971 resultados para gastroenterology procedures
Resumo:
PURPOSE Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.
Resumo:
PURPOSE The aim of this study was to analyze the patient pool referred to a specialty clinic for implant surgery over a 3-year period. MATERIALS AND METHODS All patients receiving dental implants between 2008 and 2010 at the Department of Oral Surgery and Stomatology were included in the study. As primary outcome parameters, the patients were analyzed according to the following criteria: age, sex, systemic diseases, and indication for therapy. For the inserted implants, the type of surgical procedure, the types of implants placed, postsurgical complications, and early failures were recorded. A logistic regression analysis was performed to identify possible local and systemic risk factors for complications. As a secondary outcome, data regarding demographics and surgical procedures were compared with the findings of a historic study group (2002 to 2004). RESULTS A total of 1,568 patients (792 women and 776 men; mean age, 52.6 years) received 2,279 implants. The most frequent indication was a single-tooth gap (52.8%). Augmentative procedures were performed in 60% of the cases. Tissue-level implants (72.1%) were more frequently used than bone-level implants (27.9%). Regarding dimensions of the implants, a diameter of 4.1 mm (59.7%) and a length of 10 mm (55.0%) were most often utilized. An early failure rate of 0.6% was recorded (13 implants). Patients were older and received more implants in the maxilla, and the complexity of surgical interventions had increased when compared to the patient pool of 2002 to 2004. CONCLUSION Implant therapy performed in a surgical specialty clinic utilizing strict patient selection and evidence-based surgical protocols showed a very low early failure rate of 0.6%.
Resumo:
BACKGROUND A range of surgical and non-surgical techniques have received increasing attention in recent years in an effort to reduce the duration of a course of orthodontic treatment. Various surgical techniques have been used; however, uncertainty exists in relation to the effectiveness of these procedures and the possible adverse effects related to them. OBJECTIVES To assess the effects of surgically assisted orthodontics on the duration and outcome of orthodontic treatment. SEARCH METHODS We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 10 September 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 8), MEDLINE via OVID (1946 to 10 September 2014), EMBASE via OVID (1980 to 10 September 2014), LILACS via BIREME (1980 to 10 September 2014), metaRegister of Controlled Trials (to 10 September 2014), ClinicalTrials.gov (to 10 September 2014), and the World Health Organization (WHO) International Clinical Trials Registry Platform (to 10 September 2014). We checked the reference lists of all trials identified for further studies. There were no restrictions regarding language or date of publication in the electronic searches. SELECTION CRITERIA Randomised controlled trials (RCTs) evaluating the effect of surgical adjunctive procedures for accelerating tooth movement compared with conventional treatment (no surgical adjunctive procedure). DATA COLLECTION AND ANALYSIS At least two review authors independently assessed the risk of bias in the trials and extracted data. We used the fixed-effect model and expressed results as mean differences (MD) with 95% confidence intervals (CI). We investigated heterogeneity with reference to both clinical and methodological factors. MAIN RESULTS We included four RCTs involving a total of 57 participants ranging in age from 11 to 33 years. The interventions evaluated were corticotomies to facilitate orthodontic space closure or alignment of an ectopic maxillary canine, with the effect of repeated surgical procedures assessed in one of these studies. The studies did not report directly on the primary outcome as prespecified in our protocol: duration of orthodontic treatment, number of visits during active treatment (scheduled and unscheduled) and duration of visits. The main outcome assessed within the trials was the rate of tooth movement, with periodontal effects assessed in one trial and pain assessed in one trial. A maximum of just three trials with small sample sizes were available for each comparison and outcome. We assessed all of the studies as being at unclear risk of bias.Tooth movement was found to be slightly quicker with surgically assisted orthodontics in comparison with conventional treatment over periods of one month (MD 0.61 mm; 95% CI 0.49 to 0.72; P value < 0.001) and three months (MD 2.03 mm, 95% CI 1.52 to 2.54; P value < 0.001). Our results and conclusions should be interpreted with caution given the small number of included studies. Information on adverse events was sought; however, no data were reported in the included studies. AUTHORS' CONCLUSIONS This review found that there is limited research concerning the effectiveness of surgical interventions to accelerate orthodontic treatment, with no studies directly assessing our prespecified primary outcome. The available evidence is of low quality, which indicates that further research is likely to change the estimate of the effect. Based on measured outcomes in the short-term, these procedures do appear to show promise as a means of accelerating tooth movement. It is therefore possible that these procedures may prove useful; however, further prospective research comprising assessment of the entirety of treatment with longer follow-up is required to confirm any possible benefit.
Resumo:
Bovine tuberculosis (bTB) is a (re-)emerging disease in European countries, including Switzerland. This study assesses the seroprevalence of infection with Mycobacterium bovis and closely related agents in wild boar (Sus scrofa) in Switzerland, because wild boar are potential maintenance hosts of these pathogens. The study employs harmonised laboratory methods to facilitate comparison with the situation in other countries. Eighteen out of 743 blood samples tested seropositive (2.4%, CI: 1.5-3.9%) by ELISA, and the results for 61 animals previously assessed using culture and PCR indicated that this serological test was not 100% specific for M. bovis, cross-reacting with M. microti. Nevertheless, serology appears to be an appropriate test methodology in the harmonisation of wild boar testing throughout Europe. In accordance with previous findings, the low seroprevalence found in wild boar suggests wildlife is an unlikely source of the M. bovis infections recently detected in cattle in Switzerland. This finding contrasts with the epidemiological situation pertaining in southern Spain.
Resumo:
In epidemiology literature, it is often required to investigate the relationships between means where the levels of experiment are actually monotone sets forming a partition on the range of sampling values. With this need, the analysis of these group means is generally performed using classical analysis of variance (ANOVA). However, this method has never been challenged. In this dissertation, we will formulate and present our examination of its validity. First, the classical assumptions of normality and constant variance are not always true. Second, under the null hypothesis of equal means, the test statistic for the classical ANOVA technique is still valid. Third, when the hypothesis of equal means is rejected, the classical analysis techniques for hypotheses of contrasts are not valid. Fourth, under the alternative hypothesis, we can show that the monotone property of levels leads to the conclusion that the means are monotone. Fifth, we propose an appropriate method for handing the data in this situation. ^
Resumo:
Background. Childhood immunization programs have dramatically reduced the morbidity and mortality associated with vaccine-preventable diseases. Proper documentation of immunizations that have been administered is essential to prevent duplicate immunization of children. To help improve documentation, immunization information systems (IISs) have been developed. IISs are comprehensive repositories of immunization information for children residing within a geographic region. The two models for participation in an IIS are voluntary inclusion, or "opt-in," and voluntary exclusion, or "opt-out." In an opt-in system, consent must be obtained for each participant, conversely, in an opt-out IIS, all children are included unless procedures to exclude the child are completed. Consent requirements for participation vary by state; the Texas IIS, ImmTrac, is an opt-in system.^ Objectives. The specific objectives are to: (1) Evaluate the variance among the time and costs associated with collecting ImmTrac consent at public and private birthing hospitals in the Greater Houston area; (2) Estimate the total costs associated with collecting ImmTrac consent at selected public and private birthing hospitals in the Greater Houston area; (3) Describe the alternative opt-out process for collecting ImmTrac consent at birth and discuss the associated cost savings relative to an opt-in system.^ Methods. Existing time-motion studies (n=281) conducted between October, 2006 and August, 2007 at 8 birthing hospitals in the Greater Houston area were used to assess the time and costs associated with obtaining ImmTrac consent at birth. All data analyzed are deidentified and contain no personal information. Variations in time and costs at each location were assessed and total costs per child and costs per year were estimated. The cost of an alternative opt-out system was also calculated.^ Results. The median time required by birth registrars to complete consent procedures varied from 72-285 seconds per child. The annual costs associated with obtaining consent for 388,285 newborns in ImmTrac's opt-in consent process were estimated at $702,000. The corresponding costs of the proposed opt-out system were estimated to total $194,000 per year. ^ Conclusions. Substantial variation in the time and costs associated with completion of ImmTrac consent procedures were observed. Changing to an opt-out system for participation could represent significant cost savings. ^
Resumo:
High levels of poverty and unemployment, and low levels of health insurance coverage may pose barriers to obtaining cardiac care by Mexican Americans. We undertook this study to investigate differences in the use of invasive myocardial revascularization procedures received within the 4-month period following hospitalization for a myocardial infarction (MI) between Mexican Americans and non-Hispanic whites in the Corpus Christi Heart Project (CCHP). The CCHP is a population-based surveillance program for hospitalized MI, percutaneous transluminal coronary angioplasty (PTCA), and aortocoronary bypass surgery (ACBS). Medical record data were available for 1706 patients identified over a three-year period. Mexican Americans had significantly lower rates of receiving a PTCA following MI than non-Hispanic Whites (RR: 0.56, 95% CI: 0.44-0.70). No meaningful ethnic difference was seen in the rates of ACBS use. History of PTCA use appeared to interact with ethnicity. Among patients without a history of PTCA use, Mexican Americans were less likely to receive a PTCA than non-Hispanic whites (RR: 0.59; 95% CI: 0.46-0.76). Among patients with a history of PTCA use, however, Mexican Americans were more likely to receive a PTCA than non-Hispanic whites (RR: 1.47; 95% CI: 0.75-2.87).^ Differences in the effectiveness of a first-time PTCA and first-time ACBS between Mexican Americans and non-Hispanic whites in the CCHP were also investigated. Mexican Americans were more likely to receive a 2nd PTCA (RR: 1.56, 95% CI: 1.11-2.17) and suffer a subsequent MI (RR: 1.42, 95% CI: 1.03-1.96) following a first-time PTCA than non-Hispanic whites. No meaningful ethnic differences were found in the rates of death and rates of ACBS following a first-time PTCA. Also, no significant ethnic differences were found in the rates of any of the events following a first-time ACBS. After adjusting for potential demographic, socioeconomic, clinical and angiographic confounders using Cox regression analysis, Mexican Americans were still more likely to receive a 2nd PTCA (HR: 1.38; 95% CI: 0.99-1.93) following a first-time PTCA than non-Hispanic whites. A significant difference in the rates of a subsequent MI following a first-time PTCA persisted (HR: 1.39, 95% CI: 1.01-1.93). (Abstract shortened by UMI.) ^
Resumo:
Conservative procedures in low-dose risk assessment are used to set safety standards for known or suspected carcinogens. However, the assumptions upon which the methods are based and the effects of these methods are not well understood.^ To minimize the number of false-negatives and to reduce the cost of bioassays, animals are given very high doses of potential carcinogens. Results must then be extrapolated to much smaller doses to set safety standards for risks such as one per million. There are a number of competing methods that add a conservative safety factor into these calculations.^ A method of quantifying the conservatism of these methods was described and tested on eight procedures used in setting low-dose safety standards. The results using these procedures were compared by computer simulation and by the use of data from a large scale animal study.^ The method consisted of determining a "true safe dose" (tsd) according to an assumed underlying model. If one assumed that Y = the probability of cancer = P(d), a known mathematical function of the dose, then by setting Y to some predetermined acceptable risk, one can solve for d, the model's "true safe dose".^ Simulations were generated, assuming a binomial distribution, for an artificial bioassay. The eight procedures were then used to determine a "virtual safe dose" (vsd) that estimates the tsd, assuming a risk of one per million. A ratio R = ((tsd-vsd)/vsd) was calculated for each "experiment" (simulation). The mean R of 500 simulations and the probability R $<$ 0 was used to measure the over and under conservatism of each procedure.^ The eight procedures included Weil's method, Hoel's method, the Mantel-Byran method, the improved Mantel-Byran, Gross's method, fitting a one-hit model, Crump's procedure, and applying Rai and Van Ryzin's method to a Weibull model.^ None of the procedures performed uniformly well for all types of dose-response curves. When the data were linear, the one-hit model, Hoel's method, or the Gross-Mantel method worked reasonably well. However, when the data were non-linear, these same methods were overly conservative. Crump's procedure and the Weibull model performed better in these situations. ^
Resumo:
We report oxygen and carbon stable isotope analyses of foraminifers, primarily planktonic, sampled at low resolution in the Cretaceous and Paleogene sections from Sites 1257, 1258, and 1260. Data from two samples from Site 1259 are also reported. The very low resolution of the data only allows us to detect climate-driven isotopic events on the timescale of more than 500 k.y. A several million-year-long interval of overall increase in planktonic 18O is seen in the Cenomanian at Site 1260. Before and after this interval, foraminifers from Cenomanian and Turonian black shales have d18O values in the range -4.2 per mil to -5.0 per mil, suggestive of upper ocean temperatures higher than modern tropical values. The d18O values of upper ocean dwelling Paleogene planktonics exhibit a long-term increase from the early Eocene to the middle Eocene. During shipboard and postcruise processing, it proved difficult to extract well-preserved foraminifer tests from black shales by conventional techniques. Here, we report results of a test of procedures for cleaning foraminifers in Cretaceous organic-rich mudstone sediments using various combinations of soaking in bleach, Calgon/hydrogen peroxide, or Cascade, accompanied by drying, repeat soaking, or sonication. A procedure that used 100% bleach, no detergent, and no sonication yielded the largest number of clean, whole individual foraminifers with the shortest preparation time. We found no significant difference in d18O or d13C values among sets of multiple samples of the planktonic foraminifer Whiteinella baltica extracted following each cleaning procedure.
Resumo:
BACKGROUND Double-checking is widely recommended as an essential method to prevent medication errors. However, prior research has shown that the concept of double-checking is not clearly defined, and that little is known about actual practice in oncology, for example, what kind of checking procedures are applied. OBJECTIVE To study the practice of different double-checking procedures in chemotherapy administration and to explore nurses' experiences, for example, how often they actually find errors using a certain procedure. General evaluations regarding double-checking, for example, frequency of interruptions during and caused by a check, or what is regarded as its essential feature was assessed. METHODS In a cross-sectional survey, qualified nurses working in oncology departments of 3 hospitals were asked to rate 5 different scenarios of double-checking procedures regarding dimensions such as frequency of use in practice and appropriateness to prevent medication errors; they were also asked general questions about double-checking. RESULTS Overall, 274 nurses (70% response rate) participated in the survey. The procedure of jointly double-checking (read-read back) was most commonly used (69% of respondents) and rated as very appropriate to prevent medication errors. Jointly checking medication was seen as the essential characteristic of double-checking-more frequently than 'carrying out checks independently' (54% vs 24%). Most nurses (78%) found the frequency of double-checking in their department appropriate. Being interrupted in one's own current activity for supporting a double-check was reported to occur frequently. Regression analysis revealed a strong preference towards checks that are currently implemented at the responders' workplace. CONCLUSIONS Double-checking is well regarded by oncology nurses as a procedure to help prevent errors, with jointly checking being used most frequently. Our results show that the notion of independent checking needs to be transferred more actively into clinical practice. The high frequency of reported interruptions during and caused by double-checks is of concern.
Resumo:
A particle accelerator is any device that, using electromagnetic fields, is able to communicate energy to charged particles (typically electrons or ionized atoms), accelerating and/or energizing them up to the required level for its purpose. The applications of particle accelerators are countless, beginning in a common TV CRT, passing through medical X-ray devices, and ending in large ion colliders utilized to find the smallest details of the matter. Among the other engineering applications, the ion implantation devices to obtain better semiconductors and materials of amazing properties are included. Materials supporting irradiation for future nuclear fusion plants are also benefited from particle accelerators. There are many devices in a particle accelerator required for its correct operation. The most important are the particle sources, the guiding, focalizing and correcting magnets, the radiofrequency accelerating cavities, the fast deflection devices, the beam diagnostic mechanisms and the particle detectors. Most of the fast particle deflection devices have been built historically by using copper coils and ferrite cores which could effectuate a relatively fast magnetic deflection, but needed large voltages and currents to counteract the high coil inductance in a response in the microseconds range. Various beam stability considerations and the new range of energies and sizes of present time accelerators and their rings require new devices featuring an improved wakefield behaviour and faster response (in the nanoseconds range). This can only be achieved by an electromagnetic deflection device based on a transmission line. The electromagnetic deflection device (strip-line kicker) produces a transverse displacement on the particle beam travelling close to the speed of light, in order to extract the particles to another experiment or to inject them into a different accelerator. The deflection is carried out by the means of two short, opposite phase pulses. The diversion of the particles is exerted by the integrated Lorentz force of the electromagnetic field travelling along the kicker. This Thesis deals with a detailed calculation, manufacturing and test methodology for strip-line kicker devices. The methodology is then applied to two real cases which are fully designed, built, tested and finally installed in the CTF3 accelerator facility at CERN (Geneva). Analytical and numerical calculations, both in 2D and 3D, are detailed starting from the basic specifications in order to obtain a conceptual design. Time domain and frequency domain calculations are developed in the process using different FDM and FEM codes. The following concepts among others are analyzed: scattering parameters, resonating high order modes, the wakefields, etc. Several contributions are presented in the calculation process dealing specifically with strip-line kicker devices fed by electromagnetic pulses. Materials and components typically used for the fabrication of these devices are analyzed in the manufacturing section. Mechanical supports and connexions of electrodes are also detailed, presenting some interesting contributions on these concepts. The electromagnetic and vacuum tests are then analyzed. These tests are required to ensure that the manufactured devices fulfil the specifications. Finally, and only from the analytical point of view, the strip-line kickers are studied together with a pulsed power supply based on solid state power switches (MOSFETs). The solid state technology applied to pulsed power supplies is introduced and several circuit topologies are modelled and simulated to obtain fast and good flat-top pulses.