943 resultados para high performance liquid chromatography-inductively coupled plasma-mass sepetrometry
Resumo:
This work shows the chemical characterization of a dye processing plant effluent that was contributing to the mutagenicity previously detected in the Cristais river, São Paulo, Brazil, that had an impact on the quality of the related drinking water. The mutagenic dyes Disperse Blue 373, Disperse Orange 37 and Disperse Violet 93, components of a Black Dye Commercial Product (BDCP) frequently used by the facility, were detected by thin layer chromatography (TLC). The blue and orange dyes were quantified by high performance liquid chromatography (HPLC/DAD) in a raw and treated effluent samples and their contribution to the mutagenicity was calculated based on the potency of each dye for the Salmonella YG1041. In the presence of S9 the Disperse Blue 373 accounted for 2.3% of the mutagenic activity of the raw and 71.5% of the treated effluent. In the absence of S9 the Disperse Blue 373 accounted for 1.3% of the mutagenic activity of the raw and 1.5% of the treated effluent. For the Disperse Orange 37, in the presence of S9, it contributed for 0.5% of the mutagenicity of the raw and 6% of the treated effluent. In the absence of S9; 11.5% and 4.4% of the raw and treated effluent mutagenicity, respectively. The contribution of the Disperse Violet 93 was not evaluated because this compound could not be quantified by HPLC/DAD. Mutagenic and/or carcinogenic aromatic amines were also preliminary detected using gas chromatograph/mass spectrometry in both raw and treated and are probably accounting for part of the observed mutagenicity. The effluent treatment applied by the industry does not seem to remove completely the multagenic compounds. The Salmomella/microsome assay coupled with TLC analysis seems to be an important tool to monitor the efficiency of azo dye processing plant effluent treatments. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A S(+) cetamina é um fármaco amplamente utilizado na medicina para induzir anestesia e a associação com midazolam é empregada para minimizar seus efeitos adversos. Associações medicamentosas podem resultar em interações farmacocinéticas e a disponibilidade de métodos bioanalíticos para a determinação da cetamina em plasma constitui ferramenta útil para a avaliação do perfil cinético do fármaco administrado isoladamente ou em associação. O presente estudo teve como objetivo o desenvolvimento e validação de um método analítico para determinação da cetamina em plasma por cromatografia líquida de alta eficiência (HPLC) e a investigação do perfil farmacocinético da cetamina em quatro cães hígidos da raça Beagle. A S(+) cetamina (10mg/kg) foi administrada pela veia cefálica em dose única isoladamente (protocolo I) ou associada ao midazolam (0.2mg/kg) (protocolo II) em estudo cruzado com intervalo de uma semana para washout. Amostras seriadas de sangue foram coletadas no intervalo de oito horas e analisadas por HPLC para a avaliação do perfil farmacocinético utilizando modelo bicompartimental. O método bioanalítico apresentou limites de confiança aceitáveis para sua aplicação em estudos de farmacocinética e os parâmetros área sob a curva (ASC0-8), volume de distribuição (Vd), clearance total (Clt), meia vida de eliminação (t/12 ß), constante de eliminação (ß), meia vida de distribuição (t1/2α) e constante de distribuição (α) não mostraram diferenças estatísticas significativas entre os grupos (p < 0.05, Wilcoxon). Os resultados obtidos sugerem que a redução dos efeitos colaterais da cetamina decorrente do uso da associação cetamina-midazolam não está relacionada a alterações no perfil farmacocinético da cetamina.
Resumo:
Background and Purpose: The circadian rhythm of melatonin in saliva or plasma, or of the melatonin metabolite 6-sulfatoxymelatonin (a6MTs) in urine, is a defining feature of suprachiasmatic nucleus (SCN) function, the body's endogenous oscillatory pacemaker. The primary objective of this review is to ascertain the clinical benefits and limitations of current methodologies employed for detection and quantification of melatonin in biological fluids and tissues. Data Identification: A search of the English-language literature (Medline) and a systematic review of published articles were carried out. Study Selection: Articles that specified both the methodology for quantifying melatonin and indicated the clinical purpose were chosen for inclusion in the review. Data Extraction: The authors critically evaluated the methodological issues associated with various tools and techniques (e.g. standards, protocols, and procedures). Results of Data Synthesis: Melatonin measurements are useful for evaluating problems related to the onset or offset of sleep and for assessing phase delays or advances of rhythms in entrained individuals. They have also become an important tool for psychiatric diagnosis, their use being recommended for phase typing in patients suffering from sleep and mood disorders. Additionally, there has been a continuous interest in the use of melatonin as a marker for neoplasms of the pineal region. Melatonin decreases such as found with aging are or post pinealectomy can cause alterations in the sleep/wake cycle. The development of sensitive and selective methods for the precise detection of melatonin in tissues and fluids has increasingly been shown to have direct relevance for clinical decision making. Conclusions: Due to melatonin's low concentration, as well as the coexistence of numerous other compounds in the blood, the routine determination of melatonin has been an analytical challenge. The available evidence indicates however that these challenges can be overcome and consequently that evaluation of melatonin's presence and activity can be an accessible and useful tool for clinical diagnosis. © Springer-Verlag 2010.
Resumo:
A HPLC-ESI-IT-MSn method, based on high-performance liquid chromatography coupled to electrospray negative ionization multistage ion trap mass spectrometry, was developed for rapid identification of 24 flavonoid and naphthopyranone compounds. The methanol extracts of the capitulae and scapes of P. chiquitensis exhibited mutagenic activity in the Salmonella/microsome assay, against strain TA97a. © 2013 by the authors.
Resumo:
The purpose of this study was to develop a mucoadhesive stimuli-sensitive drug delivery system for nasal administration of zidovudine (AZT). The system was prepared by formulating a low viscosity precursor of a liquid crystal phase, taking advantage of its lyotropic phase behavior. Flow rheology measurements showed that the formulation composed of PPG-5-CETETH-20, oleic acid and water (55, 30, 15% w/w), denominated P, has Newtonian flow behavior. Polarized light microscopy (PLM) revealed that formulation P is isotropic, whereas its 1:1 (w/w) dilution with artificial nasal mucus (ANM) changed the system to an anisotropic lamellar phase (PD). Oscillatory frequency sweep analysis showed that PD has a high storage modulus (G′) at nasal temperatures. Measurement of the mucoadhesive force against excised porcine nasal mucosa or a mucin disk proved that the transition to the lamellar phase tripled the work of mucoadhesion. Ex vivo permeation studies across porcine nasal mucosa exhibited an 18-fold rise in the permeability of AZT from the formulation. The Weibull mathematical model suggested that the AZT is released by Fickian diffusion mechanisms. Hence, the physicochemical characterization, combined with ex vivo studies, revealed that the PPG-5-CETETH-20, oleic acid, and water formulation could form a mucoadhesive matrix in contact with nasal mucus that promoted nasal absorption of the AZT. For an in vivo assessment, the plasma concentrations of AZT in rats were determined by HPLC method following intravenous and intranasal administration of AZT-loaded P formulation (PA) and AZT solution, respectively, at a dose of 8 mg/kg. The intranasal administration of PA resulted in a fast absorption process (Tmax = 6.7 min). Therefore, a liquid crystal precursor formulation administered by the nasal route might represent a promising novel tool for the systemic delivery of AZT and other antiretroviral drugs. In the present study, the uptake of AZT absorption in the nasal mucosa was demonstrated, providing new foundations for clinical trials in patients with AIDS. © 2012 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Neste estudo foi determinada a relação entre as concentrações plasmáticas e eritrocitárias de quinina em crianças com malária falciparum não complicada, oriundas de área endêmica da Região Amazônica. A quinina foi detrminada por cromatografia líquida de alta eficiência. No estado de equilíbrio, a relação foi 1,89 ± 1,25 variando de 1,05 a 2,34. Estes resultados demonstraram que a quinina não se concentra nos eritrócitos das crianças e caracterizaram a ausência de diferença racial nesta relação.
Resumo:
Dentre as ferramentas para alcançar o tratamento ótimo para a malária, se destaca a monitorização das concentrações dos antimaláricos nos fluídos biológicos. Ao se considerar que o Coartem® é empregado na terapia de primeira linha para o tratamento da malária falciparum, justifica-se a realização deste estudo que objetivou validar metodologia analítica para determinação de lumefantrina em amostras de sangue total, adsorvidas em papel de filtro, e em plasma, por cromatografia líquida de alta eficiência (CLAE), em pacientes com malária por Plasmodium falciparum não complicada, empregando-se extração líquido-líquido. Foram realizados estudos de seletividade, linearidade, curva de calibração, limites de detecção e quantificação, recuperação, precisão intra e inter-ensaio, estabilidade e robustez. As amostras, para o estudo de aplicabilidade do método proposto, foram coletadas de pacientes com malária falciparum utilizando Coartem® (arteméter-20mg + lumefantrina- 120mg) no D3. As condições cromatográficas otimizadas foram: comprimento de onda de 335nm, fluxo 1,2mL/min. e fase móvel composta por acetonitrila-água (60:40, v/v) pH=3,5. A extração líquido-líquido demonstrou ser eficiente, pois a recuperação média foi de 101,3% para plasma e 84,3% para sangue total. O método foi seletivo e linear em intervalo de concentração de 160 a 1760ng/mL. Os limites de detecção e de quantificação foram 32ng/mL e 160ng/mL. O coeficiente de variação médio intra-ensaio, do plasma e sangue total, respectivamente, foram 10,88 e 8,38% e inter-ensaio de 13,21 e 11,78%. O analito demonstrou ser estável em sangue total adsorvido em papel de filtro por até 70 dias. Modificações no pH, fluxo e composição da fase móvel não alteraram significativamente a resolução do analito de interesse, sugerindo uma robustez adequada. O método demonstrou ser eficaz na quantificação de lumefantrina em amostras de sangue total de pacientes com malária falciparum bem como os parâmetros de validação estão de acordo com as recomendações dos órgãos regulamentadores no Brasil.