597 resultados para Cabos elétricos
Resumo:
Ethanol, the main automotive biofuel, has its production based on the fermentation of sugars found in biological materials and on the distillation of the alcoholic media formed during the fermentative process. Stillage is the main residue from ethanol production, containing a high organic loading in addition to acidic and corrosive characteristics. Considering the available technologies to treat stillage, we highlight anaerobic digestion, which allows the reduction of the impacts associated to pollutants loading of this effluent and the generation of energy from the methane gas produced in the process. Based on the high treatment efficiency usually associated to the anaerobic process, this work aimed to assess whether anaerobic systems applied to the treatment of stillage are energetically self-sufficient. First we evaluated the energy recovery capacity in an anaerobic reactor applied to the treatment of stillage resulting from corn-to-ethanol processing. The results indicated the great influence that a correct selection of electrical equipment and their respective operating periods have on the net energy balance of the anaerobic treatment. The high energy consumption of the heater would not allow the system to achieve a positive net energy balance – the maximum energy recovery would reach only 0.68% of the consumption. However, the replacement of the mixture equipment would result in energy gains ranging from 8.5 to 967.9% of the consumption. In this work we also assessed the efficiency of methane yields for a few studies and the correlation between some parameters of the anaerobic process. With respect to the methane yield, we noted that mesophilic systems tend to be more advantageous than the thermophilic ones (efficiency of 76.45 ± 22.51% vs. 69.40 ± 30.36%). Considering the study... (Complete abstract click electronic access below)
Resumo:
One of the biggest environmental problems of today is the climate change. Experts affirm that this global warming is related to the greenhouse effect. Its causes are directly related to human activity, especially the use of fossil fuels. In this context, companies around the world are challenged to improve energy efficiency in order to reduce the environmental impact and work toward the so-called tripod of sustainable development that focuses on the social, economic and environmental aspects of a business strategy. The first step a company can make in this regard is to conduct an inventory of emissions of greenhouse gases (GHGs). The reduction of GHG emissions in a refinery can be achieved by replacing steam turbines with electric motors to drive big machines, this reduction is achieved by relieving the steam consumption for electric power available or purchased. An important aspect associated with the reduction of GHG emissions is the best performance of the Energy Intensity Index (ERI). The objective of this study was to analyze the feasibility of the blower motorization in the regenerative cycle of a fluidized catalytic cracking unit at a specific refinery. For development work, two methods were used, the initial screening and optimization scenarios with the help of software Butyl. The results indicate that after a certain cost of natural gas this substitution becomes favorable. In addition, there is a large reduction of CO2 emissions avoided by burning fuel
Resumo:
The eletrochemotherapy is a new treatment option for neoplasms that involves the application of chemotherapeutic drugs endovenously or intralesionally, associated with local severe and short duration electrical pulses. The electrical pulses promote destabilization of the cell membrane, causing transitory pore formation and facilitating the entry of chemotherapeutic agents inside the cells, increasing its cytotoxicity. This therapy allows for lower doses of chemotherapy drugs compared to conventional chemotherapy, resulting in the decrease of side effects and costs of treatment. The eletrochemotherapy has proved effective in the treatment of cancer regardless of its histological origin and location. This review aims to highlight possibilities to use this treatment in Veterinary Oncology
Resumo:
Within the concepts of sustainability, energy audit magnified its importance in managing systems in industrial plants. Can reduce waste and save energy representative, the improvement and development of thermal and electrical systems can be very attractive to business. With the focus on a boiler generating steam, the energy audit aimed to increase efficiency and eliminate energy losses of the heat engine. The boiler in question is commonly called CO boiler because most of the calorific power provided comes from this. Using a fuel gas from the catalyst regeneration process, it has featured in the boiler power generation system of the refinery. Burning a mixture of gaseous components from discarded into the atmosphere, the heat engine can generate tons of steam just as the other boilers installed. The challenge was to work with this gas mixture and obtain maximum efficiency, reduce moisture and enjoy the warmth of the heat exchange have been studied and recommended. Every project, from evaluation of the variables in the composition of fuel gas, to the using of heat exchangers and refrigeration system are suitable for evaluation and improvements
Resumo:
Wireless communications is a feature that has become indispensable for many people in the whole world. Through this feature, communication process can become much more efficient, allowing people to access information much more quickly wherever they are. The constant evolution of communication technologies allows the development of new unthinkable applications and services. This new range of possibilities brings greater mobility and efficiency for final users and also helps service providers and carriers to improve the quality of services offered by them. This study presents the principles of wireless communication and the Wi-Fi technology as well as its most modern applications, covering from the basics of computer networks to the procedures of planning a wireless network, concepts of radio frequency, antennas, patterns, regulatory agencies, network equipment, protocols and network monitoring
Resumo:
The protection and distribution systems for the electrics equipments are really important for the safety of products, process and final users, for an enterprise or even for a residence. For that, it’s necessary the utilization of low voltage switchboards for controlling the feeding of a charge, avoiding any kind of abnormality that can eventually occur. It’s necessary to pay attention in the cubicles conditions, and always verify if they are in accordance to the norms of the product, verifying also any kind of physical damage for the operator and/or users. In this line, the present graduation work analyses the low voltage switchboards in the college, checking if they are attending the actual standards, suggesting some improvements and later making a simulation of the creation of a new panel that reach all the needing in substitution of this actual, through the software Simaris. Using the research and lecture of norms and regulations for verifying the problems, this way we could register the greatest acting failures. These actions are made for becoming aware to the university about the danger in using electrics equipments without a minimum degree of protection, allowed by the law, and attempting to the urgency in changing this fails
Resumo:
This study aims to prove the economic feasibility of the installation of mechanical compression chillers on plastic injection molding machines in order to reduce the production cycle time of toothbrush cables in a specific case study. This evidence was confirmed by the comparative analysis of the system replaced and the new system installed. The old system had only one closed loop cooling tower which pumped chilled water to the injection molds, and the new system has the same tower sending cold water to the condensers of individual chillers installed on each injection machine. We conducted an analysis of energy efficiency in each system, showing that in terms of thermal efficiency virtually nothing has changed, but in terms of electricity demand the new system consumes 60.3 kW more. We conducted an analysis of machine productivity for both systems, showing a much higher productivity of the new system due to reduced cycle times caused by the presence of chillers and their greater cooling capacities. Equipped with data such as electricity rates, increases in operating costs and initial investments, the increase in consumption and demand of electricity plus the cycle time reduction were also calculated over so the simple payback 1 year and 2 months was reached
Resumo:
Are presented on this paper, concepts of corrective, preventive and predictive maintenances, following the prerequisites for planning and implementation of a maintenance plan. You also find the theoretical introduction of some measurement instruments accompanied by the necessary and recommended activities during routine maintenances of the electrical equipments in a building installation. Using case study, it is possible to assess a real maintenance plan applied to two occupied floors in a financial institution. The developing of a case study consolidates the effectiveness of the present concepts on this theoretical introduction and shows that the current maintenance plan can be improved in order to obtain better results on company productivity and reliability of equipments. As a conclusion, we can notice the importance of a solid maintenance plan and the need of including this theme on the graduation in Electrical Engineering
Comissionamento de turbinas hidráulicas: ensaios de faixa operativa, índex, test e rejeição de carga
Resumo:
With growing electricty demand, the importance of generation through hydropower, a renewable energy source, it’s of great importance. This demand derives from the country’s growth, as well as events that will occur in the coming years. The commission has a crucial role before the entry into operation of hydroelectric plant, sice, ensures a good operation of hydraulic and electrical systems, as well as the safety of the installation. This paper is a case study, commissioning in a PCH in especially the most important tests, such as range operation, índex tes and load rejection. In these trials we can get a Idea of the actual behavior of the unit, as well as future operation maneuvers, and evidence of real efficiency
Resumo:
Burns are frequent accidents, and they are among the major causes of morbidity and mortality in our society. In Brazil, statistical data on such lesions are relatively scarce, and they are concentrated in a few treatment centers. Data on such accidents allow for specific care to be timely and properly taken in order to provide patients with a better prognosis, in addition to enabling the development of prevention programs as well as fire-prevention safety laws. To characterize the epidemiological profile of users at the Burn Treatment Unit of Bauru State Hospital. Collection of epidemiological data through the e-pront system and from charts of burned inpatients from April 2005 to April 2010. During the studied period, 906 hospitalizations of burned patients occurred, with an annual average of 181.2 individuals. Their mean age was 28.4 years, with a predominance of males. The mean hospitalization period was of 27.6 days, with a median of 16 days and a maximum of 216 days; 14.7% developed to death, with the highest mortality rate in the first two weeks of hospitalization. Second-degree burns were the most frequent; 36.8% of the patients burned less than 10% of their body surface, and there was a gradual frequency reduction when a larger burned surface was taken into account; the greater the affected areas, the higher the number of deaths; 91% resulted from thermal agents, 6% from electric and 2% from chemical agents; scalding was the major cause among all agents, followed by alcohol associated with fire and direct flame. The major area affected areas were the upper limbs. The study shows the need for educational and preventive measures, particularly for the young adult population, by means of educational programs and prevention campaigns
Resumo:
With the increasing demand for electricity, the retraining of transmission lines is necessary despite environmental restrictions and crossings in densely populated areas to build new transmission and distribution lines. Solution is reuse the existent cables, replacing the old conductor cables for new cables with higher capacity power transmission, and control of sag installed. The increasing demand for electrical power has increased the electric current on the wires and therefore, it must bear out temperatures of 150°C or more, without the risk of the increasing sag beyond the established limits. In the case of long crossings or densely populated areas, sag is due to high weight of the cable on clearance. The cable type determines the weight, sag, height and the towers dimensions, which are the items that most influence the investment of the transmission line. Hence, to reduce both cost of investment and maintenance of the line, the use of a lighter cable can reduce both number and the height of the towers, with financial return on short and long term. Therefore, in order to increase the amount of transmitted energy and reduce the number of built towers and sag, is recommended in the current work substitute the current core material (steel or aluminium) for alternatives alloys or new materials, in this case a composite, which has low density, elevated stiffness (elasticity module), thus apply the pultruded carbon fiber with epoxy resin as matrix systems and perform the study of the kinetics of degradation by thermogravimetric analysis (TGA), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC), according to their respective standards
Resumo:
In the industrial environment the challenge is use better the productive resources: people and machine. The following work has the main goal improve the efficient losses analysis in the stator bar’s production bottleneck equipment situated in the Electric generator’s factory. The action research involved Theory of Constraints on the restriction system identification and developed the data collection framework by losses typology for indicator measurement. The research showed the data collection standardization importance to obtain reliable data and strategic efficiency indicator to optimize equipments. Besides of this, OEE and TEEP indicator demonstrated efficiency results to analyze the actual efficiency when the machine works and the increase capacity opportunity to treat the hide costs in the organization following the continuous improvement
Resumo:
Electrical installations in industries involving high currents and voltages considered. On the other side is the common appearance of electrical failures, caused by human error, defects in electrical equipment or electrical installation aging itself. These failures are varied, those with the highest rate of occurrence and cause much damage to electrical installations, are overcurrent and overvoltage. Therefore there is a need to project a system that can detect and minimize possible effects caused by faults in electrical installations industries. Protection systems in electric industries emerge as an alternative to control especially voltage and current magnitudes. Engineered based on the functions of the relays, protection systems are an indispensable tool for any industrial substation. But the project of such systems becomes increasingly more complex, due to technological development. Electrical equipment not develop at the same speed that the protective devices (relays), making it indispensable knowledge of integration of technologies
Resumo:
Therebar of aluminum 1350 AA produced by CBA are used inthe manufacture of wires and cables for electric power transmission, which marketshows increasingly favorableto aluminum due to itslow densityand high electrical conductivity, but to ensure that this materialmeets all specifications of projectsfor electricity transmission, it must have homogeneity in the chemicaland mechanicalproperties.One of the points of improvement in the process of rod production isreducing the high variation of the limitof tensile strengthalong the coils, therefore, this work seeks a better understanding of the factors that significantly influence the mechanical properties of rebar, specifically assessing the influence oftemperatureat the output of the coils, which can cause a recovery effect on the material andif thereare relevantdifferences between the two modes of rebar production: auto and manual.Samples of six coils have been specifically produced forthis study, which weresubsequently subjected to different annealing temperatures for one hour and ten minutes, similar to what occurs in the output of the coil from the machine. The tensile tests showed that aluminum 1350 AA is significantly influenced by temperature, whose behavior was very similar to that presented in the literature. It was found that the phenomenon of recovery occurred more significantly at high temperatures. Through the optical electron microscope Zeiss, 18 surface maps were made with 100x magnification for each sample in different conditions and the images were analyzed using entropy and fractal dimension, aiming to relate the condition of surface hardening on mechanical property of the samples in that condition. The results showed that these methods can be applied, provided they do not have any kind of imperfection on the surface, once they can influence the results. The study concluded that a more efficient cooling is required in ... (Complete abstract click electronic access below)
Resumo:
This paper proposes a mechanical device to adapt a simple model of hospital bed used in the Emergency Department at Santa Casa of Guaratinguetá, allowing the bed’s height adjustment with electromechanical drive. This adaptation aims to introduce improvements in the routine work of nurses and reduce ergonomic problems stemming from repetitive strain during the transfer of patients to stretchers and wheelchairs, as well as providing more comfort to the bedridden patient. The device is mainly composed of: an electric induction motor used to drive the engine, a steel spindle with square thread, which allows axial displacement of the bed, a transmission system with pulleys and belt, which transmits power supplied by the motor to the spindle. The mechanism allows the height of the bed is regulated between 400 and 800 mm. The estimated implementation cost of this proposal is lower than the acquisition cost of a commercial hospital bed with the same features, which confirms the feasibility of the proposed solution