868 resultados para spatial resolution


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mira and R Coronae Borealis (R CrB) variable stars are evolved objects surrounded by circumstellar envelopes (CSE) composed of the ejected stellar material. We present a detailed high-spatial resolution morfological study of the CSE of three stars: IRC+10216, the closest and more studied Carbon-Rich Mira; o Ceti, the prototype of the Mira class; and RY Sagitarii (RY Sgr), the brightest R CrB variable of the south hemisphere. JHKL near-infrared adaptive optics images of IRC+10216 with high dynamic range and Vband images with high angular resolution and high depth, collected with the VLT/NACO and VLT/FORS1 instruments, were analyzed. NACO images of o Ceti were also analyzed. Interferometric observations of RY Sgr collected with the VLTI/MIDI instrument allowed us to explore its CSE innermost regions (»20 40 mas). The CSE of IRC+10216 exhibit, in near-infrared, clumps with more complex relative displacements than proposed in previous studies. In V-band, the majority of the non-concentric shells, located in the outer CSE layers, seem to be composed of thinner elongated shells. In a global view, the morphological connection between the shells and the bipolar core of the nebulae, located in the outer layers, together with the clumps, located in the innermost regions, has a difficult interpretation. In the CSE of o Ceti, preliminar results would be indicating the presence of possible clumps. In the innermost regions (.110 UA) of the CSE of RY Sgr, two clouds were detected in different epochs, embedded in a variable gaussian envelope. Based on a rigorous verification, the first cloud was located at »100 R¤ (or »30 AU) from the centre, toward the east-north-east direction (modulo 180o) and the second one was almost at a perpendicular direction, having aproximately 2£ the distance of the first cloud. This study introduces new constraints to the mass-loss history of these kind of variables and to the morphology of their innermost CSE regions

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Orbital remote sensing has been used as a beneficial tool in improving the knowledge on oceanographic and hydrodynamic aspects in northern portion of the continental shelf of Rio Grande do Norte, offshore Potiguar Basin. Aspects such as geography, temporal and spatial resolution combined with a consistent methodology and provide a substantial economic advantage compared to traditional methods of in situ data collecting. Images of the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor onboard NASA's AQUA satellite were obtained to support systematic data collections related to the campaign of environmental monitoring and characterization of Potiguar Basin, held in May 2004. Images of Total Suspension Matter (TSM) and values of radiance standard were generated for the calculation of concentrations of total suspension matter (TSM), chlorophyll-a and sea surface temperature (SST). These data sets were used for statistical comparisons between measures in situ and satellite estimates looking validate algorithms or develop a comprehensive regional approach empirically. AQUA-MODIS images allowed the simultaneous comparison of two-dimensional water quality (total suspension matter), phytoplankton biomass (chlorophyll-a) variability and physical (temperature). For images of total suspension matter, the generated models showed a good correlation with the field data, allowing quantitative and qualitative analysis. The images of chlorophyll-a showed a consistent correlation with the in situ values of concentration. The algorithms adjusted for these images obtained a correlation coefficient fairly well with the data field in order that the sensor can be having an effect throughout the water column and not just the surface. This has led to a fit between the data of chlorophyll-the integration of the average sampling interval of the entire water column up to the level of the first optical depth, with the data generated from the images. This method resulted in higher values of chlorophyll concentration to greater depths, due to the fact that we are integrating more values of chlorophyll in the water column. Thus we can represent the biomass available in the water column. Images SST and SST measures in situ showed a mean difference DT (SST insitu - SST sat) around -0.14 ° C, considered low, making the results very good. The integration of total suspension matter, chlorophyll-a, the temperature of the sea surface (SST) and auxiliary data enabled the recognition of some of the main ways to fund the continental shelf. The main features highlighted were submerged canyons of rivers Apodi and Açu, some of the lines and beachrocks reefs, structural highs and the continental shelf break which occurs at depths around -60 m. The results confirmed the high potential for use of the AQUA-MODIS images to environmental monitoring of sea areas due to ease of detection of the field two-dimensional material in suspension on the sea surface, temperature and the concentration of chlorophyll-a

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel material for electrochemical biosensing based on rigid conducting gold nanocomposite (nano-AuGEC) is presented. Islands of chemisorbing material (gold nanoparticles) surrounded by nonreactive, rigid, and conducting graphite epoxy composite are thus achieved to avoid the stringent control of surface coverage parameters required during immobilization of thiolated oligos in continuous gold surfaces. The spatial resolution of the immobilized thiolated DNA was easily controlled by merely varying the percentage of gold nanoparticles in the composition of the composite. As low as 9 fmol (60 pM) of synthetic DNA were detected in hybridization experiments when using a thiolated probe. Moreover, for the first time a double tagging PCR strategy was performed with a thiolated primer for the detection of Salmonella sp., one of the most important foodborne pathogens affecting food safety. Ibis assay was performed by double-labeling the amplicon during the PCR with a -DIG and -SH set of labeled primers. The thiolated end allows the immobilization of the amplicon on the nano-AuGEC electrode, while digoxigenin allows the electrochemical detection with the antiDIG-HRP reporter in the femtomole range. Rigid conducting gold nanocomposite represents a good material for the improved and oriented immobilization of biomolecules with excellent transducing properties for the construction of a wide range of electrochemical biosensors such as immunosensors, genosensors, and enzymosensors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Synchrotron microtomography is a tool to quantify the mineralization of dental tissues as well as microhardness analysis, since they provide adequate precision and contrast sensitivity. This study evaluates synchrotron microtomography and microhardness analysis for quantifying the mineral content of bovine enamel. Fifty enamel blocks were submitted individually for 5 days to a pH-cycling model at 37 degrees C and remained in the remineralizing solution for 2 days. The blocks were treated twice daily for 1 min with NaF dentifrices (Placebo, 275, 550, 1,100 mu g F/g and Crest (R)) diluted in deionized water. Surface microhardness changes (%SMH) and mineral loss (Delta Z) were then calculated. Synchrotron microtomography was also used to measure total mineral lost (SMM). Pearson's correlation (p < 0.05) was used to determine the relationship between different methods of analysis and dose-response between treatments. Dentifrice fluoride concentration and %SMH and Delta Z were correlated (p < 0.05). There was a positive relationship (p < 0.05) when comparing SMM vs. Delta Z; a negative relationship (p < 0.05) was found for %SMH vs. SMM and %SMH vs. Delta Z. Based on the results of this study, it was possible to conclude that synchrotron microtomography provides the best spatial resolution and contrast sensitivity for quantifying mineral gradients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a semi-automated method for extracting road segments from medium-resolution images based on active testing and edge analysis. The method is based on two sequential and independent stages. Firstly, an active testing method is used to extract an approximated road centreline which is based on a sequential and local exploitation of the image. Secondly, an iterative strategy based on edge analysis and the approximated centreline is used to measure precisely the road centreline. Based on the results obtained using medium-resolution test images, the method seems to be very promising. In general, the method proved to be very accurate whenever the roads are characterized by two well-defined anti-parallel edges and robust even in the presence of larger obstacles such as trees and shadows.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function - MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device. © 2009 American Institute of Physics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Meteorological satellite and radar data comparative analysis allows to correlate the precipitation structures observed in both images. Such analysis would make feasible the extension of the range of ground-based meteorological radars. In addition to the different spatial and temporal resolution of these images this comparative analysis presents difficulties due to the effects of rotation and distortion, besides the different formats, projections, and coordinate systems. This work employed an approach based on a Gaussian adaptive filter in order to compare such images. The statistical results obtained from the comparison of the images are matched to those produced by other methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)