Resumo:
The gastrocnemius was analysed in 10 male volunteers during knee flexion and extension with the foot in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an AID conversion plaque (Model CAD 10/26), a software specially designed to record and analyse the signals, a horizontal leg press, and electrogoniometers were used. The gastrocnemius muscle showed strong potentials at the end of knee extension and beginning of knee flexion. The muscle presented a similar activity both in the zipper and lower platforms. As to bilateral action, the right gastrocnemius presented stronger potentials on the upper platforms, whereas the potentials were bilaterally similar on the lower platforms. As for foot position, the gastrocnemius presented strong potentials when the foot was in plantar flexion. The remaining positions had no effect on the work of the muscle.
Resumo:
It was studied the trapezius muscle and serratus anterior muscle in 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes, during the execution of four different modalities of military press exercises with open grip. The results showed that TS acted significantly in the modalities standing and sitting press behind neck, while SI acted in all the modalities, i.e., standing and sitting press behind neck and forward, justifying their inclusion as basic exercises for physical conditioning programmes.
Resumo:
Electromyographic activity of the trapezius muscle and serratus anterior muscle was analysed in 4 different modalities of military press exercises, each of them with 2 grips: open and middle. It was analyzed 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. The TS and SI muscles acted with high and very high activity in all the modalities of military press exercises. Statistically, they did not show significative difference in the performance of the exercises with open and middle grip, justifying the inclusion of this group of exercises with both grips for the physical conditioning programmes.
Resumo:
Electromyographic activity of the trapezius muscle and serratus anterior muscle was analysed in 24 male volunteers using a 2-channel TECA TE 4 electromyograp, during the execution of four different modalities of military press exercises with middle grip. The trapezius acted preferentially in the modalities standing press behind neck; and sitting forward and press behind neck, while SI did not show any significative difference among the modalities. The high levels of action potentials with which TS and SI acted justify the inclusion of these exercises in physical programmes.
Resumo:
The necessity of adapting the standardized fan models to conditions of higher temperature has emerged due to the growth of concerning referring to the consequences of the gas expelling after the Mont Blanc tunnel accident in Italy and France, where even though, with 100 fans in operation, 41 people died. However, since then, the defied solutions have pointed to aerodynamic disadvantages or have seemed nonappropriate in these conditions. The objective of this work is to present an alternative to the market standard fans considering a new technology in constructing blades. This new technology introduces the use of the stainless steel AISI 409 due to its good adaptation to temperatures higher than 400°C, particularly exposed to temperatures of gas exhaust from tunnels in fire situation. Furthermore, it presents a very good resistance to corrosion and posterior welding and pressing, due to its alloyed elements. The innovation is centered in the process of a deep drawing of metallic shells and posterior welding, in order to keep the ideal aerodynamic superficies for the fan ideal performance. On the other hand, the finite element method, through the elasto-plastic software COSMOS permitted the verification of the thickness and structural stability of the blade in relation to the aerodynamic efforts established in the project. In addition, it is not advisable the fabrication of blades with variable localized thickness not even, non-uniform ones, due to the verified concentration of tensions and the difficulties observed in the forming. In this way, this study recommends the construction of blades with uniform variations of thickness. © 2007 Springer.
Resumo:
It was analized the deltoid muscle anterior portion and the pectoralis major clavicular portion in 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes, in 4 modalities of military press exercises with open grip. The results showed high inactivity for PMC in almost all the modalities while DA developed very high levels of action potentials in all the modalities assessed.
Resumo:
With the objective to know the electromyographic activity normal parameters of the deltoid (anterior portion) and pectoralis major (clavicular portion) muscles in the different modalities of military press exercises with middle grip, we analyzed 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes. It was observed high inactivity levels for PMC in almost all the modalities and the concentration in the active cases, mainly, in the weak potential, while DA presented very high levels of much strong action potentials in all the modalities assessed.
Resumo:
The deltoid (anterior portion) and pectoralis major (clavicular portion) were evaluated in several execution ways of military press exercises with open and middle grips in order to know their behavior pattern. It was analyzed 24 male volunteers, using a 2-channel TECA TE4 electromyograph and Hewllet Packard surface electrodes. It was observed that the execution variation with open and middle grips does not present any significant difference as for the demanding level neither for the pectoralis major muscle nor the deltoid muscle.
Resumo:
The objectives of this work were to study the suitability and highlight the advantages of the use of cross-linked ureasil-polyether hybrid matrices as film-forming systems. The results revealed that ureasil-polyethers are excellent film-forming systems due to specific properties, such as their biocompatibility, their cosmetic attractiveness for being able to form thin and transparent films, their short drying time to form films and their excellent bioadhesion compared to the commercial products known as strong adhesives. Rheological measurements have demonstrated the ability of these hybrid matrices to form a film in only a few seconds and Water Vapor Transmitting Rate (WVTR) showed adequate semi-occlusive properties suggesting that these films could be used as skin and wound protectors. Both the high skin bioadhesion and non-cytotoxic character seems to be improved by the presence of multiple amine groups in the hybrid molecules. © 2012 Elsevier B.V.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The purpose of this study was to quantify energy expenditure (EE) during multiple sets of leg press (LP) and bench press (BP) exercises in 10 males with at least 1 yr of resistance training (RT). The subjects underwent two sessions to determine 1 repetition maximum (1RM) on the BP and LP and one protocol consisting of a warm up and 4 sets for 10 repetitions at 70% 1RM with a 3-min rest period between sets for each exercise. Energy expenditure was calculated as the sum of oxygen uptake (aerobic component), EPOC, and lactate production (anaerobic component). There were no significant differences in EE between exercises for sets 1 to 4 and the total energy expended. However, statistical analysis revealed a significant difference (P<0.05) between exercises in RT economy (BP, 0.0206 ± 0.0044 kcal·kg-1 vs. LP, 0.0051 ± 0.0015 kcal·kg-1). Within exercise comparison showed set 4 was significantly different from sets 1 and 3 for BP, and for LP a significant difference was found between set 4 and sets 1, 2 and 3. Our results point to an increase in EE during multiple sets at 70% 1RM and show that in spite of the difference in muscle mass involved and total work done during each type of exercise, EE was not different due to greater economy during the LP.
A guerra EUA x Iraque no discurso jornalístico: análise léxico-semântica das unidades de denominação
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJETIVOS: avaliar o grau de percepção do desvio de linha média superior e da angulação incisal do arco superior entre ortodontistas e leigos, assim como a influência da visualização clínica do filtro labial como referência morfológica para esse diagnóstico. MÉTODOS: foi utilizada a fotografia do sorriso de um indivíduo do gênero feminino, na qual foram produzidas alterações na linha média dentária, de 1 em 1 milímetro, até 4mm, e na angulação incisal, de 5 em 5 graus, até 15 graus, ambas para o lado esquerdo, com o auxílio de um programa de manipulação de imagens (Adobe Photoshop 7.0®).As imagens obtidas foram recortadas,formando um grupo com e outro sem a visualização do filtro labial e,em seguida,foram organizadas aleatoriamente e avaliadas por 24 ortodontistas e 24 indivíduos leigos com nível superior. RESULTADOS: os resultados obtidos revelaram que os ortodontistas foram capazes de detectar desvios da linha média a partir de 2mm (p < 0,05) e da angulação incisal a partir de 5 graus (p < 0,05), enquanto leigos só detectaram como inaceitáveis desvios a partir de 3 ou 4mm (dependendo da presença do filtro labial na imagem analisada) e 10 graus de alteração angular dos incisivos. A visualização do filtro labial na fotografia influenciou, embora suavemente, somente a avaliação dos examinadores leigos. CONCLUSÕES: conclui-se, portanto, que ortodontistas são mais críticos a pequenas variações da linha média superior e da angulação incisal do que indivíduos leigos,e que a visualização do filtro labial superior tem importância secundária como elemento de diagnóstico do desvio da linha média superior para leigos.