999 resultados para measuring professionalism


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical reduction of benzoic acid (BZA) has been studied at platinum micro-electrodes (10 and 2 mu m diameters) in acetonitrile (MeCN) and six room temperature ionic liquids (RTILs): [C(2)mim][NTf2], [C(4)min][NTf2], [C(4)mpyrr][NTf2], [C(4)mim][BF4], [C(4)mim][NO3] and [C(4)mim][PF6] (where [C(n)mim](+)=1-alkyl-3-methylimidazolium, [NTf2](-)=bis(trifluoromethylsulphonyl)imide, [C(4)mpyrr](+)=N-butyl-N-methylpyrrolidinium, [BF4](-)=tetrafluoroborate, [NO3](-)=nitrate and [PF6] = hexafluorophosphate). Based on the theoretical fitting to experimental chronoamperometric transients in [C4mpyrr][NTf2] and MeCN at several concentrations and on different size electrodes, it is suggested that a fast chemical step preceeds the electron transfer step in a CE mechanism (given below) in both RTILs and MeCN, leading to the appearance of a simple one-electron transfer mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Index properties such as the liquid limit and plastic limit are widely used to evaluate certain geotechnical parameters of fine-grained soils. Measurement of the liquid limit is a mechanical process, and the possibility of errors occurring during measurement is not significant. However, this is not the case for plastic limit testing, despite the fact that the current method of measurement is embraced by many standards around the world. The method in question relies on a fairly crude procedure known widely as the ‘thread rolling' test, though it has been the subject of much criticism in recent years. It is essential that a new, more reliable method of measuring the plastic limit is developed using a mechanical process that is both consistent and easily reproducible. The work reported in this paper concerns the development of a new device to measure the plastic limit, based on the existing falling cone apparatus. The force required for the test is equivalent to the application of a 54 N fast-static load acting on the existing cone used in liquid limit measurements. The test is complete when the relevant water content of the soil specimen allows the cone to achieve a penetration of 20 mm. The new technique was used to measure the plastic limit of 16 different clays from around the world. The plastic limit measured using the new method identified reasonably well the water content at which the soil phase changes from the plastic to the semi-solid state. Further evaluation was undertaken by conducting plastic limit tests using the new method on selected samples and comparing the results with values reported by local site investigation laboratories. Again, reasonable agreement was found.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hunter and Konieczny explored the relationships between measures of inconsistency for a belief base and the minimal inconsistent subsets of that belief base in several of their papers. In particular, an inconsistency value termed MIVC, defined from minimal inconsistent subsets, can be considered as a Shapley Inconsistency Value. Moreover, it can be axiomatized completely in terms of five simple axioms. MinInc, one of the five axioms, states that each minimal inconsistent set has the same amount of conflict. However, it conflicts with the intuition illustrated by the lottery paradox, which states that as the size of a minimal inconsistent belief base increases, the degree of inconsistency of that belief base becomes smaller. To address this, we present two kinds of revised inconsistency measures for a belief base from its minimal inconsistent subsets. Each of these measures considers the size of each minimal inconsistent subset as well as the number of minimal inconsistent subsets of a belief base. More specifically, we first present a vectorial measure to capture the inconsistency for a belief base, which is more discriminative than MIVC. Then we present a family of weighted inconsistency measures based on the vectorial inconsistency measure, which allow us to capture the inconsistency for a belief base in terms of a single numerical value as usual. We also show that each of the two kinds of revised inconsistency measures can be considered as a particular Shapley Inconsistency Value, and can be axiomatically characterized by the corresponding revised axioms presented in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we investigate the relationship between two prioritized knowledge bases by measuring both the conflict and the agreement between them.First of all, a quantity of conflict and two quantities of agreement are defined. The former is shown to be a generalization of the well-known Dalal distance which is the hamming distance between two interpretations. The latter are, respectively, a quantity of strong agreement which measures the amount ofinformation on which two belief bases “totally” agree, and a quantity of weak agreement which measures the amount of information that is believed by onesource but is unknown to the other. All three quantity measures are based on the weighted prime implicant, which represents beliefs in a prioritized belief base. We then define a degree of conflict and two degrees of agreement based on our quantity of conflict and quantities of agreement. We also consider the impact of these measures on belief merging and information source ordering.