843 resultados para parental attachment
Resumo:
Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.
Resumo:
Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background Head lice constitute a problem in children. Each year, numerous cases of pediculosis occur worldwide. Little work has been performed to evaluate the understanding, opinions, and actions of populations regarding head lice. These areas are important as they enable clinicians and educators to alert parents on how to avoid treatments that are innocuous or of high risk to patients.Methods A cross-sectional study was performed by interviewing the heads of households of 100 randomly chosen residences within the study area.Results The results obtained showed that 13% were infested during the first week of the survey, and 86% in the 24 weeks prior to the study. The number of positive cases increased with increasing resident number, and decreased in families with parents with a higher educational level. Itching was the principal clinical manifestation and caused sleep compromise in 65% of respondents. Innocuous and unhealthy practices to combat infestation, such as the use of inflammables and home insecticides, were common.Conclusion The results showed that certain beliefs generated worry and confusion in parents, who blamed head lice as the cause of various health problems which were not due to this insect.
Resumo:
We recorded and quantified the nocturnal activity and parental care of a brooding Common Potoo (Nyctibius griseus) using an infrared camera in southeastern Brazil. Parents alternated care of the nestling and decreased their presence as the nestling grew. Nestling feeding on passing insects while sitting on the nest, movements on the nest, wing exercising, preening, and defecating were recorded primarily while it was alone. The frequency of begging calls per hour was higher when the nestling was accompanied by one of the parents. Nocturnal recordings of this species on the nest revealed behaviors that were not cited in past studies, including: feedings bouts on passing flies performed by the nestling and adults, nestling defecation, and nestling plumage maintenance. The well-known plus newly quantified behaviors of the Common Potoo reinforce their value to survival during the long nestling period. Received 24 May 2010. Accepted 14 September 2010.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A controlled experiment, related with the mating system of Scinax rizibilis (Bokermann, 1964), was conducted to assess if larval variation could be due to size of male or its ability to manage an amplexus. Adult individuals were caught during breeding activity (from February 1993 to January 1994), in a temporary pond in the municipality of Ribeirão Branco. São Paulo State, southeastern Brazil. The duration of the larval period was not different between tadpoles of large and small males, nor was it different between tadpoles coming from natural or artificial pairs. The reproductive status of the male (if it had managed an amplexus) also did not influence the total length nor the mass of the tadpoles close to metamorphosis. However, tadpoles of larger and heavier males were, on average, approximately 5.5% and 11% larger and heavier, respectively, than tadpoles of smaller males. These results indicate that the breeding system of S. rizibilis could potentially have a directional effect on the larval characteristics.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study evaluated retention force and fatigue resistance of two overdenture attachment systems. Twenty samples (O-ring and Bar-Clip) from two manufacturers (Conexao Sistemas de Protese and Lifecore Biomedical) were prepared and divided into four groups: (i) Conexao/O-ring; (ii) Conexao/Bar-Clip; (iii) Lifecore/O-ring and (iv) Lifecore/Bar-Clip, with five samples in each group. They were submitted to mechanical fatigue test using a servohydraulic machine performing 5500 cycles of insertion and removal (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained three times (0, 3000 and after 5500 cycles) simulating the clinical service, using a tensile strength at 1 mm min(-1) and load cell of 1 kN. Data were analysed with analysis of variance and Tukey's test at 5% level. Results showed that Conexao/Bar-Clip specimens had significantly higher retention values than Lifecore/Bar-Clip (44.61 and 18.44 N, respectively), Conexao/O-ring specimens had significantly lower values than Lifecore/O-ring (13.91 and 19.75 N, respectively). Conexao/Bar-Clip values were always significantly higher than those of Conexao/O-ring group (44.61 and 13.91 N, respectively). Lifecore (O-ring and Bar-Clip) presented similar values (19.75 and 18.44 N, respectively). The systems evaluated showed satisfactory retention force values, before and after fatigue testing. Conexao/Bar-Clip specimens presented the highest values. A 5-year simulation of insertion and removal did not decrease retention values or fracture components.