968 resultados para endoscopic ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound effects on the release and activity of invertase from Aspergillus niger cultivated in a medium containing sucrose and peptone and in another with sugar-cane molasses and peptone were investigated. Irradiation was conducted for periods of 2 - 10 min. with waves of amplitude 20 and 40 using an ultrasound processor of 20 kHz. Product formation was determined as reducing equivalents formed by time units using 3,5-dinitrosalicylic acid. Total and specific activities of the culture supernatants were compared in the presence and absence of sonication. Both amplitudes promoted a significant increase of total invertase activity in the time periods investigated and the highest values were obtained with an amplitude of 20. Ultrasound irradiation caused cell disruption, thus releasing invertase and, after 4 min, activation of the enzyme also occurred. The best conditions for production, extraction and activation of invertase were in molasses medium containing peptone and irradiation with ultrasound waves at 20 for 8 min. This method showed high efficiency for the extraction and activation of invertase from A. niger as well as a great potential for use in industrial processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cirurgia endoscópica por orifícios naturais (NOTES) constitui um acesso cirúrgico relativamente novo para abordagem minimamente invasiva, a qual vem sendo amplamente estudada na medicina humana. Porém, poucos estudos envolvendo sua aplicação na prática cirúrgica de pequenos animais foram realizados até o momento. O objetivo do presente estudo foi avaliar a factibilidade da ovário-histerectomia transvaginal por NOTES pura em cadelas. Cinco cadelas foram avaliadas. A cavidade abdominal foi acessada por um trocarte de 11mm introduzido por uma incisão vaginal. Empregando-se um endoscópio rígido com canal de trabalho, os pedículos ovarianos foram coagulados e seccionados usando-se diatermia bipolar. O corno uterino foi tracionado para o interior do trocarte e exteriorizado juntamente com a cânula. O corpo e vasos uterinos foram coagulados ou ligados com sutura. O coto uterino foi reposicionado na cavidade abdominal e o pneumoperitônio, drenado. O procedimento foi realizado com sucesso em quatro das cinco cadelas. Na primeira tentativa, houve conversão para uma técnica de NOTES-híbrida, devido à quebra de uma pinça de coagulação. O tempo cirúrgico médio foi 52,1 (DP±11,5 minutos) para a técnica de NOTES pura. A OHE por NOTES pura é factível em cadelas, sem resultar em complicações maiores e proporcionando excelente recuperação pós-operatória.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A paca é um roedor sul-americano cujo manejo, tranqüilização ou anestesia oferece um grande campo de pesquisa devido aos poucos artigos existentes. Doze pacas fêmeas adultas foram utilizadas, mantidas separadas em seis baias, sendo capturadas com um puçá de polipropileno e levadas a uma sala na qual se realizava a tricotomia abdominal. Após, os animais eram colocados em uma gaiola de ferro de compressão lateral. A sessão de ultra-sonografia era realizada em modo B com um transdutor setorial eletrônico de 5,0 e 7,5 MHz. Para a diminuição do estresse causado pelos procedimentos, a tranqüilização das fêmeas era realizada com diazepam e maleato de midazolam por via oral. Ambos demonstraram-se efetivos na tranqüilização das pacas previamente e durante as sessões, sendo que o maleato de midazolam proporcionou um melhor manejo dos animais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple calorimetric method was employed to study the kinetics of the hydrolysis of the solventless TMOS-water mixtures, under ultrasound stimulation, as a function of the concentration of oxalic acid. The reaction rates were obtained, in relative units, from the measured thermal peak of the reaction as a non-separated function of both the sonication time and the instantaneous temperature of the medium. For concentrations of oxalic acid below 0.01 M, polycondensation reaction starts before complete hydrolysis. For concentrations of oxalic acid above 0.01 M, hydrolysis is complete and, in addition, the inverse of the time, as measured from the starting of ultrasound action until the maximum hydrolysis heat release, was found to be a reasonable relative measure of the average hydrolysis rate constant. The average hydrolysis rate constant was found to be proportional to the square root of the molar concentration of the oxalic acid. This result is in agreement with the literature if we assume small dissociation degree for the catalyst in such a solventless alkoxyde-water medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim the aim of this study was to evaluate the efficacy of ultrasound in cleaning the surface of stainless steel and Ni-Ti endodontic instruments.Methodology Twenty nickel-titanium instruments (10 Quantec files and 10 Nitiflex) and 20 stainless steel K-files (10 Maillefer-Dentsply and 10 Moyco Union Broach) were removed from their original packages and evaluated using a scanning electron microscope. Scores were given for the presence of residues on the surface or the instruments. The instruments were then cleaned in an ultrasonic bath containing only distilled water or detergent solution for 15 min, and re-evaluated, using scanning electron microscopy.Results Before cleaning, a greater amount of metallic debris was observed on the nickel-titanium Quantec instruments (P < 0.05), when compared to those made of stainless steel. Statistical analysis showed that the use of ultrasound was effective for cleaning the instruments, regardless of the irrigating solution or the instruments type (P < 0.05).Conclusions the use of ultrasound proved to be an efficient method for the removal of metallic particles from the surface of stainless steel and Ni-Ti endodontic instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ultrasound stimulated and oxalic acid-catalyzed hydrolysis of tetramethoxysilane (TMOS) was studied by means of a heat flux calorimetric method as a function of the initial water/TMOS molar ratio (r) ranging from 2 to 10. The method is based on the time recording of the hydrolysis exothermic heat peak. which takes place in acidulated heterogeneous water-TMOS mixtures under ultrasonic stimulation, accounting for the instantaneous hydrolysis rate. The hydrolysis rate increases from zero up to a maximum value during the heterogeneous step of the process and then diminishes naturally according to the reactant consumption. The total hydrolyzed quantity was found to be slightly increasing with r. The immiscibility gap of the TMOS- water system in the presence of the hydrolysis products has been inferred from the evaluation of the reacted quantity during the heterogeneous step of the reaction and it has been represented in a ternary diagram in the studied r-range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acid and ultrasound catalyzed hydrolysis of solventless TEOS-water mixtures are studied, as a function of the initial additions of ethanol to the mixtures, by means of flux calorimetry measurements. A device was specially designed for this purpose. Under acid conditions, our proposed method has been able to resolve hydrolysis from other condensation reactions, by detecting the exothermal hydrolysis reaction heat. The process has been explained by a dissolution and reaction mechanism. Ultrasound forces the dissolution process to start the reaction. The alcohol produced in the reaction helps the dissolution process to further enhance the hydrolysis. Initial amounts of pure ethanol added to the mixtures shorten the start time of the reaction, due to an additional effect of dissolution, and diminish the reaction rate, as a result of the solvent dilution effect. Our dissolution and reaction mechanism modeling describes the main points arising from the experimental data and yields k(H) = 0.24 M(-1) min(-1) for the second-order hydrolysis rate constant at 39 degrees C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pure and mixed tetramethoxysilane (TMOS) and tetraethoxysilane (TEOS) were hydrolyzed at 35 degrees C, using oxalic acid as a catalyst and ultrasound stimulation. The hydrolysis reaction was carried out in a specially designed device, in which a heat flow steady state, between the ultrasound source and an external thermostatic bath, was maintained, in the absence of reactions. The exothermic hydrolysis causes a time dependent thermal peak. An induction time is apparent in pure TEOS before the hydrolysis peaks starts, which has been explained by the initial immiscibility gap of the TEOS-water system. The induction time was found to be approximately of the same magnitude as in the HCl catalyzed hydrolysis, in spite of the uncertainty accompanying the peak definition. No induction period is apparent in pure TMOS, so that the hydrolysis starts with its maximum rate. Two independent thermal peaks in the mixed TMOS-TEOS samples were found, both associated to the respective hydrolyses of the pure component. The induction time for the TEOS hydrolysis is decreased as more alcohol (and silanol) is produced in the earlier TMOS hydrolysis. This effect is explained by improvement of homogenization by alcohol.