921 resultados para Corneal hysteresis
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias em Saúde
Resumo:
When a mixture is confined, one of the phases can condense out. This condensate, which is otherwise metastable in the bulk, is stabilized by the presence of surfaces. In a sphere-plane geometry, routinely used in atomic force microscope and surface force apparatus, it, can form a bridge connecting the surfaces. The pressure drop in the bridge gives rise to additional long-range attractive forces between them. By minimizing the free energy of a binary mixture we obtain the force-distance curves as well as the structural phase diagram of the configuration with the bridge. Numerical results predict a discontinuous transition between the states with and without the bridge and linear force-distance curves with hysteresis. We also show that similar phenomenon can be observed in a number of different systems, e.g., liquid crystals and polymer mixtures. (C). 2004 American Institute of Physics.
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias em Saúde
Resumo:
We address the problem of coordinating two non-holonomic mobile robots that move in formation while transporting a long payload. A competitive dynamics is introduced that gradually controls the activation and deactivation of individual behaviors. This process introduces (asymmetrical) hysteresis during behavioral switching. As a result behavioral oscillations, due to noisy information, are eliminated. Results in indoor environments show that if parameter values are chosen within reasonable ranges then, in spite of noise in the robots communi- cation and sensors, the overall robotic system works quite well even in cluttered environments. The robots overt behavior is stable and smooth.
Resumo:
Applied Physics Letters, Vol.93, issue 20
Resumo:
A 36-year-old black man, without history of systemic disease or ocular trauma developed a corneal infection in his left eye. He was treated with antibacterial antibiotic and corticosteroids for one month prior to diagnosis. Fungal hyphae and chlamydospores were found in a KOH preparation of the corneal scrapings, and positive cultures for Fusarium solani were obtained in Sabouraud dextrose agar. It is emphasized the cautious use of antibiotics and steroids in corneal diseases, and the need of considering the involvement of opportunistic fungi in the etiology of these infections.
Resumo:
A 39-year old male patient was admitted to the University Hospital of the Faculty of Medicine of Ribeirão Preto with signs and symptoms of sudden dyspnea, generalized myalgia and behavioral disorders. The initial suspicion was alcohol abstinence syndrome and the patient was referred for psychiatric and neurologic care. The evolution of the patient with a worsening of signs and symptoms, presence of crises of tachypnea, agitation, difficulty to swallow, irritability and hydrophobia, and his report of having been bitten by a suspected dog raised the hypothesis of rabies. The diagnosis was confirmed by examination of a corneal impression, biological tests in the cerebrospinal fluid (CSF) and saliva and visualization of Negri bodies in nervous tissue (direct immunofluorescence). The patient evolved with agitation, aggressiveness, and worsening tachypnea intercalating with apnea, and died on the 4th day after admission
Resumo:
RESUMO: A presente dissertação para tese de doutoramento apresenta o desenvolvimento e a validação de um método simples e original para o diagnóstico de calcificações vasculares em doentes em diálise, utilizando um score semiquantitativo criado por nós e obtido em RX simples da bacia e das mãos, denominado score de calcifi cação vascular simples. Demonstramos que este score vascular simples é preditor de risco cardiovascular nos doentes em diálise. O score de calcificação vascular simples associou-se ainda à baixa densidade mineral óssea avaliada por dual energy X -ray absortiometry (DXA) no colo do fémur. Verifi camos igualmente que, em doentes em diálise, as calcifi cações coronárias quantifi cadas pelo score de Agatston e o score de calcifi cação vascular simples se associaram a um menor volume ósseo avaliado em biopsias ósseas. Estes trabalhos corroboram a hipótese da existência de um elo de ligação entre a doença óssea e a doença vascular nos doentes em diálise, e um dos elementos que contribuem para este elo de ligação podem ser as calcificações vasculares. Este score de calcificação vascular simples avalia calcifi cações em artérias de grande, médio e pequeno calibre, e inclui os dois padrões radiológicos de calcificação: calcificação linear, associada à calcifi cação da camada média da parede arterial, e calcificação irregular, associada à calcifi cação da camada íntima arterial1. Nos diferentes trabalhos por nós publicados demonstramos que as calcificações vasculares avaliadas por este método simples e barato permitem a identificação de indivíduos com elevado risco cardiovascular. Este score vascular associa -se a maior risco de mortalidade cardiovascular2, de mortalidade de causa global3, de internamentos cardiovasculares2, de doença ardiovascular2, de doença arterial periférica2,4,de calcifi cações valvulares5 e de rigidez arterial3. As guidelines KDIGO (Kidney disease: improving global outcomes), publicadas em 2009,sugerem que os doentes renais crónicos nos estadios 3 a 5, com calcificações vasculares e valvulares, devem ser considerados como apresentando o mais elevado risco cardiovascular6. A elevada mortalidade dos doentes renais crónicos não é totalmente explicada pelos fatores de risco tradicionais7. A organização KDIGO defende, desde 2006, a hipótese da existência de um elo de ligação entre a doença óssea e a doença vascular8. Esta ligação pode ser explicada pelas alterações do metabolismo mineral e ósseo e pela sua interação com as calcificações vasculares. Verificamos, nos nossos trabalhos, uma associação entre calcifi cações vasculares e doença óssea. O baixo volume ósseo diagnosticado por análise histomorfométrica de biopsias ósseas foi preditor de maior risco de calcificações vasculares avaliadas pelo score de calcifi cação vascular simples (dados apresentados nesta dissertação, no capítulo 6) e pelo score coronário de Agatston num grupo de doentes em diálise9. A contribuição original deste artigo9 foi considerada merecedora de um editorial feito pelo Dr. Gérard London10, investigador líder na área da calcificação vascular dos doentes renais crónicos e actual Presidente da EDTA (European Dialysis and Transplantation Association). Fomos também os primeiros a descrever uma associação independente e inversa entre a densidade mineral avaliada no colo do fémur por DXA (dual energy X -ray absortiometry) com calcificações vasculares avaliadas pelo score de calcificação vascular simples, com rigidez arterial avaliada por velocidade de onda de pulsocarotidofemoral e com doença arterial periférica diagnosticada por critérios clínicos11. Fomos igualmente os primeiros a mostrar uma correlação signifi cativa entre a densidade mineral óssea avaliada por DXA no colo do fémur, mas não na coluna lombar, com a espessura cortical avaliada por análise histomorfométrica em biopsia óssea12. O nosso estudo atribui pela primeira vez à DXA um papel no diagnóstico de porosidade cortical nos doentes em diálise. A utilidade da avaliação diferencial da densidade mineral óssea cortical e trabecular necessita ainda de ser confirmada em estudos prospectivos. Este achado inovador do nosso estudo foi mencionado pela ERBP (European Renal Best Practice) no comentário feito à posição da KDIGO que considera ser reduzida a utilidade da densidade mineral óssea nos doentes em diálise13. Dois dos trabalhos incluídos nesta dissertação foram referenciados nas guidelines KDIGO 2009 para avaliar a prevalência das calcificações vasculares (KDIGO 2009: Tabela suplementar 10, Fig. 3.6) e para validar a associação entre calcificações vasculares e mortalidade cardiovascular (KDIGO 2009: Tabela suplementar 12, Fig. 3.7)6. A inclusão destes nossos dois estudos nas referências destas guidelines, que utilizaram o exigente sistema GRADE (Grades of recommendation, assessment, development, and evaluation) na classificação e selecção dos estudos, valida o interesse científico dos nossos trabalhos. O diagnóstico de calcificações vasculares tem um interesse prático para os doentes renais crónicos. A presença de calcifi cações vasculares é um sinal de alerta para a existência de um elevado risco cardiovascular, e esta informação pode ser utilizada para modificar a terapêutica nestes doentes6. Diferentes métodos podem ser usados para diagnosticar calcificações vasculares nos doentes em diálise14,15. O score de calcificação vascular simples tem a vantagem da simplicidade e de poder ser facilmente interpretado pelo nefrologista, sem necessidade de um radiologista. A reprodutibilidade deste score já foi demonstrada por diferentes grupos em estudos nacionais e internacionais16-24. Nestes estudos foi demonstrado que as calcifi cações vasculares avaliadas pelo método criado por nós são preditoras de maior risco de eventos cardiovasculares16, de amputações dos membros inferiores17, de velocidade de onda de pulso18,19, de calcificações corneanas e conjuntivais20 e de calcifi cações coronárias21. Também foi demonstrada uma associação inversa entre o score de calcificação vascular simples com os níveis séricos de PTH21, com os níveis de 25(OH)vitamina D 22,23 e com os níveis de fetuína A19,24. Todos estes estudos, realizados por diferentes grupos, que utilizaram o score de calcificação vascular simples na sua metodologia, comprovam a facilidade de utilização deste score e a concordância de resultados atestam a sua reprodutibilidade e a utilidade na avaliação dos doentes renais crónicos. ---------------------------ABSTRACT: This thesis presents the development and validation of a simple and original method to identify vascular calcifications in dialysis patients, using a semi -quantitative score that we have created and that is obtained in plain X -ray of pelvis and hands. This score was named in different publications as “simple vascular calcifi cation score”. We have demonstrated that this score is a predictor of higher cardiovascular risk in dialysis patients. The simple vascular calcification score was also associated with lower mineral bone density evaluated by DXA in femoral neck. In hemodialysis patients coronary calcifications evaluated by the coronary Agatston score and by the simple vascular calcification score were associated with lower bone volume analysed in bone biopsies. These studies corroborate the hypothesis of the existence of a link between bone disease and vascular disease in dialysis patients and one of the elements of this link may be vascular calcifications. This simple vascular calcification score identifi es calcifications in large, medium and small calibre arteries and includes the two radiological patterns of arterial calcifi cation: linear calcification which has been associated with the calcifi cation of the media layer of the arterial wall and irregular and patchy calcification which has been associated with the calcifi cation of the intima layer of the arterial wall1. In the several studies that we have published we have demonstrated that vascular calcifications evaluated by this simple and inexpensive method allow the identification of patients with high cardiovascular risk. This simple vascular calcification score is an independent predictor of cardiovascular mortality2, all -cause mortality3, cardiovascular hospitalizations2, cardiovascular disease2, peripheral artery disease2,4, valvular calcifi cations5 and arterial stiffness3.KDIGO (Kidney Disease: Improving Global Outcomes) guidelines published in 2009 suggest that chronic kidney disease patients in stages 3 to 5, with vascular and valvular calcifications should be considered to be at the highest cardiovascular risk6. The high mortality of chronic kidney disease patients is not completely explained by the traditional risk factors7 and KDIGO group supports, since 2006, the hypothesis of the existence of a link between bone disease and vascular disease8.This link may be explained by the alterations of the bone and mineral metabolism and their interaction with development and progression of vascular calcifications. We have also verifi ed in our studies the existence of an association between vascular calcifications and bone disease. Low bone volume diagnosed by histomorphometric analysis of bone biopsies, in a group of dialysis patients, was independently associated with the simple vascular calcification score (data presented in this thesis,chapter 6) and with coronary calcifications evaluated by the Agatston score9. The original contribution of this article published in CJASN9 deserved a commentary in an Editorial written by Prof. Gérard London10 leader investigator in this area and current EDTA (European Dialysis and Transplantation Association) President. We were also the fi rst group to describe an independent and inverse association between bone mineral density evaluated in the femoral neck by DXA (dual energy X -ray absortiometry) with vascular calcifications evaluated by the simple vascular calcification score, with arterial stiffness evaluated by carotid-femoral pulse wave velocity and with peripheral artery disease diagnosed by clinical criteria11. We were also the first group to demonstrate a significant correlation between bone mineral density evaluated by DXA in femoral neck but not in lumbar spine, with cortical thickness evaluated by histomorphometric analysis of bone biopsy12. Our study has attributed to DXA, for the first time, a role in the diagnosis of cortical porosity in dialysis patients. The clinical utility of the differential evaluation of bone mineral density in cortical or trabecular bone needs, however, to be confi rmed in prospective studies. This original fi nding of our study was mentioned by ERBP (European Renal Best Practice) commenting the KDIGO position in relation with the reduced utility of bone mineral density evaluation in dialysis patients13. Two of the studies included in this thesis have been integrated in a group of studies selected as references by the KDIGO guidelines published in 2009 to evaluate the prevalence of vascular calcifications in CKD patients (KDIGO 2009: Supplementary Table 10, Fig. 3.6) and to corroborate the association between vascular calcifications and cardiovascular mortality (KDIGO 2009: Supplementary Table 12, Fig. 3.7)6. The inclusion of both studies as references in the KDIGO guidelines that have used the exigent GRADE system (Grades of Recommendation, Assessment, Development, and Evaluation) in the classifi cation and selection of studies, validates the scientifi c value of our studies. The diagnosis of vascular calcifi cations has a practical interest for chronic kidney disease patients. The presence of vascular calcifications is an alert sign to the existence of a high cardiovascular risk and this information may be used to modify the treatment of these patients6. Different methods may be used to detect the presence of vascular calcifications in dialysis patients14,15. The simple vascular calcifi cation score has the advantage of being simple, inexpensive and easily evaluated by the Nephrologist without the need for a Radiologist interpretation. The reproducibility of this method has already been demonstrated by other groups in national and international studies16 -24. It was demonstrated in those studies that vascular calcifi cations evaluated by the method created by us, predict higher risk of cardiovascular events16, higher risk of lower limbs amputations17, higher pulse wave velocity18,19, corneal and conjuntival calcifi cations 20 and coronary calcifi cations21. A negative association between the simple vascular calcification score and PTH levels21, 25(OH) vitamin D levels22,23 and Fetuin A levels19,24 has also been demonstrated. All these studies performed by different groups that have used the simple vascular calcifi cation score in their methods demonstrate that this score is simple, useful and reproducible in the evaluation of chronic kidney disease patients simple, useful and reproducible in the evaluation of chronic kidney disease patients.
Resumo:
Recent changes in regulatory requirements and social views on animal testing have incremented the development of reliable alternative tests for predicting skin and ocular irritation potential of products based on new raw materials. In this regard, botanical ingredients used in cosmetic products are among those materials, and should be carefully reviewed concerning the potential presence of irritant constituents. In particular, cosmetic products used on the face, in vicinity of the eyes or that may come in contact with mucous membranes, should avoid botanical ingredients that contain, or are suspected to contain, such ingredients. In this study, we aimed to evaluate the effect of a new cosmetic ingredient, namely, coffee silverskin (CS), with an in vitro skin and ocular irritation assay using reconstructed human epidermis, EpiSkin™, and human corneal epithelial model, SkinEthics™ HCE, and an in vivo assay. Three different extracts of CS were evaluated. The histology of the models after extracts applications was analysed. The in vitro results demonstrated that extracts were not classified as irritant and the histological analyses proved that extracts did not affect both models structure. The content of caffeine, 5-hydroxymethyl furfural and chlorogenic acid was quantified after the epidermal assay. The in vivo test carried out with the most promising extract (hydroalcoholic) showed that, with respect to irritant effects, these extracts can be regarded as safe for topical application.
Resumo:
PURPOSE: 1. Identify differences in optic nerve sheath diameter (ONSD) as an indirect measure of intracranial pressure (ICP) in glaucoma patients and a healthy population. 2. Identify variables that may correlate with ONSD in primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG) patients. METHODS: Patients with NTG (n = 46) and POAG (n = 61), and healthy controls (n = 42) underwent B-scan ultrasound measurement of ONSD by an observer masked to the patient diagnosis. Intraocular pressure (IOP) was measured in all groups, with additional central corneal thickness (CCT) and visual field defect measurements in glaucomatous patients. Only one eye per patient was selected. Kruskal-Wallis or Mann-Whitney were used to compare the different variables between the diagnostic groups. Spearman correlations were used to explore relationships among these variables. RESULTS: ONSD was not significantly different between healthy, NTG and POAG patients (6.09 ± 0.78, 6.03 ± 0.69, and 5.71 ± 0.83 respectively; p = 0.08). Visual field damage and CCT were not correlated with ONSD in either of the glaucoma groups (POAG, p = 0.31 and 0.44; NTG, p = 0.48 and 0.90 respectively). However, ONSD did correlate with IOP in NTG patients (r = 0.53, p < 0.001), while it did not in POAG patients and healthy controls (p = 0.86, p = 0.46 respectively). Patient's age did not relate to ONSD in any of the groups (p > 0.25 in all groups). CONCLUSIONS: Indirect measurements of ICP by ultrasound assessment of the ONSD may provide further insights into the retrolaminar pressure component in glaucoma. The correlation of ONSD with IOP solely in NTG patients suggests that the translaminar pressure gradient may be of particular importance in this type of glaucoma.
Resumo:
INTRODUCTION: Predicting outcome in comatose survivors of cardiac arrest is based on data validated by guidelines that were established before the era of therapeutic hypothermia. We sought to evaluate the predictive value of clinical, electrophysiological and imaging data on patients submitted to therapeutic hypothermia. MATERIALS AND METHODS: A retrospective analysis of consecutive patients receiving therapeutic hypothermia during years 2010 and 2011 was made. Neurological examination, somatosensory evoked potentials, auditory evoked potentials, electroencephalography and brain magnetic resonance imaging were obtained during the first 72 hours. Glasgow Outcome Scale at 6 months, dichotomized into bad outcome (grades 1 and 2) and good outcome (grades 3, 4 and 5), was defined as the primary outcome. RESULTS: A total of 26 patients were studied. Absent pupillary light reflex, absent corneal and oculocephalic reflexes, absent N20 responses on evoked potentials and myoclonic status epilepticus showed no false-positives in predicting bad outcome. A malignant electroencephalographic pattern was also associated with a bad outcome (p = 0.05), with no false-positives. Two patients with a good outcome showed motor responses no better than extension (false-positive rate of 25%, p = 0.008) within 72 hours, both of them requiring prolonged sedation. Imaging findings of brain ischemia did not correlate with outcome. DISCUSSION: Absent pupillary, corneal and oculocephalic reflexes, absent N20 responses and a malignant electroencephalographic pattern all remain accurate predictors of poor outcome in cardiac arrest patients submitted to therapeutic hypothermia. CONCLUSION: Prolonged sedation beyond the hypothermia period may confound prediction strength of motor responses.
Resumo:
Nos últimos anos tem-se assistido à introdução de novos dispositivos de medição da poluição do ar baseados na utilização de sensores de baixo custo. A utilização menos complexa destes sistemas, possibilita a obtenção de dados com elevada resolução temporal e espacial, abrindo novas oportunidades para diferentes metodologias de estudos de monitorização da poluição do ar. Apesar de apresentarem capacidades analíticas distantes dos métodos de referência, a utilização destes sensores tem sido sugerida e incentivada pela União Europeia no âmbito das medições indicativas previstas na Diretiva 2008/50/CE, com uma incerteza expandida máxima de 25%. O trabalho desenvolvido no âmbito da disciplina de Projeto consistiu na escolha, caracterização e utilização em medições reais de um sensor de qualidade do ar, integrado num equipamento protótipo desenvolvido com esse fim, visando obtenção uma estimativa da incerteza de medição associada à utilização deste dispositivo através da aplicação da metodologia de demonstração de equivalência de métodos de medição de qualidade do ar definida pela União Europeia. A pesquisa bibliográfica realizada permitiu constatar que o monóxido de carbono é neste momento o parâmetro de qualidade do ar que permite ser medido de forma mais exata através da utilização de sensores, nomeadamente o sensor eletroquímico da marca Alphasense, modelo COB4, amplamente utilizado em projetos de desenvolvimento neste cotexto de monitorização ambiental. O sensor foi integrado num sistema de medição com o objetivo de poder ser utlizado em condições de autonomia de fornecimento de energia elétrica, aquisição interna dos dados, tendo em consideração ser o mais pequeno possível e de baixo custo. Foi utlizado um sistema baseado na placa Arduino Uno com gravação de dados em cartão de memória SD, baterias e painel solar, permitindo para além do registo das tensões elétricas do sensor, a obtenção dos valores de temperatura, humidade relativa e pressão atmosférica, com um custo global a rondar os 300 euros. Numa primeira fase foram executados um conjunto de testes laboratoriais que permitiram a determinação de várias características de desempenho em dois sensores iguais: tempo de resposta, a equação modelo do sensor, avaliação da repetibilidade, desvio de curto e longo termo, interferência da temperatura e histerese. Os resultados demonstraram um comportamento dos sensores muito linear, com um tempo de resposta inferior a um minuto e com uma equação modelo do sensor dependente da variação da temperatura. A estimativa da incerteza expandida laboratorial ficou, para ambos os sensores, abaixo dos 10%. Após a realização de duas campanhas reais de medição de CO em que os valores foram muito baixos, foi realizada uma campanha de quinze dias num parque de estacionamento subterrâneo que permitiu a obtenção de concentrações suficientemente elevadas e a comparação dos resultados dos sensores com o método de referência em toda a gama de medição (0 a 12 mol.mol-1). Os valores de concentração obtidos pelos dois sensores demonstraram uma excelente correlação com o método de referência (r2≥0,998), obtendo-se resultados para a estimativa da incerteza expandida de campo inferiores aos obtidos para a incerteza laboratorial, cumprindo o objetivo de qualidade de dados definido para as medições indicativas de incerteza expandida máxima de 25%. Os resultados observados durante o trabalho realizado permitiram confirmar o bom desempenho que este tipo de sensor pode ter no âmbito de medições de poluição do ar com um caracter mais indicativo.
Resumo:
In order to determine the prevalence of ocular lesions in HTLV-1 infected patients in Salvador Bahia, a transversal study was conducted on 140 HTLV-1 infected patients (90 asymptomatic and 50 tropical spastic paraparesis/HTLV-1-associated myelopathy) between June 2004 and November 2005. The ophthalmological examination included visual acuity measurement, ocular motility, biomicroscopy of the anterior and posterior chambers, intraocular pressure and evaluation of lachrymal secretion. Observation verified 4 (2.8%) out of 140 patients with uveitis (two patients had intermediate uveitis and two had pan-uveitis) and 39 (36.4%) out of 107 patients with keratoconjunctivitis sicca. The prevalence of Keratoconjunctivitis sicca was significantly higher among the TSP/HAM patients (OR age adjusted=3.64; 95%CI 1.59-8.32). Uveitis and corneal opacities were also important findings, indicating the strong need for periodic ophthalmological follow-up in all HTLV-1 subjects.
Resumo:
The present dissertation focuses on the research of the recent approach of innovative high-temperature superconducting stacked tapes in electrical ma-chines applications, taking into account their potential benefits as an alternative for the massive superconducting bulks, mainly related with geometric and me-chanical flexibility. This work was developed in collaboration with Institut de Ciència de Ma-terials de Barcelona (ICMAB), and is related with evaluation of electrical and magnetic properties of the mentioned superconducting materials, namely: analysis of magnetization of a bulk sample through simulations carried out in the finite elements COMSOL software; measurement of superconducting tape resistivity at liquid nitrogen and room temperatures; and, finally, development and testing of a frequency controlled superconducting motor with rotor built by superconducting tapes. In the superconducting state, results showed a critical current density of 140.3 MA/m2 (or current of 51.15 A) on the tape and a 1 N∙m developed motor torque, independent from the rotor position angle, typical in hysteresis motors.
Resumo:
The manipulation of electric ordering with applied magnetic fields has been realized on magnetoelectric (ME) materials, however, their ME switching is often accompanied by significant hysteresis and coercivity that represents, for some applications, a severe weakness. To overcome this obstacle, this work focus on the development of a new type of ME polymer nanocomposites that exhibits tailored ME response at room temperature. The multiferroic nanocomposites are based on three different ferrite nanoparticles, Zn0.2Mn0.8Fe2O4 (ZMFO), CoFe2O4 (CFO) and Fe3O4 (FO), dispersed in a piezoelectric co-polymer poly(vinylindene fluoride-trifluoroethylene), P(VDF-TrFE), matrix. No substantial differences were detected on the time-stable piezoelectric response of the composites (≈ -28 pC.N−1) with distinct ferrite fillers and for the same ferrite content of 10wt.%. Magnetic hysteresis loops from pure ferrite nanopowders showed different magnetic responses. ME results of the nanocomposite films with 10wt.% ferrite content revealed that the ME induced voltage increases with increasing DC magnetic field until a maximum of 6.5 mV∙cm−1∙Oe−1, at an optimum magnetic field of 0.26 T, and 0.8 mV∙cm−1∙Oe−1, at an optimum magnetic field of 0.15T, for the CFO/P(VDF-TrFE) and FO/P(VDF-TrFE) composites, respectively. On the contrary, the ME response of the ZMFO/P(VDF-TrFE) exposed no hysteresis and high dependence on the ZMFO filler content. Possible innovative applications such as memories and information storage, signal processing, ME sensors and oscillators have been addressed for such ferrite/PVDF nanocomposites.