893 resultados para magnetic resonance spectroscopy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diffusion-weighted MRI has become more and more popular in the last couple of years. It is already an accepted diagnostic tool for patients with acute stroke, but is more difficult to use for extracranial applications due to technical challenges mostly related to motion sensitivity and susceptibility variations (e.g., respiration and air-tissue boundaries). However, thanks to the newer technical developments, applications of body DW-MRI are starting to emerge. In this review, we aim to provide an overview of the current status of the published data on DW-MRI in extracranial applications. A short introduction to the physical background of this promising technique is provided, followed by the current status, subdivided into three main topics, the functional evaluation, tissue characterization and therapy monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The pathology of restless legs syndrome (RLS) is still not understood. To investigate the pathomechanism of the disorder further we recorded a surface electromyogram (EMG) of the anterior tibial muscle during functional magnetic resonance imaging (fMRI) in patients with idiopathic RLS. METHODS: Seven subjects with moderate to severe RLS were investigated in the present pilot study. Patients were lying supine in the scanner for over 50min and were instructed not to move voluntarily. Sensory leg discomfort (SLD) was evaluated on a 10-point Likert scale. For brain image analysis, an algorithm for the calculation of tonic EMG values was developed. RESULTS: We found a negative correlation of tonic EMG and SLD (p <0.01). This finding provides evidence for the clinical experience that RLS-related subjective leg discomfort increases during muscle relaxation at rest. In the fMRI analysis, the tonic EMG was associated with activation in motor and somatosensory pathways and also in some regions that are not primarily related to motor or somatosensory functions. CONCLUSIONS: By using a newly developed algorithm for the investigation of muscle tone-related changes in cerebral activity, we identified structures that are potentially involved in RLS pathology. Our method, with some modification, may also be suitable for the investigation of phasic muscle activity that occurs during periodic leg movements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In schizophrenic psychoses, structural and functional alterations of the amygdala have been demonstrated by several neuroimaging studies. However, postmortem examinations on the brains of schizophrenics did not confirm the volume changes reported by volumetric magnetic resonance imaging (MRI) studies. In order to address these contradictory findings and to further elucidate the possibly underlying pathophysiological process of the amygdala, we employed a trimodal MRI design including high-resolution volumetry, diffusion tensor imaging (DTI), and quantitative magnetization transfer imaging (qMTI) in a sample of 14 schizophrenic patients and 14 matched controls. Three-dimensional MRI volumetry revealed a significant reduction of amygdala raw volumes in the patient group, while amygdala volumes normalized for intracranial volume did not differ between the two groups. The regional diffusional anisotropy of the amygdala, expressed as inter-voxel coherence (COH), showed a marked and significant reduction in schizophrenics. Assessment of qMTI parameters yielded significant group differences for the T2 time of the bound proton pool and the T1 time of the free proton pool, while the semi-quantitative magnetization transfer ratio (MTR) did not differ between the groups. The application of multimodal MRI protocols is diagnostically relevant for the differentiation between schizophrenic patients and controls and provides a new strategy for the detection and characterization of subtle structural alterations in defined regions of the living brain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic resonance spectroscopy (MRS) of skeletal muscle has been successfully applied by physiologists over several decades, particularly for studies of high-energy phosphates (by (31)P-MRS) and glycogen (by (13)C-MRS). Unfortunately, the observation of these heteronuclei requires equipment that is typically not available on clinical MR scanners, such as broadband capability and a second channel for decoupling and nuclear Overhauser enhancement (NOE). On the other hand, (1)H-MR spectra of skeletal muscle can be acquired on many routine MR systems and also provide a wealth of physiological information. In particular, studies of intramyocellular lipids (IMCL) attract physiologists and endocrinologists because IMCL levels are related to insulin resistance and thus can lead to a better understanding of major health problems in industrial countries. The combination of (1)H-, (13)C-, and (31)P-MRS gives access to the major long- and short-term energy sources of skeletal muscle. This review summarizes the technical aspects and unique MR-methodological features of the different nuclei. It reviews clinical studies that employed MRS of one or more nuclei, or combinations of MRS with other MR modalities. It also illustrates that MR spectra contain additional physiological information that is not yet used in routine clinical applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI), 40 forensic cases were examined and findings were verified by subsequent autopsy. Results were classified as follows: (I) cause of death, (II) relevant traumatological and pathological findings, (III) vital reactions, (IV) reconstruction of injuries, (V) visualization. In these 40 forensic cases, 47 partly combined causes of death were diagnosed at autopsy, 26 (55%) causes of death were found independently using only radiological image data. Radiology was superior to autopsy in revealing certain cases of cranial, skeletal, or tissue trauma. Some forensic vital reactions were diagnosed equally well or better using MSCT/MRI. Radiological imaging techniques are particularly beneficial for reconstruction and visualization of forensic cases, including the opportunity to use the data for expert witness reports, teaching, quality control, and telemedical consultation. These preliminary results, based on the concept of "virtopsy," are promising enough to introduce and evaluate these radiological techniques in forensic medicine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because of superior soft-tissue contrast compared to other imaging techniques, non-invasive abdominal magnetic resonance imaging (MRI) is ideal for monitoring organ regeneration, tissue repair, cancer stage, and treatment effects in a wide variety of experimental animal models. Currently, sophisticated MR protocols, including technically demanding procedures for motion artefact compensation, achieve an MRI resolution limit of < 100 microm under ideal conditions. However, such a high spatial resolution is not required for most experimental rodent studies. This article describes both a detailed imaging protocol for MR data acquisition in a ubiquitously and commercially available 1.5 T MR unit and 3-dimensional volumetry of organs, tissue components, or tumors. Future developments in MR technology will allow in vivo investigation of physiological and pathological processes at the cellular and even the molecular levels. Experimental MRI is crucial for non-invasive monitoring of a broad range of biological processes and will further our general understanding of physiology and disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To determine quantitative and qualitative image quality in patients undergoing magnetic resonance (MR) cholangiography at 3.0 Tesla (T) compared with 1.5 T. MATERIALS AND METHODS: Fifty patients (30 women; mean age, 51 years) underwent MR cholangiography at 1.5 T; another 50 patients (25 women; mean age 51 years) were scanned at 3.0 T. MR sequence protocol consisted of breath-hold single-slice rapid acquisition with relaxation enhancement (RARE) and a respiratory-triggered 3D turbo spin echo (3D TSE) sequence. Maximum intensity projections were generated from the 3D TSE datasets. Contrast-to-noise ratio (CNR) measurements between the common bile duct (CBD), left and right intrahepatic duct (LHD, RHD), and periductal tissue were performed. Three radiologists assessed qualitatively the visibility of the CBD, LHD, and RHD and the overall diagnostic quality. RESULTS: Mean gain in CNR at 3.0 T versus 1.5 T in all 3 locations ranged for the RARE sequence from 7.7% to 38.1% and for the 3D TSE from 0.5% to 26.1% (P > 0.05 for all differences). Qualitative analysis did not reveal any significant difference between the 2 field strengths (P > 0.05). CONCLUSIONS: MR cholangiography at 3.0 T shows a trend toward higher CNR without improving image quality significantly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The voluntary control of micturition is believed to be integrated by complex interactions among the brainstem, subcortical areas and cortical areas. Several brain imaging studies using positron emission tomography (PET) have demonstrated that frontal brain areas, the limbic system, the pons and the premotor cortical areas were involved. However, the cortical and subcortical brain areas have not yet been precisely identified and their exact function is not yet completely understood. MATERIALS AND METHODS: This study used functional magnetic resonance imaging (fMRI) to compare brain activity during passive filling and emptying of the bladder. A cathetherism of the bladder was performed in seven healthy subjects (one man and six right-handed women). During scanning, the bladder was alternatively filled and emptied at a constant rate with bladder rincing solution. RESULTS: Comparison between passive filling of the bladder and emptying of the bladder showed an increased brain activity in the right inferior frontal gyrus, cerebellum, symmetrically in the operculum and mesial frontal. Subcortical areas were not evaluated. CONCLUSIONS: Our results suggest that several cortical brain areas are involved in the regulation of micturition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To perform a quantitative and qualitative comparison of gadobutrol and gadoterate in three-station contrast enhanced magnetic resonance angiography (CE-MRA) of the lower limbs. MATERIALS AND METHODS: In this prospective randomized controlled trial, 52 patients with leg ischemia were randomly assigned to one of two groups receiving either gadobutrol (1.0 mmol Gd/mL, 15 mL) or gadoterate (0.5 mmol Gd/mL, 30 mL). Three-station 3D CE-MRAs from the pelvis to the ankles were performed with moving-table technique on a 1.5T MR scanner. Injection time was identical in both groups. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated for 816 arteries. Contrast quality in 1196 vessel segments was evaluated separately by two blinded readers on a three-point scale. RESULTS: Mean SNR (61.8 +/- 7.8 for gadobutrol vs. 61.9 +/- 9.1 for gadoterate, P = 0.257), CNR (52.8 +/- 9.1 vs. 52.8 +/- 10.7, P = 0.154), and qualitative ranking (1.41 vs. 1.44, P = 0.21) for all vessels did not differ significantly between the two patient groups. The overall quality was good in 90.4% with gadoterate and 94.2% with gadobutrol (P = 0.462). CONCLUSION: High-concentration gadobutrol allows neither a higher CNR nor any qualitative advantage over the ordinary unspecific Gd agent gadoterate when the same Gd load and injection times are used in multistation CE-MRA of the peripheral arteries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess magnetic resonance (MR)-colonography (MRC) for detection of colorectal lesions using two different T1w three-dimensional (3D)-gradient-recalled echo (GRE)-sequences and integrated parallel data acquisition (iPAT) at a 3.0 Tesla MR-unit. MATERIALS AND METHODS: In this prospective study, 34 symptomatic patients underwent dark lumen MRC at a 3.0 Tesla unit before conventional colonoscopy (CC). After colon distension with tap water, 2 high-resolution T1w 3D-GRE [3-dimensional fast low angle shot (3D-FLASH), iPAT factor 2 and 3D-volumetric interpolated breathhold examination (VIBE), iPAT 3] sequences were acquired without and after bolus injection of gadolinium. Prospective evaluation of MRC was performed. Image quality of the different sequences was assessed qualitatively and quantitatively. The findings of the same day CC served as standard of reference. RESULTS: MRC identified all polyps >5 mm (16 of 16) in size and all carcinomas (4 of 4) correctly. Fifty percent of the small polyps 0.6). CONCLUSIONS: MRC using 3D-GRE-sequences and iPAT is feasible at 3.0 T-systems. The high-resolution 3D-FLASH was slightly preferred over the 3D-VIBE because of better image quality, although both used sequences showed no statistical significant difference.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluated with respect to linear correlation and reproducibility. Time constants were estimated by both MRI and respiratory gas analysis data and compared for agreement. A good linear correlation between signal intensity and end-expiratory gas fraction was found (correlation coefficient 0.99+/-0.01). The data were reproducible (standard error of signal intensity 8% vs. that of gas fraction 5%) and the comparison of time constants yielded a sufficient agreement. According to the good linear correlation and the acceptable reproducibility, we suggest the (19)F-MRI to be a valuable tool for quantification of intrapulmonary SF(6) and hence lung function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a case of a 34-year-old woman who had a left anterior wall myocardial infarction develop in the first trimester of pregnancy. Despite urgent and successful revascularization, she demonstrated persistent segmental wall motion abnormalities by transthoracic echocardiography. To manage this patient safely through pregnancy with a better definition of myocardium at risk, a cardiac magnetic resonance examination was performed. This identified a large territory of acutely edematous myocardium in addition to providing accurate volumetric measurements of left ventricular size and function. Because of her gravid state, gadolinium was not administered nor was it required to delineate the region of myocardium at risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) is the most promising noninvasive modality for hip joint evaluation, but it has limitations in diagnosing cartilage lesion and acetabular labrum changes, especially in early stages. This is significant due to superior outcome results of surgery intervention in hip dysplasia or femoroacetabular impingement in patients not exceeding early degeneration. This emphasizes the need for accurate and reproducible methods in evaluating cartilage structure. In this article, we discuss the impact of the most recent technological advance in MRI, namely the advantage of 3-T imaging, on diagnostic imaging of the hip. Limitations of standard imaging techniques are shown with emphasis on femoroacetabular impingement. Clinical imaging examples and biochemical techniques are presented that need to be further evaluated.