945 resultados para Anaerobic Threshold


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We employ the time-dependent R-matrix (TDRM) method to calculate anisotropy parameters for positive and negative sidebands of selected harmonics generated by two-color two-photon above-threshold ionization of argon. We consider odd harmonics of an 800-nm field ranging from the 13th to 19th harmonic, overlapped by a fundamental 800-nm IR field. The anisotropy parameters obtained using the TDRM method are compared with those obtained using a second-order perturbation theory with a model potential approach and a soft photon approximation approach. Where available, a comparison is also made to published experimental results. All three theoretical approaches provide similar values for anisotropy parameters. The TDRM approach obtains values that are closest to published experimental values. At high photon energies, the differences between each of the theoretical methods become less significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The environmental quality of land can be assessed by calculating relevant threshold values, which differentiate between concentrations of elements resulting from geogenic and diffuse anthropogenic sources and concentrations generated by point sources of elements. A simple process allowing the calculation of these typical threshold values (TTVs) was applied across a region of highly complex geology (Northern Ireland) to six elements of interest; arsenic, chromium, copper, lead, nickel and vanadium. Three methods for identifying domains (areas where a readily identifiable factor can be shown to control the concentration of an element) were used: k-means cluster analysis, boxplots and empirical cumulative distribution functions (ECDF). The ECDF method was most efficient at determining areas of both elevated and reduced concentrations and was used to identify domains in this investigation. Two statistical methods for calculating normal background concentrations (NBCs) and upper limits of geochemical baseline variation (ULBLs), currently used in conjunction with legislative regimes in the UK and Finland respectively, were applied within each domain. The NBC methodology was constructed to run within a specific legislative framework, and its use on this soil geochemical data set was influenced by the presence of skewed distributions and outliers. In contrast, the ULBL methodology was found to calculate more appropriate TTVs that were generally more conservative than the NBCs. TTVs indicate what a "typical" concentration of an element would be within a defined geographical area and should be considered alongside the risk that each of the elements pose in these areas to determine potential risk to receptors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss-of-mains protection is an important component of the protection systems of embedded generation. The role of loss-of-mains is to disconnect the embedded generator from the utility grid in the event that connection to utility dispatched generation is lost. This is necessary for a number of reasons, including the safety of personnel during fault restoration and the protection of plant against out-of-synchronism reclosure to the mains supply. The incumbent methods of loss-of-mains protection were designed when the installed capacity of embedded generation was low, and known problems with nuisance tripping of the devices were considered acceptable because of the insignificant consequence to system operation. With the dramatic increase in the installed capacity of embedded generation over the last decade, the limitations of current islanding detection methods are no longer acceptable. This study describes a new method of loss-of-mains protection based on phasor measurement unit (PMU) technology, specifically using a low cost PMU device of the authors' design which has been developed for distribution network applications. The proposed method addresses the limitations of the incumbent methods, providing a solution that is free of nuisance tripping and has a zero non-detection zone. This system has been tested experimentally and is shown to be practical, feasible and effective. Threshold settings for the new method are recommended based on data acquired from both the Great Britain and Ireland power systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anaerobic bacteria have been identified in abundance in the airways of cystic fibrosis (CF) subjects. The impact their presence and abundance has on lung function and inflammation is unclear. The aim of this study was to investigate the relationship between the colony count of aerobic and anaerobic bacteria, lung clearance index (LCI), spirometry and C-Reactive Protein (CRP) in patients with CF. Sputum and blood were collected from CF patients at a single cross-sectional visit when clinically stable. Community composition and bacterial colony counts were analysed using extended aerobic and anaerobic culture. Patients completed spirometry and a multiple breath washout (MBW) test to obtain LCI. An inverse correlation between colony count of aerobic bacteria (n = 41, r = -0.35; p = 0.02), anaerobic bacteria (n = 41, r = -0.44, p = 0.004) and LCI was observed. There was an inverse correlation between colony count of anaerobic bacteria and CRP (n = 25, r = -0.44, p = 0.03) only. The results of this study demonstrate that a lower colony count of aerobic and anaerobic bacteria correlated with a worse LCI. A lower colony count of anaerobic bacteria also correlated with higher CRP levels. These results indicate that lower abundance of aerobic and anaerobic bacteria may reflect microbiota disruption and disease progression in the CF lung.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perennial ryegrass was subjected to a range of anaerobic treatments. The distribution of C within the plant was determined by pulse labelling the shoots with 14C-CO2. A 5 h anaerobic period before pulse labelling reduced by 2.5-10 times the 14C remaining in the plants and released into the soil. The distribution of the 14C within the plant was also affected by anaerobiosis. Short periods of anaerobiosis (5 or 10 h) led to increased root-soil 14C respiration (monitored for 7 days). A longer period of anaerobiosis (48 h) initially inhibited root-soil 14C respiration, but when aerobiosis was restored. 57% of the total 14C fixed by the plant was respired by the roots-soil during the following 7 days compared to 19% for the aerobic control. There was a two-thirds reduction in the percentage C retained by the plants stressed for the 48 h compared to the aerobic control. At harvest, all anaerobic treatments were associated with more 14C remaining in the soil as a proportion of the total 14C fixed by the plant compared to the aerobic control. © 1990.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most cost effective methods of pollution remediation is through natural attenuation where the resident microorganisms are responsible for the breakdown of pollutants (Dou et al. 2008). Other forms of bioremediation - such as analogue enrichment, composting and bio-venting - also use the microbes already present in a contaminated site to enhance the remediation process. In order for these approaches to be successful, in an industrial setting, some form of monitoring needs to take place enabling conclusions to be drawn about the degradation processes occurring. In this review we look at some key molecular biology techniques that have the potential to act as a monitoring tool for industries dealing with contaminated land. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two hundred seven vitamin A-deficient southern Indian children aged 1-7 y (mean age: 56.9 mo) underwent testing of dark-adapted visual and pupillary thresholds in their village setting according to a previously reported protocol. One hundred thirty (62.8%) of the children also underwent serum retinol testing, and 178 (86.0%) participated in a randomized, placebo-controlled vitamin A dosing trial with pre- and postdose testing of dark-adaptation threshold. Most subjects (184 of 207, 88.9%) were able to complete pupillary testing, an objective sign requiring minimal cooperation, including a high proportion of the youngest children (72.2% of subjects aged 2 y). The proportion of children completing visual threshold testing, which requires greater understanding and cooperation, was significantly smaller than that able to complete pupillary testing (131 of 207, 63.3%; P < 0.0001, chi square). At baseline (predosing), the mean serum retinol concentration declined in linear fashion with a higher pupillary threshold (0.73 mumol/L with a score < or = 4; 0.47 mumol/L with a score > or = 8; P < 0.01). The mean pupillary threshold for these highly vitamin A-deficient Indian children (-0.622 log cd/m2) was significantly higher than that for 136 more moderately deficient Indonesian children (-0.985 log cd/m2; P < 0.001, two-sample t test) and 56 normal American children (-1.335 log cd/m2; P < 0.0001, two-sample t test). The improvement in pupillary dark-adaptation testing was not significant for children receiving vitamin A or placebo, though there was a nonsignificant trend toward greater improvement in children receiving vitamin A (P = 0.2, two-sample t test). Pupillary threshold testing represents a new, noninvasive, practical, and seemingly valid approach to assessing the vitamin A status of a moderately to severely deficient preschool population.