811 resultados para Digital Media Mash up
Resumo:
CONCLUSIONS: The clinical presentation of otogenic dural sinus thrombosis (DST) as a complication of acute otitis media (AOM) can be masked by antibiotic treatment. Morning episodes of vomiting and/or headache, visual impairment and a history of AOM seem to be indicative of otogenic hydrocephalus. We therefore advocate that the MRI scans of patients with similar symptoms should be carefully studied to facilitate the early diagnosis of a potentially life-threatening complication. OBJECTIVE: To describe the frequency, pathognomonic signs, clinical course and outcome of otogenic hydrocephalus and DST as complications of AOM in pediatric patients. MATERIAL AND METHODS: We undertook a retrospective chart review of all pediatric patients (age 1-14 years) treated for otitis media and its complications at an academic medical center between 1999 and 2003. The main outcome measures were otologic and ophthalmologic findings and CT and MRI scans at the beginning of treatment and 3 months later. RESULTS: We report on five cases with otogenic DST following AOM. All but one of them presented initially with diplopia caused by otogenic hydrocephalus. In four cases the otologic complaints had already disappeared by the time of MRI confirmation of the diagnosis. Only one child was referred with severe otologic symptoms. Management included systemic antibiotics, short-term heparin anticoagulation and surgical decompression. In our cases, even after intensive i.v. antibiotic treatment, only surgery led to a significant improvement in the clinical condition.
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
The quantity of interest for high-energy photon beam therapy recommended by most dosimetric protocols is the absorbed dose to water. Thus, ionization chambers are calibrated in absorbed dose to water, which is the same quantity as what is calculated by most treatment planning systems (TPS). However, when measurements are performed in a low-density medium, the presence of the ionization chamber generates a perturbation at the level of the secondary particle range. Therefore, the measured quantity is close to the absorbed dose to a volume of water equivalent to the chamber volume. This quantity is not equivalent to the dose calculated by a TPS, which is the absorbed dose to an infinitesimally small volume of water. This phenomenon can lead to an overestimation of the absorbed dose measured with an ionization chamber of up to 40% in extreme cases. In this paper, we propose a method to calculate correction factors based on the Monte Carlo simulations. These correction factors are obtained by the ratio of the absorbed dose to water in a low-density medium □D(w,Q,V1)(low) averaged over a scoring volume V₁ for a geometry where V₁ is filled with the low-density medium and the absorbed dose to water □D(w,QV2)(low) averaged over a volume V₂ for a geometry where V₂ is filled with water. In the Monte Carlo simulations, □D(w,QV2)(low) is obtained by replacing the volume of the ionization chamber by an equivalent volume of water, according to the definition of the absorbed dose to water. The method is validated in two different configurations which allowed us to study the behavior of this correction factor as a function of depth in phantom, photon beam energy, phantom density and field size.
Resumo:
Les prioritats per als museus canvien. La missió de la nova museologia és convertir els museus en llocs per a gaudir i aprendre, cosa que fa que hagin de dur a terme una gestió financera molt semblant a la d'una empresa social que competeixi en el sector del lleure. Amb el pas del temps, els museus han d'establir i aplicar els criteris necessaris per a la supervivència, aplanant el terreny perquè altres institucions públiques siguin més obertes en els seus esforços per comunicar i difondre el seu patrimoni. Ja podem començar a parlar d'algunes conclusions comunament acceptades sobre el comportament dels visitants, que són necessàries per a planificar exposicions futures que vegin l'aprenentatge com un procés constructiu, les col·leccions com a objectes amb significat i les mateixes exposicions com a mitjans de comunicació que haurien de transformar la manera de pensar de l'espectador i que estan al servei del mateix missatge. Sembla que internet representa un mitjà efectiu per a assolir aquests objectius, ja que és capaç (a) d'adaptar-se als interessos i les característiques intel·lectuals d'un públic divers; (b) de redescobrir els significats dels objectes i adquirir un reconeixement sociocultural del seu valor per mitjà del seu potencial interactiu, i (c) de fer ús d'elements atractius i estimulants perquè tothom en gaudeixi. Per a aquest propòsit, és bàsic fer-nos les preguntes següents: quins criteris ha de seguir un museu virtual per a optimar la difusió del seu patrimoni?; quins elements estimulen els usuaris a quedar-se en una pàgina web i fer visites virtuals que els siguin satisfactòries?; quin paper té la usabilitat de l'aplicació en tot això?
Resumo:
Partiendo de la idea ampliamente aceptada de que las TIC (Tecnologías de Información y Comunicación) han tenido una profunda influencia en los modos en que la sociedad contemporánea experimenta y concibe las nociones de espacio y tiempo, y sustentándose en el contexto de la importancia adquirida por dichas nociones en la comprensión de los procesos sociales en general y estéticos en particular, esta investigación ha tenido por objetivo analizar la espacio-temporalidad en el contexto específico de la era digital. Poniendo en relación la fenomenología de los dispositivos tecnológicos con las nuevas estrategias de representación y puesta en imagen del espacio y el tiempo, nuestro propósito ha sido mostrar no sólo cómo a través de las prácticas artísticas digitales puede identificarse y analizarse el imaginario espacio-temporal de la era digital, sino también cómo éstas –basadas en una larga trayectoria estética de intersecciones entre arte y tecnología- han revestido al espacio y al tiempo de nuevas fenomenologías posibles, dando lugar a nuevas formas de percibirlos y cumpliendo, por tanto, un papel activo en la configuración de dicho imaginario y sus sucesivas transformaciones. La perspectiva teórica adoptada para esta investigación parte de las teorías postmodernas del espacio y el tiempo –considerando autores como Harvey o Jameson-, recurriendo a la sociología del Imaginario Social desarrollada por Castoriadis, Castro-Nogueira o J. L. Pintos para comprender cómo el espacio y el tiempo adquieren significaciones particulares. Combinando estas bases teóricas con los estudios visuales y los trabajos de teóricos de los medios como McLuhan, De Kerckhove o Lev Manovich, se establecerían las posibles relaciones entre las tecnologías, las representaciones sociales del espacio y el tiempo – analizadas a partir de metáforas como “compresión espacio-temporal”, “espacio de los flujos” o “tiempo atemporal” y sus relaciones con el Ciberespacio- y la fenomenología espacio-temporal de las prácticas artísticas y sus estrategias de representación visual –tomando como objeto de estudio tipologías artísticas que van desde el Hipercine a la Realidad Virtual y Aumentada, los Medios Locativos o la Telepresencia. La conclusión que hemos podido extraer de este estudio es que si bien distintos tipos de tecnologías afectan operacional y perceptivamente a la construcción social de la espacio-temporalidad, los modos en que estas tecnologías han estetizado la propia realidad y los modos en que condicionan la construcción estética de las nociones de espacio y tiempo, tanto a partir de la propia fenomenología del dispositivo como de la experimentación creativa con el mismo, ejercen una profunda influencia sobre el imaginario social y espacio-temporal propios de la era digital.
Resumo:
OBJECTIVE This study was designed to evaluate the impact of a teleassistance system on the metabolic control of type 2 diabetes patients. RESEARCH DESIGN AND METHODS We conducted a 1-year controlled parallel-group trial comparing patients randomized (1) to an intervention group, assigned to a teleassistance system using real-time transmission of blood glucose results, with immediate reply when necessary, and telephone consultations, or (2) to a control group, being regularly followed-up at their healthcare center. Study subjects were type 2 diabetes patients >30 years of age followed in the primary care setting. RESULTS A total of 328 type 2 diabetes patients were recruited from 35 family practices in the province of Málaga, Spain. There was a reduction in hemoglobin A1c after 12 months from 7.62 +/- 1.60% to 7.40 +/- 1.43% (P = 0.027) in the intervention group and from 7.44 +/- 1.31% to 7.35 +/- 1.38% (P = 0.303) in the control group. The difference in the change between groups was not statistically significant. There was also a significant decrease in systolic and diastolic blood pressure, total cholesterol, low-density lipoprotein cholesterol, and body mass index in the intervention group. In the control group, the only significant decline was in low-density lipoprotein cholesterol. CONCLUSIONS A teleassistance system using real-time transmission of blood glucose results with an option to make telephone consultations is feasible in the primary care setting as a support tool for family physicians in their follow-up of type 2 diabetes patients.
Resumo:
The Andalusian eHealth Library (BV-SSPA) was set up in 2006, but the region already had 42 librarians who worked at hospitals or other centers and were in charge of their libraries. The Digital library meant for all of them the availability of a greater amount of scientific resources and also the challenge of adapting to this new environment which brought new tasks and responsibilities to their daily work, and required the development of new skills. The time has arrived to analyze how they have implemented this change and how it has transformed their professional profile within the Andalusian Health System. Nowadays, the Andalusian eHealth Library establishes the librarian’s targets and their work is evaluated according to the fulfillment of these targets. This evaluation is carried out by the director of the BV-SSPA, taking into account the performance related to the general stated targets, as well as their level of commitment to the Digital Library through the performing of specific assigned tasks.
Resumo:
In this paper we want to present a work- in-progress research about video self production on the Internet that is part of a broader research project which explores the ways current media practices convey a 'playful' relationship with digital technologies in popular culture.
Resumo:
Aquest document és un esborrany. Amb l'objectiu d'aprofundir en el procés d'institucionalització, vam dissenyar una investigació empírica que permetés visualitzar les tendències discursives i àmbits d'activitats de les pràctiques relacionades amb les interseccions entre l'art, la ciència i la tecnologia. La metodologia va consistir en la implementació de tres bases de dades que recullen l'activitat dels últims anys en relació a: 1) els congressos (i festivals associats) realitzats a nivell internacional 2) les publicacions acadèmiques i divulgatives centrades en aquest àmbit interdisciplinar 3) els programes acadèmics.
Resumo:
A method has been developed for the determination of the oxygen uptake of small areas (0.01 mm2) in an entire chick embryo cultured in vitro under defined metabolic conditions. It is based on the recordings of the spectral changes of the hemoglobin used as oxygen source for the respiring tissue (Barzu and Borza, 1967). Rapid scanning of the hemoglobin absorbance over the preparation allows a comparison of the O2 uptake of various regions. Values of the order of 10(-2) 1 O2 . min-2 are measured in less than 10 sec with a spatial resolution of 100 micron. The differentiation of embryonic tissue is not disturbed by the measurements. The O2 diffusion in the media and in the tissue has been analyzed by digital simulation. The O2 uptake of the Hensen's node was measured from embryos starting at the stage of definitive primitive streak (stage 4) up to the stage of 10 somites. It increases from 0.6 to 1.1 nl . h-1 with a marked acceleration between stages 4 and 5. The values corrected for the protein content of the Hensen's node at stage 4, 5, 6 and 8 are 32, 30 and 28 microliter . mg-1 . h-1 respectively. The first scanning results show different patterns of the O2 utake at the level of the Hensen's node and of the neural plate. At stage 6-7, the corrected O2 uptake is 30 microliter . mg-1 . h-1 for . the former and 43 microliter . mg-1 . h-1 for the latter.
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.
Resumo:
BACKGROUND AND STUDY AIMS: The current gold standard in Barrett's esophagus monitoring consists of four-quadrant biopsies every 1-2 cm in accordance with the Seattle protocol. Adding brush cytology processed by digital image cytometry (DICM) may further increase the detection of patients with Barrett's esophagus who are at risk of neoplasia. The aim of the present study was to assess the additional diagnostic value and accuracy of DICM when added to the standard histological analysis in a cross-sectional multicenter study of patients with Barrett's esophagus in Switzerland. METHODS: One hundred sixty-four patients with Barrett's esophagus underwent 239 endoscopies with biopsy and brush cytology. DICM was carried out on 239 cytology specimens. Measures of the test accuracy of DICM (relative risk, sensitivity, specificity, likelihood ratios) were obtained by dichotomizing the histopathology results (high-grade dysplasia or adenocarcinoma vs. all others) and DICM results (aneuploidy/intermediate pattern vs. diploidy). RESULTS: DICM revealed diploidy in 83% of 239 endoscopies, an intermediate pattern in 8.8%, and aneuploidy in 8.4%. An intermediate DICM result carried a relative risk (RR) of 12 and aneuploidy a RR of 27 for high-grade dysplasia/adenocarcinoma. Adding DICM to the standard biopsy protocol, a pathological cytometry result (aneuploid or intermediate) was found in 25 of 239 endoscopies (11%; 18 patients) with low-risk histology (no high-grade dysplasia or adenocarcinoma). During follow-up of 14 of these 18 patients, histological deterioration was seen in 3 (21%). CONCLUSION: DICM from brush cytology may add important information to a standard biopsy protocol by identifying a subgroup of BE-patients with high-risk cellular abnormalities.
Resumo:
“Magic for a Pixeloscope” is a one hour show conceived to berepresented in a theater scenario that merges mixed and augmented reality (MR/AR) and full-body interaction with classical magic to create new tricks. The show was conceived by an interdisciplinary team composed by a magician, twointeraction designers, a theater director and a stage designer. Themagician uses custom based hardware and software to createnew illusions which are a starting point to explore new languagefor magical expression. In this paper we introduce a conceptualframework used to inform the design of different tricks; weexplore the design and production of some tricks included in theshow and we describe the feedback received on the world premiere and some of the conclusions obtained.
Resumo:
We present dual-wavelength Digital Holographic Microscopy (DHM) measurements on a certified 8.9 nm high Chromium thin step sample and demonstrate sub-nanometer axial accuracy. We introduce a modified DHM Reference Calibrated Hologram (RCH) reconstruction algorithm taking into account amplitude contributions. By combining this with a temporal averaging procedure and a specific dual-wavelength DHM arrangement, it is shown that specimen topography can be measured with an accuracy, defined as the axial standard deviation, reduced to at least 0.9 nm. Indeed, it is reported that averaging each of the two wavefronts recorded with real-time dual-wavelength DHM can provide up to 30% spatial noise reduction for the given configuration, thanks to their non-correlated nature. ©2008 COPYRIGHT SPIE