944 resultados para CARDIOVASCULAR SYSTEM


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose of review Heart failure and diabetes mellitus are frequently associated, and diabetes appears to potentiate the clinical presentation of heart failure related to other causes. The purpose of this review is to examine recent advances in the application of tissue Doppler imaging for the assessment of diabetic heart disease. Recent findings Recent studies have documented that both myocardial systolic and diastolic abnormalities can be identified in apparently healthy patients with diabetes and no overt cardiac dysfunction. Interestingly, these are disturbances of longitudinal function, with compensatory increases of radial function-suggesting primary involvement of the subendocardium, which is a hallmark of myocardial ischemia. Despite this, there is limited evidence that diabetic microangiopathy is responsible-with reduced myocardial blood volume rather than reduced resting flow, and at least some evidence suggesting a normal increment of tissue velocity with stress. Finally, a few correlative studies have shown association of diabetic myocardial disease with poor glycemic control, while angiotensin converting enzyme inhibition may be protective. Summary Tissue Doppler imaging (and the related technique of strain rate imaging) appears to be extremely effective for the identification of subclinical LV dysfunction in diabetic patients It is hoped that the recognition of this condition will prompt specific therapy to prevent the development of overt LV dysfunction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The extent of abnormality in patients with positive do-butamine echocardiography (DE) is predictive of risk, but the wall motion score (WMS) has low concordance among observers. We sought whether quantifying the extent of abnormal wall motion using tissue Doppler (TD) could guide risk assessment in patients with abnormal DE in 576 patients with known or suspected coronary artery disease; standard DE was combined with color TD imaging at peak dose. WMS was assessed by an expert observer and studies were identified as abnormal in the presence of 2:1 segments with resting or stress-induced wall motion abnormalities. Patients with abnormal DE had peak systolic velocity measured in each segment. Tissue tracking was used to measure myocardial displacement. Follow-up for death or infarction was per-formed after. 16 +/- 12 months. Of 251 patients with abnormal DE, 22 patients died (20 from cardiac causes) and 7 had nonfatal myocardial infarctionis. The average WMS in patients with events was 1.8 +/- 0.5, compared with 1.7 +/- 0.5 in patients without events (p = NS). The average systolic velocity in patients with events was 4.9 +/- 1.7 cm/s and 6.4 +/- 6.5 cm/s in the patients without events (p <0.001). The average tissue tracking in patients with events was 4.5 +/- 1.5 mm and was significant. (5.7 +/- 3.1 mm),in those,without events (p <0.001). Thus, TD is an alternative to WMS for quantifying the total extent of abnormal left ventricular function-at DE, and appears to be superior for predicting adverse outcomes. (C) 2004 by Excerpta Medica, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Serotonin (5-hydroxytryptamine, 5-HT) increases contractile force and elicits arrhythmias through 5-HT4 receptors in porcine and human atrium, but its ventricular effects are unknown. We now report functional 5-HT4 receptors in porcine and human ventricle. 5-HT4 mRNA levels were determined in porcine and human ventricles and contractility studied in ventricular trabeculae. Cyclic AMP-dependent protein kinase (PKA) activity was measured in porcine ventricle. Porcine and human ventricles expressed 5-HT4 receptor mRNA. Ventricular 5-HT4(b) mRNA was increased by four times in 20 failing human hearts compared with five donor hearts. 5-HT increased contractile force maximally by 16% (EC50=890 nM) and PKA activity by 20% of the effects of (-)-isoproterenol (200 muM) in ventricular trabeculae from new-born piglets in the presence of the phosphodiesterase-inhibitor 3-isobutyl-1-methylxanthine. In ventricular trabeculae from adult pigs (3-isobutyl-1-methylxanthine present) 5-HT increased force by 32% (EC50=60 nM) and PKA activity by 39% of (-)-iso-proterenol. In right and left ventricular trabeculae from failing hearts, exposed to modified Krebs solution, 5-HT produced variable increases in contractile force in right ventricular trabeculae from 4 out of 6 hearts and in left ventricular trabeculae from 3 out of 3 hearts- range 1-39% of (-)-isoproterenol, average 8%. In 11 left ventricular trabeculae from the failing hearts of four beta-blocker-treated patients, pre-exposed to a relaxant solution with 0.5 mM Ca2+ and 1.2 mM Mg2+ followed by a switch to 2.5 mM Ca2+ and 1 mM Mg2+, 5-HT (1-100 muM, 3-isobutyl-1-melhylxanthine present) consistently increased contractile force and hastened relaxation by 46% and 25% of (-)-isoproterenol respectively. 5-HT caused arrhythmias in three trabeculae from 3 out of I I patients. In the absence of phosphodiesterase inhibitor, 5-HT increased force in two trabeculae, but not in another six trabeculae from 4 patients. All 5-HT responses were blocked by 5-HT4 receptor antagonists. We conclude that phosphodiesterase inhibition uncovers functional ventricular 5-HT4 receptors, coupled to a PKA pathway, through which 5-HT enhances contractility, hastens relaxation and can potentially cause arrhythmias.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Laryngeal and tongue function was assessed in 28 patients to evaluate the presence, nature, and resolution of superior recurrent laryngeal and hypoglossal nerve damage resulting from standard open primary carotid endarterectomy (CEA). Methods. The laryngeal and tongue function in 28 patients who underwent CEA were examined prospectively with various physiologic (Aerophone II, laryngograph, tongue transducer), acoustic (Multi-Dimensional Voice Program), and perceptual speech assessments. Measures were obtained from all participants preoperatively, and at 2 weeks and at 3 months postoperatively. Results. The perceptual speech assessment indicated that the vocal quality of roughness was significantly more apparent at the 2-week postoperative assessment than preoperatively. However, by the 3-month postoperative assessment these values had returned to near preoperative levels, with no significant difference detected between preoperative and 3-month postoperative levels or between 2-week and 3-month postoperative levels. Both the instrumental assessments of laryngeal function and the acoustic assessment of vocal quality failed to identify any significant difference on any measure across the three assessment periods. Similarly, no significant impairment in tongue strength, endurance, or rate of repetitive tongue movements was detected at instrumental assessment of tongue function. Conclusions: No permanent changes to vocal or tongue function occurred in this group of participants after primary CEA. The lack of any significant long-term laryngeal or tongue dysfunction in this group suggests that the standard open CEA procedure is not associated with high rates of superior recurrent and hypoglossal nerve dysfunction, as previously believed.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Remote access to pediatric cardiology diagnostic services is enabled by real-time transmission of echocardiographic images. Several transmission bandwidths have been used but there has been little analysis of image quality provided by different bandwidths. We designed a study of the quality of transmitted images at various bandwidths. Methods: Two echocardiographers viewed randomly a series of 13 recorded pediatric echocardiographic images either directly or after transmission using 1 of 4 bandwidths: 256; 384; 512; or 768 kbps. An image clarity scoring scale was used to assess image quality of cardiac structures. Results: Measurable differences were found in image quality with different transmission bandwidths; 512 kbps was the minimum for consistently clear imaging of all cardiac structures examined. Conclusion: Bandwidth greater than 512 kbps confers sharper images subjectively although this could not be quantified by our methods.

Relevância:

60.00% 60.00%

Publicador: