999 resultados para selection devices
Resumo:
The human olfactory receptor repertoire is reduced in comparison to other mammalsand to other non-human primates. Nonetheless, this olfactory decline opens an opportunity forevolutionary innovation and improvement. In the present study, we focus on an olfactoryreceptor gene, OR5I1, which had previously been shown to present an excess of amino acidreplacement substitutions between humans and chimpanzees. We analyze the geneticvariation in OR5I1 in a large worldwide human panel and find an excess of derived allelessegregating at relatively high frequencies in all populations. Additional evidence for selectionincludes departures from neutrality in allele frequency spectra tests but no unusually extendedhaplotype structure. Moreover, molecular structural inference suggests that one of thenonsynonymous polymorphisms defining the presumably adaptive protein form of OR5I1may alter the functional binding properties of the olfactory receptor. These results arecompatible with positive selection having modeled the pattern of variation found in the OR5I1gene and with a relatively ancient, mild selective sweep predating the “Out of Africa”expansion of modern humans.
Resumo:
Confronting a recently mated female with a strange male can induce a pregnancy block ('Bruce effect'). The physiology of this effect is well studied, but its functional significance is still not fully understood. The 'anticipated infanticide hypothesis' suggests that the pregnancy block serves to avoid the cost of embryogenesis and giving birth to offspring that are likely to be killed by a new territory holder. Some 'compatible-genes sexual selection hypotheses' suggest that the likelihood of a pregnancy block is also dependent on the female's perception of the stud's and the stimulus male's genetic quality. We used two inbred strains of mice (C57BL/6 and BALB/c) to test all possible combinations of female strain, stud strain, and stimulus strain under experimental conditions (N(total) = 241 mated females). As predicted from previous studies, we found increased rates of pregnancy blocks if stud and stimulus strains differed, and we found evidence for hybrid vigour in offspring of between-strain mating. Despite the observed heterosis, pregnancies of within-strain matings were not more likely to be blocked than pregnancies of between-strain matings. A power analysis revealed that if we missed an existing effect (type-II error), the effect must be very small. If a female gave birth, the number and weight of newborns were not significantly influenced by the stimulus males. In conclusion, we found no support for the 'compatible-genes sexual selection hypotheses'.
Resumo:
Poor understanding of the spliceosomal mechanisms to select intronic 3' ends (3'ss) is a major obstacle to deciphering eukaryotic genomes. Here, we discern the rules for global 3'ss selection in yeast. We show that, in contrast to the uniformity of yeast splicing, the spliceosome uses all available 3'ss within a distance window from the intronic branch site (BS), and that in 70% of all possible 3'ss this is likely to be mediated by pre-mRNA structures. Our results reveal that one of these RNA folds acts as an RNA thermosensor, modulating alternative splicing in response to heat shock by controlling alternate 3'ss availability. Thus, our data point to a deeper role for the pre-mRNA in the control of its own fate, and to a simple mechanism for some alternative splicing.
Resumo:
Background: The human FOXI1 gene codes for a transcription factor involved in the physiology of the inner ear, testis, and kidney. Using three interspecies comparisons, it has been suggested that this may be a gene underhuman-specific selection. We sought to confirm this finding by using an extended set of orthologous sequences.Additionally, we explored for signals of natural selection within humans by sequencing the gene in 20 Europeans,20 East Asians and 20 Yorubas and by analysing SNP variation in a 2 Mb region centered on FOXI1 in 39worldwide human populations from the HGDP-CEPH diversity panel.Results: The genome sequences recently available from other primate and non-primate species showed that FOXI1divergence patterns are compatible with neutral evolution. Sequence-based neutrality tests were not significant inEuropeans, East Asians or Yorubas. However, the Long Range Haplotype (LRH) test, as well as the iHS and XP-Rsbstatistics revealed significantly extended tracks of homozygosity around FOXI1 in Africa, suggesting a recentepisode of positive selection acting on this gene. A functionally relevant SNP, as well as several SNPs either on theputatively selected core haplotypes or with significant iHS or XP-Rsb values, displayed allele frequencies stronglycorrelated with the absolute geographical latitude of the populations sampled.Conclusions: We present evidence for recent positive selection in the FOXI1 gene region in Africa. Climate mightbe related to this recent adaptive event in humans. Of the multiple functions of FOXI1, its role in kidney-mediatedwater-electrolyte homeostasis is the most obvious candidate for explaining a climate-related adaptation.
Resumo:
Background: Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content and construct validity, responsiveness, and interpretability), the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs), i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist.Method: An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1) a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2) an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written) Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will subsequently be field-tested by assessing the inter-rater reproducibility of the checklist.Discussion: Since the study will mainly be anonymous, problems that are commonly encountered in face-to-face group meetings, such as the dominance of certain persons in the communication process, will be avoided. By performing a Delphi study and involving many experts, the likelihood that the checklist will have sufficient credibility to be accepted and implemented will increase.
Resumo:
BACKGROUND: There is a growing use of mobile devices to access the Internet. We examined whether participants who used a mobile device to access a brief online survey were quicker to respond to the survey but also, less likely to complete it than participants using a traditional web browser. FINDINGS: Using data from a recently completed online intervention trial, we found that participants using mobile devices were quicker to access the survey but less likely to complete it compared to participants using a traditional web browser. More concerning, mobile device users were also less likely to respond to a request to complete a six week follow-up survey compared to those using traditional web browsers. CONCLUSIONS: With roughly a third of participants using mobile devices to answer an online survey in this study, the impact of mobile device usage on survey completion rates is a concern. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01521078.
Resumo:
We propose an edge detector based on the selection of wellcontrasted pieces of level lines, following the proposal ofDesolneux-Moisan-Morel (DMM) [1]. The DMM edge detectorhas the problem of over-representation, that is, everyedge is detected several times in slightly different positions.In this paper we propose two modifications of the originalDMM edge detector in order to solve this problem. The firstmodification is a post-processing of the output using a generalmethod to select the best representative of a bundle of curves.The second modification is the use of Canny’s edge detectorinstead of the norm of the gradient to build the statistics. Thetwo modifications are independent and can be applied separately.Elementary reasoning and some experiments showthat the best results are obtained when both modifications areapplied together.
Resumo:
The transformer (tra) gene is a key regulator in the signalling hierarchy controlling all aspects of somatic sexual differentiation in Drosophila and other insects. Here, we show that six of the seven sequenced ants have two copies of tra. Surprisingly, the two paralogues are always more similar within species than among species. Comparative sequence analyses indicate that this pattern is owing to the ongoing concerted evolution after an ancestral duplication rather than independent duplications in each of the six species. In particular, there was strong support for inter-locus recombination between the paralogues of the ant Atta cephalotes. In the five species where the location of paralogues is known, they are adjacent to each other in four cases and separated by only few genes in the fifth case. Because there have been extensive genomic rearrangements in these lineages, this suggests selection acting to conserve their synteny. In three species, we also find a signature of positive selection in one of the paralogues. In three bee species where information is available, the tra gene is also duplicated, the copies are adjacent and in at least one species there was recombination between paralogues. These results suggest that concerted evolution plays an adaptive role in the evolution of this gene family.
Resumo:
The present paper is aimed at identifying what are the effects of the Point System of Selection of immigrants in Quebec. I defend that the distribution of points results in a different composition of immigrant stocks in terms of origin mix and not in terms of labour skills. To do so, I carry out a longitudinal descriptive analysis on the national composition of immigrants in Quebec and two other significant provinces (Ontario and British Columbia), as well as an analysis of the distribution of points in Quebec and in the rest of Canada.
Resumo:
During their development, immature CD4+ CD8+ thymocytes become committed to either the CD4 or CD8 lineage. Subsequent complete maturation of CD4+ and CD8+ cells requires a molecular match of the expressed coreceptor and the MHC specificity of the TCR. The final size of the mature CD4+ and CD8+ thymic compartments is therefore determined by a combination of lineage commitment and TCR-mediated selection. In humans and mice, the relative size of CD4+ and CD8+ peripheral T cell compartments shows marked genetic variability. We show here that genetic variations in thymic lineage commitment, rather than TCR-mediated selection processes, are responsible for the distinct CD4/CD8 ratios observed in common inbred mouse strains. Genetic variations in the regulation of lineage commitment open new ways to analyze this process and to identify the molecules involved.
Resumo:
Heart transplantation (HTx) started in 1987 at two university hospitals (CHUV, HUG) in the western part of Switzerland, with 223 HTx performed at the CHUV until December 2010. Between 1987 and 2003, 106 HTx were realized at the HUG resulting in a total of 329 HTx in the western part of Switzerland. After the relocation of organ transplantation activity in the western part of Switzerland in 2003, the surgical part and the early postoperative care of HTx remained limited to the CHUV. However, every other HTx activity are pursued at the two university hospitals (CHUV, HUG). This article summarizes the actual protocols for selection and pre-transplant follow-up of HTx candidates in the western part of Switzerland, permitting a uniform structure of pretransplant follow-up in the western part of Switzerland.
Resumo:
Presented here is a cell-suspension model for positive selection using thymocytes from alphabeta-TCR (H-2Db-restricted) transgenic mice specific to the lymphocytic choriomeningitis virus (LCMV) on a nonselecting MHC background (H-2d or TAP-1 -/-), cocultured with freshly isolated adult thymus stromal cells of the selecting MHC type. The thymic stromal cells alone induced positive selection of functional CD4- CD8+ cells whose kinetics and efficiency were enhanced by nominal peptide. Fibroblasts expressing the selecting MHC alone did not induce positive selection; however, together with nonselecting stroma and nominal peptide, there was inefficient positive. These results suggest multiple signaling in positive selection with selection events able to occur on multiple-cell types. The ease with which this model can be manipulated should greatly facilitate the resolution of the mechanisms of positive selection in normal and pathological states.
Resumo:
T cells belong to two distinct lineages expressing either alpha beta or gamma delta TCR. During alpha beta T cell development, it is clearly established that productive rearrangement at the TCR beta locus in immature precursor cells leads to the expression of a pre-TCR complex. Signaling through the pre-TCR results in the selective proliferation and maturation of TCR beta+ cells, a process that is known as beta-selection. However, the potential role of beta-selection during gamma delta T cell development is controversial. Whereas PCR-RFLP and sequencing techniques have provided evidence for a bias toward in-frame VDJ beta rearrangements in gamma delta cells (consistent with beta-selection), gamma delta cells apparently develop normally in mice that are unable to assemble a pre-TCR complex due to a deficiency in TCR beta or pT alpha genes. In this report, we have directly addressed the physiologic significance of beta-selection during gamma delta cell development in normal mice by quantitating intracellular TCR beta protein in gamma delta cells and correlating its presence with cell cycle status. Our results indicate that beta-selection plays a significant (although limited) role in gamma delta cell development by selectively amplifying a minor subset of gamma delta precursor cells with productively rearranged TCR beta genes.
Resumo:
It is commonly regarded that the overuse of traffic control devices desensitizes drivers and leads to disrespect, especially for low-volume secondary roads with limited enforcement. The maintenance of traffic signs is also a tort liability concern, exacerbated by unnecessary signs. The Federal Highway Administration’s (FHWA) Manual on Uniform Traffic Control Devices (MUTCD) and the Institute of Transportation Engineer’s (ITE) Traffic Control Devices Handbook provide guidance for the implementation of STOP signs based on expected compliance with right-of-way rules, provision of through traffic flow, context (proximity to other controlled intersections), speed, sight distance, and crash history. The approach(es) to stop is left to engineering judgment and is usually dependent on traffic volume or functional class/continuity of system. Although presently being considered by the National Committee on Traffic Control Devices, traffic volume itself is not given as a criterion for implementation in the MUTCD. STOP signs have been installed at many locations for various reasons which no longer (or perhaps never) met engineering needs. If in fact the presence of STOP signs does not increase safety, removal should be considered. To date, however, no guidance exists for the removal of STOP signs at two-way stop-controlled intersections. The scope of this research is ultra-low-volume (< 150 daily entering vehicles) unpaved intersections in rural agricultural areas of Iowa, where each of the 99 counties may have as many as 300 or more STOP sign pairs. Overall safety performance is examined as a function of a county excessive use factor, developed specifically for this study and based on various volume ranges and terrain as a proxy for sight distance. Four conclusions are supported: (1) there is no statistical difference in the safety performance of ultra-low-volume stop-controlled and uncontrolled intersections for all drivers or for younger and older drivers (although interestingly, older drivers are underrepresented at both types of intersections); (2) compliance with stop control (as indicated by crash performance) does not appear to be affected by the use or excessive use of STOP signs, even when adjusted for volume and a sight distance proxy; (3) crash performance does not appear to be improved by the liberal use of stop control; (4) safety performance of uncontrolled intersections appears to decline relative to stop-controlled intersections above about 150 daily entering vehicles. Subject to adequate sight distance, traffic professionals may wish to consider removal of control below this threshold. The report concludes with a section on methods and legal considerations for safe removal of stop control.
Resumo:
BACKGROUND: Closures of atrial septal defects or a patent foramen ovale (PFO) are increasingly performed percutaneously. The experience of late migration of a new bio-absorbable device is presented here, followed by conceptual discussion. METHODS: Six months post PFO closure with a BioSTAR® device a patient presented with chest pain. Echocardiography showed a hyperechogenic structure perforating the aortic wall. RESULTS: Surgical exploration showed a perforation of the ascending aorta by one metallic, non absorbable arm. This is the second case of late (>6 months) dislocation of the residual framework of the occluder. CONCLUSIONS: The overall incidence of perforation of cardiac structures due to secondary dislocation is low. However this complication exists and should kept in mind in symptomatic patients with new onset of chest pain, after percutaneous procedures. The concept of biodegradation, with residual, non absorbable metal braiding, should be reviewed, analyzing in particular long term results and incidence of secondary dislocation.