959 resultados para laser driver
Resumo:
The geometric characterisation of tree orchards is a high-precision activity comprising the accurate measurement and knowledge of the geometry and structure of the trees. Different types of sensors can be used to perform this characterisation. In this work a terrestrial LIDAR sensor (SICK LMS200) whose emission source was a 905-nm pulsed laser diode was used. Given the known dimensions of the laser beam cross-section (with diameters ranging from 12 mm at the point of emission to 47.2 mm at a distance of 8 m), and the known dimensions of the elements that make up the crops under study (flowers, leaves, fruits, branches, trunks), it was anticipated that, for much of the time, the laser beam would only partially hit a foreground target/object, with the consequent problem of mixed pixels or edge effects. Understanding what happens in such situations was the principal objective of this work. With this in mind, a series of tests were set up to determine the geometry of the emitted beam and to determine the response of the sensor to different beam blockage scenarios. The main conclusions that were drawn from the results obtained were: (i) in a partial beam blockage scenario, the distance value given by the sensor depends more on the blocked radiant power than on the blocked surface area; (ii) there is an area that influences the measurements obtained that is dependent on the percentage of blockage and which ranges from 1.5 to 2.5 m with respect to the foreground target/object. If the laser beam impacts on a second target/object located within this range, this will affect the measurement given by the sensor. To interpret the information obtained from the point clouds provided by the LIDAR sensors, such as the volume occupied and the enclosing area, it is necessary to know the resolution and the process for obtaining this mesh of points and also to be aware of the problem associated with mixed pixels.
Resumo:
Background: Proliferative retinopathy is an important cause of vision loss in diabetic patients. Incomplete panretinal photocoagulation (PRP) can lead to recurrent proliferation of new vessels. Patients and Methods: We retrospectively analysed the outcome of patients with high risk proliferative diabetic retinopathy (PDR) previously treated with slit lamp PRP who underwent indirect fill in argon laser treatment with scleral indentation under anesthesia for persistent neovascular proliferation. Results: Seventeen eyes of ten patients were included. The mean age at diabetes onset was 17.3 years SD 16.2 (range 2-44). All patients reported long standing poor glycemic control (mean HbA1c: 8.5 % SD 1.3 range 5.9-10.2). The area of retinal ischemia decreased significantly from 15 ± 7.5 disk areas (DA) before fill-in laser to 3.2 ± 4.2 DA after fill-in laser (p = 0.001). The new vessels also regressed significantly after laser treatment 8.6 ± 6.1 DA before treatment versus 6.5 ± 6.4 DA after laser treatment, (p = 0.044). Quiescent PDR was reached in 10 eyes (58.8 %) at the last visit. Conclusions: Fill-in indirect argon laser under general anesthesia should be considered to achieve further new vessels regression in high risk PDR patients. Scleral indentation and absence of pain may allow for more extensive laser application.
Resumo:
Tämä diplomityö esittää Symbianin käyttöjärjestelmän verkkoarkkitehtuuriin perustuvan paikallisverkkokortin (LAN) käyttöönottoa. Pääajatus oli keskitetty langattoman LAN— kortin (WLAN) ajureiden käyttöönottoon. Jokainen Symbianin käyttöjärjestelmän verkkoarkkitehtuurin komponentti oli huolellisesti tutkittu, painottaen mahdollista langattoman yhteyden uudelleenkäyttöä. Myös olemassaolevan Ethernetkortin ajureiden uudelleenkäyttö oli huolellisesti otettu huomioon. Diplomityöprojektin aikana esimerkki WLAN-kortin ajurin lähdekoodista oli esitetty. Tämä ajuri on kirjoitettu NOKIA DTN-20 WLAN-korttia varten. Havaittiin myös, että suurin osa Symbianin käyttöjärjestelmän verkkoarkkitehtuurista voidaan käyttää myös WLAN-pohjaisessa yhteydessä ilman muutoksia.. Esitetty ajuri käyttää myös tiettyjä olemassaolevan Ethernetkortin ajureita, esim. Logical Device Driver (LDD):tä.
Resumo:
Raaka-aineen hiukkaskoko on lääkekehityksessä keskeinen materiaaliparametri. Lääkeaineen partikkelikoko vaikuttaa moneen lääketuotteen tärkeään ominaisuuteen, esimerkiksi lääkkeen biologiseen hyväksikäytettävyyteen. Tässä diplomityössä keskityttiin jauhemaisten lääkeaineiden hiukkaskoon määrittämiseen laserdiffraktiomenetelmällä. Menetelmä perustuu siihen, että partikkeleista sironneen valon intensiteetin sirontakulmajakauma on riippuvainen partikkelien kokojakaumasta. Työn kirjallisuusosassa esiteltiin laserdiffraktiomenetelmän teoriaa. PIDS (Polarization Intensity Differential Scattering) tekniikka, jota voidaan käyttää laserdiffraktion yhteydessä, on myös kuvattu kirjallisuusosassa. Muihin menetelmiin perustuvista analyysimenetelmistä tutustuttiin mikroskopiaan sekä aerodynaamisen lentoajan määrittämiseen perustuvaan menetelmään. Kirjallisuusosassa esiteltiin myös partikkelikoon yleisimpiä esitystapoja. Työn kokeellisen osan tarkoituksena oli kehittää ja validoida laserdiffraktioon perustuva partikkelikoon määritysmenetelmä tietylle lääkeaineelle. Menetelmäkehitys tehtiin käyttäen Beckman Coulter LS 13 320 laserdiffraktoria. Laite mahdollistaa PIDS-tekniikan käytön laserdiffraktiotekniikan ohella. Menetelmäkehitys aloitettiin arvioimalla, että kyseinen lääkeaine soveltuu parhaiten määritettäväksi nesteeseen dispergoituna. Liukoisuuden perusteella väliaineeksi valittiin tällä lääkeaineella kyllästetty vesiliuos. Dispergointiaineen sekä ultraäänihauteen käyttö havaittiin tarpeelliseksi dispergoidessa kyseistä lääkeainetta kylläiseen vesiliuokseen. Lopuksi sekoitusnopeus näytteensyöttöyksikössä säädettiin sopivaksi. Validointivaiheessa kehitetyn menetelmän todettiin soveltuvan hyvin kyseiselle lääkeaineelle ja tulosten todettiin olevan oikeellisia sekä toistettavia. Menetelmä ei myöskään ollut herkkä pienille häiriöille.
Resumo:
Violation of Mendel's Law of Segregation by selfish X chromosomes that favour their own transmission is known for a number of organisms. Now, a new study reveals sex-ratio distortion favouring males and explains previously puzzling sex ratios in a Mediterranean shrub.
Resumo:
Hitsaavassa teollisuudessa kilpailukyvyn säilyttäminen edellyttää hitsauksen tehokkuuden nostoa. Niinpä metalliteollisuus etsii kuumeisesti uusia yhä tehokkaampia hitsausmenetelmiä. CO2-laserin ja MAG:in yhdistelmän muodostamalla hybridihitsauksella saadaan aikaan syvä tunkeuma kuten laserhitsauksessa, mutta sallitaan laserhitsausta väljemmät railotoleranssit. Samalla muodonmuutokset vähenevät huomattavasti verrattuna perinteiseen kaarihitsaukseen. Kaariavusteisessa laserhitsauksessa yhdistetään laserhitsaukseen perinteinen kaarihitsaus eli MIG/MAG-, TIG- tai plasmahitsaus. Menetelmää voidaan kutsua myös hybridihitsaukseksi ja sillä hyödynnetään molempien prosessien edut välttyen yksittäisten prosessien haitoilta. Prosessin haittapuolena on parametrien suuri määrä, joka on rajoittanut menetelmän käyttöönottoa. Diplomityössä tutkittiin suojakaasuseoksen koostumuksen vaikutusta rakenneteräksen CO2-laser-MAG-hybridihitsauksessa. Laserhitsauksen ja MAG-hitsauksen suojakaasuvirtaukset yhdistettiin siten, että heliumseosteinen suojakaasu tuotiin MAG-polttimen kaasukuvun kautta. Suojakaasun heliumpitoisuus nostettiin niin korkeaksi, että estettiin laserhitsauksen muodostaman plasman syntyminen. Samalla hitsauskokeissa opittiin paremmin ymmärtämään prosessia ja sen parametrien riippuvuutta toisiinsa. Tutkitut suojakaasuseokset koostuivat heliumista, argonista ja hiilidioksidista. Hitsauskokeiden perusteella havaittiin, että suojakaasuseoksen optimaalinen heliumpitoisuus on 40-50 %. Tällöin laserin tunkeumaa häiritsevää plasmapilveä ei synny ja prosessi on stabiili. Päittäisliitosten hitsauksessa suojakaasuseoksen 2 %:n CO2-pitoisuudella saadaan aikaan hyvin vähän huokosia sisältävä hitsi, jonka tunkeumaprofiilin muoto ja liittymä perusaineeseen on juoheva. Pienaliitoksilla 7 %:n CO2-pitoisuudella prosessi pysyy stabiilina ja vähäroiskeisena. Tunkeuma hieman levenee hitsin keskeltä ja hitsin liittyminen perusaineeseen on juoheva.CO2-laser-MAG-hybridihitsauksella aikaansaadaan laadukkaita hitsejä taloudellisesti, mikäli käytetyt parametrit ovat oikein valittuja. Parametrit on sovitettava jokaiseen hitsaustapaukseen erikseen, eikä niitä välttämättä voida suoraan käyttää toisessa tapauksessa.
Molecular profiling of CD8 T cells in autochthonous melanoma identifies Maf as driver of exhaustion.
Resumo:
T cells infiltrating neoplasms express surface molecules typical of chronically virus-stimulated T cells, often termed "exhausted" T cells. We compared the transcriptome of "exhausted" CD8 T cells infiltrating autochthonous melanomas to those of naïve and acutely stimulated CD8 T cells. Despite strong similarities between transcriptional signatures of tumor- and virus-induced exhausted CD8 T cells, notable differences appeared. Among transcriptional regulators, Nr4a2 and Maf were highly overexpressed in tumor-exhausted T cells and significantly upregulated in CD8 T cells from human melanoma metastases. Transduction of murine tumor-specific CD8 T cells to express Maf partially reproduced the transcriptional program associated with tumor-induced exhaustion. Upon adoptive transfer, the transduced cells showed normal homeostasis but failed to accumulate in tumor-bearing hosts and developed defective anti-tumor effector responses. We further identified TGFβ and IL-6 as main inducers of Maf expression in CD8 T cells and showed that Maf-deleted tumor-specific CD8 T cells were much more potent to restrain tumor growth in vivo. Therefore, the melanoma microenvironment contributes to skewing of CD8 T cell differentiation programs, in part by TGFβ/IL-6-mediated induction of Maf.
Resumo:
Laser diffraction (LD) and static image analysis (SIA) of rectangular particles [United States Pharmacopeia, USP30-NF25, General Chapter <776>, Optical Miroscopy.] have been systematically studied. To rule out sample dispersion and particle orientation as the root cause of differences in size distribution profiles, we immobilize powder samples on a glass plate by means of a dry disperser. For a defined region of the glass plate, we measure the diffraction pattern as induced by the dispersed particles, and the 2D dimensions of the individual particles using LD and optical microscopy, respectively. We demonstrate a correlation between LD and SIA, with the scattering intensity of the individual particles as the dominant factor. In theory, the scattering intensity is related to the square of the projected area of both spherical and rectangular particles. In traditional LD the size distribution profile is dominated by the maximum projected area of the particles (A). The diffraction diameters of a rectangular particle with length L and breadth B as measured by the LD instrument approximately correspond to spheres of diameter ØL and ØB respectively. Differences in the scattering intensity between spherical and rectangular particles suggest that the contribution made to the overall LD volume probability distribution by each rectangular particle is proportional to A2/L and A2/B. Accordingly, for rectangular particles the scattering intensity weighted diffraction diameter (SIWDD) explains an overestimation of their shortest dimension and an underestimation of their longest dimension. This study analyzes various samples of particles whose length ranges from approximately 10 to 1000 μm. The correlation we demonstrate between LD and SIA can be used to improve validation of LD methods based on SIA data for a variety of pharmaceutical powders all with a different rectangular particle size and shape.