960 resultados para femtosecond pulses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

133 p.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis details the design and applications of a terahertz (THz) frequency comb spectrometer. The spectrometer employs two offset locked Ti:Sapphire femtosecond oscillators with repetition rates of approximately 80 MHz, offset locked at 100 Hz to continuously sample a time delay of 12.5 ns at a maximum time delay resolution of 15.6 fs. These oscillators emit continuous pulse trains, allowing the generation of a THz pulse train by the master, or pump, oscillator and the sampling of this THz pulse train by the slave, or probe, oscillator via the electro-optic effect. Collecting a train of 16 consecutive THz pulses and taking the Fourier transform of this pulse train produces a decade-spanning frequency comb, from 0.25 to 2.5 THz, with a comb tooth width of 5 MHz and a comb tooth spacing of ~80 MHz. This frequency comb is suitable for Doppler-limited rotational spectroscopy of small molecules. Here, the data from 68 individual scans at slightly different pump oscillator repetition rates were combined, producing an interleaved THz frequency comb spectrum, with a maximum interval between comb teeth of 1.4 MHz, enabling THz frequency comb spectroscopy.

The accuracy of the THz frequency comb spectrometer was tested, achieving a root mean square error of 92 kHz measuring selected absorption center frequencies of water vapor at 10 mTorr, and a root mean square error of 150 kHz in measurements of a K-stack of acetonitrile. This accuracy is sufficient for fitting of measured transitions to a model Hamiltonian to generate a predicted spectrum for molecules of interest in the fields of astronomy and physical chemistry. As such, the rotational spectra of methanol and methanol-OD were acquired by the spectrometer. Absorptions from 1.3 THz to 2.0 THz were compared to JPL catalog data for methanol and the spectrometer achieved an RMS error of 402 kHz, improving to 303 kHz when excluding low signal-to-noise absorptions. This level of accuracy compares favorably with the ~100 kHz accuracy achieved by JPL frequency multiplier submillimeter spectrometers. Additionally, the relative intensity performance of the THz frequency comb spectrometer is linear across the entire decade-spanning bandwidth, making it the preferred instrument for recovering lineshapes and taking absolute intensity measurements in the THz region. The data acquired by the Terahertz Frequency Comb Spectrometer for methanol-OD is of comparable accuracy to the methanol data and may be used to refine the fit parameters for the predicted spectrum of methanol-OD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose and demonstrate a switchable dual-wavelength erbium-doped fibre ring laser. Competition between the lasing wavelengths in erbium-doped fibre laser at room temperature is suppressed by incorporating a two-channel fibre Bragg grating (TC-FBG), which consists of two highly localized sub-gratings fabricated by femtosecond laser in single mode fibre. Wavelengths and polarization states of the lasing lines are selected by the TC-FBG. Laser output can be switched between single- and dual-wavelength operations by simply adjusting the polarization controller. Stable dual-wavelength output is verified at room temperature with a power fluctuation less than 0.27 dB, and wavelength fluctuation less than 0.004 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Es ist ein lang gehegter Traum in der Chemie, den Ablauf einer chemischen Reaktion zu kontrollieren und das Aufbrechen und Bilden chemischer Bindungen zu steuern. Diesem Ziel verschreibt sich auch das Forschungsgebiet der Femtochemie. Hier werden Femtosekunden Laserpulse eingesetzt um auf dem Quantenlevel molekulare Dynamiken auf ihren intrinsischen Zeitskalen zu kontrollieren und das System selektiv und effizient von einem Anfangs- in einen Zielzustand zu überführen. Der Wunsch, mit geformten Femtosekunden Laserpulsen Kontrolle über transiente Dynamiken und finale Populationen auszuüben, zu beobachten und zu verstehen, bildet auch die Motivation für diese Arbeit. Hierzu wurden mit Hilfe der Photoelektronenspektroskopie Untersuchungen zur Wechselwirkung atomarer und molekularer Prototypsysteme mit intensiven, geformten Femtosekunden Laserpulsen durchgeführt. Die Verwendung von Modelsystemen ermöglicht es, grundlegende Mechanismen der kohärenten Kontrolle in intensiven Laserfeldern zu analysieren, ohne dass sie durch komplexe Wechselwirkungen verschleiert werden. Zunächst wurde die Wechselwirkung von Kaliumatomen mit gechirpten Femtosekunden Laserpulsen untersucht. In den Experimenten wurden sowohl transiente Dynamiken als auch die Endbesetzungen der elektronischen Zustände abgebildet. In den folgenden Experimenten wurde das Quantenkontrollszenario SPODS auf die gekoppelte Elektronen-Kern-Dynamik in Molekülen übertragen. Die Kontrolle basiert auf der Erzeugung und Manipulation von Ladungsoszillationen durch Pulssequenzen. Der letzte Teil widmet sich der Entwicklung adiabatischer Kontrollmechanismen in Molekülen. Bei den Experimenten wurden gechirpte Airypulse eingesetzt um robuste Starkfeldanregung in molekularen Systemen zu induzieren. In Zukunft wird die Erforschung immer komplexerer Moleküle im Rahmen der transienten Kontrolle im Fokus stehen. Dabei werden nicht nur die effiziente Besetzung gebundener Zustände von Interesse sein, sondern auch die gezielte Dissoziation in spezifische Fragmente, photoinduzierte Isomerisierungsreaktionen oder die Kontrolle über transiente Dynamiken, die Einfluss auf andere molekulare Eigenschaften haben. Vor dem Hintergrund dieses übergeordneten Wunsches, photochemische Reaktionen immer komplexerer Moleküle, bis hin zu großen, biologisch relevanten Molekülen, zu kontrollieren, ist es umso wichtiger, die zugrundeliegenden Anregungsmechanismen in einfachen Systemen nachzuvollziehen. In den hier präsentierten Experimenten wurde gezeigt, wie die simultane Beobachtung der bekleideten und der stationären Zustände in atomaren Systemen zu einem umfassenden Bild der lichtinduzierte Dynamiken führen kann. Die gewonnenen Erkenntnisse können auf die Steuerung gekoppelter Dynamiken übertragen werden, durch die Kontrolle auch in molekularen Systemen möglich wird.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ca(2+)/calmodulin-dependent protein kinase II (CaMKII) functions both in regulation of insulin secretion and neurotransmitter release through common downstream mediators. Therefore, we hypothesized that pancreatic ß-cells acquire and store the information contained in calcium pulses as a form of metabolic memory, just as neurons store cognitive information. To test this hypothesis, we developed a novel paradigm of pulsed exposure of ß-cells to intervals of high glucose, followed by a 24-h consolidation period to eliminate any acute metabolic effects. Strikingly, ß-cells exposed to this high-glucose pulse paradigm exhibited significantly stronger insulin secretion. This metabolic memory was entirely dependent on CaMKII. Metabolic memory was reflected on the protein level by increased expression of proteins involved in glucose sensing and Ca(2+)-dependent vesicle secretion, and by elevated levels of the key ß-cell transcription factor MAFA. In summary, like neurons, human and mouse ß-cells are able to acquire and retrieve information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new species of Pseudopaludicola is described from human-altered areas originally covered by Semideciduous Forest in northwestern state of São Paulo, southeastern Brazil. Morphologically, the new species differs from four species belonging to the P. pusilla group by the absence of either T-shaped terminal phalanges or toe tips expanded, and from all other congeners except P. canga and P. facureae by possessing an areolate vocal sac, with dark reticulation. The higher duration (300-700 ms) of each single, pulsed note (9-36 nonconcatenated pulses) that compose the call in the new species distinguishes it from all other 14 species of Pseudopaludicola with calls already described (10-290 ms). Absence of harmonics also differ the advertisement call of the new species from the call of its sister species P. facureae, even though these two species presented unexpected low genetic distances. Although we could not identify any single morphological character distinguishing the new species from P. facureae, a PCA and DFA performed using 12 morphometric variables evidenced significant size differences between these two species. 

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanically evoked reflexes have been postulated to be less sensitive to presynaptic inhibition (PSI) than the H-reflex. This has implications on investigations of spinal cord neurophysiology that are based on the T-reflex. Preceding studies have shown an enhanced effect of PSI on the H-reflex when a train of ~10 conditioning stimuli at 1 Hz was applied to the nerve of the antagonist muscle. The main questions to be addressed in the present study are if indeed T-reflexes are less sensitive to PSI and whether (and to what extent and by what possible mechanisms) the effect of low frequency conditioning, found previously for the H-reflex, can be reproduced on T-reflexes from the soleus muscle. We explored two different conditioning-to-test (C-T) intervals: 15 and 100 ms (corresponding to D1 and D2 inhibitions, respectively). Test stimuli consisted of either electrical pulses applied to the posterior tibial nerve to elicit H-reflexes or mechanical percussion to the Achilles tendon to elicit T-reflexes. The 1 Hz train of conditioning electrical stimuli delivered to the common peroneal nerve induced a stronger effect of PSI as compared to a single conditioning pulse, for both reflexes (T and H), regardless of C-T-intervals. Moreover, the conditioning train of pulses (with respect to a single conditioning pulse) was proportionally more effective for T-reflexes as compared to H-reflexes (irrespective of the C-T interval), which might be associated with the differential contingent of Ia afferents activated by mechanical and electrical test stimuli. A conceivable explanation for the enhanced PSI effect in response to a train of stimuli is the occurrence of homosynaptic depression at synapses on inhibitory interneurons interposed within the PSI pathway. The present results add to the discussion of the sensitivity of the stretch reflex pathway to PSI and its functional role.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbon and nitrogen biogeochemical cycles in savannas are strongly regulated by the seasonal distribution of precipitation and pulses of nutrients released during the wetting of the dry soil and are critical to the dynamics of microorganisms and vegetation. The objective of this study was to investigate the spatial and temporal variability of C and N isotope ratios as indicators of the cycling of these elements in a cerrado sensu stricto area, within a protected area in a State Park in the state of São Paulo, Brazil. The foliar δ13C and δ15N values varied from -33.6 to -24.4 ‰ and -2.5 to 4.5 ‰, respectively. The δ13C values showed a consistent relationship with canopy height, revealing the importance of structure of the canopy over the C isotopic signature of the vegetation. Carbon isotopic variations associated with the length of the dry season indicated the importance of recent fixed C to the integrated isotopic signature of the leaf organic C. The studied Cerrado species showed a depleted foliar δ15N, but a wide range of foliar Nitrogen with no difference among canopy heights. However, seasonal variability was observed, with foliar δ15N values being higher in the transition period between dry and rainy seasons. The variation of the foliar C and N isotope ratios presented here was consistent with highly diverse vegetation with high energy available but low availability of water and N.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Er:YAG laser has been studied as a potential tool for restorative dentistry due to its ability to selectively remove oral hard tissue with minimal or no thermal damage to the surrounding tissues. The purpose of this study was to evaluate in vitro the tensile bond strength (TBS) of an adhesive/composite resin system to human enamel surfaces treated with 37% phosphoric acid, Er:YAG laser (lambda=2.94 mum) with a total energy of 16 J (80 mJ/pulse, 2Hz, 200 pulses, 250 ms pulse width), and Er:YAG laser followed by phosphoric acid etching. Analysis of the treated surfaces was performed by scanning electron microscopy (SEM) to assess morphological differences among the groups. TBS means (in MPa) were as follows: Er:YAG laser + acid (11.7 MPa) > acid (8.2 MPa) > Er:YAG laser (6.1 MPa), with the group treated with laser+acid being significantly from the other groups (p=0.0006 and p= 0.00019, respectively). The groups treated with acid alone and laser alone were significantly different from each other (p=0.0003). The SEM analysis revealed morphological changes that corroborate the TBS results, suggesting that the differences in TBS means among the groups are related to the different etching patterns produced by each type of surface treatment. The findings of this study indicate that the association between Er:YAG laser and phosphoric acid can be used as a valuable resource to increase bond strength to laser-prepared enamel.