991 resultados para organic laboratory safety
Resumo:
Cutaneous tuberculosis has re-emerged in the last 15 years together with the higher incidence of pulmonary tuberculosis and multidrug resistance. The choice for a single diagnostic tool among the many available today is a challenge. Our objective was to compare polymerase chain reaction (PCR) with other exams in the diagnosis of cutaneous tuberculosis and atypical mycobacteria skin infection. PCR and a set of five different exams were performed in 32 patients (34 samples of paraffin-embedded tissue) evaluated for 3 years in a university hospital, considering the response to mycobacterial infection treatment as a positive case. PCR was the most sensitive (88%) and specific (83%) exam. Culture, immunohistochemistry and acid-fast bacilli were not in agreement with clinical response to treatment. Although PCR is a useful tool, careful clinical exam is still the gold standard for the evaluation and treatment of cutaneous tuberculosis and mycobacteria skin infection.
Resumo:
Objective: To compare the triggering performance of mid-level ICU mechanical ventilators with a standard ICU mechanical ventilator. Design: Experimental bench study. Setting: The respiratory care laboratory of a university-affiliated teaching hospital. Subject: A computerized mechanical lung model, the IngMar ASL5000. Interventions: Ten mid-level ICU ventilators were compared to an ICU ventilator at two levels of lung model effort, three combinations of respiratory mechanics (normal, COPD and ARDS) and two modes of ventilation, volume and pressure assist/control. A total of 12 conditions were compared. Measurements and main results: Performance varied widely among ventilators. Mean inspiratory trigger time was < 100 ms for only half of the tested ventilators. The mean inspiratory delay time (time from initiation of the breath to return of airway pressure to baseline) was longer than that for the ICU ventilator for all tested ventilators except one. The pressure drop during triggering (Ptrig) was comparable with that of the ICU ventilator for only two ventilators. Expiratory Settling Time (time for pressure to return to baseline) had the greatest variability among ventilators. Conclusions: Triggering differences among these mid-level ICU ventilators and with the ICU ventilator were identified. Some of these ventilators had a much poorer triggering response with high inspiratory effort than the ICU ventilator. These ventilators do not perform as well as ICU ventilators in patients with high ventilatory demand.
Resumo:
Introduction: Pediatric percutaneous renal biopsy (Bx) is a routine procedure in pediatric nephrology to obtain renal tissues for histological study. We evaluated the safety, efficacy, indications and renal findings of this procedure at a tertiary care pediatric university hospital and compared our findings with the literature. Methods: Retrospective study based on medical records from January 1993 to June 2006. Results: In the study period, 305 Bx were performed in 262 patients, 127 (48.5%) male, aged 9.8 +/- 4.2 years. A 16-gauge needle was utilized in 56/305 Bx, an 18-gauge needle in 252/305 Bx (82.6%). 56.1% Bx were performed under sedation plus local anesthesia, 43.9% under general anesthesia. The number of punctures per Bx was 3.1 +/- 1.3. Minor complications occurred in 8.6% procedures. The 16-gauge needle caused a higher frequency of renal hematomas (p = 0.05). The number of glomeruli per puncture was >= 5 in 96.7% and >= 7 in 92%. Glomeruli number per puncture and frequency of complications were not different according to the type of anesthesia used. A renal pathology diagnosis was achieved in 93.1% Bx. The main indications of Bx were nephrotic syndrome (NS), lupus nephritis (LN) and hematuria (HE). The diagnosis of minimal change disease (MCD) (61.3%), class V (35.6%) and IgA nephropathy (26.3%) predominated in NS, LN and HE patients, respectively. Conclusion: Pediatric real-time ultrasound-guided percutaneous renal biopsy was safe and effective. The main clinical indications for Bx were NS and LN, the predominant renal pathology diagnoses were MCD and class V LN.
Resumo:
Goal: To describe clinical and laboratory features of human immunodeficiency infection (HIV)-infected patients with neurosyphilis. Study Design: Retrospective study of 27 consecutive cases of HIV-infected patients with a positive Venereal Disease Research Laboratory (VDRL) in cerebrospinal fluid (CSF). Results: Median of age was 36 years and 89% were men. Ten (37%) patients had previous nonneurologic syphilis treatment. At the time of neurosyphilis diagnosis, 10 (37%) patients had early syphilis, and 6 of them were neurologically asymptomatic. Nine (33%) patients had symptomatic neurosyphilis. Twenty-six (96%) patients were classified with early neurosyphilis. The medians of serum VDRL and CD4(+) T cell counts were 1:128 and 182 cell/mu L, respectively. Twenty five (93%) patients presented serum VDRL titers >= 1:16. Five of 6 patients with early syphilis and asymptomatic neurosyphilis, presented serum VDRL >= 1:16. Symptomatic patients showed lower CD4(+) T cell counts (59 cell/mu L vs. 208 cell/mu L, P = 0.03) and higher protein concentration on CSF (118 mg/dL vs. 39 mg/dL, P <0.001) than asymptomatic patients. Conclusions: Most patients had early and asymptomatic neurosyphilis, and more than one third had early syphilis. Patients with symptomatic neurosyphilis showed lower CD4(+) T cell counts and higher protein concentration on CSF than those asymptomatic. Most patients had serum VDRL titers >= 1:16, regardless of syphilis stage.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.