951 resultados para waste water sludge


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The specific methanogenic activity (SMA) test is an important tool for the monitoring of anaerobic digestion. This paper presents the behavior of the methanogenic archaea of an anaerobic sludge under different conditions of oxygenation in a fixed-bed anaerobic-aerobic reactor treating domestic sewage. The reactor was operated in a continuous manner under different liquid recycle ratios from aerobic to anaerobic zones in order to remove carbon and nitrogen. The application of the SMA test was adapted from several authors and the measurement of the accumulated methane in the reactor was carried out by means of gas chromatography. Methanogenic organisms were not inhibited by the presence of oxygen. In contrast, the values of CH, production rate by sludge exposed to oxygen were greater than those obtained for strictly anaerobic sludge.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The properties of recycled aggregate produced from mixed (masonry and concrete) construction and demolition (C&D) waste are highly variable, and this restricts the use of such aggregate in structural concrete production. The development of classification techniques capable of reducing this variability is instrumental for quality control purposes and the production of high quality C&D aggregate. This paper investigates how the classification of C&D mixed coarse aggregate according to porosity influences the mechanical performance of concrete. Concretes using a variety of C&D aggregate porosity classes and different water/cement ratios were produced and the mechanical properties measured. For concretes produced with constant volume fractions of water, cement, natural sand and coarse aggregate from recycled mixed C&D waste, the compressive strength and Young modulus are direct exponential functions of the aggregate porosity. Sink and float technique is a simple laboratory density separation tool that facilitates the separation of cement particles with lower porosity, a difficult task when done only by visual sorting. For this experiment, separation using a 2.2 kg/dmA(3) suspension produced recycled aggregate (porosity less than 17%) which yielded good performance in concrete production. Industrial gravity separators may lead to the production of high quality recycled aggregate from mixed C&D waste for structural concrete applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study focuses on the technical feasibility of the utilization of waste from the cutting of granite to adjust the chemical composition of slag from steelworks LD, targeting the addition of clinker Portland cement. For this, chemical characterization of the waste, its mixture and fusion was performed, obtaining a CaO/SiO(2) relationship of around 0.9 to 1.2 for the steelworks slag. We selected samples of the waste, mixed, melted and cooled in water and in the oven. Samples cooled in water, after examining with X-ray difractrograms, had been predominantly amorphous. For samples cooled in the furnace, which had vitreous, there was the presence of mineralogical phases Akermanita and Gehlenita, which is considered as the ideal stage for the mineral water activity of the slag. The adjustment of the chemical composition of the slag from steel works by the addition of waste granite was efficient, transforming the waste into a product that is the same as blast furnace slag and can be used in the manufacture of cement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The optimization of the treatment process for residual waters from a brewery operating under the modality of an anaerobic reactor and activated sludge combination was studied in two phases. In the first stage, lasting for six months, the characteristics and parameters of the plant operation were analyzed, wherein a diversion rate of more than 50% to aerobic treatment, the use of two aeration tanks and a high sludge production prevailed. The second stage comprised four months during which the system worked under the proposed operational model, with the aim of improving the treatment: reduction of the diversion rate to 30% and use of only one aeration tank At each stage, TSS, VSS and COD were measured at the entrance and exit of the anaerobic reactor mid the aeration tanks. The results were compared with the corresponding design specifications and the needed conditions were applied to reduce the diversion rate towards the aerobic process through monitoring the volume and concentration of the affluent, while applying the strategic changes in reactor parameters needed to increase its efficiency. A diversion reduction from 53 to 34% was achieved, reducing the sludge discharge generated in the aerobic system from 3670mg TSS/l. with two aeration tanks down to 2947mf TSS/l using one tank keeping the same relation VSS:TSS (0.55) and an efficiency of total removal of 98% in terms of COD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper focuses on the characterization of carbide lime (CL) - a by-product of acetylene production, composed mainly of calcium hydroxide with minor parts of carbonate - and compares its features to those of ""dry"" hydrated lime (HL) commonly used as a building material. Chemical, thermogravimetric and X-ray diffraction analyses indicated that the limes are similar in chemical and mineralogical compositions. except for the presence of carbon in the waste. Morphological and elemental chemical analyses by SEM and EDS revealed that CL particles differ from HL ones in their morphology and by the presence of carbon formations, Physical characterization included density and BET surface area of the materials. as well as, their particle size distributions in deionized water at diverse time periods. CL underwent agglomeration after approximately 60 min in water, whereas HL progressively became finer with time as determined by laser diffraction. In addition, water retention and squeeze flow tests were used to assess the pastes` fresh properties. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using a dynamic systems model specifically developed for Piracicaba, Capivari and Jundia River Water Basins (BH-PCJ) as a tool to help to analyze water resources management alternatives for policy makers and decision takers, five simulations for 50 years timeframe were performed. The model estimates water supply and demand, as well as wastewater generation from the consumers at BH-PCJ. A run was performed using mean precipitation value constant, and keeping the actual water supply and demand rates, the business as usual scenario. Under these considerations, it is expected an increment of about similar to 76% on water demand, that similar to 39% of available water volume will come from wastewater reuse, and that waste load increases to similar to 91%. Falkenmark Index will change from 1,403 m(3) person(-1) year(-1) in 2004, to 734 m(3) P(-1) year(-1) by 2054, and the Sustainability Index from 0.44 to 0.20. Another four simulations were performed by affecting the annual precipitation by 90 and 110%; considering an ecological flow equal to 30% of the mean daily flow; and keeping the same rates for all other factors except for ecological flow and household water consumption. All of them showed a tendency to a water crisis in the near future at BH-PCJ.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of tannery sludge to soils is a form of recycling; however, few studies have examined the impacts of this practice on soil microbial properties. We studied effects of two applications (2006 and 2007) of tannery sludge (with a low chromium content) on the structure of the bacterial community and on the microbial activity of soils. We fertilized an agricultural area in Rolandia, Parana state, Brazil with different doses of sludge based on total N content, which ranged from 0 to 1200 kg N ha(-1). Sludge remained on the soil surface for three months before being plowed. Soils were sampled seven times during the experiment. Bacterial community structure, assessed by denaturing gradient gel electrophoresis (DGGE), was modified by the application of tannery sludge. Soon after the first application, there was clear separation between the bacterial communities in different treatments, such that each dose of sludge was associated with a specific community. These differences remained until 300 days after application and also after the second sludge application, but 666 days after the beginning of the experiment no differences were found in the bacterial communities of the lowest doses and the control. The principal response curve (PRC) analysis showed that the first sludge application strongly stimulated biological activity even 300 days after application. The second application also stimulated activity, but at a lower magnitude and for a shorter time, given that 260 days after the second application there was no difference in biological activity among treatments. PRC also showed that the properties most influenced by the application of tannery sludge were enzymatic activities related to N cycling (asparaginase and urease). The redundancy analysis (RDA) showed that tannery sludge`s influence on microbial activity is mainly related to increases in inorganic N and soil pH. Results showed that changes in the structure of the bacterial community in the studied soils were directly related to changes of their biological activity. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditional waste stabilisation pond (WSP) models encounter problems predicting pond performance because they cannot account for the influence of pond features, such as inlet structure or pond geometry, on fluid hydrodynamics. In this study, two dimensional (2-D) computational fluid dynamics (CFD) models were compared to experimental residence time distributions (RTD) from literature. In one of the-three geometries simulated, the 2-D CFD model successfully predicted the experimental RTD. However, flow patterns in the other two geometries were not well described due to the difficulty of representing the three dimensional (3-D) experimental inlet in the 2-D CFD model, and the sensitivity of the model results to the assumptions used to characterise the inlet. Neither a velocity similarity nor geometric similarity approach to inlet representation in 2-D gave results correlating with experimental data. However. it was shown that 2-D CFD models were not affected by changes in values of model parameters which are difficult to predict, particularly the turbulent inlet conditions. This work suggests that 2-D CFD models cannot be used a priori to give an adequate description of the hydrodynamic patterns in WSP. (C) 1998 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Five strains of the filamentous bacterium 'Nostocoida limicola' III were successfully isolated into pure culture from samples of activated sludge biomass from five plants in Australia. 16S rRNA gene sequence analyses showed that all isolates were members of the Planctomycetales, most closely related to Isosphaera pallida, but they differed phenotypically from this species in that they did not glide and were not thermotolerant. The ultrastructure of these 'N. limicola' III isolates was also consistent with them being Planctomycetales, in that they possessed complex intracellular membrane systems compartmentalizing the cells. However, the arrangements of these intracellular membranes differed between isolates. These data confirm that 'N. limicola' III is phylogenetically unrelated to both 'N. limicola' I and 'N. limicola' II, activated sludge filamentous bacteria which share morphological features in common with 'N. limicola' III and which have been presumed historically to be the same or very similar bacteria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) concentrations were measured in sediment and seagrass from five locations in or adjacent to the Great Barrier Reef Marine Park. A full spectrum of Cl(5-8)DDs were present in all samples and, in particular, elevated levels of Cl8DD were found. PCDFs could not be quantified in any samples. The PCDD concentrations ranged over two orders of magnitude between sites, and there was a good correlation between sediment and seagrass levels. There were large quantities of sediment present on the seagrass (20-62% on a dry wt. basis), and it was concluded that this was a primary source of the PCDDs in the seagrass samples. The PCDD levels in the seagrass samples were compared with the levels in the tissue of three dugongs stranded in the same region. The relative accumulation of the 2,3,7,8-substituted PCDD congeners in the dugongs decreased by over two orders of magnitude with increasing degree of chlorination. This was attributed to the reduced absorption of the higher chlorinated congeners in the digestive tract, a behaviour that has been observed in other mammals such as domestic cows. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent years have seen the introduction of new and varied designs of activated sludge plants. With increasing needs for higher efficiencies and lower costs, the possibility of a plant that operates more effectively has created the need for tools that can be used to evaluate and compare designs at the design stage. One such tool is the operating space diagram. It is the aim of this paper to present this tool and demonstrate its application and relevance to design using a simple case study. In the case study, use of the operating space diagram suggested changes in design that would improve the flexibility of the process. It also was useful for designing suitable control strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Industry professionals of the near future will be supported by an IT infrastructure that enables them to complete a task by drawing on resources and people with expertise anywhere in the world, and access to knowledge through specific training programs that address the task requirements. The increasing uptake of new technologies enables information to reach a diverse population and to provide flexible learning environments 24 hours a day, 7 days a week. This paper examines one of the key areas where the World Wide Web will impact on the water and wastewater industries, namely technology transfer and training. The authors will present their experiences of developing online training courses for wastewater industry professionals over the last two years. The perspective is that of two people working at the coalface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Calcium precipitation can have a number of effects on the performance of high-rate anaerobic performance including cementing of the sludge bed, limiting diffusion, and diluting the active biomass. The aim of this study was to observe the influence of precipitation in a stable full-scale system fed with high-calcium paper factory wastewater. Granules were examined from an upflow anaerobic sludge blanket reactor (volume 1,805 m(3)) at a recycled paper mill with a loading rate of 5.7-6.6 kgCOD.m(-3).d(-1) and influent calcium concentration of 400-700 gCa(.)m(-3). The granules were relatively small (1 mm), with a 200-400 mum core of calcium precipitate as observed with energy dispersive X-ray spectroscopy. Compared to other granules, Methanomicrobiales not Methanobacteriales were the dominant hydrogen or formate utilisers, and putative acidogens were filamentous. The strength of the paper mill fed granules was very high when compared to granules from other full-scale reactors, and a partial linear correlation between granule strength and calcium concentration was identified.