950 resultados para CADMIUM TELLURIDE DETECTORS
Resumo:
The general purpose of this study is to investigate the degree of heavy metal accumulation in hard and soft tissue of sea urchin, and determining these tissues as the most suitable bioindicator for lead and cadmium in the environment of the sampling stations. The way of doing this assessment was MOOPAM. Samples were prepared and classified according to sea urchin organ (soft tissue, hard tissue, Tube feet, Test, Lantern Structure and spines) and then lead and cadmium were measured in them. Result of this study shows that hard tissue is a better index of lead and cadmium than soft tissue. The result of bioaccumulation of lead in the related tissue was found to be in the following order: Soft tissue=21, hard tissue=28.1, Test=20.8, Lantern Structure=20.5 and spines=23.9. The result of bioaccumulation of cadmium in the related tissue was found to be in the following order: Soft tissue=9. 7, hard tissue=5.01, Test=4.2, Lantern Structure=4.06 and spines=5.53.
Resumo:
The phytoextraction process implies the use of plants to promote the elimination of metal contaminants in the soil. In fact, metal-accumulating plants are planted or transplanted in metal-contaminated soil and cultivated in accordance with established agricultural practices. The objective of the present study was to evaluate the productivity and Cd phytoextraction capacity of white lupine ( Lupinus albus L.) and narrow-leafed lupine ( Lupinus angustifolius L.), as well as the effect on residual Cd concentration in the soil. Both species of lupines were grown at three CdCl2 rates (0, 1, and 2 mg kg-1), under three agroclimatic conditions in Chile in 2013. In the arid zone (Pan de Azúcar, 73 mm precipitation), narrow-leafed lupine production was significantly (P < 0.05) higher than white lupine (4.55 vs. 3.26 Mg DM ha-1, respectively). In locations with higher precipitation (Santa Rosa, 670 mm; Carillanca, 880 mm), narrow-leafed lupine DM production was slightly higher than in Pan de Azúcar, but white lupine was approximately three times higher. Total plant Cd concentrations in white and narrow-leafed lupine increased as Cd rates increased in the three environments, but they were much higher in narrow-leafed lupine than white lupine; 150%, 58%, and 344% higher in Pan de Azúcar, Santa Rosa, and Carillanca, respectively. Cadmium uptake (g Cd ha-1) and apparent recovery were also higher (P < 0.05) in narrow-leafed lupine in two environments (Pan de Azúcar and Carillanca). These results suggest that narrow-leafed lupine present higher potential as phytoremediation species than white lupine.
Resumo:
Among the toxic elements, Cd has received considerable attention in view of its association with a number of human health problems. The objectives of this study were to evaluate the Cd availability and accumulation in soil, transfer rate and toxicity in lettuce and rice plants grown in a Cd-contaminated Typic Hapludox. Two simultaneous greenhouse experiments with lettuce and rice test plants were conducted in a randomized complete block design with four replications. The treatments consisted of four Cd rates (CdCl2), 0.0; 1.3; 3.0 and 6.0 mg kg(-1), based on the guidelines recommended by the Environmental Agency of the State of São Paulo, Brazil (Cetesb). Higher Cd rates increased extractable Cd (using Mehlich-3, Mehlich-1 and DTPA chemical extractants) and decreased lettuce and rice dry matter yields. However, no visual toxicity symptoms were observed in plants. Mehlich-1, Mehlich-3 and DTPA extractants were effective in predicting soil Cd availability as well as the Cd concentration and accumulation in plant parts. Cadmium concentration in rice remained below the threshold for human consumption established by Brazilian legislation. on the other hand, lettuce Cd concentration in edible parts exceeded the acceptable limit.
Resumo:
Tese de Doutoramento, Ciências do Mar, da Terra e do Ambiente, Ramo: Ciências e Tecnologias do Ambiente, Especialização em Ecotoxicologia, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2016
Resumo:
2014
Resumo:
2016
Resumo:
Testing of summing electronics and VDC A/D Cards was performed to assure proper functioning and operation within defined parameters. In both the summing modules and the VDC A/D cards, testing for minimum threshold voltage for each channel and crosstalk between neighboring channels was performed. Additionally, the modules were installed in Hall A with input signals from shower detectors arranged to establish a trigger by summing signals together with the use of tested modules. Testing involved utilizing a pulser to mimic PMT signals, a discriminator, an attenuator, a scaler, a level translator, an oscilloscope, a high voltage power supply, and a special apparatus used to power and send signal to the A/D cards. After testing, modules were obtained that meet necessary criteria for use in the APEX experiment, and the A/D cards obtained were determined to have adequate specifications for their utilization, with specific results included in the appendix.
Resumo:
OBJECTIVES: Most studies reporting evidence of adverse effects of lead and cadmium on the ability to balance have been conducted in high-exposure groups or have included adults. The effects of prenatal exposure have not been well studied, nor have the effects in children been directly studied. The aim of the study was to identify the associations of lead (in utero and in childhood) and cadmium (in utero) exposure with the ability to balance in children aged 7 and 10 years. DESIGN: Prospective birth cohort study. PARTICIPANTS: Maternal blood lead (n=4285) and cadmium (n=4286) levels were measured by inductively coupled plasma mass spectrometry in women enrolled in the Avon Longitudinal Study of Parents and Children (ALSPAC) during pregnancy. Child lead levels were measured in a subsample of 582 of ALSPAC children at age 30 months. MAIN OUTCOME MEASURES: Children completed a heel-to-toe walking test at 7 years. At 10 years, the children underwent clinical tests of static and dynamic balance. Statistical analysis using SPSS V.19 included logistic regression modelling, comparing categories of ≥ 5 vs <5 µg/dL for lead, and ≥ 1 vs <1 µg/L for cadmium. RESULTS: Balance at age 7 years was not associated with elevated in utero lead or cadmium exposure (adjusted OR for balance dysfunction: Pb 1.01 (95% CI 0.95 to 1.01), n=1732; Cd 0.95 (0.77 to 1.20), n=1734), or with elevated child blood lead level at age 30 months (adjusted OR 0.98 (0.92 to 1.05), n=354). Similarly, neither measures of static nor dynamic balance at age 10 years were associated with in utero lead or cadmium exposure, or child lead level. CONCLUSIONS: These findings do not provide any evidence of an association of prenatal exposure to lead or cadmium, or lead levels in childhood, on balance ability in children. Confirmation in other cohorts is needed.
Resumo:
Ionizing radiations are important tools employed every day in the modern society. For example, in medicine they are routinely used for diagnostic and therapy. The large variety of applications leads to the need of novel, more efficient, low-cost ionizing radiation detectors with new functionalities. Personal dosimetry would benefit from wearable detectors able to conform to the body surfaces. Traditional semiconductors used for ionizing radiation direct detectors offer high performance but they are intrinsically stiff, brittle and require high voltages to operate. Hybrid lead-halide perovskites emerged recently as a novel class of materials for ionizing radiation detection. They combine high absorption coefficient, solution processability and high charge transport capability, enabling efficient and low-cost detection. The deposition from solution allows the fabrication of thin-film flexible devices. In this thesis, I studied the detection properties of different types of hybrid perovskites, deposited from solution in thin-film form, and tested under X-rays, gamma-rays and protons beams. I developed the first ultraflexible X-ray detector with exceptional conformability. The effect of coupling organic layers with perovskites was studied at the nanoscale giving a direct demonstration of trap passivation effect at the grain boundaries. Different perovskite formulations were deposited and tested to improve the film stability. I report about the longest aging studies on perovskite X-ray detectors showing that the addition of starch in the precursors’ solution can improve the stability in time with only a 7% decrease in sensitivity after 630 days of storage in ambient conditions. 2D perovskites were also explored as direct detector for X-rays and gamma-rays. Detection of 511 keV photons by a thin-film device is here demonstrated and was validated for monitoring a radiotracer injection. At last, a new approach has been used: a 2D/3Dmixed perovskite thin-film demonstrated to reliably detect 5 MeV protons, envisioning wearable dose monitoring during proton/hadron therapy treatments.
Resumo:
From 2010, the Proton Radius has become one of the most interest value to determine. The first proof of not complete understanding of its internal structure was the measurement of the Lamb Shift using the muonic hydrogen, leading to a value 7σ lower. A new road so was open and the Proton Radius Puzzle epoch begun. FAMU Experiment is a project that tries to give an answer to this Puzzle implementing high precision experimental apparatus. The work of this thesis is based on the study, construction and first characterization of a new detection system. Thanks to the previous experiments and simulations, this apparatus is composed by 17 detectors positioned on a semicircular crown with the related electronic circuit. The detectors' characterization is based on the use of a LabView program controlling a digital potentiometer and on other two analog potentiometers, all three used to set the amplitude of each detector to a predefined value, around 1.2 V, set on the oscilloscope by which is possible to observe the signal. This is the requirement in order to have, in the final measurement, a single high peak given by the sum of all the signals coming from the detectors. Each signal has been acquired for almost half of an hour, but the entire circuit has been maintained active for more time to observe its capacity to work for longer periods. The principal results of this thesis are given by the spectra of 12 detectors and the corresponding values of Voltages, FWHM and Resolution. The outcomes of the acquisitions show also another expected behavior: the strong dependence of the detectors from the temperature, demonstrating that an its change causes fluctuations in the signal. In turn, these fluctuations will affect the spectrum, resulting in a shifting of the curve and a lower Resolution. On the other hand, a measurement performed in stable conditions will lead to accordance between the nominal and experimental measurements, as for the detectors 10, 11 and 12 of our system.
Resumo:
The corpuscular model describes black holes as leaky bound states of gravitons. To account for the role of matter, a coherent state is built and a semiclassical description is given to the gravitational field by connecting the classical source with the quantum state for gravitons. The properties of this state can be analysed with the help of an Unruh-DeWitt detector, coupled to the quantum state of the system. The presence of a detector in general regularises the usual diverging behaviour of the field in the deep ultraviolet region, and will allow us to probe the coherent state structure and the graviton emission. In particular, a Newtonian analogue of the Unruh effect will be discussed and the coherent state will be modified to properly account for the spherical symmetry of the potential at the level of the quantum state. This correction will ensure that vacuum contributions responsible for the Unruh thermal spectrum are present in a coherent state emission process.