872 resultados para in-class test
Resumo:
Wireless Mesh Networks (WMN) have proven to be a key technology for increased network coverage of Internet infrastructures. The development process for new protocols and architectures in the area of WMN is typically split into evaluation by network simulation and testing of a prototype in a test-bed. Testing a prototype in a real test-bed is time-consuming and expensive. Irrepressible external interferences can occur which makes debugging difficult. Moreover, the test-bed usually supports only a limited number of test topologies. Finally, mobility tests are impractical. Therefore, we propose VirtualMesh as a new testing architecture which can be used before going to a real test-bed. It provides instruments to test the real communication software including the network stack inside a controlled environment. VirtualMesh is implemented by capturing real traffic through a virtual interface at the mesh nodes. The traffic is then redirected to the network simulator OMNeT++. In our experiments, VirtualMesh has proven to be scalable and introduces moderate delays. Therefore, it is suitable for predeployment testing of communication software for WMNs.
Resumo:
Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.
Resumo:
The variability of toxicity data contained within databases was investigated using the widely used US EPA ECOTOX database as an example. Fish acute lethality (LC50) values for 44 compounds (for which at least 10 data entries existed) were extracted from the ECOTOX database yielding a total of 4654 test records. Significant variability of LC50 test results was observed, exceeding several orders of magnitude. In an attempt to systematically explore potential causes of the data variability, the influence of biological factors (such as test species or life stages) and physical factors (such as water temperature, pH or water hardness) were examined. Even after eliminating the influence of these inherent factors, considerable data variability remained, suggesting an important role of factors relating to technical and measurement procedures. The analysis, however, was limited by pronounced gaps in the test documentation. Of the 4654 extracted test reports, 66.5% provided no information on the fish life stage used for testing. Likewise, water temperature, hardness or pH were not recorded in 19.6%, 48.2% and 41.2% of the data entries, respectively. From these findings, we recommend the rigorous control of data entries ensuring complete recording of testing conditions. A more consistent database will help to better discriminate between technical and natural variability of the test data, which is of importance in ecological risk assessment for extrapolation from laboratory tests to the field, and also might help to develop correction factors that account for systematic differences in test results caused by species, life stage or test conditions.
Resumo:
Zusammen mit einem namhaften Kettenhersteller hat das Institut für Fördertechnik und Logistik (IFT) im Rahmen eines AIF-geförderten Forschungsprojektes einen Kettenverschleißprüfstand für Last- und Treibketten entwickelt und gebaut, um neuentwickelte Ketten in kurzen Testphasen unter normierter Umgebung auf ihre Lebensdauer bzw. Verschleißfestigkeit zu prüfen. Durch steigende Rohstoffkosten und den immer größer werdenden Konkurrenzdruck im Bereich der Ketten entsteht ein hoher Bedarf an der Entwicklung neuer leistungsfähigerer Produkte. Die Neuheit dieser Projektidee liegt in dem erstmaligen Einsatz alternativer Werkstoffe und Konstruktionen in Kombination mit neuen verschleißarmen Beschichtungsverfahren für Kettenbauteile um Schmierstoffe langfristig einzulagern und bedarfsgerecht abzugeben
Resumo:
In young, first-episode, productive, medication-naive patients with schizophrenia, EEG microstates (building blocks of mentation) tend to be shortened. Koenig et al. [Koenig, T., Lehmann, D., Merlo, M., Kochi, K., Hell, D., Koukkou, M., 1999. A deviant EEG brain microstate in acute, neuroleptic-naïve schizophrenics at rest. European Archives of Psychiatry and Clinical Neuroscience 249, 205–211] suggested that shortening concerned specific microstate classes. Sequence rules (microstate concatenations, syntax) conceivably might also be affected. In 27 patients of the above type and 27 controls, from three centers, multichannel resting EEG was analyzed into microstates using k-means clustering of momentary potential topographies into four microstate classes (A–D). In patients, microstates were shortened in classes B and D (from 80 to 70 ms and from 94 to 82 ms, respectively), occurred more frequently in classes A and C, and covered more time in A and less in B. Topography differed only in class B where LORETA tomography predominantly showed stronger left and anterior activity in patients. Microstate concatenation (syntax) generally were disturbed in patients; specifically, the class sequence A→C→D→A predominated in controls, but was reversed in patients (A→D→C→A). In schizophrenia, information processing in certain classes of mental operations might deviate because of precocious termination. The intermittent occurrence might account for Bleuler's “double bookkeeping.” The disturbed microstate syntax opens a novel physiological comparison of mental operations between patients and controls.
Resumo:
HYPOTHESIS We hypothesized that arthroscopic rotator cuff repairs using leukocyte- and platelet-rich fibrin (L-PRF) in a standardized, modified protocol is technically feasible and results in a higher vascularization response and watertight healing rate during early healing. METHODS Twenty patients with chronic rotator cuff tears were randomly assigned to 2 treatment groups. In the test group (N = 10), L-PRF was added in between the tendon and the bone during arthroscopic rotator cuff repair. The second group served as control (N = 10). They received the same arthroscopic treatment without the use of L-PRF. We used a double-row tension band technique. Clinical examinations including subjective shoulder value, visual analog scale, Constant, and Simple Shoulder Test scores and measurement of the vascularization with power Doppler ultrasonography were made at 6 and 12 weeks. RESULTS There have been no postoperative complications. At 6 and 12 weeks, there was no significant difference in the clinical scores between the test and the control groups. The mean vascularization index of the surgical tendon-to-bone insertions was always significantly higher in the L-PRF group than in the contralateral healthy shoulders at 6 and 12 weeks (P = .0001). Whereas the L-PRF group showed a higher vascularization compared with the control group at 6 weeks (P = .001), there was no difference after 12 weeks of follow-up (P = .889). Watertight healing was obtained in 89% of the repaired cuffs. DISCUSSION/CONCLUSIONS Arthroscopic rotator cuff repair with the application of L-PRF is technically feasible and yields higher early vascularization. Increased vascularization may potentially predispose to an increased and earlier cellular response and an increased healing rate.
Resumo:
Bei Medikamentenallergien kommt es zu Immunreaktionen, die gegen das Medikament gerichtet sind und klinische Symptome verursachen. Man unterscheidet zwischen Hapten- und p-i-bedingten Reaktionen, wobei letztere nur für T-Zell-Reaktionen nachgewiesen wurden. Die häufigsten Immunmechanismen, welche Medikamentenallergien zugrunde liegen, sind Vermehrung von spezifischen IgE-produzierenden B- und/oder spezifischen T-Zellen. IgG-vermittelte Reaktionen, die z.B. eine hämolytische Anämie verursachen können, sind selten. Spezifische IgE können mittels CAP-Technologie nachgewiesen werden. Das Medikament muss an eine Trägersubstanz covalent gebunden werden, was den Nachteil mit sich bringt, dass die entsprechende Bindungsstelle im Medikament für IgE nicht erkennbar ist. Der Basophilenaktivierungstest (BAT) arbeitet meist mit freiem, ungebundenem Medikament. Wie die IgE-Vernetzung stattfindet, ist allerdings unklar. Beide Teste sind nicht genügend sensitiv um den In-vivo-Test (Prick oder i.d.) zu ersetzen. Bei T-Zell-Reaktionen wird in vitro meist die Proliferation der durch das Medikament stimulierten T-Zellen erfasst. Die Blutzellen (antikoaguliertes Blut) sollte innerhalb von 24 h im Labor zur Verarbeitung ankommen, wo die Zellseparation durchgeführt wird, um die Zellen mit dem Medikament zu stimulieren. Diese Stimulation kann durch Messung von Aktivierungsmarker (mittels Flow-Zytometrie), sezernierter Zytokine (ELISA) oder 3H-Thymidin Einbau in die sich teilende Zellen (Lymphozytentransformations- Test, LTT) erfasst werden. Am meisten Erfahrung liegt für den LTT vor. Die Sensitivität wird bei eindeutigen Fällen auf 50 – 70% geschätzt, hängt aber stark vom Krankheitsbild und Medikament ab. Schwere makulopapulöse Reaktionen und DRESS (Drug Rash with Eosinophilia and Systemic Symptoms), AGEP (acute generalized exanthematous pustulosis) sind meist positiv im LTT, aber schwere bullöse Reaktionen (SJS/TEN; Stevens-Johnson Syndrom/toxische epidermale Nekrolyse) werden besser mittels Zytotoxteste und Zytokinsekretion erfasst, da eine T-Zell-Proliferation weniger prominent ist. Trotz der limitierten Sensitivität sind diese Teste gut geeignet um Kreuzreaktionen zu erfassen, bzw. für mechanistische Studien. Da Provokationsteste bei verzögerten Medikamentenallergien nicht zur Verfügung stehen (es ist unklar, wie lange und wie hoch dosiert man das Medikament bei verzögerten Reaktionen geben muss), werden diese Teste in Zukunft eher mehr eingesetzt werden. Wichtig ist, dass sie selten falsch positiv sind, und ein positives Resultat als relevant angesehen werden kann. Für die Abklärung seltener IgG-vermittelter Reaktionen kann man einen modifizierten Coombs-Test versuchen.
Resumo:
Bone-anchored hearing implants (BAHI) are routinely used to alleviate the effects of the acoustic head shadow in single-sided sensorineural deafness (SSD). In this study, the influence of the directional microphone setting and the maximum power output of the BAHI sound processor on speech understanding in noise in a laboratory setting were investigated. Eight adult BAHI users with SSD participated in this pilot study. Speech understanding in noise was measured using a new Slovak speech-in-noise test in two different spatial settings, either with noise coming from the front and noise from the side of the BAHI (S90N0) or vice versa (S0N90). In both spatial settings, speech understanding was measured without a BAHI, with a Baha BP100 in omnidirectional mode, with a BP100 in directional mode, with a BP110 power in omnidirectional and with a BP110 power in directional mode. In spatial setting S90N0, speech understanding in noise with either sound processor and in either directional mode was improved by 2.2-2.8 dB (p = 0.004-0.016). In spatial setting S0N90, speech understanding in noise was reduced by either BAHI, but was significantly better by 1.0-1.8 dB, if the directional microphone system was activated (p = 0.046), when compared to the omnidirectional setting. With the limited number of subjects in this study, no statistically significant differences were found between the two sound processors.
Resumo:
Streptomycin is used in arboriculture to control fire blight. Using sheep as a model, multidrug-resistant bacteria in mammals were found to be selected after the intentional release of streptomycin into the environment. Escherichia coli and Staphylococcus spp. were isolated from the faeces and nasal cavities, respectively, of sheep grazing on a field sprayed with streptomycin at concentrations used in orchards (test group) and on a field without streptomycin (control group). Before the application of streptomycin, the percentage of streptomycin-resistant E. coli isolates in faeces was 15.8% in the control group and 14.7% in the test group. After the application of streptomycin, the overall number of streptomycin-resistant E. coli isolates was significantly higher in the test group (39.9%) than in the control group (22.3%). Streptomycin-resistant Staphylococcus isolates were only detected after the application of streptomycin. Streptomycin resistance was frequently associated with resistance to sulfamethoxazole, ampicillin, tetracycline and chloramphenicol and less frequently to cefotaxime in E. coli, and to tetracycline, fusidic acid and tiamulin in Staphylococcus spp. This study shows that the application of low concentrations of streptomycin on grass, as occurs during the spraying of orchards, selects for multidrug-resistant nasal and enteric bacterial flora, including extended-spectrum beta-lactamase-producing E. coli.
Resumo:
In aviary systems for laying hens, it is important to provide suitable nest access platforms in front of the nests, allowing hens to reach and explore each of the nests easily. This access platform is needed to achieve good nest acceptance by the hens and thereby prevent mislaid eggs. In the present experiment, the behavior of hens using 2 different nest access platforms, a plastic grid and 2 wooden perches, was examined. Furthermore, the nests were placed on both sides of the aviary rack (corridor side and outdoor side), either integrated into the aviary rack itself (integrated nest; IN) or placed on the walls of the pens (wall nest; WN), resulting in a 2 × 2 factorial design Four thousand five hundred white laying hens were housed in 20 test pens. The eggs in the nests and mislaid eggs were collected daily, and the behavior of hens on the nest accesses was filmed during wk 25 and 26, using focal observation and scan sampling methods. More balancing, body contact, and agonistic interactions were expected for nests with perches, whereas more walking and nest inspections were expected for nests with grids. There were more mislaid eggs and balancing found in pens equipped with nests with wooden perches. More agonistic interactions and balancing, less standing, and a longer duration of nest inspection were found with the WN compared with the IN. Interactions between platform design and position of the nests were found for duration of nest visits, body contact, and walking, with the highest amount for WN equipped with plastic grids. Nests on the corridor side were favored by the hens. Nest-related behaviors, such as nest inspection, standing, and walking, decreased over time as did the number of hens on the nest accesses, whereas sitting increased. These results indicate that the hens had more difficulties in gripping the perches as designed. The lower number of hens on the nest access platforms in front of IN may be due to a better distribution around nests and tier changes within the aviary rack. Based on these results, grids rather than perches provide for improved nesting behavior.
Resumo:
Abstract Inhalation of ambient air particles or engineered nanoparticles (NP) handled as powders, dispersions or sprays in industrial processes and contained in consumer products pose a potential and largely unknown risk for incidental exposure. For efficient, economical and ethically sound evaluation of health hazards by inhaled nanomaterials, animal-free and realistic in vitro test systems are desirable. The new Nano Aerosol Chamber for in-vitro Toxicity studies (NACIVT) has been developed and fully characterized regarding its performance. NACIVT features a computer-controlled temperature and humidity conditioning, preventing cellular stress during exposure and allowing long-term exposures. Airborne NP are deposited out of a continuous air stream simultaneously on up to 24 cell cultures on Transwell® inserts, allowing high-throughput screening. In NACIVT, polystyrene as well as silver particles were deposited uniformly and efficiently on all 24 Transwell® inserts. Particle-cell interaction studies confirmed that deposited particles reach the cell surface and can be taken up by cells. As demonstrated in control experiments, there was no evidence for any adverse effects on human bronchial epithelial cells (BEAS-2B) due to the exposure treatment in NACIVT. The new, fully integrated and transportable deposition chamber NACIVT provides a promising tool for reliable, acute and sub-acute dose-response studies of (nano)particles in air-exposed tissues cultured at the air-liquid interface.
Resumo:
Screening tests for drugs of abuse are regularly used in the clinical routine. These tests identify the targeted substances very differently if tests from different manufacturers are used and sometimes also react positive after the intake of drugs which are not intended to be detected. Therefore, implausible results have to be questioned. A test result can be falsely negative, if a patient has taken a compound which is not detected by the antibody used in the test system. Chromatographic confirmation and screening assays are more laborious to perform and more demanding for the interpretation and are therefore only offered by several specialized clinical laboratories. However, their specificity is excellent and many different compounds can be detected depending on the number of compounds which are part of the mass spectra library used. If the clinical evaluation results in the differential diagnosis of an acute intoxication, screening tests for drugs of abuse can help to identify a single compound or a group of substances. The clinical picture, however, can usually not been explained by a qualitative test result. In addition, there are no published data demonstrating that these tests meaningfully influence triage, treatment, diagnosis or further therapy of a poisoned patient. The quantitative determination of specific compounds in the blood allows for example an appraisal of the prognosis and helps to indicate a specific therapy after intake of acetaminophen or methanol. New designer drugs can not at all be detected by the classic screening tests for drugs of abuse. The have to be identified by chromatographic methods.
Resumo:
BACKGROUND & AIMS: Age is frequently discussed as negative host factor to achieve a sustained virological response (SVR) to antiviral therapy of chronic hepatitis C. However, elderly patients often show advanced fibrosis/cirrhosis as known negative predictive factor. The aim of this study was to assess age as an independent predictive factor during antiviral therapy. METHODS: Overall, 516 hepatitis C patients were treated with pegylated interferon-α and ribavirin, thereof 66 patients ≥60 years. We analysed the impact of host factors (age, gender, fibrosis, haemoglobin, previous hepatitis C treatment) and viral factors (genotype, viral load) on SVR per therapy course by performing a generalized estimating equations (GEE) regression modelling, a matched pair analysis and a classification tree analysis. RESULTS: Overall, SVR per therapy course was 42.9 and 26.1%, respectively, in young and elderly patients with hepatitis C virus (HCV) genotypes 1/4/6. The corresponding figures for HCV genotypes 2/3 were 74.4 and 84%. In the GEE model, age had no significant influence on achieving SVR. In matched pair analysis, SVR was not different in young and elderly patients (54.2 and 55.9% respectively; P = 0.795 in binominal test). In classification tree analysis, age was not a relevant splitting variable. CONCLUSIONS: Age is not a significant predictive factor for achieving SVR, when relevant confounders are taken into account. As life expectancy in Western Europe at age 60 is more than 20 years, it is reasonable to treat chronic hepatitis C in selected elderly patients with relevant fibrosis or cirrhosis but without major concomitant diseases, as SVR improves survival and reduces carcinogenesis.
Resumo:
BACKGROUND/OBJECTIVES The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/METHODS Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires. RESULTS The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS The extent of coating loss requires investigating, as do the biological properties of the detached coating. CONCLUSIONS Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.
Resumo:
BACKGROUND There is confusion over the definition of the term "viability state(s)" of microorganisms. "Viability staining" or "vital staining techniques" are used to distinguish live from dead bacteria. These stainings, first established on planctonic bacteria, may have serious shortcomings when applied to multispecies biofilms. Results of staining techniques should be compared with appropriate microbiological data. DISCUSSION Many terms describe "vitality states" of microorganisms, however, several of them are misleading. Authors define "viable" as "capable to grow". Accordingly, staining methods are substitutes, since no staining can prove viability.The reliability of a commercial "viability" staining assay (Molecular Probes) is discussed based on the corresponding product information sheet: (I) Staining principle; (II) Concentrations of bacteria; (III) Calculation of live/dead proportions in vitro. Results of the "viability" kit are dependent on the stains' concentration and on their relation to the number of bacteria in the test. Generally this staining system is not suitable for multispecies biofilms, thus incorrect statements have been published by users of this technique.To compare the results of the staining with bacterial parameters appropriate techniques should be selected. The assessment of Colony Forming Units is insufficient, rather the calculation of Plating Efficiency is necessary. Vital fluorescence staining with Fluorescein Diacetate and Ethidium Bromide seems to be the best proven and suitable method in biofilm research.Regarding the mutagenicity of staining components users should be aware that not only Ethidium Bromide might be harmful, but also a variety of other substances of which the toxicity and mutagenicity is not reported. SUMMARY - The nomenclature regarding "viability" and "vitality" should be used carefully.- The manual of the commercial "viability" kit itself points out that the kit is not suitable for natural multispecies biofilm research, as supported by an array of literature.- Results obtained with various stains are influenced by the relationship between bacterial counts and the amount of stain used in the test. Corresponding vitality data are prone to artificial shifting.- As microbiological parameter the Plating Efficiency should be used for comparison.- Ethidium Bromide is mutagenic. Researchers should be aware that alternative staining compounds may also be or even are mutagenic.