948 resultados para Cardiac Output, Low
Resumo:
OBJECTIVES: To evaluate the role of endothelin-1 (ET-1) in hypertension, we investigated density and distribution of ETA and ETB receptors in hearts and kidneys of deoxycorticosterone acetate (DOCA)-salt and 1 kidney -- 1 clip (1K1C) hypertensive rats. METHODS: Five groups of uninephrectomized Wistar rats were put on a low salt diet. Three groups of rats drank tap water and two groups received saline. One group of each regimen received DOCA subcutaneously and two corresponding groups without DOCA served as controls. The fifth group of rats had the renal artery clipped to induce 1K1C hypertension. At 6 weeks, mean arterial pressure (MAP) was recorded and membrane binding assays using 125I-ET-1 were carried out. RESULTS: MAP was increased from control 122 +/- 3 to 155 +/- 6 and 218 +/- 11 mmHg in DOCA-salt and 1K1C rats, respectively, and cardiac weight index was increased. ETA receptors were predominantly expressed in the heart, whereas ETB receptors were predominant in the kidney. In the kidneys, the density of the ETB receptor subtype was upregulated in DOCA-salt and 1K1C rats from 160 +/- 8 to 217 +/- 12 and 190 +/- 2 fmol/mg (P < 0.05), respectively, and ETA tended to be downregulated (P = 0.057). Plasma renin activity was decreased in DOCA-salt rats from 17 +/- 3 to 0.17 +/- 0.01 ng/ml per h and increased in 1K1C rats on low salt diet to 30 +/- 5 ng/ml per h. CONCLUSIONS: Since ETB is the predominant endothelin receptor in the kidneys, upregulation of the ETB receptor mediating vasodilation and downregulation of the ETA receptor mediating vasoconstriction would be compatible with a mainly renal counter-regulatory effect of endothelin-1 to hypertension. Both low and high renin models of hypertension may be affected.
Resumo:
Questionnaire studies indicate that high-anxious musicians may suffer from hyperventilation symptoms before and/or during performance. Reported symptoms include amongst others shortness of breath, fast or deep breathing, dizziness and thumping heart. A self-report study by Widmer, Conway, Cohen and Davies (1997) shows that up to seventy percent of the tested highly anxious musicians are hyperventilators during performance. However, no study has yet tested if these self-reported symptoms reflect actual cardiorespiratory changes just before and during performance. Disturbances in breathing patterns and hyperventilation may negatively affect the performance quality in stressful performance situations. The main goal of this study is to determine if music performance anxiety is manifest physiologically in specific correlates of cardiorespiratory activity. We studied 74 professional music students of Swiss Music Universities divided into two groups (high- and lowanxious) based on their self-reported performance anxiety (State-Trait Anxiety Inventory by Spielberger). The students were tested in three distinct situations: baseline, performance without audience, performance with audience. We measured a) breathing patterns, end-tidal carbon dioxide, which is a good non-invasive estimator for hyperventilation, and cardiac activation and b) self-perceived emotions and self-perceived physiological activation. Analyses of heart rate, respiratory rate, self-perceived palpitations, self-perceived shortness of breath and self-perceived anxiety for the 15 most and the 15 least anxious musicians show that high-anxious and low-anxious music students have a comparable physiological activation during the different measurement periods. However, highanxious music students feel significantly more anxious and perceive significantly stronger palpitations and significantly stronger shortness of breath just before and during a public performance. The results indicate that low- and high-anxious music students a) do not differ in the considered physiological responses and b) differ in the considered self-perceived physiological symptoms and the selfreported anxiety before and/or during a public performance.
Resumo:
OBJECTIVES: To review and update the evidence on predictors of poor outcome (death, persistent vegetative state or severe neurological disability) in adult comatose survivors of cardiac arrest, either treated or not treated with controlled temperature, to identify knowledge gaps and to suggest a reliable prognostication strategy. METHODS: GRADE-based systematic review followed by expert consensus achieved using Web-based Delphi methodology, conference calls and face-to-face meetings. Predictors based on clinical examination, electrophysiology, biomarkers and imaging were included. RESULTS AND CONCLUSIONS: Evidence from a total of 73 studies was reviewed. The quality of evidence was low or very low for almost all studies. In patients who are comatose with absent or extensor motor response at ?72h from arrest, either treated or not treated with controlled temperature, bilateral absence of either pupillary and corneal reflexes or N20 wave of short-latency somatosensory evoked potentials were identified as the most robust predictors. Early status myoclonus, elevated values of neuron specific enolase at 48-72h from arrest, unreactive malignant EEG patterns after rewarming, and presence of diffuse signs of postanoxic injury on either computed tomography or magnetic resonance imaging were identified as useful but less robust predictors. Prolonged observation and repeated assessments should be considered when results of initial assessment are inconclusive. Although no specific combination of predictors is sufficiently supported by available evidence, a multimodal prognostication approach is recommended in all patients.
Resumo:
OBJECTIVES: We assessed the clinical characteristics of patients with acute ischemic stroke (AIS) with left ventricular ejection fraction (EF) ≤ 35% and investigated the association of low EF with early and long-term outcome. METHODS: A total of 2439 patients of the Acute Stroke Registry and Analysis of Lausanne (ASTRAL) were selected. Demographics, risk factors, pre-stroke treatment, and clinical, radiological and metabolic variables in patients with and without low EF were compared. Functional independence (modified Rankin Score ≤ 2) and mortality were recorded 1 week up to 12 months from admission. RESULTS: Low EF patients (n=119) were more commonly men, older, had higher rates of coronary artery disease and atrial fibrillation (AF), and more frequent pretreatment with anticoagulants, antiplatelets and antihypertensive agents. On admission, they presented with higher stroke severity and had lower values of systolic blood pressure, higher heart rate, and worse estimated glomerular filtration rate. Stroke-related disability and death rates were higher in low EF patients during follow-up (19.5% vs. 7.8% at 1 week, and 36.1% vs. 16.5% at 12 months). Increasing age, stroke severity, and AF were independent predictors of one-year mortality in these patients while prior use of statins had a favorable effect on early mortality. CONCLUSIONS: AIS in patients with low EF is associated with older age, cardiac comorbidities, and more severe clinical presentation. Low EF can identify a subset of AIS patients at high risk of early and long-term functional disability and mortality.
Resumo:
Purpose: Although several approaches have been already used to reduce radiation dose, CT doses are still among the high doses in radio-diagnostic. Recently, General Electric introduced a new imaging reconstruction technique, adaptive statistical iterative reconstruction (ASIR), allows to taking into account the statistical fluctuation of noise. The benefits of ASIR method were assessed through classic metrics and the evaluations of cardiac structures by radiologists. Methods and materials: A 64-row CT (MDCT) was employed. Catphan600 phantom acquisitions and 10 routine-dose CT examinations performed at 80 kVp were reconstructed with FBP and with 50% of ASIR. Six radiologists then assessed the visibility of main cardiac structures using the visual grading analysis (VGA) method. Results: On phantoms, for a constant value of SD (25 HU), CTDIvol is divided by 2 (8 mGy to 4 mGy) when 50% of ASIR is used. At constant CTDIvol, MTF medium frequencies were also significantly improved. First results indicated that clinical images reconstructed with ASIR had a better overall image quality compared with conventional reconstruction. This means that at constant image quality the radiation dose can be strongly reduced. Conclusion: The first results of this study shown that the ASIR method improves the image quality on phantoms by decreasing noise and improving resolution with respect to the classical one. Moreover, the benefit obtained is higher at lower doses. In clinical environment, a dose reduction can still be expected on 80 kVp low dose pediatric protocols using 50% of iterative reconstruction. Best ASIR percentage as a function of cardiac structures and detailed protocols will be presented for cardiac examinations.
Resumo:
PRINCIPLES: Cardiac myxoma is the most commonly diagnosed cardiac tumour. Infection of herpes simplex virus 1 (HSV1) has been postulated to be a factor for this pathologic entity. The aim of the current study was to evaluate the association between HSV 1 and myxoma occurrence.METHODS: Between 1965 and 2005, 70 patients (36 female, mean age: 52.6 years) underwent a resection of myxoma. Selected variables such as hospital mortality and morbidity were studied. A follow-up (FU; mean FU time: 138 +/- 83 months) was obtained (76% complete). Immunohistological studies with monoclonal antibodies against HSV type 1 were performed on tumour biopsies of 40 patients.RESULTS: The mean age was 53 +/- 16 years (range 23 to 84 years, 51% female). Of the investigated population, 31 (44%) were in New York Heart Association (NYHA) class III-IV. Mitral valve stenosis was identified in 14 patients (20%), and in 25 (36%) patients mitral valve was insufficient. During hospitalisation 3 patients suffered from a transient neurological disorder, and in addition to myxoma resection 18 (25.7%) patients had to undergo an additional intervention. The overall survival rate was 91% at 40 years. There was no early postoperative mortality in follow-up, although 4 patients died and 2 patients had been re-operated on for recurrent myxomas after 2 and 9 years. Immunohistology revealed no positive signals for HSV-1 antigens among the 40 analysed cases.CONCLUSION: Complete surgical resection, septum included, was the treatment of choice and mandatory to prevent relapse. Peri-operative morbidity and mortality over 40 years remained low, and no association between HSV infection and occurrence of cardiac myxoma was found.
Resumo:
In this article we extend the rational partisan model of Alesina and Gatti (1995) to include a second policy, fiscal policy, besides monetary policy. It is shown that, with this extension, the politically induced variance of output is not always eliminated nor reduced by delegating monetary policy to an independent and conservative central bank. Further, in flation and output stabilisation will be affected by the degree of conservativeness of the central bank and by the probability of the less in flation averse party gaining power. Keywords: rational partisan theory; fiscal policy; independent central bank JEL Classi fication: E58, E63.
Resumo:
For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.
Resumo:
Objective: Respiratory assistance with nasal continuous positive airway pressure (n-CPAP) is an effective treatment in premature newborns presenting respiratory distress. The aim of the study was to depict cardiac function, systemic (Qs) and pulmonary output (Qp) by echocardiography in stable premature infants requiring prolonged n-CPAP. Our hypothesis was that n-CPAP could reduce pulmonary blood flow. Patients and methods: All premature infants < 32 weeks gestation, > 7 days-old, requiring n-CPAP without severe respiratory compromise nor need for additional oxygen were prospectively included. Every patient had a first echocardiography while on n-CPAP. N-CPAP was then discontinued for two hours and a second echocardiography was performed. Results: 17 premature infants were included. Mean gestational age was 28 ± 2 weeks and mean weight 1.1 ± 0.3 kg. Following retrieval of n-CPAP we observed an increase in Qp of 53 ml/kg/min (95% CI 19-87 ml/kg/min), but no significant change in Qs. Consecutively a significant increase in Qp/Qs ratio of 16% was found (95% CI 7-29%). Conclusions: Nasal continuous positive airway pressure has hemodynamic effects in preterm infants in stable pulmonary and cardiac conditions. It reduces pulmonary output without interference with systemic output.
Resumo:
This study compares different rotor structures of permanent magnet motors with fractional slot windings. The surface mounted magnet and the embedded magnet rotor structures are studied. This thesis analyses the characteristics of a concentrated two-layer winding, each coil of which is wound around one tooth and which has a number of slots per pole and per phase less than one (q < 1). Compared to the integer slot winding, the fractional winding (q < 1) has shorter end windings and this, thereby, makes space as well as manufacturing cost saving possible. Several possible ways of winding a fractional slot machine with slots per pole and per phase lessthan one are examined. The winding factor and the winding harmonic components are calculated. The benefits attainable from a machine with concentrated windingsare considered. Rotor structures with surface magnets, radially embedded magnets and embedded magnets in V-position are discussed. The finite element method isused to solve the main values of the motors. The waveform of the induced electro motive force, the no-load and rated load torque ripple as well as the dynamic behavior of the current driven and voltage driven motor are solved. The results obtained from different finite element analyses are given. A simple analytic method to calculate fractional slot machines is introduced and the values are compared to the values obtained with the finite element analysis. Several different fractional slot machines are first designed by using the simple analytical methodand then computed by using the finite element method. All the motors are of thesame 225-frame size, and have an approximately same amount of magnet material, a same rated torque demand and a 400 - 420 rpm speed. An analysis of the computation results gives new information on the character of fractional slot machines.A fractional slot prototype machine with number 0.4 for the slots per pole and per phase, 45 kW output power and 420 rpm speed is constructed to verify the calculations. The measurement and the finite element method results are found to beequal.
Resumo:
This thesis presents an alternative approach to the analytical design of surface-mounted axialflux permanent-magnet machines. Emphasis has been placed on the design of axial-flux machines with a one-rotor-two-stators configuration. The design model developed in this study incorporates facilities to include both the electromagnetic design and thermal design of the machine as well as to take into consideration the complexity of the permanent-magnet shapes, which is a typical requirement for the design of high-performance permanent-magnet motors. A prototype machine with rated 5 kW output power at 300 min-1 rotation speed has been designed and constructed for the purposesof ascertaining the results obtained from the analytical design model. A comparative study of low-speed axial-flux and low-speed radial-flux permanent-magnet machines is presented. The comparative study concentrates on 55 kW machines with rotation speeds 150 min-1, 300 min-1 and 600 min-1 and is based on calculated designs. A novel comparison method is introduced. The method takes into account the mechanical constraints of the machine and enables comparison of the designed machines, with respect to the volume, efficiency and cost aspects of each machine. It is shown that an axial-flux permanent-magnet machine with one-rotor-two-stators configuration has generally a weaker efficiency than a radial-flux permanent-magnet machine if for all designs the same electric loading, air-gap flux density and current density have been applied. On the other hand, axial-flux machines are usually smaller in volume, especially when compared to radial-flux machines for which the length ratio (axial length of stator stack vs. air-gap diameter)is below 0.5. The comparison results show also that radial-flux machines with alow number of pole pairs, p < 4, outperform the corresponding axial-flux machines.
Resumo:
Hydrogenated nanocrystalline silicon (nc-Si:H) obtained by hot-wire chemical vapour deposition (HWCVD) at low substrate temperature (150 °C) has been incorporated as the active layer in bottom-gate thin-film transistors (TFTs). These devices were electrically characterised by measuring in vacuum the output and transfer characteristics for different temperatures. The field-effect mobility showed a thermally activated behaviour which could be attributed to carrier trapping at the band tails, as in hydrogenated amorphous silicon (a-Si:H), and potential barriers for the electronic transport. Trapped charge at the interfaces of the columns, which are typical in nc-Si:H, would account for these barriers. By using the Levinson technique, the quality of the material at the column boundaries could be studied. Finally, these results were interpreted according to the particular microstructure of nc-Si:H.
Resumo:
Nitric oxide (NO) produced by inducible NO synthase (iNOS, NOS-2) is an important component of the macrophage-mediated immune defense toward numerous pathogens. Murine macrophages produce NO after cytokine activation, whereas, under similar conditions, human macrophages produce low levels or no NO at all. Although human macrophages can express iNOS mRNA and protein on activation, whether they possess the complete machinery necessary for NO synthesis remains controversial. To define the conditions necessary for human monocytes/macrophages to synthesize NO when expressing a functional iNOS, the human monocytic U937 cell line was engineered to synthesize this enzyme, following infection with a retroviral expression vector containing human hepatic iNOS (DFGiNOS). Northern blot and Western blot analysis confirmed the expression of iNOS in transfected U937 cells both at the RNA and protein levels. NOS enzymatic activity was demonstrated in cell lysates by the conversion of L-[3H]arginine into L-[3H]citrulline and the production of NO by intact cells was measured by nitrite and nitrate accumulation in culture supernatants. When expressing functional iNOS, U937 cells were capable of releasing high levels of NO. NO production was strictly dependent on supplementation of the culture medium with tetrahydrobiopterin (BH4) and was not modified by stimulation of the cells with different cytokines. These observations suggest that (1) human monocytic U937 cells contain all the cofactors necessary for NO synthesis, except BH4 and (2) the failure to detect NO in cytokine-stimulated untransfected U937 cells is not due to the presence of a NO-scavenging molecule within these cells nor to the destabilization of iNOS protein. DFGiNOS U937 cells represent a valuable human model to study the role of NO in immunity toward tumors and pathogens.
Resumo:
BACKGROUND: Coronary artery disease (CAD) continues to be one of the top public health burden. Perfusion cardiovascular magnetic resonance (CMR) is generally accepted to detect CAD, while data on its cost effectiveness are scarce. Therefore, the goal of the study was to compare the costs of a CMR-guided strategy vs two invasive strategies in a large CMR registry. METHODS: In 3'647 patients with suspected CAD of the EuroCMR-registry (59 centers/18 countries) costs were calculated for diagnostic examinations (CMR, X-ray coronary angiography (CXA) with/without FFR), revascularizations, and complications during a 1-year follow-up. Patients with ischemia-positive CMR underwent an invasive CXA and revascularization at the discretion of the treating physician (=CMR + CXA-strategy). In the hypothetical invasive arm, costs were calculated for an initial CXA and a FFR in vessels with ≥50 % stenoses (=CXA + FFR-strategy) and the same proportion of revascularizations and complications were applied as in the CMR + CXA-strategy. In the CXA-only strategy, costs included those for CXA and for revascularizations of all ≥50 % stenoses. To calculate the proportion of patients with ≥50 % stenoses, the stenosis-FFR relationship from the literature was used. Costs of the three strategies were determined based on a third payer perspective in 4 healthcare systems. RESULTS: Revascularizations were performed in 6.2 %, 4.5 %, and 12.9 % of all patients, patients with atypical chest pain (n = 1'786), and typical angina (n = 582), respectively; whereas complications (=all-cause death and non-fatal infarction) occurred in 1.3 %, 1.1 %, and 1.5 %, respectively. The CMR + CXA-strategy reduced costs by 14 %, 34 %, 27 %, and 24 % in the German, UK, Swiss, and US context, respectively, when compared to the CXA + FFR-strategy; and by 59 %, 52 %, 61 % and 71 %, respectively, versus the CXA-only strategy. In patients with typical angina, cost savings by CMR + CXA vs CXA + FFR were minimal in the German (2.3 %), intermediate in the US and Swiss (11.6 % and 12.8 %, respectively), and remained substantial in the UK (18.9 %) systems. Sensitivity analyses proved the robustness of results. CONCLUSIONS: A CMR + CXA-strategy for patients with suspected CAD provides substantial cost reduction compared to a hypothetical CXA + FFR-strategy in patients with low to intermediate disease prevalence. However, in the subgroup of patients with typical angina, cost savings were only minimal to moderate.
Resumo:
Case: A 11 yo girl with Marfan syndrome was referred to cardiac MR (CMR) to measure the size of her thoracic aorta. She had a typical phenotype with arachnodactyly, abnormally long arms, and was tall and slim (156 cm, 28 kg, body mass index 11,5 kg/m2). She complained of no symptoms. Cardiac auscultation revealed a prominent mid-systolic click and an end-systolic murmur at the apex. A recent echocardiogram showed a moderately dilated left ventricle with normal function and a mitral valve prolapse with moderate mitral valve regurgitation. CMR showed a dilatation of the aortic root (38 mm, Z-score 8.9) and a severe prolapse of the mitral valve with regurgitation. The ventricular cavity was moderately dilated (116 ml/m2) and its contraction was hyperdynamic (stroke volume (SV): 97 ml; LVEF 72%, with the LV volumes measured by modified Simpson method from the apex to the mitral annulus). In this patient however, the mitral prolapse was characterized by a severe backward movement of the valve toward the left atrium (LA) in systole and the dyskinetic movement of the atrioventricular plane caused a ventricularisation of a part of the LA in systole (Figure). This resulted in a significant reduction of LVEF: more than ¼ of the apparent SV was displaced backwards into the ventricularized LA volume, reducing the effective LVEF to 51% (effective SV 69ml). Moreover, by flow measurement, the SV across the ascending aorta was 30 ml (cardiac index 2.0 l/min/m2) allowing the calculation of a regurgitant fraction across the mitral valve of 56%, which was diagnostic for a severe mitral valve insufficiency. Conclusion: This case illustrates the phenomenon of a ventricularisation of the LA where the severe prolapse gives the illusion of a higher attachement of the mitral leaflets within the atrial wall. Besides the severe mitral regurgitation, this paradoxical backwards movement of the valve causes an intraventricular unloading during systole reducing the apparent LVEF of 72% to an effective LVEF of only 51%. In addition, forward flow fraction is only 22% after accounting for the regurgitant volume, as well. This combined involvement of the mitral valve could explain the discrepancy between a low output state and an apparently hyperdynamic LV contraction. Due to its ability to precisely measure flows and volumes, CMR is particularly suited to detect this phenomenon and to quantify its impact on the LV pump function.