983 resultados para inductively coupled plasma


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New technologies and sterilization agents for heat-sensitive materials are under intense investigation. Plasma sterilization, an atoxic low-temperature substitute for conventional sterilization, uses various gases that are activated by an electrical discharge, generating reactive species that promote lethality in microorganisms. Here, assays were performed using pure O-2 and O-2 + H2O2 mixture gas plasmas against a standard load of Bacillus atrophaeus spores inoculated on glass carriers inside PVC catheters. The sterilization efficiency was studied as a function of plasma system (reactive ion etching or inductively coupled plasma), biological monitor lumen diameter, gas, radio frequency power, and sub-lethal exposition time. After sterilization, the biological monitors were disassembled and the surviving bacteria were grown in trypticase soy broth using the most probable number technique. Plasma antimicrobial activity depended on the catheter's internal diameter and radio frequency powers. The N-2 + H2O2 mixture exhibited higher microbial efficacy than pure N-2 in both plasma systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A polyacrylamide hydrogel containing the Chelex-100 resin has traditionally been used as the binding agent for the diffusion gradients in thin films (DGT) technique. The Chelex-100 resin, although important for the determination of various transition metals, is unsatisfactory for the determination of alkaline earth metals, particularly Ba. In this paper, a cellulose membrane, treated with phosphate (P81 membrane), was evaluated as a binding agent for DGT devices for the determination of Ba in produced formation water (PEW) samples. In addition, diffusive layers of filter paper (cellulose) were tested to diffuse Ba through the DGT devices. Experiments to evaluate the key variables of the technique (pH, deployment time, and ionic strength/salinity) were performed. The Ba sampled by these DGT devices was measured using inductively coupled plasma optical emission spectrometry. Aiming to generate information (related to bioavailability of Ba) on the reuse of PEW for irrigation, the determination of Ba in onshore and offshore samples was performed. The new approach was effective for determination of Ba in onshore samples. To determine Ba in offshore samples, it was necessary to use an alternative calibration procedure due to the high NaCl concentration in these samples. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To investigate the effects of titanium dioxide (TiO2) nanoparticles (NPTiO2) and microparticles (MPTiO2) on the inflammatory response in the small intestine of mice. METHODS: BI 57/6 male mice received distilled water suspensions containing TiO2 (100 mg/kg body weight) as NPTiO2 (66 nm), or MPTiO2 (260 nm) by gavage for 10 d, once a day; the control group received only distilled water. At the end of the treatment the duodenum, jejunum and ileum were extracted for assessment of cytokines, inflammatory cells and titanium content. The cytokines interleukin (IL)-1b, IL-4, IL-6, IL-8, IL-10, IL-12, IL-13, IL-17, IL-23, tumor necrosis factor-alpha (TNF-alpha), intracellular interferon-gamma (IFN-gamma) and transforming growth factor-beta (TGF-beta) were evaluated by enzyme-linked immunosorbent assay in segments of jejunum and ileum (mucosa and underlying muscular tissue). CD4(+) and CD8(+) T cells, natural killer cells, and dendritic cells were evaluated in duodenum, jejunum and ileum samples fixed in 10% formalin by immunohistochemistry. The titanium content was determined by inductively coupled plasma atomic emission spectrometry. RESULTS: We found increased levels of T CD4(+) cells (cells/mm(2)) in duodenum: NP 1240 +/- 139.4, MP 1070 +/- 154.7 vs 458 +/- 50.39 (P < 0.01); jejunum: NP 908.4 +/- 130.3, MP 813.8 +/- 103.8 vs 526.6 +/- 61.43 (P < 0.05); and ileum: NP 818.60 +/- 123.0, MP 640.1 +/- 32.75 vs 466.9 +/- 22.4 (P < 0.05). In comparison to the control group, the groups receiving TiO2 showed a statistically significant increase in the levels of the inflammatory cytokines IL-12, IL-4, IL-23, TNF-alpha, IFN-gamma and TGF-beta. The cytokine production was more pronounced in the ileum (mean SE): IL-12: NP 33.98 +/- 11.76, MP 74.11 +/- 25.65 vs 19.06 +/- 3.92 (P < 0.05); IL-4: NP 17.36 +/- 9.96, MP 22.94 +/- 7.47 vs 2.19 +/- 0.65 (P < 0.05); IL-23: NP 157.20 +/- 75.80, MP 134.50 +/- 38.31 vs 22.34 +/- 5.81 (P < 0.05); TNF alpha: NP 3.71 +/- 1.33, MP 5.44 +/- 1.67 vs 0.99 +/- 019 (P < 0.05); IFN gamma: NP 15.85 +/- 9.99, MP 34.08 +/- 11.44 vs 2.81 +/- 0.69 (P < 0.05); and TGF-alpha: NP 780.70 +/- 318.50, MP 1409.00 +/- 502.20 vs 205.50 +/- 63.93 (P < 0.05). CONCLUSION: Our findings indicate that TiO2 particles induce a Th1-mediated inflammatory response in the small bowel in mice. (C) 2012 Baishideng. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Food safety is a global concern. Meat represents the most important protein source for humans. Thus, contamination of meat products by nonessential elements is a ready source of human exposure. In addition, knowledge of the concentration of essential elements is also relevant with respect to human nutrition. The aim of the present study was to determine the concentration of 17 elements in pork, beef, and chicken produced in Brazil. Meat samples were analyzed by inductively coupled plasma mass spectrometry. The estimated daily intake for nonessential elements including arsenic (As), cadmium (Cd), lead (Pb), mercury (Hg), and antimony (Sb) through meat consumption is below the toxicological reference values. However, high levels were detected for the nonessential element cesium (Cs), mainly in beef samples, an observation that deserves future studies to identify the source of contamination and potential adverse consequences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the last decades, the presence of methylmercury (MeHg) in the Amazon region of Brazil and its adverse human health effects have given rise to much concern. The biotransformation of MeHg occurs mainly through glutathione (GSH) in the bile mediated by conjugation with glutathione S-transferases (GST). Epidemiological evidence has shown that genetic polymorphisms may affect the metabolism of MeHg. The aim of this study was to evaluate the association between GST polymorphisms, GSH, and Hg levels in blood (B-Hg) and in hair (H-Hg) of an Amazon population chronically exposed to the metal through fish consumption. Blood and hair samples were collected from 144 volunteers (71 men, 73 women). B-Hg and H-Hg levels were determined by inductively coupled plasma-mass spectrometry, and GSH levels were evaluated by a spectrophotometric method. GSTM1 and T1 genotyping evaluation were carried out by multiplex polymerase chain reaction (PCR). Mean levels of B-Hg and H-Hg were 37.7 +/- 24.5 mu g/L and 10.4 +/- 7.4 mu g/g, respectively; GSH concentrations ranged from 0.52 to 2.89 mu M/ml of total blood. Distributions for GSTM1/T1, GSTM1/GSTT1*0, GSTM1*0/T1, and GSTM1*0/GSTT1*0 genotypes were 35.4, 22.2, 25.0, and 17.4%, respectively. GSTT1 genotype carriers presented lower levels of B-Hg and H-Hg when compared to other genotypes carriers. In addition, GSTM1*0/GSTT1*0 individuals presented higher Hg levels in blood and hair than subjects presenting any other genotypes. There appeared to be no evidence of an effect of polymorphisms on GSH levels. Therefore, our data suggest that GST polymorphisms may be associated with MeHg detoxification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C-18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 mu g L-1 Zn (3 sigma criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 mu g per determination, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determination of chlorine using the molecular absorption of aluminum mono-chloride (AlCl) at the 261.418 nm wavelength was accomplished by high-resolution continuum source molecular absorption spectrometry using a transversely heated graphite tube furnace with an integrated platform. For the analysis. 10 mu L of the sample followed by 10 mu L of a solution containing Al-Ag-Sr modifier, (1 g L-1 each), were directly injected onto the platform. A spectral interference due to the use of Al-Ag-Sr as mixed modifier was easily corrected by the least-squares algorithm present in the spectrometer software. The pyrolysis and vaporization temperatures were 500 degrees C and 2200 degrees C, respectively. To evaluate the feasibility of a simple procedure for the determination of chlorine in food samples present in our daily lives, two different digestion methods were applied, namely (A) an acid digestion method using HNO3 only at room temperature, and (B) a digestion method with Ag, HNO3 and H2O2, where chlorine is precipitated as a low-solubility salt (AgCl), which is then dissolved with ammonia solution. The experimental results obtained with method B were in good agreement with the certified values and demonstrated that the proposed method is more accurate than method A. This is because the formation of silver chloride prevented analyte losses by volatilization. The limit of detection (LOD, 3 sigma/s) for Cl in methods A and B was 18 mu g g(-1) and 9 mu g g(-1), respectively, 1.7 and 3.3 times lower compared to published work using inductively coupled plasma optical emission spectrometry, and absolute LODs were 2.4 and 1.2 ng, respectively. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of inductively-coupled plasma optical emission spectrometers with axial and radial views for determination of iodine in table salt was evaluated. Interference and memory effects in nitric acid and water-soluble tertiary amines (CFA-C) media were studied. Based on a factorial experiment, one optimum instrument operational condition for axial configuration, and two optima conditions for radial configuration was established. The ICP OES with axial view was 5-fold more sensitive than the radial view. Both matrix matching and standard addition methods were used for iodine quantification and for most samples, both strategies of calibration led to similar results. Recoveries ranged from 104 to 114%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is well known that the deposition of gaseous pollutants and aerosols plays a major role in causing the deterioration of monuments and built cultural heritage in European cities. Despite of many studies dedicated to the environmental damage of cultural heritage, in case of cement mortars, commonly used in the 20th century architecture, the deterioration due to air multipollutants impact, especially the formation of black crusts, is still not well explored making this issue a challenging area of research. This work centers on cement mortars – environment interactions, focusing on the diagnosis of the damage on the modern built heritage due to air multi-pollutants. For this purpose three sites, exposed to different urban areas in Europe, were selected for sampling and subsequent laboratory analyses: Centennial Hall, Wroclaw (Poland), Chiesa dell'Autostrada del Sole, Florence (Italy), Casa Galleria Vichi, Florence (Italy). The sampling sessions were performed taking into account the height from the ground level and protection from rain run off (sheltered, partly sheltered and exposed areas). The complete characterization of collected damage layer and underlying materials was performed using a range of analytical techniques: optical and scanning electron microscopy, X ray diffractometry, differential and gravimetric thermal analysis, ion chromatography, flash combustion/gas chromatographic analysis, inductively coupled plasma-optical emission spectrometer. The data were elaborated using statistical methods (i.e. principal components analyses) and enrichment factor for cement mortars was calculated for the first time. The results obtained from the experimental activity performed on the damage layers indicate that gypsum, due to the deposition of atmospheric sulphur compounds, is the main damage product at surfaces sheltered from rain run-off at Centennial Hall and Casa Galleria Vichi. By contrast, gypsum has not been identified in the samples collected at Chiesa dell'Autostrada del Sole. This is connected to the restoration works, particularly surface cleaning, regularly performed for the maintenance of the building. Moreover, the results obtained demonstrated the correlation between the location of the building and the composition of the damage layer: Centennial Hall is mainly undergoing to the impact of pollutants emitted from the close coal power stations, whilst Casa Galleria Vichi is principally affected by pollutants from vehicular exhaust in front of the building.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ZusammenfassungSchwerpunkt dieser Arbeit war die Verfahrensentwicklung zur Ultraspurenbestimmung der Platingruppenelemente (PGE) in Umwelt- und geologischen Proben unter Verwendung der massenspektrometrischen Isotopenverdünnungsanalyse mit anschließender Bestimmung an einem Quadrupol ICP-MS (ICP-QMSIVA). Geeignete Separationstechniken in der Probenaufbereitung, um die PGE von der Matrix der untersuchten Proben zu trennen, stellten eine richtige und präzise Bestimmung der Ultraspuren an einem Quadrupol ICP-MS sicher.Das Verfahren konnte anhand von geologischen Referenzmaterialien aus Kanada sichergestellt werden. Gerade die Wiederholungsbestimmungen der verschiedenen Referenzmaterialien unter Verwendung des ICP-QMSIVA Verfahrens sind beispiellos und in dieser Form noch nicht in der Literatur beschrieben. Durch systematische Messungen konnten Richtigkeit und Präzision des Verfahrens bestätigt werden und die Inhomogenität des Referenzmaterials UMT-1 bezüglich Pt bewiesen werden. Das in dieser Arbeit entwickelte Verfahren zur Ultraspurenbestimmung der PGE mit ICP-QMSIVA wurde im Rahmen des Projektes 'Production and certification of a road dust reference material for platinum, palladium and rhodium (PGEs) in automative catalytic converters (PACEPAC)' der Europäischen Union zur Zertifizierung von zwei Referenzmaterialien für Umweltproben eingesetzt. Hierbei wurde bei der Zertifizierung ('intercomparison round') eine sehr gute Übereinstimmung der Ergebnisse mit dem gewichteten Mittelwert der Ergebnisse für Pd und Pt mit den übrigen teilnehmenden Laboratorien festgestellt. Die mit der hier entwickelten Methode erhaltenen Ergebnisse wurden ohne Ausnahme für alle gemessenen Elemente zur Zertifizierung herangezogen. Damit leistete die vorliegende Arbeit einen erheblichen Beitrag zum erfolgreichen Abschluß dieses Projekts. Den Erwartungen hinsichtlich Richtigkeit und Reproduzierbarkeit des entwickelten Verfahrens wurde somit voll entsprochen. Erneut konnte die große Bedeutung der Isotopenverdünnungstechnik für die Zertifizierung von Referenzmaterialien aufgezeigt werden, da mit dieser Technik bei sachgerechtem Einsatz Ergebnisse hoher Richtigkeit erzielt werden. Durch vergleichende Messungen mit der NiS-Dokimasie und NAA, die in einer Kooperation mit dem Kernchemischen Institut der Universität Mainz durchgeführt wurden, und dem hier verwendeten Verfahren, konnten übereinstimmende Daten, hinsichtlich der Abnahme der Konzentrationen von Pd und Pt in Abhängigkeit von der Entfernung zu einer Autobahn, erzielt werden. Diese Arbeit und die Forschungsergebnisse, die mit der anerkannten NAA erzielt wurden, zeigen, daß die PGE durch Katalysatoren von Automobilen überwiegend metallisch emittiert werden. Der anthropogene Eintrag der PGE in die Umwelt kann mit dem ICP-QMSIVA Verfahren weiterhin sehr gut verfolgt werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Deutsch:Schwerpunkt dieser Arbeit war die Entwicklung einer Methode zur Spurenbestimmung von Silicium in organischen und anorganischen Matrices unter Verwendung der massenspektrometrischen Isotopenverdünnungsanalyse (MSIVA) an einem hochauflösenden induktiv gekoppelten Plasma-Massenspektrometer (HR-ICP-MS). Zusätzlich zur Elementspurenbestimmung wurde eine GC/HR-ICP-MS Kopplung entwickelt, die zur Analyse linearer und cyclischer Siloxane verwendet wurde.Die hier entwickelte Analysenmethode erlaubt Nachweisgrenzen für Silicium sowohl in organischen als auch in anorganischen Matrices im oberen ng/g-Bereich und ergab für die im Rahmen dieser Arbeit analysierten Proben Reproduzierbarkeiten von < 20%. Durch einfache Verdünnung nach der Probenvorbereitung in Verbindung mit dem sehr empfindlichen Detektionsverfahren sowie der internen Standardisierung mittels MSIVA erlaubt das Verfahren eine präzise Bestimmung von Silicium in jeglicher Matrix. Neben der Schnelligkeit und Einfachheit eignet sich die hier entwickelte Methode besonders für die Routineanalytik. Die gute Reproduzierbarkeit und der Vergleich mit Ergebnissen von zwei Interlaborstudien unterstreicht zusätzlich die Fähigkeit präzise und richtige Ergebnisse zur Zertifizierung an Standardreferenzmaterialien bezüglich des Siliciums im Spurenbereich zu liefern.Neben dem Gesamtgehalt von Silicium konnten medizinisch relevante Siliciumverbindungen analysiert und quantifiziert werden. Hierbei wurden niedermolekulare Polydimethlysiloxane (PDMS) untersucht, die als Nebenprodukte vor allem in Brustimplantaten auftreten. Grundlage für die Bestimmung dieser Siliciumspezies ist die Kopplung eines hochauflösenden ICP-MS an einen Gaschromatographen. Der hohe Ionisierungsgrad des ICP, gerade unter trockenen Plasmabedingungen, und der elementspezifische und sehr empfindliche massenspektrometrische Detektor erlauben in Verbindung mit dem GC die Bestimmung von Siloxanen bis in den pg/g-Bereich. Aus der Bestimmung des Gesamtgehalts an Silicium und der Bestimmung des Gehalts an den untersuchten Siliciumverbindungen können Vergleiche gemacht werden. Die Analyse beider Parameter ist mit Hilfe in dieser Arbeit entwickelten Methode möglich.Zusätzlich zur Siliciumbestimmung wurde der Gehalt an Platin in Humanproben analysiert, da bei der Herstellung der Füllung von Siliconimplantaten Platinkatalysatoren verwendet werden.