994 resultados para Emission Source
Resumo:
AbstractFor a wide range of environmental, hydrological, and engineering applications there is a fast growing need for high-resolution imaging. In this context, waveform tomographic imaging of crosshole georadar data is a powerful method able to provide images of pertinent electrical properties in near-surface environments with unprecedented spatial resolution. In contrast, conventional ray-based tomographic methods, which consider only a very limited part of the recorded signal (first-arrival traveltimes and maximum first-cycle amplitudes), suffer from inherent limitations in resolution and may prove to be inadequate in complex environments. For a typical crosshole georadar survey the potential improvement in resolution when using waveform-based approaches instead of ray-based approaches is in the range of one order-of- magnitude. Moreover, the spatial resolution of waveform-based inversions is comparable to that of common logging methods. While in exploration seismology waveform tomographic imaging has become well established over the past two decades, it is comparably still underdeveloped in the georadar domain despite corresponding needs. Recently, different groups have presented finite-difference time-domain waveform inversion schemes for crosshole georadar data, which are adaptations and extensions of Tarantola's seminal nonlinear generalized least-squares approach developed for the seismic case. First applications of these new crosshole georadar waveform inversion schemes on synthetic and field data have shown promising results. However, there is little known about the limits and performance of such schemes in complex environments. To this end, the general motivation of my thesis is the evaluation of the robustness and limitations of waveform inversion algorithms for crosshole georadar data in order to apply such schemes to a wide range of real world problems.One crucial issue to making applicable and effective any waveform scheme to real-world crosshole georadar problems is the accurate estimation of the source wavelet, which is unknown in reality. Waveform inversion schemes for crosshole georadar data require forward simulations of the wavefield in order to iteratively solve the inverse problem. Therefore, accurate knowledge of the source wavelet is critically important for successful application of such schemes. Relatively small differences in the estimated source wavelet shape can lead to large differences in the resulting tomograms. In the first part of my thesis, I explore the viability and robustness of a relatively simple iterative deconvolution technique that incorporates the estimation of the source wavelet into the waveform inversion procedure rather than adding additional model parameters into the inversion problem. Extensive tests indicate that this source wavelet estimation technique is simple yet effective, and is able to provide remarkably accurate and robust estimates of the source wavelet in the presence of strong heterogeneity in both the dielectric permittivity and electrical conductivity as well as significant ambient noise in the recorded data. Furthermore, our tests also indicate that the approach is insensitive to the phase characteristics of the starting wavelet, which is not the case when directly incorporating the wavelet estimation into the inverse problem.Another critical issue with crosshole georadar waveform inversion schemes which clearly needs to be investigated is the consequence of the common assumption of frequency- independent electromagnetic constitutive parameters. This is crucial since in reality, these parameters are known to be frequency-dependent and complex and thus recorded georadar data may show significant dispersive behaviour. In particular, in the presence of water, there is a wide body of evidence showing that the dielectric permittivity can be significantly frequency dependent over the GPR frequency range, due to a variety of relaxation processes. The second part of my thesis is therefore dedicated to the evaluation of the reconstruction limits of a non-dispersive crosshole georadar waveform inversion scheme in the presence of varying degrees of dielectric dispersion. I show that the inversion algorithm, combined with the iterative deconvolution-based source wavelet estimation procedure that is partially able to account for the frequency-dependent effects through an "effective" wavelet, performs remarkably well in weakly to moderately dispersive environments and has the ability to provide adequate tomographic reconstructions.
Resumo:
PURPOSE: 3'-deoxy-3'-[(18)F]fluorothymidine ([(18)F]FLT), a cell proliferation positron emission tomography (PET) tracer, has been shown in numerous tumors to be more specific than 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) but less sensitive. We studied the capacity of a nontoxic concentration of 5-fluoro-2'-deoxyuridine (FdUrd), a thymidine synthesis inhibitor, to increase uptake of [(18)F]FLT in tumor xenografts. METHODS: The duration of the FdUrd effect in vivo on tumor cell cycling and thymidine analogue uptake was studied by varying FdUrd pretreatment timing and holding constant the timing of subsequent flow cytometry and 5-[(125)I]iodo-2'-deoxyuridine biodistribution measurements. In [(18)F]FLT studies, FdUrd pretreatment was generally performed 1 h before radiotracer injection. [(18)F]FLT biodistributions were measured 1 to 3 h after radiotracer injection of mice grafted with five different human tumors and pretreated or not with FdUrd and compared with [(18)F]FDG tumor uptake. Using microPET, the dynamic distribution of [(18)F]FLT was followed for 1.5 h in FdUrd pretreated mice. High-field T2-weighted magnetic resonance imaging (MRI) and histology were used comparatively in assessing tumor viability and proliferation. RESULTS: FdUrd induced an immediate increase in tumor uptake of 5-[(125)I]iodo-2'-deoxyuridine, that vanished after 6 h, as also confirmed by flow cytometry. Biodistribution measurements showed that FdUrd pretreatment increased [(18)F]FLT uptake in all tumors by factors of 3.2 to 7.8 compared with controls, while [(18)F]FDG tumor uptake was about fourfold and sixfold lower in breast cancers and lymphoma. Dynamic PET in FdUrd pretreated mice showed that [(18)F]FLT uptake in all tumors increased steadily up to 1.5 h. MRI showed a well-vascularized homogenous lymphoma with high [(18)F]FLT uptake, while in breast cancer, a central necrosis shown by MRI was inactive in PET, consistent with the histomorphological analysis. CONCLUSION: We showed a reliable and significant uptake increase of [(18)F]FLT in different tumor xenografts after low-dose FdUrd pretreatment. These results show promise for a clinical application of FdUrd aimed at increasing the sensitivity of [(18)F]FLT PET.
Resumo:
PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine.
Resumo:
PURPOSE: The aim of this study was to conduct a systematic review and perform a meta-analysis on the diagnostic performances of (18)F-fluorodeoxyglucose positron emission tomography (FDG PET) for giant cell arteritis (GCA), with or without polymyalgia rheumatica (PMR). METHODS: MEDLINE, Embase and the Cochrane Library were searched for articles in English that evaluated FDG PET in GCA or PMR. All complete studies were reviewed and qualitatively analysed. Studies that fulfilled the three following criteria were included in a meta-analysis: (1) FDG PET used as a diagnostic tool for GCA and PMR; (2) American College of Rheumatology and Healey criteria used as the reference standard for the diagnosis of GCA and PMR, respectively; and (3) the use of a control group. RESULTS: We found 14 complete articles. A smooth linear or long segmental pattern of FDG uptake in the aorta and its main branches seems to be a characteristic pattern of GCA. Vessel uptake that was superior to liver uptake was considered an efficient marker for vasculitis. The meta-analysis of six selected studies (101 vasculitis and 182 controls) provided the following results: sensitivity 0.80 [95% confidence interval (CI) 0.63-0.91], specificity 0.89 (95% CI 0.78-0.94), positive predictive value 0.85 (95% CI 0.62-0.95), negative predictive value 0.88 (95% CI 0.72-0.95), positive likelihood ratio 6.73 (95% CI 3.55-12.77), negative likelihood ratio 0.25 (95% CI 0.13-0.46) and accuracy 0.84 (95% CI 0.76-0.90). CONCLUSION: We found overall valuable diagnostic performances for FDG PET against reference criteria. Standardized FDG uptake criteria are needed to optimize these diagnostic performances.
Resumo:
El tema de este estudio es el aumento de la comprensión teórica y empírica de la estrategia de negocio de código abierto en el dominio de sistemas embebidos por investigar modelos de negocios de código abierto, retos, recursos y capacidades operativas y dinámicas.
Resumo:
Radioimmunodetection of tumours with monoclonal antibodies is becoming an established procedure. Positron emission tomography (PET) shows better resolution than normal gamma camera single photon emission tomography and can provide more precise quantitative data. Thus, in the present study, these powerful methods have been combined to perform radioimmuno PET (RI-PET). Monoclonal antibodies directed against carcinoembryonic antigen (CEA) an IgG, its F(ab')2 and a mouse-human chimeric IgG derived from it were labelled with 124I, a positron-emitting radionuclide with a convenient physical half-life of four days. Mice, xenografted with a CEA-producing human colon carcinoma, were injected with the 124I-MAb and the tumours were visualized using PET. The concentrations of 124I in tumour and normal tissue were determined by both PET and direct radioactivity counting of the dissected animals, with very good agreement. To allow PET quantification, a procedure was established to account for the presence of radioactivity during the absorption correction measurement (transmission scan). Comparison of PET and tissue counting indicates that this novel combination of radioimmunolocalization and PET (RI-PET) will provide, in addition to more precise diagnosis, more accurate radiation dosimetry for radioimmunotherapy.
Resumo:
The diagnosis of focal status epilepticus (SE) can be challenging, particularly when clinical manifestations leave doubts about its nature, and electroencephalography (EEG) is not conclusive. This work addresses the utility of ictal (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) in focal SE, which was performed in eight patients in whom SE was finally diagnosed. Clinical, MRI and EEG data were reviewed. (18)F-FDG-PET proved useful: (1) to establish the diagnosis of focal SE, when clinical elements were equivocal or the EEG did not show clear-cut epileptiform abnormalities; (2) to delineate the epileptogenic area in view of possible resective surgery; and (3) when clinical features, MRI and EEG were incongruent regarding the origin of SE. We suggest that ictal (18)F-FDG-PET may represent a valuable diagnostic tool in selected patients with focal SE or frequent focal seizures.
Resumo:
A gestão de infra-estruturas é um processo de coordenação, avaliação sistemática e manutenção efectiva das infra-estruturas relacionadas com os serviços básicos. A gestão eficaz de infra-estruturas exige que a disposição dos equipamentos no meio urbano seja conhecida, bem como sua relação com o uso do solo. Sendo a gestão de infra-estruturas uma questão de natureza espacial, é natural pensar na utilização de um Sistema de Informação Geográfica como ferramenta com potencial de grande utilidade, pois permite a georreferenciação de dados espaciais e sua interligação com atributos alfanuméricos, para além da realização de análises complexas e a possibilidade de simular diversos cenários de modo a propiciar uma tomada de decisão eficaz. O elevado custo das licenças e a especificidade de utilização a nível técnico, tornam-se obstáculos na criação e manutenção de dados geográficos. Contudo os recentes desenvolvimentos em tecnologias da Internet têm contribuído para o acesso, publicação, exploração e distribuição da Informação Geográfica. A utilização de SIG distribuídos na Internet (WebGIS), nomeadamente na vertente livre, pode ser uma solução adequada visto que coloca funcionalidades de SIG ao alcance de utilizadores, através de um simples browser, sem necessidade de investimentos em relação a software ou mesmo em formação técnica especializada. Assim, com este projecto pretende-se a criação de um sistema de Informação geográfico na Internet, utilizando softwares livres, que disponibiliza toda a informação geográfica e alfanumérica das infra-estruturas construídas e sob a responsabilidade do Ministério das Infra-estruturas e Economia Marítima, permitindo a visualização e a realização de pesquisas e operações de análise.
Resumo:
Water fact sheet for Iowa Department of Natural Resources and the Geological Bureau.