968 resultados para wrist monitor


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives To analyze the association between resting heart rate and blood pressure in male children and adolescents and to identify if this association is mediated by important confounders. Study design Cross-sectional study carried out with 356 male children and adolescents from 8 to 18 years old. Resting heart rate was measured by a portable heart rate monitor according to recommendations and stratified into quartiles. Blood pressure was measured with an electronic device previously validated for pediatric populations. Body fatness was estimated by a dual-energy x-ray absorptiometry. Results Obese subjects had values of resting heart rate 7.8% higher than nonobese (P = .001). Hypertensive children and adolescents also had elevated values of resting heart rate (P = .001). When the sample was stratified in nonobese and obese, the higher quartile of resting heart rate was associated with hypertension in both groups of children and adolescents. Conclusions This study confirms the existence of a relationship between elevated resting heart rate and increased blood pressure in a pediatric population, independent of adiposity, ethnicity and age. (J Pediatr 2011; 158:634-7).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optical monitoring systems are necessary to manufacture multilayer thin-film optical filters with low tolerance on spectrum specification. Furthermore, to have better accuracy on the measurement of film thickness, direct monitoring is a must. Direct monitoring implies acquiring spectrum data from the optical component undergoing the film deposition itself, in real time. In making film depositions on surfaces of optical components, the high vacuum evaporator chamber is the most popular equipment. Inside the evaporator, at the top of the chamber, there is a metallic support with several holes where the optical components are assembled. This metallic support has rotary motion to promote film homogenization. To acquire a measurement of the spectrum of the film in deposition, it is necessary to pass a light beam through a glass witness undergoing the film deposition process, and collect a sample of the light beam using a spectrometer. As both the light beam and the light collector are stationary, a synchronization system is required to identify the moment at which the optical component passes through the light beam.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to correlate clinical and functional evaluations with kinematic variables of upper limp reach-to-grasp movement in patients with tetraplegia. Twenty chronic patients were selected to perform reach-to-grasp kinematic assessment using a target placed at a distance equal to the arm`s length. Kinematic variables (hand peak velocity, movement time, percent time-to-maximal velocity, index of curvature, number of peaks, and joint range of motion) were correlated to clinical (Standard Neurological Classification of Spinal Cord Injury-American Spinal Injury Association) and functional [Functional Independence Measure (FIM) and Spinal Cord Independence Measure II (SCIM II)) evaluation scores. Twenty control participants were also selected to obtain normal reference parameters. There was a positive correlation between total motor index and FIM (r=0.6089; P=0.0044) and SCIM II (r=0.5229; P=0.018). Both functional scores showed positive correlation with each other (r=0.8283; P<0.0001). A correlation was also observed between the right and left motor indices, the motor AM, and the SCIM II in most of the reach-to-grasp kinematic variables studied (hand peak velocity, movement time, index of curvature, and number of peaks). In contrast, for the joint range of motion (shoulder, elbow, and wrist), only the wrist in the horizontal plane showed correlation with clinical variables. This study shows that muscle strength assessed by the American Spinal Injury Association motor index influences the reach-to-grasp kinematic variables of patients with tetraplegia. However, the functional assessments did not present the same influence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We proposed a connection admission control (CAC) to monitor the traffic in a multi-rate WDM optical network. The CAC searches for the shortest path connecting source and destination nodes, assigns wavelengths with enough bandwidth to serve the requests, supervises the traffic in the most required nodes, and if needed activates a reserved wavelength to release bandwidth according to traffic demand. We used a scale-free network topology, which includes highly connected nodes ( hubs), to enhance the monitoring procedure. Numerical results obtained from computational simulations show improved network performance evaluated in terms of blocking probability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Generally, quadriplegic individuals have difficulties performing object manipulation. Toward satisfactory manipulation, reach and grasp movements must be performed with voluntary control, and for that, grasp force feedback is essential. A hybrid system aiming at partial upper limb sensory-motor restoration for quadriplegics was built. Such device is composed of an elbow dynamic orthosis that provides elbow flexion/extension (range was approximately from 20 degrees to 120 degrees, and average angular speed was approximately 15 degrees/s) with forearm support, a wrist static orthosis and neuromuscular electrical stimulation for grasping generation, and a glove with force sensors that allows grasping force feedback. The glove presents two user interface modes: visual by light emitting diodes or audio emitted by buzzer. Voice control of the entire system (elbow dynamic orthosis and electrical stimulator) is performed by the patient. The movements provided by the hybrid system, combined with the scapular and shoulder movements performed by the patient, can aid quadriplegic individuals in tasks that involve reach and grasp movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The anaerobic biological treatment of pentachlorophenol (PCP) and methanol as the main carbon source was investigated in a horizontal-flow anaerobic immobilized biomass (HAIB) reactor at 30 +/- 1 degrees C, during a 220-day trial period. The reactor biomass was developed as an attached biofilm on polyurethane foam particles, with 24 h of hydraulic retention time. The PCP concentrations, which ranged from 2.0 to 13.0 mg/L, were controlled by adding synthetic substrate. The HAIB reactor reduced 97% of COD and removed 99% of PCP. The microbial biofilm communities of the HAIB reactor amended with PCP, without previous acclimatization, were characterized by polymerase chain reaction (PCR) and amplified ribosomal DNA restriction analysis (ARDRA) with specific Archaea oligonucleotide primers. The ARDRA technique provided an adequate analysis of the community, revealing the profile of the selected population along the reactor. The biomass activities in the HAIB reactor at the end of the experiments indicated the development of PCP degraders and the maintenance of the population of methanogenic Archaea, ensuring the high efficiency of the system treating PCP with added methanol as the cosubstrate. The use of the simplified ARDRA method enabled us to monitor the microbial population with the addition of high concentrations of toxic compounds and highlighting a selection of microorganisms in the biofilm. (C) 2008 Published by Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polarization measurements were conducted to monitor the corrosion behavior of superduplex stainless steel ASTM A995M-Gr.SA/EN 10283-Mat#1.4469(GX2CrNiMo26-7-4) when exposed to a) an electrolyte containing 22,700 parts per million (ppm) of chloride ions at seven different temperatures and b) an electrolyte at 25 GC and different chloride ion concentrations (5800, 22,700, 58,000 and 80,000 ppm of Cl(-)). The polarization curves indicate that the passive films formed are only slightly affected by NaCl concentration, but the pitting potential decreases drastically increasing the temperature, in particular >60 degrees C. The image analysis of the microstructure after potentiodynamic polarization showed that the pitting number and size vary in function of the temperature of the tested medium. Nyquist diagrams were determined by electrochemical impedance spectroscopy to characterize the resistance of the passive layer. According to Nyquist plots, the arc polarization resistance decreases increasing the temperature due to a catalytic degradation of the oxide passive films. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the need to simultaneously monitor voltage unbalance and harmonic distortions in addition to root-mean-square voltage values. An alternative way to obtain the parameters related to voltage unbalance at fundamental frequency as well as voltage harmonic distortions is here proposed, which is based on the representation of instantaneous values at the axes and at the instantaneous Euclidean norm. A new power-quality (PQ) index is then proposed to combine the effects of voltage unbalance and harmonic distortions. This new index is easily implemented into existing electronic power meters. This PQ index is determined from the analysis of temperature rise in induction motor windings, which were tested for long periods of time. This paper also shows that these voltage disturbances, which are harmful to the lifetime expectancy of motors, can be measured by alternative ways in relation to conventional methods. Although this paper deals with induction motors only, the results show the relevance for further studies on other pieces of equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As many countries are moving toward water sector reforms, practical issues of how water management institutions can better effect allocation, regulation, and enforcement of water rights have emerged. The problem of nonavailability of water to tailenders on an irrigation system in developing countries, due to unlicensed upstream diversions is well documented. The reliability of access or equivalently the uncertainty associated with water availability at their diversion point becomes a parameter that is likely to influence the application by users for water licenses, as well as their willingness to pay for licensed use. The ability of a water agency to reduce this uncertainty through effective water rights enforcement is related to the fiscal ability of the agency to monitor and enforce licensed use. In this paper, this interplay across the users and the agency is explored, considering the hydraulic structure or sequence of water use and parameters that define the users and the agency`s economics. The potential for free rider behavior by the users, as well as their proposals for licensed use are derived conditional on this setting. The analyses presented are developed in the framework of the theory of ""Law and Economics,`` with user interactions modeled as a game theoretic enterprise. The state of Ceara, Brazil, is used loosely as an example setting, with parameter values for the experiments indexed to be approximately those relevant for current decisions. The potential for using the ideas in participatory decision making is discussed. This paper is an initial attempt to develop a conceptual framework for analyzing such situations but with a focus on the reservoir-canal system water rights enforcement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work, the sensitivity of NIR spectroscopy toward the evolution of particle size was studied during emulsion homopolymerization of styrene (Sty) and emulsion copolymerization of vinyl acetate-butyl acrylate conducted in a semibatch stirred tank and a tubular pulsed sieve plate reactor, respectively. All NIR spectra were collected online with a transflectance probe immersed into the reaction medium. The spectral range used for the NIR monitoring was from 9 500 to 13 000 cm(-1), where the absorbance of the chemical components present is minimal and the changes in the NIR spectrum can be ascribed to the effects of light scattering by the polymer particles. Off-line measurements of the average diameter of the polymer particles by DLS were used as reference values for the development of the multi-variate NIR calibration models based on partial least squares. Results indicated that, in the spectral range studied, it is possible to monitor the evolution of the average size of the polymer particles during emulsion polymerization reactions. The inclusion of an additional spectral range, from 5 701 to 6 447 cm(-1), containing information on absorbances (""chemical information"") in the calibration models was also evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, three single-control charts are proposed to monitor individual observations of a bivariate Poisson process. The specified false-alarm risk, their control limits, and ARLs were determined to compare their performances for different types and sizes of shifts. In most of the cases, the single charts presented better performance rather than two separate control charts ( one for each quality characteristic). A numerical example illustrates the proposed control charts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper it is presented the theoretical background, the architecture (using the ""4+1"" model), and the use of the library for execution of adaptive devices, AdapLib. This library was created seeking to be accurate to the adaptive devices theory, and to allow its easy extension considering the specific details of solutions that employ this kind of device. As an example, it is presented a case study in which the library was used to create a proof of concept to monitor and diagnose problems in an online news portal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Forest Stewardship Council (FSC) certification promises international consumers that `green-label` timber has been logged sustainably. However, recent research indicates that this is not true for ipe (Tabebuia spp.), currently flooding the US residential decking market, much of it logged in Brazil. Uneven or non-application of minimum technical standards for certification could undermine added value and eventually the certification process itself. We examine public summary reports by third-party certifiers describing the evaluation process for certified companies in the Brazilian Amazon to determine the extent to which standards are uniformly applied and the degree to which third-party certifier requirements for compliance are consistent among properties. Current best-practice harvest systems, combined with Brazilian legal norms for harvest levels, guarantee that no certified company or community complies with FSC criteria and indicators specifying species-level management. No guidelines indicate which criteria and indicators must be enforced, or to what degree, for certification to be conferred by third-party assessors; nor do objective guidelines exist for evaluating compliance for criteria and indicators for which adequate scientific information is not yet available to identify acceptable levels. Meanwhile, certified companies are expected to monitor the long-term impacts of logging on biodiversity in addition to conducting best-practice forest management. This burden should reside elsewhere. We recommend a clarification of `sustained timber yield` that reflects current state of knowledge and practice in Amazonia. Quantifiable verifiers for best-practice forest management must be developed and consistently employed. These will need to be flexible to reflect the diversity in forest structure and dynamics that prevails across this vast region. We offer suggestions for how to achieve these goals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neozygites tanajoae is an entomopathogenic fungus which has been used for biocontrol of the cassava green mite (Mononychellus tanajoa, CGM) in Africa. Establishment and dispersal of Brazilian isolates which have been introduced into some African countries in recent years to improve CGM control was followed with specific PCR assays. Two primer pairs, NEOSSU_F/NEOSSU_R and 8DDC_F/8DDC_R, were used to differentiate isolates collected from several locations in Brazil and from three countries in Africa, Benin, Ghana and Tanzania. The first primer pair enabled the species-specific detection of Neozygites tanajoae, while the second differentiated the Brazilian isolates from those of other geographical origin. PCR assays were designed for detection of fungal DNA in the matrix of dead infested mites since N. tanajoae is difficult to isolate and culture on selective artificial media. Our results show that all isolates (Brazilian and African) that sporulated on mummified mites were amplified with the first primer pair confirming their Neozygites tanajoae identity. The second pair amplified DNA from all the Brazilian isolates, but did not amplify any DNA samples from the African isolates. None of the two primers showed amplification neither from any of the non-sporulating mite extracts nor from the dead uninfected mites used as negative controls. We confirmed that the two primer pairs tested are suitable for the detection and differential identification of N. tanajoae isolates from Brazil and Africa and that they are useful to monitor the establishment and spread of the Brazilian isolates of N. tanajoae introduced into Benin or into other African countries for improvement of CGM biocontrol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increased use of marginal quality water with drip irrigation requires sound fertigation practices that reconcile environmental concerns with viable crop production objectives. We conducted experiments to characterize dynamics and patterns of soil solution within wet bulb formed by drip irrigation. Time-domain reflectometry probes were used to monitor the distribution of potassium nitrate (KNO(3)) and water distribution from drippers discharging at constant flow rates of 2, 4 and 8 L h(-1) in soil-filled containers. Considering results from different profiles, we observed greater solute storage near the dripper decreasing gradually towards the wetting front. About half of the applied KNO(3) solution (48%) was stored in the first layer (0-0.10 m) for all experiments, 29% was stored in the next layer (0.10-0.20 m). Comparing different dripper flow rates, we observed higher solution storage for 4 L h(-1), with 45, 53 and 47% of applied KNO(3) solution accumulating in the first layer (0-0.10 m) for dripper flow rates of 2, 4 and 8 L h(-1), respectively. The results suggest that based on the volume and frequency used in this experiment, it would be advantageous to apply small amounts of solution at more frequent intervals to reduce deep percolation losses of applied water and solutes.