940 resultados para utility measurement
Resumo:
The aim of this project is to get used to another kind of programming. Since now, I used very complex programming languages to develop applications or even to program microcontrollers, but PicoCricket system is the evidence that we don’t need so complex development tools to get functional devices. PicoCricket system is the clear example of simple programming to make devices work the way we programmed it. There’s an easy but effective way to program small, devices just saying what we want them to do. We cannot do complex algorithms and mathematical operations but we can program them in a short time. Nowadays, the easier and faster we produce, the more we earn. So the tendency is to develop fast, cheap and easy, and PicoCricket system can do it.
Resumo:
The introduction of interventional radiology (IR) procedures in the 20th century has demonstrated significant advantages over surgery procedures. As a result, their number is continuously rising in diagnostic, as well as, in therapy field and is connected with progress in highly sophisticated equipment used for these purposes. Nowadays, in the European countries more than 400 fluoroscopically guided IR procedures were identified with a 10-12% increase in the number of IR examinations every year (UNSCEAR, 2010). Depending on the complexity of the different types of the interventions large differences in the radiation doses of the staff are observed.The staff that carries out IR procedures is likely to receive relatively high radiation doses, because IR procedures require the operator to remain close to the patient and close to the primary radiation beam. In spite of the fact that the operator is shielded by protective apron, the hands, eyes and legs remain practically unshielded. For this reason, one of the aims of the ORAMED project was to provide a set of standardized data on extremity doses for the personnel that are involved in IR procedures and to optimize their protection by evaluating the various factors that affect the doses. In the framework of work package 1 of the ORAMED project the impact of protective equipment, tube configuration and access routes were analyzed for the selected IR procedures. The position of maximum dose measured is also investigated. The results of the extremity doses in IR workplaces are presented in this study together with the influence of the above mentioned parameters on the doses.
Resumo:
The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.
Resumo:
Strong platelet activation results in a redistribution of negatively charged phospholipids from the cytosolic to the outer leaflet of the cellular membrane. Annexin V has a high affinity to negatively charged phospholipids and can be used to identify procoagulant platelets. Formaldehyde fixation can cause factitious Annexin V binding. Our aim was to evaluate a method for fixing platelets avoiding additional Annexin V binding. We induced expression of negatively charged phospholipids on the surface of a fraction of platelets by combined activation with convulxin and thrombin in the presence of Annexin V-fluorescein isothiocyanate and calcium. Aliquots of resting and activated platelets were fixed with a low concentration, calcium-free formaldehyde solution. Both native platelets and fixed platelets were analyzed by flow cytometry immediately and after a 24-h storage at 4°C. We observed that the percentage of Annexin V positive resting platelets ranged from 1.5 to 9.3% for the native samples and from 0.4 to 12.8% for the fixed samples (P=0.706, paired t-test). The amount of Annexin V positive convulxin/thrombin activated platelets varied from 12.9 to 35.4% without fixation and from 15.3 to 36.3% after formalin fixation (P=0.450). After a 24-h storage at 4°C, Annexin V positive platelets significantly increased both in the resting and in the convulxin/thrombin activated samples of native platelets (both P<0.001), while results for formalin fixed platelets did not differ from baseline values (P=0.318 for resting fixed platelets; P=0.673 for activated fixed platelets). We conclude that platelet fixation with a low concentration, calcium-free formaldehyde solution does not alter the proportion of Annexin V positive platelets. This method can be used to investigate properties of procoagulant platelets by multicolor flow-cytometric analysis requiring fixation steps.
Resumo:
Monitoring the performance is a crucial task for elite sports during both training and competition. Velocity is the key parameter of performance in swimming, but swimming performance evaluation remains immature due to the complexities of measurements in water. The purpose of this study is to use a single inertial measurement unit (IMU) to estimate front crawl velocity. Thirty swimmers, equipped with an IMU on the sacrum, each performed four different velocity trials of 25 m in ascending order. A tethered speedometer was used as the velocity measurement reference. Deployment of biomechanical constraints of front crawl locomotion and change detection framework on acceleration signal paved the way for a drift-free integration of forward acceleration using IMU to estimate the swimmers velocity. A difference of 0.6 ± 5.4 cm · s(-1) on mean cycle velocity and an RMS difference of 11.3 cm · s(-1) in instantaneous velocity estimation were observed between IMU and the reference. The most important contribution of the study is a new practical tool for objective evaluation of swimming performance. A single body-worn IMU provides timely feedback for coaches and sport scientists without any complicated setup or restraining the swimmer's natural technique.
Resumo:
(1,3)-b-D-glucan is a component of the fungal cell wall. New assays have made it possible to detect this molecule in a variety of clinical samples such as blood, cerebrospinal fluid, and bronchioalveolar lavage fluid. Detection of this molecule through several assays has been validated as an adjunct method to diagnose invasive fungal infections. With several decades of data and recent positive meta-analyses, these assays have now been sufficiently studied and are ready to enter the mainstream of diagnosis in medical mycology.
Resumo:
Abstract Background. In children, waist-for-height ratio (WHtR) has been proposed to identify subjects at higher risk of cardiovascular diseases. The utility of WHtR to identify children with elevated blood pressure (BP) is unclear. Design. Cross-sectional population-based study of schoolchildren. Methods. Weight, height, waist circumference and BP were measured in all sixth-grade schoolchildren of the canton de Vaud (Switzerland) in 2005/06. WHtR was computed as waist [cm]/height [cm]. Elevated BP was defined according to sex-, age- and height-specific US reference data. The area under the receiver operating characteristic curve (AUC) statistic was computed to compare the ability of body mass index (BMI) z-score and WHtR, alone or in combination, to identify children with elevated BP. Results. 5207 children participated (76% response) [2621 boys, 2586 girls; mean (± SD) age, 12.3 ± 0.5 years; range: 10.1-14.9]. The prevalence of elevated BP was 11%. Mean WHtR was 0.44 ± 0.05 (range: 0.29- 0.77) and 11% had high WHtR (> 0.5). BMI z-score and WHtR were strongly correlated (Spearman correlation coefficient r = 0.76). Both indices were positively associated with elevated BP. AUCs for elevated BP was relatively low for BMI z-score (0.62) or for WHtR (0.62), and was not substantially improved when both indices were considered together (0.63). Conclusions. The ability of BMI z-score or WHtR to identify children aged 10-14 with elevated BP was weak. Adding WHtR did not confer additional discriminative power to BMI alone. These findings do not support the measurement of WHtR in addition to BMI to identify children with elevated BP.
Resumo:
BACKGROUND: Extensive research exists estimating the effect hazardous alcohol¦use on morbidity and mortality, but little research quantifies the association between¦alcohol consumption and utility scores in patients with alcohol dependence.¦In the context of comparative research, the World Health Organisation (WHO)¦proposed to categorise the risk for alcohol-related acute and chronic harm according¦to patients' average daily alcohol consumption. OBJECTIVES: To estimate utility¦scores associated with each category of the WHO drinking risk-level classification¦in patients with alcohol dependence (AD). METHODS: We used data from¦CONTROL, an observational cohort study including 143 AD patients from the Alcohol¦Treatment Center at Lausanne University Hospital, followed for 12 months.¦Average daily alcohol consumption was assessed monthly using the Timeline Follow-¦back method and patients were categorised according to the WHO drinking¦risk-level classification: abstinent, low, medium, high and very high. Other measures¦as sociodemographic characteristics and utility scores derived from the EuroQoL¦5-Dimensions questionnaire (EQ-5D) were collected every three months.¦Mixed models for repeated measures were used to estimate mean utility scores¦associated with WHO drinking risk-level categories. RESULTS: A total of 143 patients¦were included and the 12-month follow-up permitting the assessment of¦1318 person-months. At baseline the mean age of the patients was 44.6 (SD 11.8)¦and the majority of patients was male (63.6%). Using repeated measures analysis,¦utility scores decreased with increasing drinking levels, ranging from 0.80 in abstinent¦patients to 0.62 in patients with very high risk drinking level (p_0.0001).¦CONCLUSIONS: In this sample of patients with alcohol dependence undergoing¦specialized care, utility scores estimated from the EQ-5D appeared to substantially¦and consistently vary according to patients' WHO drinking level.
Measurement of cell microrheology by magnetic twisting cytometry with frequency domain demodulation.
Resumo:
This paper presents a new respiratory impedance estimator to minimize the error due to breathing. Its practical reliability was evaluated in a simulation using realistic signals. These signals were generated by superposing pressure and flow records obtained in two conditions: 1) when applying forced oscillation to a resistance- inertance- elastance (RIE) mechanical model; 2) when healthy subjects breathed through the unexcited forced oscillation generator. Impedances computed (4-32 Hz) from the simulated signals with the new estimator resulted in a mean value which was scarcely biased by the added breathing (errors less than 1 percent in the mean R, I , and E ) and had a small variability (coefficients of variation of R, I, and E of 1.3, 3.5, and 9.6 percent, respectively). Our results suggest that the proposed estimator reduces the error in measurement of respiratory impedance without appreciable extracomputational cost.