880 resultados para wastewater samples
Resumo:
A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the detection of several synthetic glucocorticoids in kidney, muscle and hair samples of cattle after a single intramuscular injection is described. After a dichloromethane wash of the hair samples, analytes were released from the hair matrix by enzymatic digestion. Muscle samples were also digested enzymatically using proteinase, while kidney samples were deconjugated by Helix pomatia juice. These preliminary steps were followed by a methanol extraction and a solid phase extraction (SPE) clean up step for all matrices. Chromatographic separation was achieved on a Hypersil Hypercarb column and MS/MS data were obtained in the multiple reaction monitoring mode using negative electrospray ionization. The developed protocols were evaluated by assessing residue concentrations in muscle, kidney and hair samples of thirteen calves, treated with a particular intramuscular injection of glucocorticoid. The lowest residue levels were found in muscle samples (approximately 5% of the residue levels in kidney), while high residue levels were obtained in hair samples. Hair is an interesting matrix since the sampling is non-invasive and the drugs may stay incorporated for a longer period of time. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Quartz crystal impedance analysis has been developed as a technique to assess whether room-temperature ionic liquids are Newtonian fluids and as a small-volume method for determining the values of their viscosity-density product, rho eta. Changes in the impedance spectrum of a 5-MHz fundamental frequency quartz crystal induced by a water-miscible room-temperature ionic liquid, 1-butyl-3-methylimidazolium. trifluoromethylsulfonate ([C(4)mim][OTf]), were measured. From coupled frequency shift and bandwidth changes as the concentration was varied from 0 to 100% ionic liquid, it was determined that this liquid provided a Newtonian response. A second water-immiscible ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [C(4)mim][NTf2], with concentration varied using methanol, was tested and also found to provide a Newtonian response. In both cases, the values of the square root of the viscosity-density product deduced from the small-volume quartz crystal technique were consistent with those measured using a viscometer and density meter. The third harmonic of the crystal was found to provide the closest agreement between the two measurement methods; the pure ionic liquids had the largest difference of similar to 10%. In addition, 18 pure ionic liquids were tested, and for 11 of these, good-quality frequency shift and bandwidth data were obtained; these 12 all had a Newtonian response. The frequency shift of the third harmonic was found to vary linearly with square root of viscosity-density product of the pure ionic liquids up to a value of root(rho eta) approximate to 18 kg m(-2) s(-1/2), but with a slope 10% smaller than that predicted by the Kanazawa and Gordon equation. It is envisaged that the quartz crystal technique could be used in a high-throughput microfluidic system for characterizing ionic liquids.
Resumo:
Aqueous solutions of a chlorinated VOC, 3,4-dichlorobut-1-ene, as well as other pollutants, may be mineralised to carbon dioxide, water and hydrochloric acid using a sealed rotating photocatalytic reactor. The effect of pH, dissolved oxygen concentration, light intensity, pollutant concentration and rotation speed on the degradation rate have been investigated as well as competition kinetics with methanol. This reactor may be optimised to minimise competition effects in mixed solutions. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The feasibility of using diatomite for the removal of the problematic reactive dyes as well as basic dyes from textile wastewater was investigated. Methylene blue, Cibacron reactive black and reactive yellow dyes were considered. Physical characteristics of diatomite such as pH(solution), pH(ZPC), surface area, Fourier transform infrared, and scanning electron microscopy were investigated. The surface area of diatomite was found to be 27.80 m(2) g(-1) and the pH(ZPC) occurred around pH of 5.4. The results indicated that the surface charge of diatomite decreased as the pH of the solution increased with the maximum methylene blue removal from aqueous solution occurring at basic pH of around (1011). Adsorption isotherms of diatomite with methylene blue, hydrolysed reactive black and yellow dyes were constructed at different pH values, initial dye concentrations and particle sizes. The experimental results were fitted to the Langmuir, Freundlich, and Henry models. The study indicated that electrostatic interactions play an important role in the adsorption of dyes onto diatomite. A model of the adsorption mechanism of methylene blue onto diatomite is proposed. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
This work involved the treatment of industrial wastewater from a nylon carpet printing plant which currently receives no treatment and is discharged to sea. As nylon is particularly difficult to dye, acid dyes are required for successful coloration and cause major problems with the plant's effluent disposal in terms of color removal. Granular activated carbon Filtrasorb 400 was used to treat a ternary solution of acid dyes and the process plant effluent containing the dyes in a fixed-bed column system. Experimental data were correlated using the bed depth service time (BDST) model to previously published work by the authors for single dye adsorption. The results were expressed in terms of the BDST adsorption capacity, in milligrams of adsorbate per gram of adsorbent, and indicated that there was a 12-25% decrease iri adsorption capacity in the ternary system compared to the single component system; This reduction has been attributed to competitive adsorption occurring in the ternary component system. Dye adsorption from the process plant effluent showed an approximate 65% decrease in adsorption capacity compared to the ternary solution system. This has been attributed to interference caused by the other colorless textile effluent pollutants found in the process wastewater. A chemical oxygen demand analysis on these components indicated that the dyes accounted for only 14% of the total oxygen demand.
Resumo:
Motivation: Many biomedical experiments are carried out by pooling individual biological samples. However, pooling samples can potentially hide biological variance and give false confidence concerning the data significance. In the context of microarray experiments for detecting differentially expressed genes, recent publications have addressed the problem of the efficiency of sample pooling, and some approximate formulas were provided for the power and sample size calculations. It is desirable to have exact formulas for these calculations and have the approximate results checked against the exact ones. We show that the difference between the approximate and the exact results can be large.
Resumo:
Job satisfaction can be conceptualized as a function of situational conditions, personal characteristics, and interactions between both groups of variables. The authors compared the relative predictive power of these determinants in 3 samples of professionals (total N = 1,065). Perceived job characteristics (qualification possibilities, social support, stress, autonomy, participatory leadership) uniquely explained 7-22% of the variance in job satisfaction, and dispositional factors (Big Five, occupational self-efficacy, work centrality, mastery goals) uniquely explained 8-12% of the variance. Dispositional influences were partially mediated by perceived job characteristics. Interactions between situational and dispositional factors were of little significance. The authors concluded that perceived job characteristics (especially autonomy and participatory leadership) are important determinants of job satisfaction, and neuroticism is an important determinant as well. Highly educated professionals job satisfaction also seems to be driven by qualification possibilities.
Resumo:
Background: We investigated whether eosinophils and mast cells, found in the airways of children with wheeze, were activated during relatively asymptomatic periods.
Methods: A nonbronchoscopic bronchoalveolar lavage (BAL) procedure was performed on children presenting for an elective surgical procedure. Eosinophil-derived (eosinophil cationic protein, ECP) and mast cell-derived (histamine/tryptase) mediator concentrations were measured in the BAL fluid. A detailed history and serum immunoglobulin E were used to classify the children into four groups: atopic with and without asthma, viral-associated wheeze and normal controls.
Results: The ECP concentrations in BAL from atopic asthmatic subjects were significantly higher than those measured in BAL from normal controls (P < 0.01), no other groups differed significantly. Histamine concentrations were elevated in both the atopic asthmatic and viral-associated wheeze groups compared with controls (P < 0.02) and additionally higher concentrations were obtained in atopics with asthma compared with atopics without asthma (P < 0.03). Tryptase concentrations did not differ between groups, although the tryptase and histamine concentrations correlated significantly (r = 0.78, P < 0.0001).
Conclusions: Elevated histamine concentrations were found in children with wheeze regardless of the aetiology, whereas ECP was only elevated in those asthmatics with atopy. This suggests that even in relatively quiescent periods, there is some on going activation of airway eosinophils in children with atopic asthma.
Resumo:
A selective and sensitive liquid chromatography (LC)-atmospheric pressure chemical ionisation (APCI)-mass spectroscopic (MS) assay of canrenone has been developed and validated employing Dried Blood Spots (DBS) as the sample collection medium. DBS samples were prepared by applying 30 mu l of spiked whole blood onto Guthrie cards. A 6 mm disc was punched from the each DBS and extracted with 2 ml of methanolic solution of 17 alpha-methyltestosterone (Internal Standard). The methanolic extract was evaporated to dryness and reconstituted in acetonitrile:water (1:9, v/v). The reconstituted solution was further subjected to solid phase extraction using HLB cartridges. Chromatographic separation was achieved using Waters Sunfire C18 reversed-phase column using isocratic elution, followed by a high organic wash to clear late eluting/highly retained components. The mobile phase consisted of methanol:water (60:40, v/v) pumped at a flow rate of 0.3 ml/min. LC-APCI-MS detection was performed in the selected-ion monitoring (SIM) mode using target ions at m/z 341.1 and 303.3 for canrenone and internal standard respectively. The selectivity of the method was established by analysing DBS samples from 6 different sources (individuals). The calibration curve for canrenone was found to be linear over 25-1000 ng/ml (r >0.994). Accuracy (% RE) and precision (% CV) values for within and between day were
Resumo:
In 1995. an unexpected reservoir effect was reported in sequences of bulk C-14 dates of raised bog peat. In most peat Studies bulk C-14 dates are used for obtaining chronologies. Therefore it is important to confirm and quantify such a C-14 reservoir effect. Five bulk peat samples from the raised bog Engbertsdijksveen were conventionally C-14 dated. The same core had previously been precisely dated by C-14 AMS dates of carefully selected above-ground plant remains. The existence of a reservoir effect in bulk peat C-14 samples could not be confirmed. Other explanations for the reported reservoir effect are discussed. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
The illegal use of anabolic substances in the meat producing industry is an ongoing problem due to the continual production of new synthetic compounds and/or the practice of low-level cocktail administration to avoid detection by the surveillance schemes of EU member states National Plan surveillance systems.
We present a highly sensitive reporter gene assay and sample extraction procedure based on a two step solid phase extraction and high performance liquid chromatography, developed for the detection of glucocorticoid abuse in bovine urine. The assay is capable of detecting compounds with glucocorticoid bioactivity and is extremely sensitive with an EC50 of 0.79 ng mL-1 for dexamethasone. New or unknown compounds with glucocorticoid bioactivity and low-level cocktail mixtures are detectable by this assay.
Cross-reactivity data for a range of 11ß-hydroxyglucocorticoids has been provided. This assay shows low interference from the 11-keto prohormones and other steroidal hormones. The assay may be suitable for application in other matrices such as hair. In conclusion this screening assay offers advantages over existing analytical techniques.
Resumo:
Colloidal gas aphrons (CGAs) are micron-sized gas bubbles of 25–30 µm in diameter produced by a high-speed stirrer in a vessel containing dilute surfactant solution. These bubbles, because of their small size, exhibit some colloidal properties. In this work, CGAs were used to separate fine fibres from a lean slurry of cellulosic pulp in a flotation column. The pulp fibres were recovered as foamate from the top. Sodium dodecyl sulphate at a concentration of 2.0 kg/m3 was used as a surfactant to generate the CGAs in a spinning disc apparatus. The results indicated that up to 70% flotation efficiency could be obtained within a short column height of 0.3–0.35 m. This technique can be applied to recover fine cellulosic pulp from paper-machine backwater.