958 resultados para eletroforese em gel de poliacrilamida
Resumo:
The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.
Resumo:
A new construction of a capillary electrophoresis instrument with a universal conductivity detector (oscillometric detector) is described. The performance of the electrophoresis equipment was evaluated through the separation and detection of inorganic anions and cations in aqueous solutions. The results reproduced those found in the literature for the investigated probe ions, showing an efficient separation and good repeatability.
Resumo:
This work reports the analysis of inorganic and organic contaminants in alcohol fuel samples using capillary electrophoresis. Chloride and sulfate were analyzed in nitrate/ monochloroacetic acid at 10 mmol L-1 concentration each under indirect UV detection (210 nm). The analysis of aldehydes is based on the 216 nm detection of 3-methyl-2-benzothiazoline hydrazone adducts. The running buffer consisted of 20 mmol L-1 tetraborate , 40 mmol L-1 sodium dodecyl sufate and 12 mmol L-1 beta-ciclodextrin. Both methodologies were applied to real samples indicating inorganic ion concentrations from 0.15 to 6.64 mg kg-1 and aldehydes from 32.0 to 91.3 mg L-1.
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
A novel type of heavy metal adsorbent was prepared by the covalent grafting of thioglycolic acid molecules on a silica gel surface previsiouly modified with 3-aminopropyltrimethoxysilane. The amount of thioglycolic acid immobilized was 1.03 mmol per gram of silica. This material displayed a chelating moiety containing nitrogen, sulfur, and oxygen basic centers which are potentially capable of extracting from aqueous solutions cations such as Cu(II), Ni(II), Co(II), influenced by pH and ionic strength. This process of extraction was carried out by the batch method when similar chemisorption isotherms were observed for all cations. A modified Langmuir equation describes the experimental data.
Resumo:
In this work, we report the synthesis and the photoluminescence features of a Eu(III)-doped modified silica matrix obtained by the sol-gel method. The matrix was prepared by reaction between tetraethylorthosilicate and phenyltriethoxysilane alkoxide. The hydrolysis occurred using basic catalysis. The solids were treated at 100, 200 and 300 ºC during 4 h and the structure was determined by thermogravimetric analysis (TG/DTG), nuclear magnetic resonance (NMR 29Si and 13C), infrared spectroscopy (IR) and photoluminescence (PL). The PL spectra display the Eu(III) lines characteristic of the ion, 5D0 -> 7F J (J=0, 1, 2, 3, 4), the blue emission as ascribed in the silica matrix. The NMR and TG showed the stability of hybrid silica.
Resumo:
CE-MS has been increasingly used for analysis of a vast array of compounds. This article reviews the different electrophoretic modes, interfaces and mass analyzers that are commonly used in the CE-MS coupling, as well as the technique advantages and performance characteristics. A large compilation of CE-MS applications is also presented. Therefore, this review is both a guide for beginners and a collection of key references for people who are familiar to the technique. Furthermore, this is the first CE-MS review published in a Brazilian journal and marks the installation of the first two commercial CE-MS units in Sao Paulo State.
Resumo:
Capillary electrophoresis has become a well-established and routine-based separation technique. It is based on the differences between charged analyte mobility in aqueous or organic electrolytes. Its major limitation is the sensitivity due to small sample injection volumes and the narrow diameter of the capillaries, especially when UV detection is used. There are a number of ways to increase the concentration sensitivity. This report shows some on-line preconcentration strategies to perform it in free solution capillary electrophoresis that are based on manipulation of the analyte electrophoretic velocity during the sample introduction (stacking, field amplification and transient isotachophoresis).
Resumo:
Usually, the concepts of the Sol-Gel technique are not applied in experimental chemistry courses. This work presents a feasible experiment for chemistry instruction, which involves the synthesis of luminescent materials - Zn2SiO4, with and without Mn2+ as a dopant - by the Sol-Gel technique. The obtained materials were analyzed by scanning electron microscopy, X-Ray diffraction, IR spectroscopy and luminescence measures by UV-vis spectroscopy. The results allow the students to confirm the luminescent properties of the zinc orthosilicate luminophores as well as the structural features expected from literature data.
Resumo:
The goal of this study was to produce and characterize a new microemulsion gel-like carrier system (MEG) by using the pseudo-ternary phase-diagram concept. The diclofenac diethylamine (DDA) was incorporated in the MEG and its in vitro release and permeation profiles were performed using Franz-type diffusion cells. The results revealed that the commercial DDA emulgel provided significantly higher Kp of DDA (2.2-fold) as compared to the MEG. Similar data were obtained in the permeation studies in which DDA Kp 4.7-fold higher. Therefore, MEG presents higher potential as a topical delivery system for DDA when compared to the commercial DDA emulgel.
Resumo:
In this paper, the effects of acrylamide (AAm), methylcellulose (MC) contents, pH and ionic strength on kinetic, network and hydrophilic properties of polyacrylamide and methylcellulose hydrogels were investigated. The hydrogels were characterized by evaluating of network [average molecular weight between crosslinks (M C), crosslink density (q) and the number of elastically effective chains (Ve)], and kinetic parameters [diffusional exponent (n), diffusion constant (k) and diffusion coefficient (D)]. Such properties were controlled by adjusting of the AAm, MC contents, pH and ionic strength factors. Due to high hydrophilicity and fast water-uptake, the PAAm-MC hydrogels can be considered as materials for potential applications in agricultural fields, mainly in controlled release of water or pesticides.
Resumo:
This review deals with silica based hybrid materials obtained by the sol-gel method. It involves concepts, classifications and important definitions regarding the sol-gel method that allows obtaining materials with organic and inorganic components dispersed in a molecular or nanometric level. We discuss the properties and characteristics of hybrid materials related to experimental synthesis conditions. We devote a special attention to the nanostructured materials, where the self-organization is imposed by the organic component. Finally, we present some important applications of these materials based on their specific properties.
Resumo:
This work describes the development of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the separation of the metallic species Zn2+, Cr3+, Pb2+, Cd2+, Co2+, Cu2+, Ni2+ e Tl+. A background electrolyte composed of MES/Histidine 0,02 mol L-1 (pH 5.0) was optimized for the separation of the metallic species by using organic solvents and complexing agents as additives. The system allowed the determination of the metallic species using MES/Histidine 0,02 mol L-1 and methanol 5% (pH 5.0) as a background electrolyte, 15 kV separation voltage and hydrodynamic injection by gravity.
Resumo:
Argentation chromatography is used to increase the selectivity of the chromatographic process, chiefly in the resolution of complex mixtures of nonpolar substances. Although efficient, this technique generates residues containing heavy metal which makes its discarding through common procedures impracticable. In the present work a simple method for recycling of silica, and also silver, from argentation chromatography is described. This procedure uses initially a treatment of H2O2/HNO3, with subsequent treatment with H2O2/H2SO4 , allowing an efficient recycling of both components. This methodology is simple, costless, removes impurities efficiently, and does not modify retention parameters nor specific surface in a significant way.
Resumo:
The present work purposes the preparation of a silica gel sorbent organically modified with 2-aminoethyl-3-aminobutylmethyldimethoxysilane (AAMDMS) and imprinted with Cu2+ ions by means surface imprinting technique and its use for selective on-line sorbent preconcentration of Cu2+ ions with further UV-VIS spectrophotometric determination by flow injection analysis. The Cu2+-imprinted silica gel, when compared with non imprinted silica gel and silica gel, showed from the binary mixture of Cu2+/Ni2+ relative selectivity coefficient (k') of 6.84 and 5.43 and 6.64 and 19.83 for the mixture Cu2+/Pb2+, thus demonstrating higher selectivity of Cu2+-imprinted silica gel towards Cu2+ ions. Under optimized condition, the on-line preconcentration method provided detection limit of 3.4 μg L-1 and linear range ranging from 30.0 up to 300.0 μg L-1 (r = 0.995). The accuracy of method was successfully assessed by analyzing different kind of spiked water samples with recovery values ranging from 92.2 up to 103.0%.