976 resultados para polarization curves
Resumo:
Suppose that one observes pairs (x1,Y1), (x2,Y2), ..., (xn,Yn), where x1 < x2 < ... < xn are fixed numbers while Y1, Y2, ..., Yn are independent random variables with unknown distributions. The only assumption is that Median(Yi) = f(xi) for some unknown convex or concave function f. We present a confidence band for this regression function f using suitable multiscale sign tests. While the exact computation of this band seems to require O(n4) steps, good approximations can be obtained in O(n2) steps. In addition the confidence band is shown to have desirable asymptotic properties as the sample size n tends to infinity.
Resumo:
OBJECTIVE: Orthogonal polarization spectral (OPS) imaging is used to assess mucosal microcirculation. We tested sensitivity and variability of OPS in the assessment of mesenteric blood flow (Q (sma)) reduction. SETTING: University Animal Laboratory. INTERVENTIONS: In eight pigs, Q (sma) was reduced in steps of 15% from baseline; five animals served as controls. Jejunal mucosal microcirculatory blood flow was recorded with OPS and laser Doppler flowmetry at each step. OPS data from each period were collected and randomly ordered. Samples from each period were individually chosen by two blinded investigators and quantified [capillary density (number of vessels crossing predefined lines), number of perfused villi] after agreement on the methodology. MEASUREMENT AND RESULTS: Interobserver coefficient of variation (CV) for capillary density from samples representing the same flow condition was 0.34 (0.04-1.41) and intraobserver CV was 0.10 (0.02-0.61). Only one investigator observed a decrease in capillary density [to 62% (48-82%) of baseline values at 45% Q (sma) reduction; P = 0.011], but comparisons with controls never revealed significant differences. In contrast, reduction in perfused villi was detected by both investigators at 75% of mesenteric blood flow reduction. Laser Doppler flow revealed heterogeneous microcirculatory perfusion. CONCLUSIONS: Assessment of capillary density did not reveal differences between animals with and without Q (sma) reduction, and evaluation of perfused villi revealed blood flow reduction only when Q (sma) was very low. Potential explanations are blood flow redistribution and heterogeneity, and suboptimal contrast of OPS images. Despite agreement on the method of analysis, interobserver differences in the quantification of vessel density on gut mucosa using OPS are high.
Resumo:
The degree of polarization of a refected field from active laser illumination can be used for object identifcation and classifcation. The goal of this study is to investigate methods for estimating the degree of polarization for refected fields with active laser illumination, which involves the measurement and processing of two orthogonal field components (complex amplitudes), two orthogonal intensity components, and the total field intensity. We propose to replace interferometric optical apparatuses with a computational approach for estimating the degree of polarization from two orthogonal intensity data and total intensity data. Cramer-Rao bounds for each of the three sensing modalities with various noise models are computed. Algebraic estimators and maximum-likelihood (ML) estimators are proposed. Active-set algorithm and expectation-maximization (EM) algorithm are used to compute ML estimates. The performances of the estimators are compared with each other and with their corresponding Cramer-Rao bounds. Estimators for four-channel polarimeter (intensity interferometer) sensing have a better performance than orthogonal intensities estimators and total intensity estimators. Processing the four intensities data from polarimeter, however, requires complicated optical devices, alignment, and four CCD detectors. It only requires one or two detectors and a computer to process orthogonal intensities data and total intensity data, and the bounds and estimator performances demonstrate that reasonable estimates may still be obtained from orthogonal intensities or total intensity data. Computational sensing is a promising way to estimate the degree of polarization.
Resumo:
Magnetic iron garnets as well as magnetic photonic crystals are of great interests in magneto-optic applications such as isolators, current captors, circulators, TE-TM mode conversion, wavelength accordable filters, optical sensors and switches, all of which provide a promising platform for future integrated optical circuits. In the present work, two topics are studied based on magnetic iron garnet films. In the first part, the characteristics of the magnetization are investigated for ridge waveguides fabricated on (100) oriented iron garnet thin films. The magnetic response in magneto-optic waveguides patterned on epitaxial magnetic garnet films depends on the crystallographic orientation of the waveguides and the magnetic anisotropy of the material. These can be studied by polarization rotation hysteresis loops, which are related to the component of magnetization parallel to the light propagation direction and the linear birefringence. Polarization rotation hysteresis loops for low birefringence waveguides with different orientations are experimentally investigated. Asymmetric stepped curves are obtained from waveguides along, due to the large magnetocrystalline anisotropy in the plane. A model based on the free energy density is developed to demonstrate the motion of the magnetization and can be used in the design of magneto-optic devices. The second part of this thesis focuses on the design and fabrication of high-Q cavities in two-dimensional magneto-photonic crystal slabs. The device consists of a layer of silicon and a layer of iron garnet thin film. Triangular lattice elliptical air holes are patterned in the slab. The fundamental TM band gap overlaps with the first-order TE band gap from 0374~0.431(a/λ) showing that both TE and TM polarization light can be confined in the photonic crystals. A nanocavity is designed to obtain both TE and TM defect modes in the band gaps. Additional work is needed to overlap the TE and TM defect modes and obtain a high-Q cavity so as to develop miniaturized Faraday rotators.
Resumo:
OBJECTIVE: This study developed percentile curves for anthropometric (waist circumference) and cardiovascular (lipid profile) risk factors for US children and adolescents. STUDY DESIGN: A representative sample of US children and adolescents from the National Health and Nutrition Examination Survey from 1988 to 1994 (NHANES III) and the current national series (NHANES 1999-2006) were combined. Percentile curves were constructed, nationally weighted, and smoothed using the Lambda, Mu, and Sigma method. The percentile curves included age- and sex-specific percentile values that correspond with and transition into the adult abnormal cut-off values for each of these anthropometric and cardiovascular components. To increase the sample size, a second series of percentile curves was also created from the combination of the 2 NHANES databases, along with cross-sectional data from the Bogalusa Heart Study, the Muscatine Study, the Fels Longitudinal Study and the Princeton Lipid Research Clinics Study. RESULTS: These analyses resulted in a series of growth curves for waist circumference, total cholesterol, LDL cholesterol, triglycerides, and HDL cholesterol from a combination of pediatric data sets. The cut-off for abnormal waist circumference in adult males (102 cm) was equivalent to the 94(th) percentile line in 18-year-olds, and the cut-off in adult females (88 cm) was equivalent to the 84(th) percentile line in 18-year-olds. Triglycerides were found to have a bimodal pattern among females, with an initial peak at age 11 and a second at age 20; the curve for males increased steadily with age. The HDL curve for females was relatively flat, but the male curve declined starting at age 9 years. Similar curves for total and LDL cholesterol were constructed for both males and females. When data from the additional child studies were added to the national data, there was little difference in their patterns or rates of change from year to year. CONCLUSIONS: These curves represent waist and lipid percentiles for US children and adolescents, with identification of values that transition to adult abnormalities. They could be used conditionally for both epidemiological and possibly clinical applications, although they need to be validated against longitudinal data.