumo:
Les artéfacts métalliques entraînent un épaississement artéfactuel de la paroi des tuteurs en tomodensitométrie (TDM) avec réduction apparente de leur lumière. Cette étude transversale prospective, devis mesures répétées et observateurs avec méthode en aveugle, chez 24 patients consécutifs/71 tuteurs coronariens a pour objectif de comparer l’épaisseur de paroi des tuteurs en TDM après reconstruction par un algorithme avec renforcement des bords et un algorithme standard. Une angiographie coronarienne par TDM 256 coupes a été réalisée, avec reconstruction par algorithmes avec renforcement des bords et standard. L’épaisseur de paroi des tuteurs était mesurée par méthodes orthogonale (diamètres) et circonférentielle (circonférences). La qualité d’image des tuteurs était évaluée par échelle ordinale, et les données analysées par modèles linéaire mixte et régression logistique des cotes proportionnelles. L’épaisseur de paroi des tuteurs était inférieure avec l’algorithme avec renforcement des bords comparé à l’algorithme standard, avec les méthodes orthogonale (0,97±0,02 vs 1,09±0,03 mm, respectivement; p<0,001) et circonférentielle (1,13±0,02 vs 1,21±0,02 mm, respectivement; p<0,001). Le premier causait moins de surestimation par rapport à l’épaisseur nominale comparé au second, avec méthodes orthogonale (0,89±0,19 vs 1,00±0,26 mm, respectivement; p<0,001) et circonférentielle (1,06±0,26 vs 1,13±0,31 mm, respectivement; p=0,005) et diminuait de 6 % la surestimation. Les scores de qualité étaient meilleurs avec l’algorithme avec renforcement des bords (OR 3,71; IC 95% 2,33–5,92; p<0,001). En conclusion, la reconstruction des images avec l’algorithme avec renforcement des bords génère des parois de tuteurs plus minces, moins de surestimation, et de meilleurs scores de qualité d’image que l’algorithme standard.
Resumo:
A terapêutica antitrombótica ocupa um lugar central no tratamento da doença coronária aguda. A sua importância foi reforçada com a generalização dos procedimentos de intervenção percutânea, em especial quando são implantados dispositivos intra-coronários. Neste domínio, o uso da dupla antiagregação plaquetar é obrigatório, combinando a clássica aspirina às tienopiridinas, em particular ao clopidogrel. Em paralelo, o uso de anticoagulantes é igualmente mandatório, particularmente nas primeiras horas, até à angioplastia e implantação de stent. Depois de uma década dominada pelo clopidogrel e pela enoxaparina, assistimos, recentemente, à introdução de novos fármacos, em especial o fondaparinux e mais recentemente o prasugrel, ambos com as suas vantagens e desvantagens. O Congresso Europeu de Cardiologia 2009 foi particularmente rico nesta área, já que três importantes estudos viram os seus resultados apresentados, todos eles com relevantes implicações para a prática clínica. O estudo PLATO introduzindo o ticagrelor,primeiro antiplaquetar actuando via receptor P2Y12 com efeito reversível; o estudo CURRENT-OASIS 7 testando doses, acima do convencional, de clopidogrel e aspirina; o estudo SEPIA-ACS 1 TIMI 42 introduzindo o otamixaban, novo anticoagulante com efeito anti-Xa administrado por via intra-venosa; são, no presente trabalho, sumariamente apresentados e discutidos, procurando realçar alguns aspectos que poderão vir a introduzir alterações nas recomendações e consequentemente na prática do dia a dia.
Resumo:
OBJECTIVE Type A aortic dissection is a life-threatening disease requiring immediate surgical treatment. With emerging catheter-based technologies, endovascular stent-graft implantation to treat aneurysms and dissections has become a standardized procedure. However, endovascular treatment of the ascending aorta remains challenging. Thus we designed an ascending aortic dissection model to allow simulation of endovascular treatment. METHODS Five formalin-fixed human aortas were prepared. The ascending aorta was opened semicircularly in the middle portion and the medial layer was separated from the intima. The intimal tube was readapted using running monofilament sutures. The preparations were assessed by 128-slice computed tomography. A bare-metal stent was implanted for thoracic endovascular aortic repair in 4 of the aortic dissection models. RESULTS Separation of the intimal and medial layer of the aorta was considered to be sufficient because computed tomography showed a clear image of the dissection membrane in each aorta. The dissection was located 3.9 ± 1.4 cm proximally from the aortic annulus, with a length of 4.6 ± 0.9 cm. Before stent implantation, the mean distance from the intimal flap to the aortic wall was measured as 0.63 ± 0.163 cm in the ascending aorta. After stent implantation, this distance decreased to 0.26 ± 0.12 cm. CONCLUSION This model of aortic dissection of the ascending human aorta was reproducible with a comparable pathological and morphological appearance. The technique and model can be used to evaluate new stent-graft technologies to treat type A dissection and facilitate training for surgeons.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
Bibliography: p. 429-465.
Resumo:
"Published by order of the Inspector General of Customs."