958 resultados para urine color


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper aims to present three new methods for color detection and segmentation of road signs. The images are taken by a digital camera mounted in a car. The RGB images are converted into IHLS color space, and new methods are applied to extract the colors of the road signs under consideration. The methods are tested on hundreds of outdoor images in different light conditions, and they show high robustness. This project is part of the research taking place in Dalarna University / Sweden in the field of the ITS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asthma is a significant health issue in the pediatric population with a noteworthy growth over the years. The proposed challenge for this PhD thesis was the development of advanced methodologies to establish metabolomic patterns in urine and exhaled breath associated with asthma whose applicability was subsequently exploited to evaluate the disease state, the therapy adhesion and effect and for diagnostic purposes. The volatile composition of exhaled breath was studied combining headspace solid phase microextraction (HS-SPME) with gas chromatography coupled to mass spectrometry or with comprehensive two-dimensional gas chromatography coupled to mass spectrometry with a high resolution time of flight analyzer (GC×GC–ToFMS). These methodologies allowed the identification of several hundred compounds from different chemical families. Multivariate analysis (MVA) led to the conclusion that the metabolomic profile of asthma individuals is characterized by higher levels of compounds associated with lipid peroxidation, possibly linked to oxidative stress and inflammation (alkanes and aldehydes) known to play an important role in asthma. For future applications in clinical settings a set of nine compounds was defined and the clinical applicability was proven in monitoring the disease status and in the evaluation of the effect and / or adherence to therapy. The global volatile metabolome of urine was also explored using an HSSPME/GC×GC–ToFMS method and c.a. 200 compounds were identified. A targeted analysis was performed, with 78 compounds related with lipid peroxidation and consequently to oxidative stress levels and inflammation. The urinary non-volatile metabolomic pattern of asthma was established using proton nuclear magnetic resonance (1H NMR). This analysis allowed identifying central metabolic pathways such as oxidative stress, amino acid and lipid metabolism, gut microflora alterations, alterations in the tricarboxylic acid (TCA) cycle, histidine metabolism, lactic acidosis, and modification of free tyrosine residues after eosinophil stimulation. The obtained results allowed exploring and demonstrating the potential of analyzing the metabolomic profile of exhaled air and urine in asthma. Besides the successful development of analysis methodologies, it was possible to explore through exhaled air and urine biochemical pathways affected by asthma, observing complementarity between matrices, as well as, verify the clinical applicability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer vision is a field that uses techniques to acquire, process, analyze and understand images from the real world in order to produce numeric or symbolic information in the form of decisions [1]. This project aims to use computer vision to prepare an app to analyze a Madeira Wine and characterize it (identify its variety) by its color. Dry or sweet wines, young or old wines have a specific color. It uses techniques to compare histograms in order to analyze the images taken from a test sample inside a special container designed for this purpose. The color analysis from a wine sample using an image captured by a smartphone can be difficult. Many factors affect the captured image such as, light conditions, the background of the sample container due to the many positions the photo can be taken (different to capture facing a white wall or facing the floor for example). Using new technologies such as 3D printing it was possible to create a prototype that aims to control the effect of those external factors on the captured image. The results for this experiment are good indicators for future works. Although it’s necessary to do more tests, the first tests had a success rate of 80% to 90% of correct results. This report documents the development of this project and all the techniques and steps required to execute the tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIRES, Kelson R. T.; SANTANA, André M.; MEDEIROS, Adelardo A. D. Optical flow using color information: preliminary results. In: ANNUAL ACM SYMPOSIUM ON APPLIED COMPUTING, 23., 2008, Fortaleza. Proceedings... Fortaleza: SAC, 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho avaliou a PCR na detecção de leptospiras em sêmen e urina de dez touros sorologicamente reagentes, comparando seus resultados com aqueles obtidos por outras técnicas de diagnóstico. Foram realizadas duas colheitas de materiais em dias alternados. As amostras de sêmen e de urina foram separadas em alíquotas para visualização direta em microscopia de campo escuro, inoculação em hamsters (apenas para o sêmen), isolamento em meio de cultura e PCR. Nenhum hamster apresentou positividade na prova de soroaglutinação microscópica (SAM); fragmentos de rins e fígado desses animais foram utilizados para a tentativa de isolamento em meio de cultura, sendo positivo o cultivo a partir do rim de hamster inoculado com semen de um touro, e do fígado de hamsters inoculados com o semen de três touros. O isolamento em meio de cultura foi negativo para todas as amostras de sêmen, mas foi positivo para cinco amostras de urina. Na PCR não houve resultado positivo para as amostras de sêmen, e apenas uma amostra de urina apresentou resultado positivo, sendo coincidente com uma das culturas positivas. Não foi possível visualizar leptospiras em nenhuma das amostras por exame direto em microscopia de campo escuro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of caffeine in racing horses has been of growing concern in veterinary sports medicine since the Association of Racing Commissioners International (ARCI) stated that it has no valid therapeutic use in racehorses. We examined the kinetic alterations in the urinary excretion and salivary secretion of caffeine in seven horses subjected to urinary acidification using ascorbic acid because this procedure can simulate the acidosis that follows anaerobic exercise. They participated in two treatment groups: the control group (SG) received 500 ml of saline and then 2.0 mg kg(-1) caffeine i.v. 30 min later; and the acidified group (AG) was subjected to urinary acidification with ascorbic acid at a dose of 0.5 g kg(-1) i.v. and then 2.0. mg kg(-1) caffeine i.v. 30 min later. Samples were collected 30 min before caffeine administration, immediately before caffeine administration (time zero) and at 0.25, 0.5, 1, 2, 4, 6, 8, 12, 24, 48 and 72 h afterwards. The samples were assayed by gas chromatography. The mean urinary pH for SG was 8.2, but for AG it was as low as 5.9 at 4 h, extending acidosis for up to 8 h. The kinetic curves for the two groups were similar for urinary excretion and salivary secretion. Differences occurred only in peak excretion and peak secretion in SG obtained at 1 h and 30 min, respectively, and in AG at 2 h and 1 h, respectively. This could be explained, in part, to the diuresis in AG compared with SG, resulting in less concentrated urine in the former group. The large difference between the pK(a) of caffeine and the pH of the medium may be responsible for the similar pharmacokinetics observed for the two groups. Copyright (C) 2004 John Wiley Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enantioselective high-performance liquid chromatographic method for the analysis of carvedilol in plasma and urine was developed and validated using (-)-menthyl chloroformate (MCF) as a derivatizing reagent. Chloroform was used for extraction, and analysis was performed by HPLC on a C18 column with a fluorescence detector. The quantitation limit was 0.25 ng/ml for S(-)-carvedilol in plasma and 0.5 ng/ml for R(+)-carvedilol in plasma and for both enantiomers in urine. The method was applied to the study of enantioselectivity in the pharmacokinetics of carvedilol administered in a multiple dose regimen (25mg/12h) to a hypertensive elderly female patient. The data obtained demonstrated highest plasma levels for the R(+)-carvedilol(AUCSS 75.64 vs 37.29ng/ml). The enantiomeric ratio R(+)/S(-) was 2.03 for plasma and 1.49 0 - 12 for urine (Aeo-12 17.4 vs 11.7 pg). Copyright (c) 2008 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This method has been developed for extraction and determination of phenol in a urine sample by high performance liquid chromatography.After acid hydrolysis, the free phenol was extracted with isoamyl alcohol solvent, followed by back extraction with 0.5 mol.L-1 sodium hydroxide solution and analyzed by an isocratic HPLC Varian System, equipped with reverse-phase column (MicroPak-C-18). The mobile phase was acetonitrile in 0.01 mol.L-1 hydrochloric acid solution, (20:80 v/v), and at a now-rate of 1.0 mL.min-1. The chromatogram was monitored at 220 nm in room temperature. The identification was based on retention time and the quantification was performed by automatic peak-area determination, corrected for the external standards method.The recovery was higher than 99.5 % for phenol and reproducibility of method was shown to be 2.3% standard deviation and 5.6% coefficient of variance (n=20). The limit detection was 0.05 mgL(-1) and a range of 0.05 to 20.0 mgL(-1) of phenol for linearity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Extrinsic compression of the popliteal artery and absence of surrounding anatomical abnormalities characterize the functional popliteal artery entrapment syndrome (PAES). The diagnosis is confirmed to individuals who have typical symptoms of popliteal entrapment and occlusion or important stenosis of the popliteal artery with color duplex sonography (CDS), magnetic resonance imaging (MRI) or arteriography during active plantar flexion-extension maneuvers. However, variable result findings in normal asymptomatic subjects have raised doubts as to the validity of these tests. The purpose of this study was to compare the frequency of popliteal artery compression in 2 groups of asymptomatic subjects, athletes and non-athletes.Methods. Forty-two individuals were studied. Twenty-one subjects were indoor soccer players, and 21 were sedentary individuals. Physical activity was evaluated through questionnaires, anthropometric measurements, and cardiopulmonary exercise test. Evaluation of popliteal artery compression was performed in lower limbs with CDS, ankle-brachial index (ABI) measurements and continuous wave Doppler of the posterior tibial artery.Results. The athletes studied fulfilled the criteria of high level of physical activity whereas sedentary subjects met the criteria of low level of activity. Popliteal artery compression was observed with CDS in 6 (14.2%) studied subjects; 2 of whom (4.7%) were athletes and 4 (9.5%) were non-athletes. This difference was not statistically significant (p=0.21). Doppler of the tibial arteries and ABI measurements gave good specificity and sensibility in the identification of popliteal artery compression.Conclusion. The frequency of popliteal artery compression during maneuvers in normal subjects was 14.2% irrespective of whether or not they performed regular physical activities. Both Doppler and ABI showed good agreement with CDS and should be considered in screening popliteal arteries in individuals suspected of PAES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study is aimed to determine serum and urine interleukin-8 (IL-8) levels in premature infants with late onset sepsis (LOS) and to evaluate if urine IL-8 is a useful test for LOS diagnosis. Fifty-six premature infants admitted to the NICU over 1 year had serum and urine IL-8 determined by ELISA. They were divided into three groups: I definite sepsis, II probable sepsis and III non-infected. Results were expressed as mean or median. Differences between groups were assessed by ANOVA, Kruskal-Wallis ANOVA and Dunns Method. Sensitivity, specificity and positive and negative predictive values were calculated and a receiver operator characteristic curve was constructed to determine serum and urine IL-8 accuracy. There were no differences between groups for birth weight, and gestational and post-natal age. Median serum and urine IL-8 levels were significantly higher in GI and GII: 929 x 906 x 625pg/ml; P=0.024, and 249 x 189 x 42pg/mgCr; P< 0.001. Optimal cut-off point was 625pg/ml for serum IL-8 with 69 sensitivity and 75pg/mgCr for urine IL-8 with 92 sensitivity. IL-8 can be determined in urine from premature infants with LOS and is an accurate and feasible diagnosis method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)