917 resultados para high power energy
Resumo:
A novel single-phase voltage source rectifier capable to achieve High-Power-Factor (HPF) for variable speed refrigeration system application, is proposed in this paper. The proposed system is composed by a single-phase high-power-factor boost rectifier, with two cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the EEC61000-3-2 standards. The digital controller for the output stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at a refrigerator prototype.
Resumo:
This paper is based on the development and experimental analysis of a DCM Boost interleaved converter suitable for application in traction systems of electrical vehicles pulled by electrical motors (Trolleybus), which are powered by urban DC or AC distribution networks. This front-end structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The architecture of proposed converter is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode. Furthermore, the converter can operate as AC-DC converter, or as DC-DC converter providing the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards. The digital controller has been implemented using a low cost FPGA and developed totally using a hardware description language VHDL and fixed point arithmetic. Thus, two control strategies are evaluated considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, the regular PWM modulation and a current correction PWM modulation. In order to verify the feasibility and performance of the proposed system, experimental results from a 15 kW low power scale prototype are presented, operating in DC and AC conditions.
Resumo:
This article shows a transmission line model for simulation of fast and slow transients, applied to symmetrical or asymmetrical configurations. A transmission line model is developed based on lumped elements representation and state-space techniques. The proposed methodology represents a practical procedure to model three-phase transmission lines directly in time domain, without the explicit or implicit use of inverse transforms. In three-phase representation, analysis modal techniques are applied to decouple the phases in their respective propagation modes, using a correction procedure to set a real and constant matrix for untransposed lines with or without vertical symmetry plane. The proposed methodology takes into account the frequency-dependent parameters of the line and in order to include this effect in the state matrices, a fitting procedure is applied. To verify the accuracy of the proposed state-space model in frequency domain, a simple methodology is described based on line distributed parameters and transfer function associated with input/output signals of the lumped parameters representation. In addition, this article proposes the use of a fast and robust integration procedure to solve the state equations, enabling transient and steady-state simulations. The results obtained by the proposed methodology are compared with several established transmission line models in EMTP, taking into account an asymmetrical three-phase transmission line. The principal contribution of the proposed methodology is to handle a steady fundamental signal mixed with fast and slow transients, including impulsive and oscillatory behavior, by a practical procedure applied directly in time domain for symmetrical or asymmetrical representations. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
An efficient heuristic algorithm is presented in this work in order to solve the optimal capacitor placement problem in radial distribution systems. The proposal uses the solution from the mathematical model after relaxing the integrality of the discrete variables as a strategy to identify the most attractive bus to add capacitors to each step of the heuristic algorithm. The relaxed mathematical model is a nonlinear programming problem and is solved using a specialized interior point method, The algorithm still incorporates an additional strategy of local search that enables the finding of a group of quality solutions after small alterations in the optimization strategy. Proposed solution methodology has been implemented and tested in known electric systems getting a satisfactory outcome compared with metaheuristic methods.The tests carried out in electric systems known in specialized literature reveal the satisfactory outcome of the proposed algorithm compared with metaheuristic methods. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
In today`s society the use of so-called information technology and communication (ICT), is promoting a revolution in the forms of teaching and learning through the methods of distance learning courses, especially in higher education. Studies show that students in this way have great difficulties in the learning process, especially when dealing with experimental subjects that require high power of abstraction as chemistry. The goal of this work is to promote improvement in the teaching and learning in the discipline Chemistry of Life offered for the Bachelor`s Degree in Chemistry in distance UFRN. For this we analyzed evidence of the semester 2011.2, in order to identify what are the main difficulties of the students on the assessments. That`s why video lessons related to matters that create the majority of difficulties for students were developed, the final product this work. Being obtained the improvements by video classes in the learning process of the students, from a questionnaire answered by the students in the virtual learning environment, and from their success rate at the end of the course
Resumo:
Objective:Gene expression studies have revealed several molecular subtypes of breast carcinoma with distinct clinical and biological behaviours. DNA microarray studies correlated with immunohistochemical profiling of breast carcinomas using cytokeratin (CK) markers, Her2/neu, oestrogen receptor (ER), and basal myoepithelial cell markers have identified five breast tumour subtypes: (i) luminal A (ER+; Her2/neu-), (ii) luminal B (ER+; Her2/neu+), (iii) Her2 overexpression (ER-; Her2/neu+), (iv) basal-like (ER-; Her2/neu-, CK5/6 and 14+), and (v) negative for all markers. Luminal carcinomas express cytokeratins in a luminal pattern (CK8/18), and the basal-like type expresses CK5/6 and CK14 or basal epithelial cell markers. CK5/6, CK8/18, and smooth muscle actin (SMA) expression were assessed in cell blocks and compared with expression in surgical specimens.Methods:Sixty-two cases of breast carcinoma diagnosed by fine needle aspiration cytology with cell blocks and available surgical specimens were included. Cell blocks containing at least 10 high-power fields each with at least 10 tumour cells and surgical specimens were immunostained for CK5/6, CK8/18 and SMA.Results:Percentage sensitivity, specificity, positive predictive value, negative predictive value and accuracy were, respectively, 77, 100, 100, 92 and 94 for CK5/6; 98, 66, 96, 80 and 95 for CK8/18; and 92, 96, 85, 98 and 95 for SMA.Conclusion:The identification of CK5/6, CK8/18 and SMA by immunohistochemistry in cell blocks can be a reliable method that yields results close to those obtained in surgical specimens, and can contribute to the classification of breast carcinomas with luminal and basal expression patterns, providing helpful information in the choice of treatment and in the evaluation of prognostic and predictive factors.
Resumo:
Objective: This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. Material and Methods: Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke (R) and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37 +/- 1 degrees C, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). Results: High-power-density LED (Delta E=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus - Delta E=2.05; XL 3000 - Delta E=2.28). Coffee (Delta E=8.40; Delta L=-5.21) showed the highest influence on color stability of the studied composite resin. Conclusion: There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We present the measurement of R = B(t -> Wb)/B(t -> Wq) in pp collisions at root s = 1.96 TeV, using 230 pb(-1) of data collected by the DO experiment at the Fermilab Tevatron Collider. We fit simultaneously R and the number (N-tt) of selected top quark pairs (tt), to the number of identified b-quark jets in events with one electron or one muon, three or more jets, and high transverse energy imbalance. To improve sensitivity, kinematical properties of events with no identified b-quark jets are included in the fit. We measure R = 1.03(-0.17)(0.19) (stat + syst), in good agreement with the standard model. We set lower limits of R > 0.61 and vertical bar V-tb vertical bar > 0.78 at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
We present the first experimental discrimination between the 2e/3 and 4e/3 top quark electric charge scenarios, using top quark pairs (t (t) over bar) produced in p (p) over bar collisions at root s =1.96 TeV by the Fermilab Tevatron Collider. We use 370 pb(-1) of data collected by the D0 experiment and select events with at least one high transverse momentum electron or muon, high transverse energy imbalance, and four or more jets. We discriminate between b- and (b) over bar -quark jets by using the charge and momenta of tracks within the jet cones. The data are consistent with the expected electric charge, |q|=2e/3. We exclude, at the 92% C.L., that the sample is solely due to the production of exotic quark pairs Q (Q) over bar with |q|=4e/3. We place an upper limit on the fraction of Q (Q) over bar pairs rho < 0.80 at the 90% C.L.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O objetivo do estudo foi avaliar a deposição de óxido de alumínio no campo operatório do cirurgião-dentista durante a utilização do sistema de abrasão a ar em consultório odontológico, bem como a efetividade da sucção de alta potência na captação desse pó. Por meio de um dispositivo para a coleta das partículas nos locais correspondentes às posições e distâncias de trabalho do profissional, dentes artificiais foram abrasionados. O sistema de sucção empregado para aspiração das partículas foi o de alta potência com sugador de saliva convencional e sugador com abertura ampliada por funil. A mensuração das partículas foi determinada pela quantidade em massa de óxido de alumínio depositada em placas de Petri. Os resultados obtidos por meio de estatística descritiva gráfica revelaram que a maior quantidade de pó se encontrava a 20 cm do operador e na posição de trabalho 9h, quando foi utilizado o sugador de saliva convencional. Uma vez comprovado que a sucção não é totalmente eficiente na aspiração do pó de óxido de alumínio, reforça-se a importância da proteção individual apropriada para o emprego seguro do sistema de abrasão a ar para pacientes e, principalmente, para os profissionais que trabalham com este tipo de tecnologia.