967 resultados para Dynamic Contrast Enhanced Magnetic Resonance Imaging
Resumo:
Disc herniation with posterior epidural migration is a rare and often symptomatic entity. Multiple are the natural barriers that prevent this pattern of migration. Enhanced magnetic resonance imaging is the diagnostic modality of choice in these cases. The diagnostic dilemma in this case was the contraindication to the use of contrast since the patient was known to have chronic renal failure.
Resumo:
Entailing of phosphorus exchanges in most bio-chemicals as a key factor in disease, increases researcher’s interest to develop the technologies capable of detecting this metabolite. Phosphorus magnetic resonance spectroscopy is able to detect key metabolites in a non-invasive manner. Particularly, it offers the ability to measure the dynamic rate of phosphocreatine(PCr) degeneration through the exercise and recovery. This metric as a valid indication of mitochondrial oxidative metabolism in muscle, differentiate between normal and pathological state. To do magnetic resonance imaging and spectroscopy, clinical research tools provide a wide variety of anatomical and functional contrasts, however they are typically restricted to the tissues containing water or hydrogen atoms and they are still blind to the biochemicals of other atoms of interests. Through this project we intended to obtain the phosphorus spectrum in human body – specificadenerativelly in muscle – using 31P spectroscopy. To do so a double loop RF surface coil, tuned to phosphorus frequency, is designed and fabricated using bench work facilities and then validated through in vitro spectroscopy using 3 Tesla Siemens scanner. We acquired in vitro as well as in vivo phosphorus spectrum in a 100 mM potassium phosphate phantom and human calf muscle in rest-exercise-recovery phase in a 3T MR scanner. The spectrum demonstrates the main constituent in high-energy phosphate metabolism. We also observed the dynamic variation of PCr for five young healthy subjects who performed planter flexions using resistance band during exercise and recovery. The took steps in this project pave the way for future application of spectroscopic quantification of phosphate metabolism in patients affected by carotid artery disease as well as in age-matched control subjects.
Resumo:
A major challenge in imaging is the detection of small amounts of molecules of interest. In the case of magnetic resonance imaging (MRI) their signals are typically concealed by the large background signal of e.g. the tissue of the body. This problem can be tackled by hyperpolarization which increases the NMR signals up to several orders of magnitude. However, this strategy is limited for 1H, the most widely used nucleus in NMR andrnMRI, because the enormous number of protons in the body screen the small amount of hyperpolarized ones.Here, I describe a method giving rise to high 1H MRI contrast for hyperpolarized molecules against a large background signal. The contrast is based on the J-coupling induced rephasing of the NMR signal of molecules hyperpolarized via parahydrogen induce polarization (PHIP) and it can easily be implemented in common pulse sequences.rnrnHyperpolarization methods typically require expensive technical equipment (e.g. lasers or microwaves) and most techniques work only in batch mode, thus the limited lifetime of the hyperpolarization is limiting its applications. Therefore, the second part of my thesis deals with the simple and efficient generation of an hyperpolarization.These two achievements open up alternative opportunities to use the standard MRI nucleus 1H for e.g. metabolic imaging in the future.
Resumo:
Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebrovascular diseases, e.g., aneurysm and arteriovenous malformations. However, subtle microvascular disease usually cannot be resolved with standard, clinical-field-strength MRA. The purpose of this study was to compare the ability of ToF and PC MRA to visualize the cerebral arteries at increasing field strengths.
Resumo:
PURPOSE: To compare diagnostic accuracy of multi-station, high-spatial resolution contrast-enhanced MR angiography (CE-MRA) of the lower extremities with digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial occlusive disease. MATERIALS AND METHODS: Of 485 consecutive patients undergoing a run-off CE-MRA, 152 patients (86 male, 66 female; mean age, 71.6 years) with suspected peripheral arterial occlusive disease were included into our Institutional Review Board approved study. All patients underwent MRA and DSA of the lower extremities within 30 days. MRA was performed at 1.5 Tesla with a single bolus of 0.1 mmol/kg body weight of gadobutrol administered at a rate of 2.0 mL/s at three stations. Two readers evaluated the MRA images independently for stenosis grade and image quality. Sensitivity and specificity were derived. RESULTS: Sensitivity and specificity ranged from 73% to 93% and 64% to 89% and were highest in the thigh area. Both readers showed comparable results. Evaluation of good and better quality MRAs resulted in a considerable improvement in diagnostic accuracy. CONCLUSION: Contrast-enhanced MRA demonstrates good sensitivity and specificity in the investigation of the vasculature of the lower extremities. While a minor investigator experience dependence remains, it is standardizable and shows good inter-observer agreement. Our results confirm that the administration of Gadobutrol at a standard dose of 0.1 mmol/kg for contrast-enhanced runoff MRA is able to detect hemodynamically relevant stenoses. Use of contrast-enhanced MRA as an alternative to intra-arterial DSA in the evaluation and therapeutic planning of patients with suspected peripheral arterial occlusive disease is well justified. J. Magn. Reson. Imaging 2013;37:1427-1435. © 2012 Wiley Periodicals, Inc.
Resumo:
BACKGROUND The diagnostic value of a contrast-enhanced T2-weighted FLAIR sequence (ceFLAIR) in brain imaging is unclear. HYPOTHESIS/OBJECTIVES That the number of brain lesions detected with ceFLAIR would be no greater than the sum of lesions detected with nFLAIR and ceT1W sequence. ANIMALS One hundred and twenty-nine animals (108 dogs and 21 cats) undergoing magnetic resonance imaging (MRI) of the head between July 2010 and October 2011 were included in the study. METHODS A transverse ceFLAIR was added to a standard brain MRI protocol. Presence and number of lesions were determined based on all available MRI sequences by 3 examiners in consensus and lesion visibility was evaluated for nFLAIR, ceFLAIR, and ceT1W sequences. RESULTS Eighty-three lesions (58 intra-axial and 25 extra-axial) were identified in 51 patients. Five lesions were detected with nFLAIR alone, 2 with ceT1W alone, and 1 with ceFLAIR alone. Significantly higher numbers of lesions were detected using ceFLAIR than nFLAIR (76 versus 67 lesions; P = 0.04), in particular for lesions also detected with ceT1W images (53 versus 40; P =.01). There was no significant difference between the number of lesions detected with combined nFLAIR and ceT1W sequences compared to those detected with ceFLAIR (82 versus 76; P =.25). CONCLUSION AND CLINICAL IMPORTANCE Use of ceFLAIR as a complementary sequence to nFLAIR and ceT1W sequences did not improve the detection of brain lesions and cannot be recommended as part of a routine brain MRI protocol in dogs and cats with suspected brain lesions.
Resumo:
PURPOSE Assessment of the cerebral blood flow (CBF) is crucial in the evaluation of patients with steno-occlusive diseases of the arteries supplying the brain for prediction of stroke risk. Quantitative phase contrast magnetic resonance angiography (PC-MRA) can be utilised for noninvasive quantification of CBF. The aim of this study was to validate in-vivo PC-MRA data by comparing them with colour-coded duplex (CCD) sonography in patients with cerebrovascular disease. METHODS AND MATERIALS We examined 24 consecutive patients (mean age 63 years) with stenosis of arteries supplying the brain using PC-MRA and CCD. Velocities were measured in a total of 209 stenotic and healthy arterial segments (110 extra- and 99 intracranial). RESULTS Moderate to good correlation of velocity measurements between both techniques was observed in all six extracranial and five out of seven intracranial segments (p <0.05). Velocities measured with CCD sonography were generally higher than those obtained by PC-MRA. Reversal of flow direction was detected consistently with both methods. CONCLUSION PC-MRA represents a robust, standardised magnetic resonance imaging technique for blood flow measurements within a reasonable acquisition time, potentially evolving as valuable work-up tool for more precise patient stratification for revascularisation therapy. PC-MRA overcomes relevant weaknesses of CCD in being not operator-dependent and not relying on a bone window to assess the intracranial arteries.
Resumo:
The first and second authors would like to thank the support of the PhD grants with references SFRH/BD/28817/2006 and SFRH/PROTEC/49517/2009, respectively, from Fundação para a Ciência e Tecnol ogia (FCT). This work was partially done in the scope of the project “Methodologies to Analyze Organs from Complex Medical Images – Applications to Fema le Pelvic Cavity”, wi th reference PTDC/EEA- CRO/103320/2008, financially supported by FCT.
Resumo:
PURPOSE: To assess the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography of the wrist with regard to joint space width and amount of contrast material between the opposing cartilage surfaces. MATERIALS AND METHODS: Fifteen consecutive patients (12 male, mean age 38.1 years) were included in this Institutional Review Board-approved prospective study. Three-compartment wrist MR arthrographies were performed between October and December 2009 on a 3 T unit using a fat-suppressed T1-weighted isotropic high-resolution volumetric interpolated breathhold examination (VIBE) sequence in the coronal plane, with and without axial traction (3 kg). Two radiologists measured radiocarpal (radioscaphoid, radiolunate) and midcarpal (lunocapitate, hamatolunate) joint space widths, with and without traction, and assessed the amount of contrast material between the opposing cartilage surfaces using a three-point scale: 0 = absence, 1 = partial, 2 = complete. RESULTS: With traction, joint space width increased significantly at the radioscaphoid (Delta = 0.78 mm, P < 0.01), radiolunate (Delta = 0.18 mm, P < 0.01), and lunocapitate (Delta = 0.45 mm, P < 0.01) spaces, and both observers detected significantly more contrast material between the cartilage surfaces. At the hamatolunate space, the differences in joint space width (Delta = 0.14 mm, P = 0.54) and amount of contrast material were not significant. CONCLUSION: Direct wrist MR arthrography with axial traction of 3 kg increases joint space width at the radiocarpal and lunocapitate spaces, and prompts better coverage of the articular cartilage by the contrast material. J. Magn. Reson. Imaging 2011;. (c) 2011 Wiley-Liss, Inc.
Resumo:
In type I diabetes mellitus, islet transplantation provides a moment-to-moment fine regulation of insulin. Success rates vary widely, however, necessitating suitable methods to monitor islet delivery, engraftment and survival. Here magnetic resonance-trackable magnetocapsules have been used simultaneously to immunoprotect pancreatic beta-cells and to monitor, non-invasively in real-time, hepatic delivery and engraftment by magnetic resonance imaging (MRI). Magnetocapsules were detected as single capsules with an altered magnetic resonance appearance on capsule rupture. Magnetocapsules were functional in vivo because mouse beta-cells restored normal glycemia in streptozotocin-induced diabetic mice and human islets induced sustained C-peptide levels in swine. In this large-animal model, magnetocapsules could be precisely targeted for infusion by using magnetic resonance fluoroscopy, whereas MRI facilitated monitoring of liver engraftment over time. These findings are directly applicable to ongoing improvements in islet cell transplantation for human diabetes, particularly because our magnetocapsules comprise clinically applicable materials.
Resumo:
Cardiovascular magnetic resonance (CMR) is a rapidly emerging non-invasive imaging technique free of X-Ray and offers higher spatial resolution than alternative forms of cardiac imaging for the assessment of left ventricular (LV) anatomy, function, and viability due to the unique capability of myocardial tissue characterization after gadolinium-chelates contrast administration. This imaging technique has clinical utility over a broad spectrum of heart diseases: ranging from ischaemic to non ischaemic aetiologies. Cardiomyopathies (CMP) are a heterogeneous group of diseases of the myocardium associated with architectural abnormalities and mechanical dysfunction. CMR can help excluding coronary artery disease and can provide positive diagnostic features for several CMP resulted in better diagnosis and management, Leading to improvements in mortality.
Resumo:
BACKGROUND: We sought to investigate the relationship between infarct and dyssynchrony post- myocardial infarct (MI), in a porcine model. Mechanical dyssynchrony post-MI is associated with left ventricular (LV) remodeling and increased mortality. METHODS: Cine, gadolinium-contrast, and tagged cardiovascular magnetic resonance (CMR) were performed pre-MI, 9 ± 2 days (early post-MI), and 33 ± 10 days (late post-MI) post-MI in 6 pigs to characterize cardiac morphology, location and extent of MI, and regional mechanics. LV mechanics were assessed by circumferential strain (eC). Electro-anatomic mapping (EAM) was performed within 24 hrs of CMR and prior to sacrifice. RESULTS: Mean infarct size was 21 ± 4% of LV volume with evidence of post-MI remodeling. Global eC significantly decreased post MI (-27 ± 1.6% vs. -18 ± 2.5% (early) and -17 ± 2.7% (late), p < 0.0001) with no significant change in peri-MI and MI segments between early and late time-points. Time to peak strain (TTP) was significantly longer in MI, compared to normal and peri-MI segments, both early (440 ± 40 ms vs. 329 ± 40 ms and 332 ± 36 ms, respectively; p = 0.0002) and late post-MI (442 ± 63 ms vs. 321 ± 40 ms and 355 ± 61 ms, respectively; p = 0.012). The standard deviation of TTP in 16 segments (SD16) significantly increased post-MI: 28 ± 7 ms to 50 ± 10 ms (early, p = 0.012) to 54 ± 19 ms (late, p = 0.004), with no change between early and late post-MI time-points (p = 0.56). TTP was not related to reduction of segmental contractility. EAM revealed late electrical activation and greatly diminished conduction velocity in the infarct (5.7 ± 2.4 cm/s), when compared to peri-infarct (18.7 ± 10.3 cm/s) and remote myocardium (39 ± 20.5 cm/s). CONCLUSIONS: Mechanical dyssynchrony occurs early after MI and is the result of delayed electrical and mechanical activation in the infarct.
Resumo:
Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.
Resumo:
PURPOSE: To implement and characterize a fluorine-19 ((19)F) magnetic resonance imaging (MRI) technique and to test the hypothesis that the (19)F MRI signal in steady state after intravenous injection of a perfluoro-15-crown-5 ether (PCE) emulsion may be exploited for angiography in a pre-clinical in vivo animal study. MATERIALS AND METHODS: In vitro at 9.4T, the detection limit of the PCE emulsion at a scan time of 10 min/slice was determined, after which the T(1) and T(2) of PCE in venous blood were measured. Permission from the local animal use committee was obtained for all animal experiments. 12 µl/g of PCE emulsion was intravenously injected in 11 mice. Gradient echo (1)H and (19)F images were obtained at identical anatomical levels. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined for 33 vessels in both the (19)F and (1)H images, which was followed by vessel tracking to determine the vessel conspicuity for both modalities. RESULTS: In vitro, the detection limit was ∼400 µM, while the (19)F T(1) and T(2) were 1350±40 and 25±2 ms. The (19)F MR angiograms selectively visualized the vasculature (and the liver parenchyma over time) while precisely coregistering with the (1)H images. Due to the lower SNR of (19)F compared to (1)H (17±8 vs. 83±49, p<0.001), the (19)F CNR was also lower at 15±8 vs. 52±35 (p<0.001). Vessel tracking demonstrated a significantly higher vessel sharpness in the (19)F images (66±11 vs. 56±12, p = 0.002). CONCLUSION: (19)F magnetic resonance angiography of intravenously administered perfluorocarbon emulsions is feasible for a selective and exclusive visualization of the vasculature in vivo.