853 resultados para 3D Geometry
Resumo:
BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.
Resumo:
Se presenta el mapa gravimétrico de la Cubeta Alavesa, donde se pueden localizar de forma clara los diapiros salinos aflorantes en la misma, y también otras estructuras también diapíricas situadas a mayor profundidad. Se ha modelizado en 3D, mediante dos técnicas gravimétricas diferentes, el diapiro de Salinas de Añana. El cual presenta una gran extensión en superficie pero que en cambio no se proyecta de la misma manera en profundidad, habiéndose detectado la presencia de una extensión lateral u overghang hacia el SW.
Resumo:
Tämä diplomityö on selvitystyö mittakuvien ja kolmiulotteisten CAD-mallien tuottamisesta. Mittakuvat ja 3D-CAD-mallit halutaan Neles-tuotemerkin omaaville tuotteille. Olennaisena osana työssä on tuotetiedonhallintajärjestelmä AtonPDM, koska mittakuvia ja malleja toivottaisiin hallittavan AtonPDM-järjestelmällä. Työ tehdään Metso Automationin (MA) Flow Control (FC) –liiketoimintalinjalle. Nykyiset mittakuvat aiheuttavat ongelmia sekä MA:ssa että asiakkaille. MA:ssa mittakuvien tekeminen kestää kauemmin kuin asiakas toivoisi. Nykyisen mittakuvaohjelmiston riittämättömät ominaisuudet aiheuttavat lisätyötä mittakuvien valmistuksessa. Asiakkaille mittakuvien viivästyminen on suunnittelua hidastava tekijä. Mittakuvissa olevat virheet ja puutteet vaikeuttavat asiakkaan suunnittelutyötä ja saattavat päästä läpi tarkatuksien myös loppusuunnitelmiin, jolloin seurauksena voi olla rahallisia menetyksiä. Tämän päivän putkistosuunnittelu hoidetaan suurimmaksi osaksi 3D-CADohjelmistoilla. Suunnittelua helpotetaan ja nopeutetaan valmiilla komponenttien 3Dmalleilla, joihin on liitetty tuotetietoa. Työssä on haastateltu MA:n henkilökuntaa, CAD-järjestelmien toimittajia ja asiakkaita. Haastattelut ovat työn tärkein tiedonlähde. Teoriatietoa on selvitetty kirjoista, lehdistä ja internetistä. Teoriaosiossa käydään läpi tuotetiedonhallinta (Product Data Management, PDM), tietokanta ja parametrinen mallintaminen. Työn lopputuloksena on pyritty saamaan kuvaus siitä miten tuotetaan 3D-CAD-mallit ja mittakuvat Neles-tuotteista käyttäen tiedonlähteenä AtonPDM:ää ja millaisia 3Dmallien ja mittakuvien tulee olla. Malleja ja mittakuvia tuottavaan järjestelmään on etsitty ratkaisuja CAD-ohjelmistoista. Ratkaisuja on verrattu keskenään ominaisuuksien, joustavuuden ja AtonPDM yhteensopivuuden perusteella.
Resumo:
Three-dimensional reconstruction of reservoir analogues can be improved combining data from different geophysical methods. Ground Penetrating Radar (GPR) and Electrical Resistivity Tomography (ERT) data are valuable tools, since they provide subsurface information from internal architecture and facies distribution of sedimentary rock bodies, enabling the upgrading of depositional models and heterogeneity reconstruction. The Lower Eocene Roda Sandstone is a well-known deltaic complex widely studied as a reservoir analogue that displays a series of sandstone wedges with a general NE to SW progradational trend. To provide a better understanding of internal heterogeneity of a 10m-thick progradational delta-front sandstone unit, 3D GPR data were acquired. In addition, common midpoints (CMP) to measure the sandstone subsoil velocity, test profiles with different frequency antennas (25, 50 and 100MHz) and topographic data for subsequent correction in the geophysical data were also obtained. Three ERT profiles were also acquired to further constrain GPR analysis. These geophysical results illustrate the geometry of reservoir analogue heterogeneities both depositional and diagenetic in nature, improving and complementing previous outcrop-derived data. GPR interpretation using radar stratigraphy principles and attributes analysis provided: 1)tridimensional geometry of major stratigraphic surfaces that define four units in the GPR Prism, 2) image the internal architecture of the units and their statistical study of azimuth and dips, useful for a quick determination of paleocurrent directions. These results were used to define the depositional architecture of the progradational sandbody that shows an arrangement in very-high-frequency sequences characterized by clockwise paleocurrent variations and decrease of the sedimentary flow, similar to those observed at a greater scale in the same system. This high-frequency sequential arrangement has been attributed to the autocyclic dynamics of a supply-dominated delta- front where fluvial and tidal currents are in competition. The resistivity models enhanced the viewing of reservoir quality associated with cement distribution caused by depositional and early diagenetic processes related to the development of transgressive and regressive systems tracts in igh-frequency sequences.
Resumo:
In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.
Resumo:
OBJETIVO: Reportar resultados de tratamentos do câncer de próstata com radioterapia conformada 3D realizados em uma única instituição. MATERIAIS E MÉTODOS: De julho de 1997 a janeiro de 2002, 285 pacientes consecutivos com câncer de próstata foram submetidos a radioterapia conformada 3D com dose mediana de 7.920 cGy na próstata e analisados retrospectivamente. A distribuição segundo o grupo de risco foi a seguinte: baixo risco - 95 (33,7%); risco intermediário - 66 (23,4%); alto risco - 121 (42,9%) pacientes. RESULTADOS: Em seguimento mediano de 53,6 meses (3,6-95,3 meses), sobrevidas atuariais global, causa específica, livre de metástases a distância e livre de recidiva bioquímica em cinco anos foram de 85,1%, 97,0%, 94,2% e 75,8%, respectivamente. Sobrevidas atuariais livre de toxicidade retal e urinária tardias em cinco anos foram de 96,4% e 91,1%, respectivamente. Ressecção transuretral pré-radioterapia conformada 3D e doses > 70 Gy em 30% do volume da bexiga implicaram maior toxicidade urinária tardia grau 2-3 em cinco anos (p = 0,0002 e p = 0,0264, respectivamente). CONCLUSÃO: A primeira experiência relatada de radioterapia conformada 3D no Brasil permitiu altas doses de radiação, com toxicidades retal e urinária aceitáveis. A existência de ressecção transuretral de próstata pré-radioterapia conformada 3D pode sinalizar maior risco de toxicidade urinária tardia grau 2-3 após irradiação. Restrição da dose < 70 Gy em 30% do volume da bexiga à tomografia de planejamento pode reduzir complicações urinárias tardias.
Resumo:
The availability of stem cells is of great promise to study early developmental stages and to generate adequate cells for cell transfer therapies. Although many researchers using stem cells were successful in dissecting intrinsic and extrinsic mechanisms and in generating specific cell phenotypes, few of the stem cells or the differentiated cells show the capacity to repair a tissue. Advances in cell and stem cell cultivation during the last years made tremendous progress in the generation of bona fide differentiated cells able to integrate into a tissue after transplantation, opening new perspectives for developmental biology studies and for regenerative medicine. In this review, we focus on the main works attempting to create in vitro conditions mimicking the natural environment of CNS structures such as the neural tube and its development in different brain region areas including the optic cup. The use of protocols growing cells in 3D organoids is a key strategy to produce cells resembling endogenous ones. An emphasis on the generation of retina tissue and photoreceptor cells is provided to highlight the promising developments in this field. Other examples are presented and discussed, such as the formation of cortical tissue, the epithelial gut or the kidney organoids. The generation of differentiated tissues and well-defined cell phenotypes from embryonic stem (ES) cells or induced pluripotent cells (iPSCs) opens several new strategies in the field of biology and regenerative medicine. A 3D organ/tissue development in vitro derived from human cells brings a unique tool to study human cell biology and pathophysiology of an organ or a specific cell population. The perspective of tissue repair is discussed as well as the necessity of cell banking to accelerate the progress of this promising field.
Resumo:
Integrated in a wide research assessing destabilizing and triggering factors to model cliff dynamic along the Dieppe's shoreline in High Normandy, this study aims at testing boat-based mobile LiDAR capabilities by scanning 3D point clouds of the unstable coastal cliffs. Two acquisition campaigns were performed in September 2012 and September 2013, scanning (1) a 30-km-long shoreline and (2) the same test cliffs in different environmental conditions and device settings. The potentials of collected data for 3D modelling, change detection and landslide monitoring were afterward assessed. By scanning during favourable meteorological and marine conditions and close to the coast, mobile LiDAR devices are able to quickly scan a long shoreline with median point spacing up to 10cm. The acquired data are then sufficiently detailed to map geomorphological features smaller than 0.5m2. Furthermore, our capability to detect rockfalls and erosion deposits (>m3) is confirmed, since using the classical approach of computing differences between sequential acquisitions reveals many cliff collapses between Pourville and Quiberville and only sparse changes between Dieppe and Belleville-sur-Mer. These different change rates result from different rockfall susceptibilities. Finally, we also confirmed the capability of the boat-based mobile LiDAR technique to monitor single large changes, characterizing the Dieppe landslide geometry with two main active scarps, retrogression up to 40m and about 100,000m3 of eroded materials.
Resumo:
Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.